![](/html/59/59ca/59caf598d2f18d1a6a6cd6af09a947e33f84e5836e4109a9ff1c952b7dc11114/bg1.png)
HSJ POWER VENTER SPECIFICATIONS
Performance curves
Static pressure (inches H2O) vs CFM (std. air) at selected flue gas temps.
NOTE: TO ARRIVE AT TOTAL SYSTEM STATIC PRESSURE REFER TO CURVE
AND ADD .38” TO COMPENSATE FOR VENT HOOD AND WIND RESISTANCE.
MOTOR ELECTRICAL DATA
Volts 115
Hertz 60
RPM 3000
Watts 95
Amps 1.26
Therm. Prot. Yes
MOTOR MECHANICAL DATA
DESCRIPTION
Shaded Pole Yes
Open Yes
Int. Fan Cooled Yes
BEARINGS
Type Sleeve
Material Sintered Iron
UC1 UNIVERSAL CONTROL
Maximum Power Consumption 1/2 Amp @
120 VAC 50/60 Hz + Venter motor load
Pre-Purge: Options (0,15,30,60 seconds)
Post-Purge: Factory set at 2 minutes
Options (0,30 seconds; 1,2,4,8,16 minutes)
Dimensions: 5” x 8” (2’ electrical whip inc.)
SAFETY / INTERLOCK
Fan Proving Switch
5 VDC UC1 board supplied power switched
through Fan Prover. UC1 burner / gas valve
interlock rated for 1 H.P. @ 120 VAC.
MODELS AND APPLICATION:
HSJ (Gas or Oil)
Used as a means of Side Wall Venting gas or
oil appliances which require a Post Purge cycle.
Used also to co-vent two gas heaters within
combined BTU/hr. input listed below (requires
accessory controls). Includes a Fan Proving
Switch and the UC1 Universal Control for 24V,
115V or “dry contact” actuation. LED diagnostics and Pre / Post-purge options are standard
with the UC1.
HSUL-J (Discontinued 8/05)
HS115-J & HST-J (Discontinued 7/02)
Replace above models with HSJ.
Note: Tjernlund Products, Inc. reserves the
right to make changes to specifications without
notification.
ADJUSTMENT ROD
DAMPER
TOLERANCE: ±1/8" UNLESS OTHERWISE NOTED
SHADED POLE MOTOR
3,000 R.P.M.
ADJUSTABLE DAMPER
FAN PROVING PRESSURE SWITCH
4 5/8
3 1/8
9 5/8
4 I.D.
2
4 I.D.
7
9 7/8
1 7/8
1
4 3/4
7 5/8
4 I.D.
5 5/8
7 1/2
2 1/4
5 1/4
FIGURE 2061000-3
1 1/2
FAN PROVER SENSOR
SHIELD
DRIP
1 1/8
-SIDE VIEW- -END VIEW- -PLAN VIEW-
P/N 8506001
REV. B 2/06
500°F
400°F
300°F
70°F
1.00
.80
.60
.20
.40
1601401208060 1004020CFM (std air)
DIA.
VENT BTU / HR
MAXIMUM PIPE LENGTH
OILGAS
23'
--
--
100'
100'
100'
100'
100'
35'
100'
100'
100'
125,000
100,000
75,000
50,000
4"HSJ
500° F400° F300° F
FIREDFIRED
AT STACK TEMPERATURE
(FT)
INPUT
PIPE
MODEL
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
![](/html/59/59ca/59caf598d2f18d1a6a6cd6af09a947e33f84e5836e4109a9ff1c952b7dc11114/bg2.png)
HS1 POWER VENTER SPECIFICATIONS
Performance curves
Static pressure (inches H2O) vs CFM (std. air) at selected flue gas temps.
NOTE: TO ARRIVE AT TOTAL SYSTEM STATIC PRESSURE REFER TO CURVE
AND ADD .38” TO COMPENSATE FOR VENT HOOD AND WIND RESISTANCE.
MODELS AND APPLICATION:
HS1 (Gas or Oil)
Used as a means of Side Wall Venting gas or
oil appliances which require a Post Purge cycle.
Used also to co-vent multiple heaters within
combined BTU/hr. input listed below (requires
accessory controls). Includes a Fan Proving
Switch and the UC1 Universal Control for 24V,
115V or “dry contact” actuation. LED diagnostics and Pre / Post-purge options are standard
with the UC1.
HSUL-1 (Discontinued 8/05)
HS115-1 & HST-1 (Discontinued 7/02)
Replace above models with HS1.
Note: Tjernlund Products, Inc. reserves the
right to make changes to specifications without
notification.
70°F
300°F
400°F
500°F
1.00
.60
.20
.40
.80
16014010080 1206040CFM (std air) 20
FIGURE 2011038-3
1 1/2
SHIELD
DRIP
TOLERANCE: ±1/8" UNLESS OTHERWISE NOTED
SHADED POLE MOTOR
3,000 R.P.M.
7 5/8
4 I.D.
5 5/8
7 1/2
2 1/4
5 1/4
ADJUSTMENT ROD
DAMPER
4 5/8
3 1/8
1 1/8
10 3/4
2 1/16
4 I.D.
7
4 I.D.
FAN PROVER SENSOR
134 3/4
11
FAN PROVING PRESSURE SWITCH
ADJUSTABLE DAMPER
DIA.
VENT BTU / HR
MAXIMUM PIPE LENGTH
OILGAS
--
--
--
--
--
--
35'
27'
100'
100'
60'
57'
12'
100'
100'
92'
100'
30'
100'
100'
4'
40'
87'
100'
150,000
200,000
250,000
300,000
300,000
250,000
200,000
150,000
6"
4"
HS1
500° F400° F300° F
FIREDFIRED
AT STACK TEMPERATURE
(FT)
INPUT
PIPE
MODEL
-SIDE VIEW- -END VIEW- -PLAN VIEW-
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
MOTOR ELECTRICAL DATA
Volts 115
Hertz 60
RPM 3000
Watts 95
Amps 1.26
Therm. Prot. Yes
MOTOR MECHANICAL DATA
DESCRIPTION
Shaded Pole Yes
Open Yes
Int. Fan Cooled Yes
BEARINGS
Type Sleeve
Material Sintered Iron
UC1 UNIVERSAL CONTROL
Maximum Power Consumption 1/2 Amp @
120 VAC 50/60 Hz + Venter motor load
Pre-Purge: Options (0,15,30,60 seconds)
Post-Purge: Factory set at 2 minutes
Options (0,30 seconds; 1,2,4,8,16 minutes)
Dimensions: 5” x 8” (2’ electrical whip inc.)
SAFETY / INTERLOCK
Fan Proving Switch
5 VDC UC1 board supplied power switched
through Fan Prover. UC1 burner / gas valve
interlock rated for 1 H.P. @ 120 VAC.