Texas Instruments SN74ALS652A-1DW, SN74ALS652A-1DWR, SN74ALS652A-1NT, SN74ALS652ADW, SN74ALS652ADWR Datasheet

...
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Bus Transceivers/Registers
Independent Registers and Enables for A and B Buses
Multiplexed Real-Time and Stored Data
Choice of True or Inverting Data Paths
Choice of 3-State or Open-Collector Outputs to A Bus
Package Options Include Plastic Small-Outline (DW) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (NT) and Ceramic (JT) 300-mil DIPs
DEVICE A OUTPUT B OUTPUT LOGIC
SN74ALS651A,
’AS651
3 State 3 State Inverting
SN54ALS652,
SN74ALS652A,
’AS652
3 State 3 State True
’ALS653 Open Collector 3 State Inverting
SN74ALS654 Open Collector 3 State True
description
These devices consist of bus-transceiver circuits, D-type flip-flops, and control circuitry arranged for multiplexed transmission of data directly from the data bus or from the internal storage registers. Output-enable (OEAB and OEBA
) inputs are provided to control the transceiver functions. Select-control (SAB and SBA) inputs are provided to select real-time or stored data transfer. The circuitry used for select control eliminates the typical decoding glitch that occurs in a multiplexer during the transition between stored and real-time data. A low input level selects real-time data, and a high input level selects stored data. Figure 1 illustrates the four fundamental bus-management functions that can be performed with the octal bus transceivers and registers.
Data on the A or B data bus, or both, can be stored in the internal D-type flip-flops by low-to-high transitions at the appropriate clock (CLKAB or CLKBA) terminals, regardless of the select- or output-control terminals. When SAB and SBA are in the real-time transfer mode, it is possible to store data without using the internal D-type flip-flops by simultaneously enabling OEAB and OEBA
. In this configuration, each output reinforces its input. When all other data sources to the two sets of bus lines are at high impedance, each set of bus lines remains at its last state.
Copyright 1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
NC – No internal connection
SN54ALS, SN54AS. . . FK PACKAGE
(TOP VIEW)
SN54ALS, SN54AS. . . JT PACKAGE
SN74ALS, SN74AS. . . DW OR NT PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7 8 9 10 11 12
24 23 22 21 20 19 18 17 16 15 14 13
CLKAB
SAB
OEAB
A1 A2 A3 A4 A5 A6 A7 A8
GND
V
CC
CLKBA SBA OEBA B1 B2 B3 B4 B5 B6 B7 B8
321
13 14
5 6 7 8 9 10 11
OEBA B1 B2 NC B3 B4 B5
A1 A2 A3
NC
A4 A5 A6
4
15 16 17
18
A8
GND
NC
B8B7B6
OEAB
SAB
CLKAB
NC
28 27 26
25 24 23 22 21 20 19
12
A7
CLKBA
SAB
CC
V
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
description (continued)
The -1 versions of the SN74ALS651A and SN74ALS652A are identical to the standard versions except that the recommended maximum I
OL
for the -1 versions is increased to 48 mA. There are no -1 versions of the
SN54ALS652, SN54ALS653, SN74ALS653, and SN74ALS654. The SN54ALS’ and SN54AS’ families are characterized for operation over the full military temperature range
of –55°C to 125°C. The SN74ALS’ and SN74AS’ families are characterized for operation from 0°C to 70°C.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
BUS B
BUS A
BUS B
BUS A
BUS B
BUS A
BUS B
BUS A
OEAB
X L L
OEAB
LL
CLKABXCLKBAXSABXSBA
L
CLKABXCLKBAXSABLSBA
X
H
CLKAB CLKBAXSABXSBA
X
CLKAB CLKBA SAB SBA
X H
XX
X
X X
H L H or L H H
↑ ↑
OEBA
OEBA
HH
OEAB OEBA
OEAB OEBA
H or L
REAL-TIME TRANSFER
BUS B TO BUS A
REAL-TIME TRANSFER
BUS A TO BUS B
STORAGE FROM
A, B, OR A AND B
TRANSFER STORED DATA
TO A AND/OR B
3 21 1 23 2 22 1 23 2 22321
3 21 23 2 22 3 21 1 2 22
1
23
Pin numbers are for the DW, JT, and NT packages.
