MODEL HMWB36FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS
Page 2
VENTILATION
PROFESSIONAL & MASTERPIECE® SERIES
VENTILATION
No need to worry about lingering odors or smoke with our
elegant, powerful ventilation systems, featuring design accents
that complement our Professional Series or our Masterpiece®
Collection. These sophisticated ventilation systems remove
smoke, grease and unhealthy airborne contaminants. From
standard wall to specialty hoods, downdrafts, island and custom
inserts, each model has one thing in common: legendary
Thermador performance. These powerful, quiet systems
tackle unwanted smoke, grease, heat and odors—quietly and
efficiently—with ventilation power ranging from 400
to 1,300 CFM.
1.800.735.4328 | THERMADOR.COM
133
Page 3
VENTILATION RANGE, RANGETOp AND VENTILATION MATRIX
pROFESSIONAL SERIES
= PErFECT FIT
= VIABLE oPTIoN
27-INCH DEPTH
WALL HooDs
24-INCH DEPTH
WALL HooDs
30" PH30Cs
36" PH36Cs
42" PH42Cs
48" PH48Cs
54" PH54Cs
30" HPWB30Fs
36" HPWB36Fs
48" HPWB48Fs*
42" HNI42Ys
30-INCH
Pro GrAND
36-INCH
Pro GrAND
48-INCH
Pro GrAND
30-INCH
Pro HArmoNY
24-INCH DEPTH27-INCH DEPTH
134
48" HNI48Ys
IsLAND HooDs
54" HNI54Ys
30" VCI230Ds
36" VCI236Ds
CusTom INsErTs
48" VCI248Ds
The width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador blowers.
*High heat tested to accommodate Pro Harmony™ or Pro Rangetop 18,000 burners and grill.
Page 4
VENTILATION RANGE, RANGETOp AND VENTILATION MATRIX
pROFESSIONAL SERIES
VENTILATION
36-INCH
PRO HARMONY
24-INCH DEPTH24-INCH DEPTH
48-INCH
PRO HARMONY
30-INCH
RANGETOP
36-INCH
RANGETOP
48-INCH
RANGETOP
1.800.735.4328 | THERMADOR.COM
135
Page 5
VENTILATION COOKTOP AND VENTILATION MATRIX
MASTERPIECE® SERIES
= PErFECT FIT
= VIABLE OPTION
WALL HOODS WITH BLOWEr
WALL HOODS
CHIMNEY HOODS WITH BLOWEr
CHIMNEY HOODS
30" HMWB30FS
36" HMWB36FS
30" HMWN30FS
36" HMWN36FS
48" HMWN48FS
36" HMCB36FS
42" HMCB42FS
36" HMCN36FS
42" HMCN42FS
30-INCH
INDuCTION
36-INCH
INDuCTION
30-INCH
GAS COOKTOP
36-INCH
GAS COOKTOP
36" HDDW36FS
DrAWEr HOOD
36" HGEW36FS
GLASS CANOPY HOOD
30" uCVM
DOWNDrAFT
36" uCVM
21" VCI21CS
CuSTOM INSErTS
29" VCI29CS
42" HGSI42TS
ISLAND HOOD
The width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador blowers.
INLINE (MOUNTED BETWEEN KITChEN AND EXTERNAL WALL)
vTi610D - 600 CFMvTi1010D - 1000 CFM
Page 10
VENTILATION HOODS THAT FIT WITH YOUR KITCHEN
When selecting a ventilation system, choose from one of our two sophisticated appliance collections. Select Professional Series for the ultimate
in cooking and venting power or the Masterpiece® Series for its sleek styling and numerous convenience functions.
WALL HOODS
Wall hoods offer exceptional, quiet performance and distinctive design options.
VENTILATION
• Efficient, high quality, all stainless steel filters
• Halogen lighting
• Deep enclosure area for excellent capture
CHImNEY HOODS
Our chimney style hoods impart a more traditional feel to the kitchen space.
• Adjustable chimney heights suit a range of ceilings
• All stainless steel or stainless steel with glass
designs available
ISLAND HOODS
Thermador island hoods offer excellent overall efficiency in drawing away smoke, moisture and heat.
• An option for when a wall surface is not available
• All stainless steel or stainless steel with elegant
glass canopy design
CUSTOm INSERTS
To create a seamless design with wall or island applications, use custom hood inserts.
• Available options for all types of cooking surfaces
• User-friendly ventilation controls or remote
control options
DOWNDRAFTS
Downdraft ventilation offers space efficiency and a sleek look for non-professional cooktops.
• Over 13-inch intake
• Full face filter combines a filter with splatter shield
in one easy-to-remove, dishwasher safe element
1.800.735.4328 | THERMADOR.COM
• Wall or island applications
• Halogen lighting
• Wall or island applications
• 600 CFM recirculation kit option with integral
blower is available for difficult-to-duct situations
141
Page 11
142
MODEL HPWB48FS SHOWN WITH 48-INCH PRO HARMONY® RANGE PRD486GDHU
AND 36-INCH WARMING DRAWER WDF30EP
Page 12
VENTILATION
WALL HOODS
VENTILATION — WALL HOODS
Thermador Wall Hoods put the finishing touch on your cooking
system, with deep capture areas for the best overall efficiency
in drawing away smoke, moisture and heat. These elegant
hoods combine style with vigorous performance, generating
ventilation power from 600 to 1,300 CFM. Available in a
variety of heights, widths and depths, they accommodate your
individual venting needs. All models include brilliant halogen
lighting for enhanced visibility and convenient speed controls.
For ultra-simple cleanup, the removable filters and grease
collection trays fit easily in your dishwasher.
1.800.735.4328 | THERMADOR.COM
143
Page 13
WALL HOODS FEATURES & BENEFITS
HALOgEN LIgHTS
Bright halogen lighting spotlights your best recipes.
DELAYED SHUTOFF
For the greatest efficiency, our Professional ventilation
models include delayed shut-off to tackle lingering odors.
(Except HMWB30FS, HMWB36FS)
PLANNINg INFORmATION
BAFFLE FILTERS
Unique low-profile baffle
filters maximize grease
capture without affecting flow,
and they’re dishwasher safe
for easy clean-up.
POWERFUL VENTILATION
Breathe deeply with the air-freshening power of up to 1,300
CFM. Our new HPWB Series Professional Hood now has blower
included for ease of installation.
TImE-TO-CLEAN-FILTER LIgHT
Easy clean-up: all Thermador ventilation filters are dishwasher
safe, and many hoods feature a built-in Time-to-Clean-Filter
reminder light. (Except HMWB30FS, HMWB36FS)
KEEP-HOT SHELF
Hold dishes at serving temperature on our optional Keep-Hot
Shelf. (PH30CS, PH36CS, PH42CS, PH48CS and PH54CS only)
EXTERIOR CONTROLS
Easy-to-clean, easy-to-use
push-button controls put
accuracy at your fingertips.
144
mODEL OPTIONS
When selecting a ventilation system, choose from
one of our two sophisticated appliance collections.
Select Professional Series for the ultimate in cooking
and venting power or the Masterpiece® Series for its
sleek styling and numerous convenience functions.
Thermador Wall Hoods are available in various
depths and heights to fit your kitchen plans and are
meticulously crafted for both function and design.
Be sure to reference the correct model information
in this design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Wall Hood is properly installed and grounded by a
qualified technician. Installation, electrical connections and grounding must
comply with all applicable local codes.
Install a suitable conduit box (not furnished). An appropriately-sized, UL-listed
conduit connector must be used to correctly attach the conduit to the junction
box. Remote blowers require a five wire installation.
mODELREQUIRED CIRCUIT BREAKER
120V AC, 60 Hz
PH30CS, PH36CS, PH42CS,
PH48CS, PH54CS
HPWB30FS, HPWB36FS, HPWB48FS15 or 20 Amp
HMWN30FS, HMWN36FS,
HMWN48FS
HMWB30FS, HMWB36FS15 or 20 Amp
20 Amp
15 or 20 Amp
Page 14
WALL HOODS PLANNINg INFORmATION
VENTILATION — WALL HOODS
INSTALLATION CONSIDERATIONS
The information in this design guide provides key
features, product dimensions, cutouts and installation
specifications. Before installing a Thermador Wall
Hood, be sure to verify the cutout dimensions and
electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
Thermador Wall Hoods may be installed above a
Thermador Cooktop or Range to create a convenient
cooking center. Refer to the appropriate section for
additional specifications.
