Thermador VM410 User Manual

INSTALLATION INSTRUCTIONS

HOODVENTILATORVM410

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.

IMPORTANT: Save these instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Installation Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVETHESE INSTRUCTIONS

WARNING:TOREDUCE THE

securely fasten a prominent warning

RISK OF FIRE, ELECTRIC

device, such as a tag, to the service

SHOCK, OR INJURY TO PER-

panel.

SONS,OBSERVETHEFOLLOW-

C. Installation work and electrical

ING:

wiring must be done by qualified per-

CAUTION: FOR GENERAL

sons in accordance with all applicable

VENTILATING USE ONLY. DO

codes & standards, including fire-rated

NOT USE TO EXHAUST HAZ-

construction.

ARDOUS OR EXPLOSIVE MA-

D. Sufficient air is needed for proper

TERIALS OR VAPORS.

combustion and exhausting of gases

A. Use this unit only in the manner

through the flue (chimney) of fuel burn-

intended by the manufacturer. If you

ing equipment to prevent backdrafting.

have questions, contact the manufac-

Follow the heating equipment manufac-

turer.

turers guideline and safety standards

B. Before servicing or cleaning unit,

such as those published by the National

switch power off at service panel and

Fire Protection Association (NFPA), the

lock the service disconnecting means

American Society for Heating, Refrig-

to prevent power from being switched

eration and Air Conditioning Engineers

on accidentally. When the service dis-

(ASHRAE), and the local code authori-

connecting means cannot be locked,

ties.

E.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

F.CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.

G.WARNING – TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

H.This appliance has a polararized plug (one blade wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.Always turn hood ON when cooking at high heat or when cooking flaming foods.

C.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

D.Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

A.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE

DEPARTMENT.

B.NEVER PICK UP A FLAMING PAN – You may be burned.

C.DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

D.Use an extinguisher ONLY if:

1)You have a Class ABC extinguisher, and you already know how to operate it.

2)The fire is small and contained in the area where it started.

3)The fire department is being called.

4)You can fight the fire with your back to an exit.

PAGE 1

Thermador VM410 User Manual

RECOMMENDED FOR USE OVER CONVENTIONAL DOMESTIC GAS AND ELECTRIC RANGES AND COOKTOPS.

IFOR USE WITH H/HB/HT HOOD SERIES:

1.Remove the Z-shaped bracket from the VM410 ventilator and discard.

2.Remove the blower mounting bracket from the VM410 and replace with a longer bracket provided with the hood. (See Fig.1).

3.Insert one end of the blower mounting bracket into the ventilator mounting channel located in the rough-in plate, and slip the other end of the bracket into the well stud (located in the rough-in plate) and tighten it with the flange nut (provided with the hood). (See Fig. 2).

4.Plug the ventilator cord into the receptacle located inside the hood assembly.

5.Attach the transition (3-1/4" x 10") to the top of the rough-in plate, using the two shipping screws. Seal all joints between the rough-in plate and the transition with duct tape.

FIGURE 1

Bracket

VM410

FIGURE 2

H/HB/HT HOOD SERIES

Hex Nut

II FOR USE WITH H55/H64/H65 AND VCH3/ VCH8 / VCH9:

This ventilator unit designed to be used with Thermador “Designer II” Kitchen Exhaust Hood H55, Thermador “Masterpiece “ Kitchen Exhaust H64, H65, Ventilator Control Housings VCH8 or VCH9, Thrustpower II Kitchen Exhaust Hoods, and VCH3 Ventilator Control Housing.

Remove hanger rod from ventilator unit (taped to bracket) and attach to inside top of hood housing. Locate hanger rod in correct position for particular ventilator and food combination being installed. Follow instruction label inside housing.

Your New VM410 Hood Ventilator is shipped from the factory with the scroll bracket set up for vertical discharge (Fig. 3). It is easily converted for horizontal discharge (Fig. 4) for all models except the H55 Hood, VCH8 and VCH9 control housings which are designed for vertical discharge only. When converting to horizontal, the scroll bracket must be reversed as shown in Fig. 4. Install ventilator into housing by placing flange on edge of ventilator discharge into channel at rear of housing discharge opening. Pivot Ventilator upward until hanger rod snaps into slot of scroll bracket. Be sure that wing nut and washer are securely tightened.

Motor cord plugs into receptacle on hood control housing. Motor grounded to blower thru green ground wire.

SERVICE INSTRUCTIONS

1.Disconnect ventilator plug from hood housing before servicing.

2.For maximum ventilator efficiency, clean filters in hood regularly. Grease should not be allowed to accumulate on hood or ventilator surfaces.

3.Clean lint and grease from ventilator blades at regular intervals. Clean entire unit with damp cloth. Be sure no water enters motor as this can cause damage.

FIGURE 3 – VERTICAL DISCHARGE

 

Backdraft

 

 

 

 

 

Damper

 

Channel

Flange

 

 

 

 

 

 

 

Grommet

 

 

 

 

 

Hanger

 

 

 

 

 

Rod

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ventilator

 

Scroll

 

Washer

Flange

 

Wing Nut

 

Bracket

FIGURE 4 – HORIZONTAL DISCHARGE (not for Models H55, VCH8 or VCH9)

Flange

3-3/4"

 

Grommet

 

 

Hanger

 

 

 

 

Rod

Ventilator

 

Flange

Scroll

Washer Channel

Bracket

Wing Nut

Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649.

C

5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328 ECO 71532 • 19-10-273L • © 1998 Thermador Corporation • Litho U. S. A. 8/99

PAGE 2