Figure 1. Bus-Management Functions
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
FUNCTION TABLES
SN54ALS653, SN54AS651,
SN74ALS651A, SN74ALS653, SN74AS651
INPUTS
DATA I/O
OEAB OEBA CLKAB CLKBA SAB SBA A1–A8 B1–B8
OPERATION OR FUNCTION
L H H or L H or L X X Input Input Isolation L H ↑↑X X Input Input Store A and B data X H H or L X X Input Unspecified
Store A, hold B
H H ↑↑X
X Input Output Store A in both registers
L X H or L X X Unspecified
Input Hold A, store B
L L ↑↑XX
Output Input Store B in both registers L L X X X L Output Input Real-time B data to A bus L L X H or L X H Output Input Stored B data to A bus H H X X L X Input Output Real-time A data to B bus H H H or L X H X Input Output Stored A data to B bus
H L H or L H or L H H Output Output
Stored A data to B bus and
stored B
data to A bus
The data output functions may be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data input functions are always enabled; i.e., data at the bus terminals is stored on every low-to-high transition on the clock inputs.
Select control = L; clocks can occur simultaneously. Select control = H; clocks must be staggered to load both registers.
SN54ALS652, SN54AS652,
SN74ALS652A, SN74ALS654, SN74AS652
INPUTS
DATA I/O
OEAB OEBA CLKAB CLKBA SAB SBA A1–A8 B1–B8
OPERATION OR FUNCTION
L H H or L H or L X X Input Input Isolation L H ↑↑X X Input Input Store A and B data X H H or L X X Input Unspecified
Store A, hold B
H H ↑↑X
X Input Output Store A in both registers
L X H or L X X Unspecified
Input Hold A, store B
L L ↑↑XX
Output Input Store B in both registers L L X X X L Output Input Real-time B data to A bus L L X H or L X H Output Input Stored B data to A bus H H X X L X Input Output Real-time A data to B bus H H H or L X H X Input Output Stored A data to B bus
H L H or L H or L H H Output Output
Stored A data to B bus and
stored B data to A bus
The data output functions may be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data input functions are always enabled; i.e., data at the bus terminals is stored on every low-to-high transition on the clock inputs.
Select control = L; clocks can occur simultaneously. Select control = H; clocks must be staggered to load both registers.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic symbols
OEBA
EN1 [BA]
21
G5
22
SBA
A1
4
B1
20
4D
EN2 [AB]
3
OEAB
23
CLKBA
1
CLKAB
G7
2
SAB
5
7
7
5
1
1
6D 1
1
1
2
C6
C4
A2
5
B2
19
A3
6
B3
18
A4
7
B4
17
A5
8
B5
16
A6
9
B6
15
A7
10
B7
14
A8
11
B8
13
OEBA
EN1 [BA]
21
G5
22
SBA
A1
4
B1
20
4D
EN2 [AB]
3
OEAB
23
CLKBA
1
CLKAB
G7
2
SAB
5
7
7
5
1
1
6D 1
1
1
2
C6
C4
A2
5
B2
19
A3
6
B3
18
A4
7
B4
17
A5
8
B5
16
A6
9
B6
15
A7
10
B7
14
A8
11
B8
13
OEBA
EN1 [BA]
21
G5
22
SBA
A1
4
B1
20
4D
EN2 [AB]
3
OEAB
23
CLKBA
1
CLKAB
G7
2
SAB
5
7
7
5
1
1
6D 1
1
1
2
C6
C4
A2
5
B2
19
A3
6
B3
18
A4
7
B4
17
A5
8
B5
16
A6
9
B6
15
A7
10
B7
14
A8
11
B8
13
OEBA
EN1 [BA]
21
G5
22
SBA
A1
4
B1
20
4D
EN2 [AB]
3
OEAB
23
CLKBA
1
CLKAB
G7
2
SAB
5
7
7
5
1
1
6D 1
1
1
2
C6
C4
A2
5
B2
19
A3
6
B3
18
A4
7
B4
17
A5
8
B5
16
A6
9
B6
15
A7
10
B7
14
A8
11
B8
13
SN54ALS653, SN74ALS653 SN74ALS654
SN54AS651,
SN74ALS651A, SN74AS651
SN54ALS652, SN54AS652,
SN74ALS652A, SN74AS652
These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the DW, JT, and NT packages.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic diagrams (positive logic)
OEBA
A1
B1
1D
C1
1D
C1
One of Eight Channels
20
4
2
1
22
23
21
3
SAB
CLKAB
SBA
CLKBA
OEAB
To Seven Other Channels
SN54ALS653, SN54AS651,
