Thermador VTN 1000Q Installation Instructions

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: Save these instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
SAFETY WARNING: Before servicing or cleaning unit, switch off power at service panel and
IMPORTANT SAFETY INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS.
A. Installation Work and Electrical
Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes & Standards, Including Fire-Rated Construction.
READ AND SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
HOOD VENTILATORS VTN 1000Q
lock service disconnecting means to prevent power from being switched on accidentally. When service disconnecting means cannot be locked, attach a tag to the service panel to indicate power has been switched off for maintenance.
B. Sufficient air is needed for proper
combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Condi– tioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall
or ceiling, do not damage electrical wiring and other hidden utilities.
D. To properly exhaust air, be sure
to duct air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
“WARNING” TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
RECOMMENDED FOR USE WITH THERMADOR PROFESSIONAL WALL HOOD ONLY.
1. Check duct size from your hood to the outside. It should be 10" diameter for good air exhaust.
2. Run four (4) # 10 x 1 long screws (provided with your hood) halfway through the rough-in plate into the fram­ing, as shown in Figure 1.
3. Install the ventilator assembly by aligning the four (4) screws on the rough-in plate with the key holes on the ventilator plate and, at the same time, push the assem­bly towards the wall. Make sure all four (4) screws are engaged securely in the small end of the key holes.
4. Tighten the four (4) screws in the key holes. Drive two (2) additional mounting screws on the side of the ven­tilator plate into the framing.
5. Plug in Molex plug to matching plug in hood.
CAUTION: These two additional screws
must be installed on the ventillator plate.
FIGURE 1
Ventillator Assembly
Additional Screws
Power Supply
Conduit Box
Molex Plug Connector
KITCHEN VENTILATION TIPS
1. Cooking appliances such as ranges, cooktops, barbecues,
grills, etc., require adequate ventilation. Hoods should be large enough and cooking appliances located so that the hood overhangs the cooking surface as much as possible.
2. Consult a competent Kitchen Designer or Ventilation Engineer for proper hood size and C.F.M. requirements.
3. Locate cooking area for minimum cross drafts away from doors and windows, when possible.
6. WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
4. CAUTION: -Vent unit to outside of building.
5. Make up air may be needed, to eliminate air pulled down fireplace, furnace and other openings, for proper hood installation.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649.
UL LISTED #157J FILE #E21958
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328
ECO 71566 • 19-11-800G • © Thermador Corporation • Litho U.S.A. 11/00