HOOD WIDTH
The hood width should be no less than the width of the
cooking surface. Where space is not restricted, a wider
hood can be used to increase your capture area.
DISTANCE FROm COOKINg SURFACE
Proper mounting height is very important. If a hood
is mounted too low, it may be difficult to cook and be
unsafe. If a hood is mounted too high, performance
may be compromised. For optimal performance, the
distance from the cooking surface to the bottom of the
hood should be a minimum of 30", unless otherwise
noted. Please refer to the installation manual for each
hood and cooktop/range model for proper hood
mounting heights.
AVAILABLE CEILINg HEIgHT
The standard ceiling height can vary from region to
region and in homes built in different eras. Ceiling
heights, even in the same room, can sometimes vary by
as much as several inches. Kitchen ceiling heights can
vary between 7'6" (or 90") to over 10' (or 120").
Before selecting a Thermador Hood, check the
available installation space and any extra space that
may remain after proper installation of a hood and
cooktop or range. This extra space can be filled using
Thermador’s stainless steel duct cover accessories or
integrated with kitchen cabinetry. The space can also
be adjusted by raising or lowering your hood within the
recommended range (typically 30" to 36" above the
cooking surface).
CHOOSINg THE CORRECT BLOWER
A variety of interior and exterior blower options
(Remote, Inline or Integral) are available for
Thermador’s Professional and Masterpiece® Series
Hoods. If the unit you have selected does not have
a blower, one can be purchased separately. Blower
selection will vary based on the volume of air that
needs to be moved and the length and location of the
duct run. For long duct runs with multiple turns and
bends, consider using a more powerful blower. For the
most efficient air flow exhaust, use a straight run or as
few elbows as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these blowers can be
mounted on the roof or exterior wall of your home. An exterior installation
may be more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are mounted along the
duct line anywhere between the kitchen and the exterior wall. If you have
easy access to your duct line (in an attic, for example), this may be an
appealing option.
Integral Blowers (VTN series)
These blowers are purchased separately and integrated into the hood or onto
the downdraft unit at the time of installation. This option allows you to select
your ideal hood with the exact power you require.
CHOOSINg THE RIgHT CFm
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional gas
cooktops generally should have 1 CFM for every 100 BTU.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with airflow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 600 CFM may be adequate ventilation for the
cooking space.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a good
alternative.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
LENgTH AND SIzE OF DUCTWORK
Do not use flexible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
Proper performance is dependent upon proper ducting. Use a qualified and
trained installer. Local building codes may require the use of make-up air
systems when using ducted ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale. Consult your
HVAC professional for specific requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
Thermador Wall Hoods may be installed above a Thermador Cooktop
or Range to create a convenient cooking center. Refer to the appropriate
section for additional specifications.
Hood installation height above a cooktop or range can vary. To obtain
the necessary installation height above a Thermador Professional
Cooktop or Range, consult the appliance's installation manual. Accessory
6" and/or 12" duct covers are used to fill the space between the hood
and ceiling.
Both vertical and horizontal discharge is possible with either mounting
method. The hood is shipped ready for vertical discharge.
VENTILATION — WALL HOODS
Models: PH30CS, PH36CS, PH42CS, PH48CS, PH54CS
BLOWER OPTIONS
REMOTE (Mounted to roof or external wall)
REMOTE
VTR630D – 600 CFMUse RFPLT600 in
VTR630D 600 CFM
VTR1030D 1000 CFM
roof-mount applications
VTR1030D – 1000 CFMUse RFPLT1000 in
VTR1330E – 1300 CFM
INLINE (Mounted between kitchen and external wall)INTEGRAL (Mounted on hood)
VTI610D 600 CFMVTN630C 600 CFM
VTI1010D 1000 CFMVTN1030C 1000 CFM
83/4"
81/4"
25"
VTR1330E 1300 CFM
81/4"
25"
REMOTE BLOWER ACCESSORIES
RFPLT600, RFPLT1000 – Roof plate Material
For use with Remote Blowers VTR630D, VTR1030D and VTR1330E
Combinations
Roof plateRemote Blower
RFPLT600VTR630D
RFPLT1000VTR1030D, VTR1330E
Model No.ABCDuct Size
RFPLT6007
RFPLT1000 9
1.800.735.4328 | THERMADOR.COM
Overall Dimensions
1
/2" 8 1/2" 9 1/4"6"
3
/8"12"11 1/8"10"
147
Page 17
VENTILATION 24-INCH DEPTH WALL HOOD WITH BLOWER (30"/36"/48")
Models: HPWB30FS, HPWB36FS, HPWB48FS
PERFORMANCE
- 3 fan speeds
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
- Extended capture area ensures removal of smoke and odor
DESIGN
PROFESSIONAL
HPWB30FS – 30-Inch
HPWB36FS – 36-Inch
HPWB48FS – 48-Inch
SPECIFICATIONS
Available Hood Widths 30", 36", 48"
Blower30" – 600 CFM Blower Included
36" – 1200 CFM Blower Included
48" – 1200 CFM Blower Included
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher Safe Filters Low-Profile Baffle
Halogen Lighting30", 36" – 2 Bulbs
48" – 3 Bulbs
- Brushed stainless steel finish
- Welded, polished seams for a flawless design
- Stainless steel button controls
CAPACITY
- Integrated Blower included
- Recirculation possible with kit RECIRC__FS (max 600 CFM)
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe low-profile baffle filters
- Grease collection trays are easily removed, dishwasher safe
- Built-in Clean Filter Reminder light
- Delayed shut off tackles lingering odors for up to 10 minutes
- Hood includes filters, backdraft damper and transition
- Accessories include: 6" Duct Covers or 12" Duct Covers
148
ACCESSORIES
DC__US – 6-Inch High Duct Cover
DCT__US – 12-Inch High Duct Cover
For use with PH__DS, HPWB__FS,
HMWN__FS and HMWB__FS
Width6-Inch High 12-Inch High
30-InchDC30USDCT30US
36-InchDC36USDCT36US
48-InchDC48USDCT48US
RECIRC__FS – Recirculation Kit
(30"/36") RECIRC30FS/RECIRC36FS
- For use with HPWB30FS, HMWN__FS
and HMWB__FS
- Stainless steel finish
- Perfect for hard to duct installations
- Use with 600 CFM blowers only
4"
30" , 36"
CHFILT3036 – Replacement Charcoal Filters
For use with Recirculation Kit
12"
Page 18
VENTILATION 24-INCH DEPTH WALL HOOD WITH BLOWER (30"/36"/48")
INSTALLATION OPTIONS
Thermador Wall Hoods may be installed above a Thermador Cooktop or
Range to create a convenient cooking center. Refer to the appropriate
section for additional specifications.
Hood installation height above a cooktop or range can vary. To obtain
the necessary installation height above a Thermador Professional
Cooktop or Range, consult the appliance's installation manual.
Accessory 6" and/or 12" duct covers are used to fill the space between
the hood and ceiling.
This Thermador Wall Hood can be mounted on a wall or suspended from
a cabinet. The cabinet must be structurally joined to the wall studs to
support the weight of this hood.
These hoods are designed to be used for vertical discharge. A ductless,
recirculation installation is possible with kit RECIRC__FS.