SN74ALS651A, SN74ALS653, SN74AS651
OEBA
A1
B1
1D
C1
1D
C1
One of Eight Channels
20
4
2
1
22
23
21
3
SAB
CLKAB
SBA
CLKBA
OEAB
To Seven Other Channels
SN54ALS652, SN54AS652,
SN74ALS652A, SN74ALS654, SN74AS652
Pin numbers shown are for the DW, JT, and NT packages.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
: Control inputs 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I/O ports 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS652 –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS651A, SN74ALS652A 0°C to 70°C. . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74ALS651A
MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
OH
High-level output current –15 mA
24
IOLL
ow-level output curren
t
48
m
A
f
clock
Clock frequency 0 40 MHz
CLKBA or CLKAB high 12.5
twPulse duration
CLKBA or CLKAB low 12.5
ns
t
su
Setup time before CLKAB or CLKBA A or B 10 ns
t
h
Hold time after CLKAB or CLKBA A or B 0 ns
T
A
Operating free-air temperature 0 70 °C
Applies only to the SN74ALS651A-1 and only if VCC is maintained between 4.75 V and 5.25 V
recommended operating conditions
SN54ALS652 SN74ALS652A
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.7 0.8 V
I
OH
High-level output current –12 –15 mA
12 24
IOLL
ow-level output curren
t
48
m
A
f
clock
Clock frequency 0 35 0 40 MHz
CLKBA or CLKAB high 14.5 12.5
twPulse duration
CLKBA or CLKAB low 14.5 12.5
ns
t
su
Setup time before CLKAB or CLKBA A or B 15 10 ns
t
h
Hold time after CLKAB or CLKBA A or B 5 0 ns
T
A
Operating free-air temperature –55 125 0 70 °C
Applies only to the SN74ALS652A-1 and only if VCC is maintained between 4.75 V and 5.25 V
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN74ALS651A
PARAMETER
TEST CONDITIONS
MIN TYP†MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.2 V VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC–2
V
OH
IOH = –3 mA 2.4 3.2
V
V
CC
= 4.5
V
IOH = –15 mA 2 IOL = 12 mA 0.25 0.4
V
OL
V
CC
= 4.5
V
IOL = 24 mA 0.35 0.5
V
VCC = 4.75 V , IOL = 48 mA (-1 versions) 0.35 0.5
Control inputs VCC = 5.5 V, VI = 7 V 0.1
I
I
A or B ports VCC = 5.5 V, VI = 5.5 V 0.1
mA
Control inputs
20
I
IH
A or B ports
V
CC
= 5.5 V,
V
I
= 2.7
V
20
µ
A
Control inputs
–0.2
I
IL
A or B ports
V
CC
=
5.5 V
,
V
I
=
0.4 V
–0.2
m
A
I
O
§
VCC = 5.5 V, VO = 2.25 V –30 –112 mA
Outputs high 42 68
I
CC
VCC = 5.5 V
Outputs low 52 82
mA
Outputs disabled 52 82
All typical values are at VCC = 5 V, TA = 25°C.
For I/O ports, the parameters IIH and IIL include the off-state output current.
§
The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
9
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN54ALS652 SN74ALS652A
PARAMETER
TEST CONDITIONS
MIN TYP†MAX MIN TYP†MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.2 –1.2 V VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC–2 VCC–2
IOH = –3 mA 2.4 3.2 2.4 3.2
V
OH
VCC = 4.5 V
IOH = –12 mA 2
V
IOH = –15 mA 2 IOL = 12 mA 0.25 0.4 0.25 0.4
V
OL
V
CC
= 4.5
V
IOL = 24 mA 0.35 0.5
V
VCC = 4.75 V , IOL = 48 mA (-1 versions) 0.35 0.5
Control inputs VCC = 5.5 V, VI = 7 V 0.1 0.1
I
I
A or B ports VCC = 5.5 V, VI = 5.5 V 0.1 0.1
mA
Control inputs
20 20
I
IH
A or B ports
V
CC
=
5.5 V
,
V
I
=
2.7 V
20 20
µ
A
Control inputs
–0.2 –0.2
I
IL
A or B ports
V
CC
= 5.5 V,
V
I
= 0.4
V
–0.2 –0.2
m
A
I
O
§
VCC = 5.5 V,
VO = 2.25 V –20 –112 –30 –112 mA Outputs high 47 76 47 76
I
CC
VCC = 5.5 V
Outputs low 55 88 55 88
mA
Outputs disabled 55 88 55 88
All typical values are at VCC = 5 V, TA = 25°C.
