Toshiba DA364, DA374 User Manual

Specifications and Main Features

  • Types of Requirement: DA364 (Voltage request), DA374 (Current request) \n
  • Method of Output: Source output \n
  • Output metrics: \n
  • DA364:\n
  • Bipolar: -5 to +5V, -10 to +10V \n
  • Unipolar: 0 to +5V, 0 to +10V, 1 to 5V \n
  • DA374:
  • Unipolar: 0 to 20 mA, 4 to 20 mA \n
  • Load: 500Ω or more (10 V), 250Ω or more (5 V)\n
  • Channels of OUTPUT: 4 channels for each module \n
  • Resolution: 12 bits / 0.025% \n
  • Overall accuracy: ±0.2% at 25 degrees celsius, \n
  • Temperature drift: +100 ppm/°C \n
  • Conversion cycle: 10ms for 4 channels, for each channel 2.5 ms \n
  • Insulation: Photo-coupler insulation (not isolated among channels) \n
  • Insulation resistance: 10 MΩ \n
  • Withstand voltage: 500 Vac / 1 minute \n
  • External power required: 24 Vdc +/- 10%\n
  • Internal logic consumed current: 180 mA (5 Vdc) \n
  • Power supply externally current: 200 mA (24 Vdc)\n
  • Weight: 500 g \n

Frequently Asked Questions

  • Q: What are the output types of DA364/DA374? A: DA364 it’s voltage type modular, where da374 is a current type modular.
  • Q: How manifold does invoicing serve in terms of output channels for their modules?

A: It is true that each module is capable of producing 4 channels of output.

  • Q: What is the bit range of optimization in DA364/DA374 outputs?

A: The accuracy lies at 12 counts with a variation of 0.025%.

  • Q: What kind of external power supply does a module function properly.

A: Module has a requirement of external power supply of 24 Vdc + 10%.

  • Q: How frequently is it possible to refresh output data of any channel?

A: The output data shutting down marks can be superseded every 10 milliseconds across 4 different channels.

  • Q: Is it possible to alter output ranges even after the installation has completed?

A: The output ranges could be adjustable but note that doing so, will erase calibration data.

  • Q: What device is important to zone in clear signals output for a module?

A: The desired clear signal of the module output gets calibrated by changing gain and offset of the device.

  • Q: DA364 module outputs multiple signals what are they?

A: DA364 is capable of outputting both -5 to +5 and 0 to +10 signals.rstrip('\n')

  • Q: To what signals is the DA374 model capable to output?

A: This model is capable of outputting unipolar current signals in the range of 0 to 20 mA or 4 to 20 mA.

  • Q: What is the average time taken for conversion cycles for the modules?

A: The time conversion cycle takes approximately around 10 ms for all 4 channels and 2.5 ms for each individual channel.