VENTILATION — WALL HOODS
models: HPWB30FS, HPWB36FS, HPWB48FS
1.800.735.4328 | THERMADOR.COM
149
Page 19
VENTILATION WALL HOOD (30"/36"/48")
Models: HMWN30FS, HMWN36FS, HMWN48FS
MASTERPIECE
HMWN30FS – 30-Inch
HMWN36FS – 36-Inch
HMWN48FS – 48-Inch
SPECIFICATIONS
Available Hood Widths 30", 36", 48"
BlowerSold separately –
See Blower Options table
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher Safe Filters Low-Profile Baffle
Halogen Lighting30", 36" – 2 Bulbs
48" – 3 Bulbs
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
- Extended capture area ensures removal of smoke and odor
- Recirculation possible with kit RECIRC__FS (max 600 CFM)
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe low-profile baffle filters
- Grease collection trays are easily removed, dishwasher safe
- Built-in Clean Filter Reminder light
- Delayed shut off tackles lingering odors for up to 10 minutes
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
- Hood includes filters, backdraft damper and transition
150
ACCESSORIES
DC__US – 6-Inch High Duct Cover
DCT__US – 12-Inch High Duct Cover
For use with PH__DS, HPWB__FS,
HMWN__FS and HMWB__FS
Width6-Inch High 12-Inch High
30-InchDC30USDCT30US
36-InchDC36USDCT36US
48-InchDC48USDCT48US
RECIRC__FS – Recirculation Kit
(30"/36") RECIRC30FS/RECIRC36FS
- For use with HPWB30FS, HMWN__FS
and HMWB__FS
- Stainless steel finish
- Perfect for hard to duct installations
- Use with 600 CFM blowers only
4"
30" , 36"
CHFILT3036 – Replacement Charcoal Filters
For use with Recirculation Kit
12"
Page 20
INSTALLATION OPTIONS
Thermador Wall Hoods may be installed above a Thermador Cooktop or
Range to create a convenient cooking center. Refer to the appropriate section
for additional specifications.
Hood installation height above a cooktop or range can vary. To obtain the
necessary installation height above a Thermador Professional Cooktop or
Range, consult the appliance's installation manual.
Accessory 6" and/or 12" duct covers are used to fill the space between the
hood and ceiling.
Thermador Wall Hoods can be mounted on a wall or suspended from a
cabinet. The cabinet must be structurally joined to the wall studs to support
the weight of this hood.
These hoods are designed to be used for vertical discharge. A ductless,
recirculation installation is possible with kit RECIRC__FS.
These hoods are not recommended to be used over indoor grills.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFMUse RFPLT600 in
roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in
roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000 in
roof-mount applications
(Not for use with 30" hood)
INLINE
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEGRATED
VTN600F – 600 CFM
VTN1000F – 1200 CFM Not for use with 30" hood
See page 145 for further details.
REMOTE (Mounted to roof or external wall)
VTR630D 600 CFM
VENTILATION WALL HOOD (30"/36"/48")
Models: HMWN30FS, HMWN36FS, HMWN48FS
VTR1030D 1000 CFM
VTR1330E 1300 CFM
VENTILATION — WALL HOODS
INLINE (Mounted between kitchen and external wall)
VTI610D 600 CFM
REMOTE BLOWER ACCESSORIES
RFPLT600, RFPLT1000 – Roof plate Material
For use with Remote Blowers VTR630D, VTR1030D and VTR1330E
Combinations
Roof plateRemote Blower
RFPLT600VTR630D
RFPLT1000VTR1030D, VTR1330E
VTI1010D 1000 CFM
Model No.ABCDuct Size
RFPLT6007
RFPLT1000 9
1.800.735.4328 | THERMADOR.COM
INTEGRAL (Mounted on hood)
VTN600F 600 CFMVTN1000F 1200 CFM
Overall Dimensions
1
/2" 8 1/2" 9 1/4"6"
3
/8"12"11 1/8"10"
151
Page 21
VENTILATION WALL HOOD WITH BLOWER (30"/36")
Models: HMWB30FS, HMWB36FS
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- Filter systems are highly efficient at capturing grease
- Powerfully quiet ventilation systems
- Extended capture area ensures removal of smoke and odor
DESIGN
MASTERPIECE
HMWB30FS – 30-Inch
HMWB36FS – 36-Inch
SPECIFICATIONS
Available Hood Widths 30", 36"
Blower600 CFM Blower Included
- Classic chiseled design matches Thermador’s Masterpiece® Series
family of kitchen appliances
- Brushed stainless steel finish
- Welded, polished seams for a flawless design
- Easy to operate control buttons
CAPACITY
- 600 CFM Integrated Blower included
- Recirculation possible with kit RECIRC__FS (max 600 CFM)
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe low-profile baffle filters
- Grease collection trays are easily removed, dishwasher safe
- Hood includes filters, backdraft damper and transition
152
ACCESSORIES
DC__US – 6-Inch High Duct Cover
DCT__US – 12-Inch High Duct Cover
For use with PH__DS, HPWB__FS,
HMWN__FS and HMWB__FS
Width6-Inch High 12-Inch High
30-InchDC30USDCT30US
36-InchDC36USDCT36US
RECIRC__FS – Recirculation Kit
(30"/36") RECIRC30FS/RECIRC36FS
- For use with HPWB__FS, HMWN__FS
and HMWB__FS
- Stainless steel finish
- Perfect for hard to duct installations
- Use with 600 CFM blowers only
4"
30" , 36"
CHFILT3036 – Replacement Charcoal Filters
For use with Recirculation Kit
12"
Page 22
VENTILATION WALL HOOD WITH BLOWER (30"/36")
INSTALLATION OPTIONS
Thermador Wall Hoods may be installed above a Thermador Cooktop or
Range to create a convenient cooking center. Refer to the appropriate section
for additional specifications.
Hood installation height above a cooktop or range can vary. To obtain the
necessary installation height above a Thermador Professional Cooktop or
Range, consult the appliance's installation manual.
Accessory 6" and/or 12" duct covers are used to fill the space between the
hood and ceiling.
Thermador Wall Hoods can be mounted on a wall or suspended from a
cabinet. The cabinet must be structurally joined to the wall studs to support
the weight of this hood.
These hoods are designed to be used for vertical discharge. A ductless,
recirculation installation is possible with kit RECIRC__FS.
These hoods are not recommended to be used over indoor grills.
VENTILATION — WALL HOODS
Models: HMWB30FS, HMWB36FS
1.800.735.4328 | THERMADOR.COM
153
Page 23
154
154
MODEL HMCB42FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS
MODEL HMCB42FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS
Page 24
VENTILATION
CHIMNEY WALL HOODS
VENTILATION — CHIMNEY WALL HOODS
Our Masterpiece® Series Chimney Style Hoods impart a more
open kitchen environment and create a dramatic gathering point.
Each model is adjustable to suit a range of ceiling heights and
includes conveniences such as dishwasher safe, anodized filters
and electronic 4-speed controls. Halogen lighting brilliantly
illuminates your cooking space for excellent visibility.
1.800.735.4328 | THERMADOR.COM
155
Page 25
CHIMNEY WALL HOODS FEATURES & BENEFITS
ELECTRONIC TOUCH CONTROL
The sleek electronic touch control panel is easy to use and easy to clean.
MESH FILTERS
Aluminum mesh filters with stainless
steel frame maximize grease capture
without affecting flow and feature a
quick release latch for easy clean-up.
HALOgEN LIgHTS
Bright halogen lighting spotlights your best recipes.
PLANNINg INFORMATION
MODEL OPTIONS
Thermador Masterpiece Series Chimney Wall Hoods
feature sleek styling and numerous convenience
functions. Chimney Wall Hoods are available in
36-inch and 42-inch widths and are adjustable to
suit a range of ceiling heights. All stainless steel or
stainless steel with glass designs are available. Be
sure to reference the correct model information in
this design guide.
TIME-TO-CLEAN-FILTER LIgHT
Easy clean-up: All Thermador ventilation filters are dishwasher safe,
and many hoods feature a built-in Time-to-Clean-Filter reminder light.
(Except HMCB36FS, HMCB42FS)
DELAYED SHUTOFF
For the greatest efficiency, our Masterpiece® ventilation models
include delayed shutoff to tackle lingering odors. (Except HMCB36FS,
HMCB42FS)
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Chimney Wall Hood is properly installed and
grounded by a qualified technician. Installation, electrical connections and
grounding must comply with all applicable local codes.
If possible, site the earthed socket directly behind the chimney paneling.
The grounded socket should be connected via its own circuit. If the
grounded socket is no longer accessible following installation of the hood,
ensure that there is a permanently installed disconnector.
The information in this design guide provides key
features, product dimensions, cutouts and installation
specifications. Before installing a Thermador Chimney
Wall Hood, be sure to verify the cutout dimensions
and electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
Thermador Chimney Wall Hoods may be installed
above a Thermador non-professional gas, electric,
or induction cooktop to create a convenient cooking
center. Refer to the appropriate section for additional
specifications.
