Toshiba RAS-10PKVPG-E, RAS-13PKVPG-E, RAS-16PAVPG-E, RAS-16PKVPG-E, RAS-13PAVPG-E Installation Manual

...
INSTALLATION MANUAL
1121451198
AIR CONDITIONER (SPLIT TYPE)
Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E
Outdoor unit RAS-10PAVPG-E RAS-13PAVPG-E RAS-16PAVPG-E
R32
EN
PRECAUTIONS FOR SAFETY ...........................................................................................................................................1
ACCESSORY PARTS ......................................................................................................................................................... 5
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS ...................................................................................6
n Optional Installation Parts ...............................................................................................................................................6
INDOOR UNIT .....................................................................................................................................................................7
n Installation Place .............................................................................................................................................................7
n Cutting a Hole and Mounting Installation Plate ...............................................................................................................7
n Piping and Drain Hose Installation ..................................................................................................................................8
n Indoor Unit Fixing ............................................................................................................................................................9
n In case of Indoor unit is xed to Installation plate with screws ........................................................................................9
n Drainage .........................................................................................................................................................................9
OUTDOOR UNIT ...............................................................................................................................................................10
n Installation Place ...........................................................................................................................................................10
n Precautions about Installation in Regions with Showfall and Cold Temperatures ........................................................10
n Refrigerant Piping Connection ......................................................................................................................................10
n Evacuating ...................................................................................................................................................................11
ELECTRICAL WORKS .....................................................................................................................................................12
n Wiring Connection .........................................................................................................................................................12
n Power Supply and Connecting Cable Connection ........................................................................................................13
n Power supply input Wiring Diagram ..............................................................................................................................14
CONTENTS
OTHERS ............................................................................................................................................................................15
n Gas Leak Test ...............................................................................................................................................................15
n Remote Control A-B Selection ...................................................................................................................................... 15
n Test Operation ...............................................................................................................................................................15
n Auto Restart Setting ......................................................................................................................................................15
EN
PRECAUTIONS FOR SAFETY
Read the precautions in this manual carefully before operating the unit.
This appliance is lled with
R32.
• Before installation, please read these precautions for safety carefully.
• Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below.
WARNING : It indicates that incorrect use of this unit may cause severe injury or
death.
CAUTION : It indicates that incorrect use of this unit may cause personal injury
(*1), or property damage (*2).
*1 : Personal injury means a slight accident, burn, or electrical shock
which does not require admission or repeated hospital treatment.
*2 : Property damage means greater damage which affects assets
or resources.
For general public use
Power supply cord and connecting cable of appliance use shall be at least polychloroprene sheathed exible cord (design H07RN-F) or cord designation 60245 IEC66. (Shall be installed in accordance with national wiring regulations.)
CAUTION
This appliance must be connected to the main power supply by means of a circuit
To disconnect the appliance from the main power supply
breaker or a switch with a contact separation of at least 3 mm in all poles.
1
DANGER
• FOR USE BY QUALIFIED PERSONS ONLY.
• TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.
• CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE DAMAGED.
• CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.
• DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS. FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
• TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.
• WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT (R32) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS.
• IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS.
WARNING
• Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
• Do not install in a place which cannot bear the weight of the unit. Personal injury and property damage can result if the unit falls.
• Before doing the electrical work, attach an approved plug to the power supply
cord.
Also, make sure the equipment is properly earthed.
• Appliance shall be installed in accordance with national wiring regulations. If you detect any damage, do not install the unit. Contact your dealer immediately.
2
EN
• Do not use any refrigerant different from the one specied for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body.
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition sources (for example: open ames, an operating gas appliance or an operating electric heater).
• Be aware that refrigerants may not contain an odour.
• Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, ame, sparks, or other sources or ignition. Else, it may explode and cause injury or death.
• For R32 model, use pipes, are nut and tools which is specied for R32 refrigerant. Using of existing (R22) piping, are nut and tools may cause abnormally high pressure in the refrigerant cycle (piping), and possibly result in explosion and injury.
• Thickness of copper pipes used R32 must be more than 0.8mm. Never use copper pipes thinner than 0.8mm.
• Do not perform are connection inside a building or dwelling or room, when joining the heat exchanger of indoor unit with interconnection piping. Refrigerant connection inside a building or dwelling or room must be made by brazing or welding. Joint connection of indoor unit by aring method can only be made at outdoor or at outside of building or dwelling or room. Flare connection may cause gas leak and ammable atmosphere.
• After completion of installation or service, conrm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contacts with re.
• Appliance and pipe-work shall be installed, operated and stored in a room with a oor area larger than A How to get A
m2 : A
min
m2.
min
= (M / (2.5 x 0.22759 x h0))2
min
M is the refrigerant charge amount in appliance in kg. h0 is the installation height of the appliance in m: 0.6 m for oor standing/1.8 m for wall mounted/1.0 m for window mounted/2.2 m for ceiling mounted (For these units recommend installation height 2.5 m.).
• Comply with national gas regulations.
3
CAUTION
• Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water.
• After unpacking the unit, examine it carefully for possible damage.
• Do not install the unit at place where leakage of ammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause of re.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and discharged air might disturb neighbors.
• To avoid personal injury, be careful when handling parts with sharp edges.
• Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.
• The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.
REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER
Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.
n Important information regarding the refrigerant used
This product contains uorinated greenhouse gases. Do not vent gases into the atmosphere. Refrigerant type: R32
GWP
(1)
(1)
value: 675 * (ex. R32 ref. AR4)
GWP = global warming potential The refrigerant quantity is indicated on the unit name plate. * This value is based on F gas regulation 517/2014
4