HOOD WIDTH
The hood width should be no less than the width of the
cooking surface. Where space is not restricted, a wider
hood can be used to increase your capture area.
DISTANCE FROM COOKINg SURFACE
Proper mounting height is very important. If a hood
is mounted too low, it may be difficult to cook and be
unsafe. If a hood is mounted too high, performance
may be compromised. For optimal performance, the
distance from the cooking surface to the bottom of the
hood should be a minimum of 30", unless otherwise
noted. Please refer to the installation manual for each
hood and cooktop/range model for proper hood
mounting heights.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these blowers can be
mounted on the roof or exterior wall of your home. An exterior installation
may be more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are mounted along the
duct line anywhere between the kitchen and the exterior wall. If you have
easy access to your duct line (in an attic, for example), this may be an
appealing option.
Integral Blowers (VTN series)
These blowers are purchased separately and integrated into the hood or onto
the downdraft unit at the time of installation. This option allows you to select
your ideal hood with the exact power you require.
CHOOSINg THE RIgHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional gas
cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,
choose a blower with a minimum of 100 CFM per 12" of cooktop width.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with airflow of 600 to 1300 CFM.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 600 CFM may be adequate ventilation for the
cooking space.
AVAILABLE CEILINg HEIgHT
The standard ceiling height can vary from region to
region and in homes built in different eras. Ceiling
heights, even in the same room, can sometimes vary by
as much as several inches. Kitchen ceiling heights can
vary between 7'6" (or 90") to over 10' (or 120").
Before selecting a Thermador Hood, check the
available installation space and any extra space that
may remain after proper installation of a hood and
cooktop or range. This extra space can be filled using
Thermador’s stainless steel duct cover accessories. The
space can also be adjusted by raising or lowering your
hood within the recommended range (typically 30" to
36" above the cooking surface).
CHOOSINg THE CORRECT BLOWER
A variety of interior and exterior blower options
(Remote, Inline or Integral) are available for
Thermador’s Masterpiece® Series Hoods. If the unit you
have selected does not have a blower included, one
can be purchased separately. Blower selection will vary
based on the volume of air that needs to be moved
and the length and location of the duct run.
For long duct runs with multiple turns and bends,
consider using a more powerful blower. For the most
efficient air flow exhaust, use a straight run or as few
elbows as possible.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a good
alternative.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
LENgTH AND SIzE OF DUCTWORK
Do not use flexible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
Proper performance is dependent upon proper ducting. Use a qualified and
trained installer. Local building codes may require the use of makeup air
systems when using ducted ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale. Consult your
HVAC professional for specific requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
WARRANTY
Limited warranty parts and labor (1 year)
See page 294 for additional warranty details.
1.800.735.4328 | THERMADOR.COM
157
Page 27
VENTILATION CHIMNEY WALL HOOD (36"/42")
Models: HMCN36FS, HMCN42FS
MASTERPIECE
HMCN36FS – 36-Inch
HMCN42FS – 42-Inch
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- Dimmer lighting – for those hours after a late meal
- Built-in Clean Filter Reminder light
- Telescopic chimney – adjustable at installation
- Delayed shutoff tackles lingering odors for up to 10 minutes
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
SPECIFICATIONS
Available Hood Widths 36", 42"
BlowerSold Separately—
Duct Size at Discharge8" Round
Ducting DirectionVertical
Ceiling Heights8 ft. to 9 ft.
Dishwasher Safe Filters 3 Mesh with Stainless Frame
Halogen Lighting3
See Blower Options Table
ACCESSORIES
CHIMXHMC – Chimney Extension
- For use with HMCN_FS, HMCB_FS
- Stainless steel chimney hood extension
for up to 12-foot ceiling applications
- Extension replaces upper section of
standard chimney extension
158
Page 28
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional specifications.
Hood installation height above a cooktop can vary. To obtain the
necessary installation height above a Thermador non-professional
gas, electric, or induction cooktop, consult the appliance’s
installation manual.
Thermador Chimney Wall Hoods must be mounted on a wall.
These hoods are designed to be used for vertical discharge.
A blower must be purchased separately.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFMUse RFPLT600 in
VTR1030D – 1000 CFM
VTR1330E – 1300 CFM
INLINE
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEgRATED
VTN1080F – 1000 CFM
See page 145 for further details.
roof-mount applications
Use RFPLT1000 in
roof-mount applications
VENTILATION CHIMNEY WALL HOOD (36"/42")
VENTILATION — CHIMNEY WALL HOODS
Models: HMCN36FS, HMCN42FS
REMOTE (Mounted to roof or external wall)
VTR630D 600 CFM
INTEgRAL (Mounted on hood)
VTN1080F 1000 CFM
VTR1030D 1000 CFM
INLINE (Mounted between kitchen and external wall)
VTR1330E 1300 CFM
REMOTE BLOWER ACCESSORIES
RFPLT600, RFPLT1000 – Roofplate Material
For use with Remote Blowers VTR630D, VTR1030D and VTR1330E
Combinations
RoofplateRemote Blower
RFPLT600VTR630D
RFPLT1000VTR1030D, VTR1330E
Overall Dimensions
Model No.ABCDuct Size
RFPLT6007
RFPLT1000 9
1
/2" 8 1/2" 9 1/4"6"
3
/8"12"11 1/8"10"
VTI610D 600 CFMVTI1010D 1000 CFM
1.800.735.4328 | THERMADOR.COM
159
Page 29
VENTILATION CHIMNEY WALL HOOD WITH BLOWER (36"/42")
Models: HMCB36FS, HMCB42FS
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- Hood includes filters, lights, backdraft damper and transition
SPECIFICATIONS
Available Hood Widths 36", 42"
Blower600 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights8 ft. to 9 ft.
Dishwasher Safe Filters 3 Mesh
Halogen Lighting3
ACCESSORIES
CHIMXHMC – Chimney Extension
- For use with HMCB__FS, HMCN__FS
- Stainless steel chimney hood extension
for up to 12-foot ceiling applications
- Extension replaces upper section of
standard chimney extension
160
Page 30
VENTILATION CHIMNEY WALL HOOD WITH BLOWER (36"/42")
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional specifications.
Hood installation height above a cooktop can vary. To obtain the
necessary installation height above a Thermador non-professional
gas, electric, or induction cooktop, consult the appliance's
installation manual.
Thermador Chimney Wall Hoods must be mounted on a wall.
These hoods are designed to be used for vertical discharge.
A 600 CFM integrated blower is included.
VENTILATION — CHIMNEY WALL HOODS
Models: HMCB36FS, HMCB42FS
1.800.735.4328 | THERMADOR.COM
161
Page 31
VENTILATION PIVOT-LIFT gLASS CANOPY HOOD (36")
Model: HgEW36FS
PERFORMANCE
- Lower the unique glass canopy for greater capture area
- 3 fan speeds plus 10 minute high-power operation mode
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
DESIgN
- Brushed stainless steel finish
- Welded, polished seams for a flawless design
- Premium electronic touch controls
- Elegantly curved glass canopy
CAPACITY
- 600 CFM Integrated Blower included
MASTERPIECE
HGEW36FS – 36-Inch
SPECIFICATIONS
Available Hood Widths 36"
Blower600 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights8 ft. to 9
Dishwasher Safe Filters 1 Mesh
Halogen Lighting2
3
/4 ft.
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe stainless-frame mesh filters
- Dimmer lighting – for those hours after a late meal
- Unique canopy pivots up – offering increased head room
- Built-in Clean Filter Reminder light
- Telescopic chimney – adjustable at installation
- Delayed shutoff tackles lingering odors for up to 10 minutes
- Hood includes filters, lights, backdraft damper and transition
162
ACCESSORIES
CHIMXHgE – Chimney Extension
- For use with HGEW__FS
- Stainless steel chimney hood extension
for up to 12-foot ceiling applications
- Extension replaces upper section of
standard chimney extension
Page 32
VENTILATION PIVOT-LIFT gLASS CANOPY HOOD (36")
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional specifications.
Hood installation height above a cooktop can vary. To obtain the
necessary installation height above a Thermador non-professional
gas, electric, or induction cooktop, consult the appliance's
installation manual.
Thermador Chimney Wall Hoods must be mounted on a wall.
This hood is designed to be used for vertical discharge.
A 600 CFM integrated blower is included.
VENTILATION — CHIMNEY WALL HOODS
Model: HgEW36FS
Installation Note: This product ships with two transport
brackets to hold the moveable canopy in place during
shipping and installation. After installation, be sure to
remove the brackets to operate the pivot-lift glass canopy.
1.800.735.4328 | THERMADOR.COM
163
Page 33
VENTILATION CHIMNEY WALL DRAWER HOOD (36")
Model: HDDW36FS
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- 45% increase in capture area when hood is extended
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
- Sound insulation mats make this hood barely audible
- Dimmer lighting – for those hours after a late meal
- Unique sliding stainless steel canopy can be pushed back
against the wall to increase the capture area
- Built-in Clean Filter Reminder light
- Telescopic chimney – adjustable at installation
- Delayed shutoff tackles lingering odors for up to 10 minutes
- Hood includes filters, lights, backdraft damper and transition
SPECIFICATIONS
Available Hood Widths 36"
Blower600 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights7
Dishwasher Safe Filters 4 Mesh
Halogen Lighting4
3
/4 ft. to 9 1/2 ft.
ACCESSORIES
CHIMXHDD – Chimney Extension
- For use with HDDW__FS
- Stainless steel chimney hood extension
for up to 12-foot ceiling applications
- Extension replaces upper section of
standard chimney extension
164
Page 34
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional specifications.
Hood installation height above a cooktop can vary. To obtain the
necessary installation height above a Thermador non-professional
gas, electric, or induction cooktop, consult the appliance's
installation manual.
Thermador Chimney Wall Hoods must be mounted on a wall.
This hood is designed to be used for vertical discharge.
A 600 CFM integrated blower is included.
VENTILATION CHIMNEY WALL DRAWER HOOD (36")
VENTILATION — CHIMNEY WALL HOODS
Model: HDDW36FS
Installation Note: This product ships with two transport
brackets to hold the moveable canopy in place during
shipping and installation. After installation, be sure to
remove the brackets to operate the sliding drawer canopy.
1.800.735.4328 | THERMADOR.COM
165
Page 35
166
MODEL HGSI42TS SHOWN WITH 36-INcH INDUcTION cOOKTOP cIS365GB AND DISHWASHER DWHD410GFM
Page 36
VENTILATION
ISLAND HOODS
VENTILATION — ISLAND HOODS
Thermador Island Hoods put the finishing touches on your
cooking system, with excellent overall efficiency in drawing away
smoke, moisture and heat. The adjustable chimney height is
perfect over island cooktop or range installations. Dishwasher
safe aluminum mesh filters make cleanup easy.
1.800.735.4328 | THERMADOR.COM
167
Page 37
ISLAND HOODS FEATURES & BENEFITS
HALOgEN LIgHTS
Bright halogen lighting
spotlights your best recipes.
(HGSI42TS only)
POWERFULLY QUIET™ OPERATION
Steam, smoke and odors are no problem for Thermador's ducted
ventilation systems.
TIME-TO-CLEAN-FILTER LIgHT
Easy clean-up: All Thermador ventilation filters are dishwasher
safe, and many hoods feature a built-in Time-to-Clean-Filter
reminder light. (HNI42YS, HNI48YS, HNI54YS only)
EXTERIOR CONTROLS
Easy-to-clean, easy-to-use push-button controls put accuracy
at your fingertips.
PLANNING INFORMATION
DISHWASHER SAFE FILTERS
Dishwasher-safe anodized aluminum mesh filters for easy-clean
maintenance.
DELAYED SHUTOFF
For the greatest efficiency, our Professional ventilation models
include delayed shutoff to tackle lingering odors. (HNI42YS,
HNI48YS, HNI54YS only)
168
MODEL OPTIONS
Thermador Professional Series Island Hoods are
available in 42-inch, 48-inch and 54-inch widths and
feature a stainless steel design. A Masterpiece®
Series Island Hood is available in a 42-inch width
and features a stainless steel design with an elegant
glass canopy. All of our island hoods are adjustable
to suit a range of ceiling heights.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Wall Hood is properly installed and grounded by a
qualified technician. Installation, electrical connections and grounding must
comply with all applicable local codes.
MODELREQUIRED CIRCUIT BREAKER
120 V AC, 60 Hz
HNI42YS, HNI48YS,
HNI54YS, HGSI42TS
15 Amp
Page 38
ISLAND HOODS PLANNINg INFORMATION
VENTILATION — ISLAND HOODS
INSTALLATION CONSIDERATIONS
The information in this design guide provides
key features, product dimensions and installation
specifications. Before installing a Thermador
Island Hood, be sure to verify the dimensions and
electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
Thermador Island Hoods may be installed above a
Thermador Cooktop or Range to create a convenient
cooking center. Refer to the appropriate section for
additional specifications.
HOOD WIDTH
The hood width should be no less than the width of
the cooking surface. Where space is not restricted,
a wider hood can be used to increase your capture
area. Island installations require a greater capture
area; therefore the hoods used should overlap your
cooking surface by a minimum of 3" to 6" on
either side.
DISTANCE FROM COOKINg SURFACE
Proper mounting height is very important. If a
hood is mounted too low, it may be difficult to
cook and be unsafe. If a hood is mounted too high,
performance may be compromised. For optimal
performance, the distance from the cooking surface
to the bottom of the hood should be a minimum
of 30", unless otherwise noted. Please refer to the
installation manual for each hood and cooktop/
range model for proper hood mounting heights.
AVAILABLE CEILINg HEIgHT
The standard ceiling height can vary from region to
region and in homes built in different eras. Ceiling
heights, even in the same room, can sometimes vary
by as much as several inches. Kitchen ceiling heights
can vary between 7'6" (or 90") to over 10' (or 120").
Before selecting a Thermador Hood, check the
available installation space and any extra space
that may remain after proper installation of a
hood and cooktop or range. This extra space can
be filled using Thermador’s stainless steel duct
cover accessories. The space can also be adjusted
by raising or lowering your hood within the
recommended range (typically 30" to 36" above
the cooking surface).
CHOOSINg THE CORRECT BLOWER
A variety of interior and exterior blower options
(Remote, Inline or Integral) are available for
Thermador’s Professional Series Island Hoods. If the
unit you have selected does not have a blower, one
can be purchased separately. Blower selection will
vary based on the volume of air that needs to be
moved and the length and location of the duct run.
For long duct runs with multiple turns and bends,
consider using a more powerful blower. For the most
efficient air flow exhaust, use a straight run or as few
elbows as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these blowers can be
mounted on the roof or exterior wall of your home. An exterior installation may
be more appealing to reduce noise in the kitchen.
Inline Blowers (VTI Series)
To minimize noise in the kitchen, these blowers are mounted along the
duct line anywhere between the kitchen and the exterior wall. If you have
easy access to your duct line (in an attic, for example), this may be an appealing
option.
Integral Blowers (VTN Series)
These blowers are purchased separately and integrated into the hood or onto
the downdraft unit at the time of installation. This option allows you to select
your ideal hood with the exact power you require.
CHOOSINg THE RIgHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional Gas
Cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU, choose
a blower with a minimum of 100 CFM per 12" of cooktop width.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with airflow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a relatively small kitchen, a
hood with 400 to 600 CFM may be adequate ventilation for the cooking space.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a
good alternative.
• High heat cooking or aromatic foods may require additional CFM. Increasing
capture area by 3" on each side is also a recommended way to address
this issue.
LENgTH AND SIzE OF DUCTWORK
Do not use flexible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the fewest
turns possible.
Proper performance is dependent upon proper ducting. Use a qualified and
trained installer. Local building codes may require the use of make-up air
systems when using ducted ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale. Consult your HVAC
professional for specific requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more static
pressure, therefore increasing your equivalent duct run.
WARRANTY
Limited warranty parts and labor (1 year)
See page 294 for additional warranty details.
1.800.735.4328 | THERMADOR.COM
169
Page 39
VENTILATION ISLAND HOOD (42"/48"/54")
Models: HNI42YS, HNI48YS, HNI54YS
PROFESSIONAL
HNI42YS – 42-Inch
HNI48YS – 48-Inch
HNI54YS – 54-Inch
SPECIFICATIONS
Available Hood Widths 42", 48", 54"
BlowerSold Separately—
Duct Size at Discharge8" Round
Ducting DirectionVertical
Ceiling Heights8
Dishwasher Safe Filters Mesh
Halogen Lighting4
See Blower Options Table
1
/4 ft. to 10 ft.
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
DESIgN
- Brushed stainless steel finish
- Welded, polished seams for a flawless design
- 27-inch depth hood is a perfect companion to the Pro Grand®
professional range
- Premium electronic touch controls
CONVENIENCE
- Fluorescent lighting brightens the entire work space
- Dishwasher safe aluminum mesh filters
- After 40 hours of operation, the Clean Filter button illuminates
- Telescopic chimney – adjustable at installation
- Auto start High Heat Sensor
- Delayed shutoff tackles lingering odors for up to 10 minutes
- Blowers sold separately
- Choose from Inline or Remote Blowers
- Hood includes filters, lights, backdraft damper and transition
170
Page 40
INSTALLATION OPTIONS
Thermador Professional Series Island Hoods may be installed
above a Thermador Professional Cooktop or Range to create a
convenient cooking center. Refer to the appropriate section for
additional specifications.
Hood installation height above a cooktop can vary. To obtain
the necessary installation height above a Thermador Cooktop or
Range, consult the appliance's installation manual.
Thermador Island Hoods are suspended from the ceiling. These
hoods are designed to be used for vertical discharge. A blower
must be purchased separately.
BLOWER OPTIONS
REMOTE
VTR1030D – 1000 CFM Use RFPLT1000
in roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000
in roof-mount applications
INLINE
VTI1010D – 1000 CFM
See page 145 for further details.
VENTILATION ISLAND HOOD (42"/48"/54")
VENTILATION — ISLAND HOODS
Models: HNI42YS, HNI48YS, HNI54YS
REMOTE (Mounted to roof or external wall)
VTR1030D 1000 CFM
INLINE (Mounted between kitchen and external wall)
VTI1010D 1000 CFM
VTR1330E 1300 CFM
REMOTE BLOWER ACCESSORIES
RFPLT1000 – Roofplate Material
For use with Remote Blowers VTR1030D and VTR1330E
Combinations
RoofplateRemote Blower
RFPLT1000VTR1030D, VTR1330E
Overall Dimensions
Model No.ABCDuct Size
RFPLT10009
3
/8"12"11 1/8"10"
1.800.735.4328 | THERMADOR.COM
171
Page 41
VENTILATION ISLAND HOOD WITH BLOWER (42")
Model: HgSI42TS
PERFORMANCE
- 3 fan speeds
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
DESIgN
- Brushed stainless steel finish
- Welded, polished seams for a flawless design
- Easy to operate control buttons
CAPACITY
- 400 CFM Integrated Blower included
MASTERPIECE
HGSI42TS - 42-Inch
SPECIFICATIONS
Available Hood Widths 42"
Blower400 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights8 ft. to 10 ft.
Dishwasher Safe Filters Mesh
Halogen Lighting4
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe aluminum mesh filters
- Telescopic chimney – adjustable at installation
- Hood includes filters, lights, backdraft damper and transition
172
Page 42
INSTALLATION OPTIONS
Thermador Masterpiece® Series Island Hoods may be installed
above a Thermador non-professional gas, electric, or induction
cooktop to create a convenient cooking center. Refer to the
appropriate section for additional specifications.
Hood installation height above a cooktop can vary. To obtain
the necessary installation height above a Thermador Cooktop or
Range, consult the appliance's installation manual.
Thermador Island Hoods are suspended from the ceiling. These
hoods are designed to be used for vertical discharge. A 400 CFM
blower is included.
VENTILATION ISLAND HOOD WITH BLOWER (42")
VENTILATION — ISLAND HOODS
Model: HGSI42TS
1.800.735.4328 | THERMADOR.COM
173
Page 43
174
48-Inch Pro Grand® ranGe Shown wIth cuStom VentIlatIon InSert
Page 44
VENTILATION
CUSTOM INSERTS
VENTILATION — CUSTOM INSERTS
Use Thermador Custom Hood Inserts within custom hood
applications to create a seamless design with wall or island
applications. These inserts efficiently and quietly remove odor
and steam. Inserts are available for both professional and
non-professional applications.
1.800.735.4328 | THERMADOR.COM
175
Page 45
CUSTOM INSERTS FEATURES & BENEFITS
REMOTE VENTILATION
CONTROL
Remote control for customized
ventilation applications is easy to
use and has a sophisticated and
professional style. (VCI230DS,
VCI236DS, VCI248DS only)
HALOGEN LIGHTS
Bright halogen lighting
spotlights your best recipes.
CUSTOM HOOD INSERT
Specially designed for professional custom hood applications to create
a concealed ventilation system.
TIME-TO-CLEAN-FILTER LIGHT
Easy cleanup: All Thermador ventilation filters are dishwasher safe,
and many hoods feature a built-in Time-to-Clean-Filter reminder light.
(VCI230DS, VCI236DS, VCI248DS only)
DELAyED SHUTOFF
For the greatest efficiency, our Professional ventilation models include
delayed shutoff to tackle lingering odors. (VCI230DS, VCI236DS,
VCI248DS only)
PUSH BUTTON CONTROLS
Concealed three-speed, push-button controls are easy to use.
(Professional Series only)
PLANNING INFORMATION
MESH FILTERS
Aluminum mesh filters with
stainless steel frame maximize
grease capture without affecting
flow and feature a quick release
latch for easy clean-up.
176
MODEL OPTIONS
Thermador Custom Hood Inserts are available for
both professional and non-professional applications.
The Professional Series Custom Hood Inserts are
available in 30-inch, 36-inch and 48-inch widths.
The Masterpiece® Series Custom Hood Inserts are
available in 21-inch (for 30-inch wide installations)
and 29-inch (for 36-inch wide installations).
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Custom Insert is properly installed and grounded by
a qualified technician. Installation, electrical connections and grounding must
comply with all applicable local codes.
MODELREQUIRED CIRCUIT BREAKER
120 V AC, 60 Hz
VCI230DS, VCI236DS,
VCI248DS, VCI21CS,
VCI29CS
15 Amp
Page 46
CUSTOM INSERTS PLANNING INFORMATION
VENTILATION — CUSTOM INSERTS
INSTALLATION CONSIDERATIONS
The information in this design guide provides
key features, product dimensions and installation
specifications. Before installing a Thermador Custom
Hood Insert, be sure to verify the dimensions and
electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
Professional Custom Series Hood Inserts are designed
for installation with all professional-style cooktops and
ranges. Masterpiece® Custom Series Hood Inserts are
designed for installation with non-professional gas,
electric or induction cooktops. Refer to the appropriate
section for additional specifications.
HOOD WIDTH
The hood width should be no less than the width of the
cooking surface. Where space is not restricted, a wider
hood can be used to increase your capture area.
DISTANCE FROM COOKING SURFACE
Proper mounting height is very important. If a hood
is mounted too low, it may be difficult to cook and be
unsafe. If a hood is mounted too high, performance
may be compromised. For optimal performance, the
distance from the cooking surface to the bottom of the
hood should be a minimum of 30", unless otherwise
noted. Please refer to the installation manual for each
hood and cooktop/range model for proper hood
mounting heights.
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options
Remote, Inline or Integral) are available for Thermador’s
Professional and Masterpiece® Series Hoods. If the unit
you have selected does not have a blower included,
one can be purchased separately. Blower selection
will vary based on the volume of air that needs to be
moved and the length and location of the duct run. For
long duct runs with multiple turns and bends, consider
using a more powerful blower. For the most efficient
air flow exhaust, use a straight run or as few elbows as
possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation,
these blowers can be mounted on the roof or exterior
wall of your home. An exterior installation may be more
appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are
mounted along the duct line anywhere between the
kitchen and the exterior wall. If you have easy access to
your duct line (in an attic, for example), this may be an
appealing option.
CHOOSING THE RIGHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional Gas
Cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,
choose a blower with a minimum of 100 CFM per 12" of cooktop width.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with airflow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 400 to 600 CFM may be adequate ventilation for the
cooking space.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a
good alternative.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
LENGTH AND SIzE OF DUCTWORK
Do not use flexible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
Proper performance is dependent upon proper ducting. Use a qualified and
trained installer. Local building codes may require the use of make-up air
systems when using ducted ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale. Consult your
HVAC professional for specific requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
Installation Note: Professional Rangetops and Ranges require that minimum
distances be maintained from the cooking surface to combustible materials
(i.e. a wood covering around the insert). These minimum distances range from
30" to 40" and can vary from product to product and by manufacturer. Refer
to the installation manual of the rangetop or range prior to the design and
installation of the custom hood insert.
WARRANTy
Limited warranty parts and labor (1 year)
See page 294 for additional warranty details.
Integral Blowers (VTI series)
These blowers are purchased separately and integrated
into the hood or onto the downdraft unit at the time of
installation. This option allows you to select your ideal
hood with the exact power you require.
1.800.735.4328 | THERMADOR.COM
177
Page 47
VENTILATION CUSTOM INSERT (30"/36"/48")
Models: VCI230DS, VCI236DS, VCI248DS
PROFESSIONAL
VCI230DS – 30-Inch
VCI236DS – 36-Inch
VCI248DS – 48-Inch
Custom hood insert for use within wall or island custom
hood applications
PERFORMANCE
- 3 fan speeds
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
- Deep capture area allows for efficient capture of smoke and steam
DESIGN
- Suitable for wall or island applications
- Stainless steel button controls
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe aluminum mesh filters
- All-stainless steel baffle filters are available
- Built-in Clean Filter Reminder light
- Delayed shutoff tackles lingering odors for up to 10 minutes
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
SPECIFICATIONS
Available Hood Widths 30", 36", 48"
BlowerSold Separately—
See Blower Options Table
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher Safe Filters Mesh (Baffle filters sold as
an accessory)
Halogen Lighting30", 36" – 2 Bulbs
48" – 4 Bulbs
ACCESSORIES
BAFFLT – Baffle Filters
(30"/36"/48") BAFFLT30/BAFFLT36/BAFFLT48
- For use with VCI2__DS
- Stainless steel finish
- Unique low profile design maximizes
grease capture
- Dishwasher safe for easy clean-up
REMOTE CONTROL PANELS
VCI2REMFS/VCI2REM
- Overall size: 14
- For use with VCI2__DS
- Stainless steel finish
- Cable-connected to blower and hood controls
- Choose from one of two unique styles
VCI2REMVCI2REMFS
LINER – Custom Hood Liners
(30"/36"/48") LINER30/LINER36/LINER48
- For use with VCI2__DS
- Stainless steel custom hood liners
to protect the exterior base of
custom insert
- Custom hood liner completes
custom insert installation
1
14 1/2"
/2" W x 4 1/2" H
4 1/2"
178
Page 48
VENTILATION CUSTOM INSERT (30"/36"/48")
INSTALLATION OPTIONS
Thermador Custom Hood Inserts within custom hood applications create a
seamless design with wall or island applications.
Thermador Professional Series Custom Hood Inserts may be installed above
a Thermador Professional Cooktop or Range to create a convenient cooking
center. Refer to the appropriate section for additional specifications.
Hood installation height above a cooktop can vary. Professional Rangetops
and Ranges require that minimum distances be maintained from the cooking
surface to combustible materials (i.e. a wood covering around the insert). These
minimum distances range from 30" to 40" and can vary from product to product
and by manufacturer. Refer to the installation manual of the rangetop or range
prior to the design and installation of the custom hood insert.
These hoods are designed to be used for vertical discharge. A blower must be
purchased separately.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFMUse RFPLT600 in roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000 in roof-mount applications
INLINE
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEGRATED
VTI610D – 600 CFMInline blower can be used for an integrated
solution
See page 145 for further details.
VENTILATION — CUSTOM INSERTS
Models: VCI230DS, VCI236DS, VCI248DS
Installation Note: Professional Rangetops and Ranges require
that minimum distances be maintained from the cooking
surface to combustible materials (i.e. a wood covering around
the insert). These minimum distances range from 30" to 40"
and can vary from product to product and by manufacturer.
Refer to the installation manual of the rangetop or range prior
to the design and installation of the custom hood insert.
REMOTE (Mounted to roof or external wall)
VTR630D 600 CFM
INLINE (Mounted between kitchen and external wall)
VTI610D 600 CFM
VTR1030D 1000 CFM
VTI1010D 1000 CFM
VTR1330E 1300 CFM
INTEGRAL (Mounted on hood)
VTI610D 600 CFM
REMOTE BLOWER ACCESSORIES
RFPLT600, RFPLT1000 – Roofplate Material
For use with Remote Blowers VTR630D, VTR1030D
and VTR1330E
Combinations
RoofplateRemote Blower
RFPLT600VTR630D
RFPLT1000VTR1030D, VTR1330E
Overall Dimensions
Model No.ABCDuct Size
RFPLT6007
RFPLT1000 9
1
/2" 8 1/2" 9 1/4"6"
3
/8"12"11 1/8"10"
1.800.735.4328 | THERMADOR.COM
179
Page 49
VENTILATION CUSTOM INSERT WITH BLOWER (21"/29")
Models: VCI21CS, VCI29CS
PERFORMANCE
- 3 fan speeds plus 10 minute high-power operation mode
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
DESIGN
- Suitable for wall or island applications
- Slide control for easy power adjustments
CAPACITy
MASTERPIECE
VCI21CS – 21-Inch
VCI29CS – 29-Inch
Custom hood insert for use within custom hood applications
- 400 CFM Integrated Blower included
CONVENIENCE
- Halogen lighting spotlights your best recipes
- Dishwasher safe aluminum mesh filters
- Hood includes filters, lights, backdraft damper and transition
SPECIFICATIONS
Available Hood Widths 21", 29"
Installation Width21" Model – Up to 30" Wide
Blower400 CFM Blower Included
Duct Size at Discharge6" Round
Dishwasher Safe Filters 2 Mesh
Halogen Lighting2
29" Model – Up to 36" Wide
180
Page 50
VENTILATION CUSTOM INSERT WITH BLOWER (21"/29")
INSTALLATION OPTIONS
Thermador Custom Hood Inserts within custom hood
applications create a seamless design with wall or island
applications.
Thermador Masterpiece® Series Custom Hood Inserts may be
installed above a Thermador non-professional gas, electric, or
induction cooktop up to 36-inches wide to create a convenient
cooking center. Refer to the appropriate section for additional
specifications.
Hood installation height above a cooktop can vary. To obtain
the necessary installation height above a Thermador Cooktop,
consult the appliance's installation manual.
These hoods are designed to be used for vertical discharge.
A 400 CFM Blower is included.
VENTILATION — CUSTOM INSERTS
Models: VCI21CS, VCI29CS
1.800.735.4328 | THERMADOR.COM
181
Page 51
182
DOWNDRAFT MODEL UCVM36FS SHOWN WITH 36-INCH INDUCTION COOKTOP CIT365GM
Page 52
VENTILATION
DOWNDRAFT
VENTILATION — DOWNDRAFT
If you prefer a concealed look, choose a Thermador Downdraft
Ventilation Unit, which offers space efficiency when a hood is not
preferred. A full face filter combines a filter with splatter shield
in one easy-to-remove, dishwasher-safe element. Thermador
invented the first retractable downdraft, and was also the first
to introduce a recirculation option for downdrafts—making
ventilation possible in any kitchen.
1.800.735.4328 | THERMADOR.COM
183
Page 53
DOWNDRAFT FEATURES & BENEFITS
FULL 13-INCH RISE
With an over 13-inch intake, the UCVM rises well above even the tallest
pans. This protects against splatters when cooking and provides better
performance in capturing steam and smoke—even from the front burners.
DOWNDRAFT RECIRCULATION OPTION
Downdraft recirculation is now available for island or wall applications.
Combine the performance of the UCVM Downdraft with the odor- and
grease-capturing filters in the Recirculation Module for the perfect
ventilation combination for anywhere in your kitchen.
FULL FACE FILTERS
Full-face filters combine a filter with a splatter shield in one easy-toremove, dishwasher-safe element. These filters maximize grease capture
without affecting airflow.
PLANNING INFORMATION
MODEL OPTIONS
Thermador Downdraft Hoods are available in 30
and 36-inch widths to fit your kitchen plans and are
meticulously crafted for both function and design. Be
sure to reference the correct model information in this
design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Downdraft Hood is properly
installed and grounded by a qualified technician.
Installation, electrical connections and grounding must
comply with all applicable local codes.
REQUIRED
MODEL
UCVM30FS, UCVM36FS15 Amp
INSTALLATION CONSIDERATIONS
The information in this design guide provides key
features, product dimensions, cutouts and installation
specifications. Before installing a Thermador Downdraft
Hood, be sure to verify the cutout dimensions and
electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
CIRCUIT BREAKER
120V AC, 60 Hz
Thermador Downdraft Hoods may be installed in a wall or island behind a
Thermador non-professional gas, electric or induction cooktop to create a
convenient cooking center. Refer to the appropriate section for additional
specifications.
HOOD WIDTH
Downdraft ventilation units should be the same width as the cooking surfaces
they are ventilating.
CHOOSINg THE CORRECT BLOWER
A variety of interior and exterior blower options (Remote, Inline or Integral)
are available for Thermador’s Downdraft Hoods. If the unit you have selected
does not have a blower, one can be purchased separately. Blower selection
will vary based on the volume of air that needs to be moved and the length
and location of the duct run. For long duct runs with multiple turns and
bends, consider using a more powerful blower. For the most efficient air flow
exhaust, use a straight run or as few elbows as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these blowers can be
mounted on the roof or exterior wall of your home. An exterior installation
may be more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are mounted along the
duct line anywhere between the kitchen and the exterior wall. If you have
easy access to your duct line (in an attic, for example), this may be an
appealing option.
Integral Blowers (VTN series)
These blowers are purchased separately and integrated into the hood or onto
the downdraft unit at the time of installation. This option allows you to select
your ideal hood with the exact power you require.
184
Page 54
DOWNDRAFT FEATURES & BENEFITS
VENTILATION — DOWNDRAFT
CHOOSING THE RIGHT CFM
The power of the cooktop, measured in BTU, is
perhaps the most important factor in determining
CFM needs for a hood. Professional Gas Rangetops
generally should have 1 CFM for every 100 BTU.
You should also consider the cooking space and
cooking style of your client.
• More demanding cooks usually require more
exhaust capacity to handle moisture generated
by boiling large pots of water or the grease
and smoke resulting from grilling or frying. This
cooking style could require a hood or downdraft
system with airflow of 600 to 1,300 CFM.
• For those who are used to preparing quick
meals in a relatively small kitchen, a hood with
600 CFM may be adequate ventilation for the
cooking space.
• If the cooking surface is in a peninsula or island, a
larger capacity hood can provide better capture
when there are cross currents and when the
hood needs to be mounted higher. Downdraft
ventilation systems are also a good alternative.
• High heat cooking or aromatic foods may require
additional CFM. Increasing capture area by 3" on
each side is also a recommended way to address
this issue.
LENGTH AND SIZE OF DUCTWORK
Do not use flexible duct; it creates back pressure/air
turbulence and reduces performance.
BLOWER OPTIONS
REMOTERequires CV2T6 Transition
VTR630D – 600 CFMUse RFPLT600 in roof-mount applications
VTR1030D – 1000 CFMUse RFPLT1000 in roof-mount applications
INLINERequires CV2T6 Transition
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEGRATED
VTN600CV2C – 600 CFM
See page 145 for further details.
REMOTE (Mounted to roof or external wall)INTEGRAL (Mounted on hood)
VTR630D 600 CFM VTR1030D 1000 CFM
INLINE (Mounted between kitchen and external wall)
VTI610D 600 CFMVTI1010D 1000 CFM
VTN600CV2C 600 CFM
Straight runs and gradual turns are best. Use the
shortest route with the fewest turns possible.
Proper performance is dependent upon proper
ducting. Use a qualified and trained installer. Local
building codes may require the use of make-up
air systems when using ducted ventilation systems
greater than specified CFM of air movement. The
specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in
your area.
If using a 10" duct, Thermador recommends not
exceeding 150 feet of duct. Transitions, elbows and
wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent
duct run.
WARRANTY
Limited warranty parts and labor (1 year)
See page 294 for additional warranty details.
REMOTE BLOWER ACCESSORIES
RFPLT600, RFPLT1000 – Roofplate Material
For use with Remote Blowers VTR630D and VTR1030D
Combinations
RoofplateRemote Blower
RFPLT600VTR630D
RFPLT1000VTR1030D
Overall Dimensions
Model No.ABCDuct Size
RFPLT6007
RFPLT1000 9
CV2T6 TRANSITION
Transition piece required for installation of inline and
remote blowers – downdraft applications only
1
/2" 8 1/2" 9 1/4"6"
3
/8"12"11 1/8"10"
1.800.735.4328 | THERMADOR.COM
185
Page 55
VENTILATION DOWNDRAFT (30"/36")
Models: UCVM30FS, UCVM36FS
MASTERPIECE
UCVM30FS – 30-Inch
UCVM36FS – 36-Inch
SPECIFICATIONS
Available Hood Widths 30", 36"
BlowerSold Separately—
See Blower Options Table
Duct Size at Discharge6" Round
Ducting DirectionDown, Left or Right
Dishwasher Safe Filters Full-Face Mesh
PERFORMANCE
- 3 fan speeds
- Filters are highly efficient at capturing grease
- Powerfully quiet ventilation systems
DESIGN
- Suitable for wall or island applications
- Brushed stainless steel finish
- Easy to operate control buttons
CAPACITY
- Downdraft rises over 13 inches to capture steam from the
tallest pots
- Downdraft recirculation possible with module RECIRC36DF
CONVENIENCE
- Dishwasher safe full-face filters also act as a splatter shield
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
186
ACCESSORIES
RECIRC36DF – Recirculation Kit
- For use with UCVM__FS
- Comes complete with 2 charcoal filters, 2 venting grids, and ducting
to transition to integrated blower (blower sold separately)
- For toe kick heights of 4 inches or taller
- Wall or island applications
- Easily mounts to integrated blower (VTN600CV2C) under cooktop
- Toe kick/socket can be vented in any direction
- Mounts to base of cabinet; recesses into toe kick
- To be used only with Thermador downdraft and integrated blower
REPLACEMENT CHARCOAL FILTERS
Sold Separately as a Service Item (For use with Recirculation Module)
3/
ø 5
4
1/
8
18
”
1/
1
8
”
4”
1/
8
5
”
1/
8
17
”
5/
1
8
”
1/
4
20
”
1/
2
3
”
”
7/
8
19
”
1/
8
19
”
1/
4
21
”
Page 56
INSTALLATION OPTIONS
The Thermador Downdraft Hood System is available in 30-inch
or 36-inch widths. It is intended for installation with Thermador
non-professional gas, electric or induction cooktops only.
A Recirculation Kit (RECIRC__FS) can be purchased separately and
used in conjunction with the Integral Blower if ducting to the outside
is not a viable option. Refer to the appropriate section for additional
specifications.
These hoods are designed to be used for vertical or horizontal discharge.
VENTILATION DOWNDRAFT (30"/36")
VENTILATION — DOWNDRAFT
Models: UCVM30FS, UCVM36FS
1
/4"
min.
1
/8"
9
5
21
/8"
1
/4"
3
wide 31": 28
wide 37": 34
BT
min.
1
/4"
1
/4"
2
1
/4"
1
/16"
5
1
/4"
2
Dimension
depends
on Countertop
6"
Dimension
depends
on Cabinet
3
14
/4"
Blower/Duct
Transition Box
ø6"
Vent
5
/16"
6
10"
Center Line (CL)/
Cutout and
Overall
/2"
Dimensions
1
2
/4"
1
3
/8"
3
/8"
Cutout and
Overall
Dimensions
SB
Plumbline
Point "P"
1
15
/2"
CL
3
/4"
9
CL
A
3
/8"
6
1
CL
7
/8"
B
B
A
1.800.735.4328 | THERMADOR.COM
187