For I/O ports, the parameters IIH and IIL include the off-state output current.
§
The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
10
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 Ω, R2 = 500 Ω, TA = MIN to MAX
UNIT
SN74ALS651A
MIN MAX
f
max
40 MHz
t
PLH
8 32
t
PHL
CLKBA or CLKAB
A or B
5 17
ns
t
PLH
2 18
t
PHL
A or B
B or A
2 10
ns
t
PLH SBA or SAB
8 38
t
PHL
(with A or B high)
A or B
6 21
ns
t
PLH SBA or SAB
8 25
t
PHL
(with A or B low)
A or B
7 21
ns
t
PZH
3 20
t
PZL
OEBA
A
5 18
ns
t
PHZ
2 9
t
PLZ
OEBA
A
3 12
ns
t
PZH
3 22
t
PZL
OEAB
B
6 21
ns
t
PHZ
2 12
t
PLZ
OEAB
B
2 14
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
These parameters are measured with the internal output state of the storage register opposite that of the bus input.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
11
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 Ω, R2 = 500 Ω, TA = MIN to MAX
UNIT
SN54ALS652 SN74ALS652A
MIN MAX MIN MAX
f
max
35 40 MHz
t
PLH
10 35 8 30
t
PHL
CLKBA or CLKAB
A or B
5 20 5 17
ns
t
PLH
5 20 4 18
t
PHL
A or B
B or A
3 15 3 12
ns
t
PLH
SBA or SAB
15 40 8 35
t
PHL
SBA or SAB
(with A or B high)
A or B
6 23 6 20
ns
t
PLH
SBA or SAB
8 30 8 25
t
PHL
SBA or SAB
(with A or B low)
A or B
5 24 5 20
ns
t
PZH
3 20 3 17
t
PZL
OEBA
A
5 22 5 18
ns
t
PHZ
1 12 1 10
t
PLZ
OEBA
A
2 20 2 16
ns
t
PZH
8 25 3 22
t
PZL
OEAB
B
6 21 5 18
ns
t
PHZ
1 12 1 10
t
PLZ
OEAB
B
2 21 2 16
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
These parameters are measured with the internal output state of the storage register opposite that of the bus input.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
12
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
: All inputs and A I/O ports 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B I/O ports 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS653 –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS653, SN74ALS654 0°C to 70°C. . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS653 SN74ALS653
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.7 0.8 V
V
OH
High-level output voltage A ports 5.5 5.5 V
I
OH
High-level output current B ports –12 –15 mA
I
OL
Low-level output current 12 24 mA
f
clock
Clock frequency 0 25 0 35 MHz
CLKBA or CLKAB high 20 14.5
twPulse duration
CLKBA or CLKAB low 20 14.5
ns
t
su
Setup time before CLKAB or CLKBA A or B 15 10 ns
t
h
Hold time after CLKAB or CLKBA A or B 5 0 ns
T
A
Operating free-air temperature –55 125 0 70 °C
recommended operating conditions
SN74ALS654
MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
V
OH
High-level output voltage A ports 5.5 V
I
OH
High-level output current B ports –15 mA
I
OL
Low-level output current 24 mA
f
clock
Clock frequency 0 35 MHz
CLKBA or CLKAB high 14.5
twPulse duration
CLKBA or CLKAB low 14.5
ns
t
su
Setup time before CLKAB or CLKBA A or B 10 ns
t
h
Hold time after CLKAB or CLKBA A or B 0 ns
T
A
Operating free-air temperature 0 70 °C
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
13
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN54ALS653 SN74ALS653
PARAMETER
TEST CONDITIONS
MIN TYP†MAX MIN TYP†MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.2 –1.2 V VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC–2 VCC–2
p
IOH = –3 mA 2.4 3.2 2.4 3.2
VOHB ports
VCC = 4.5 V
IOH = –12 mA 2
V
IOH = –15 mA 2 IOL = 12 mA 0.25 0.4 0.25 0.4
VOLV
CC
= 4.5
V
IOL = 24 mA 0.35 0.5
V
Control inputs VCC = 5.5 V, VI = 7 V 0.1 0.1
I
I
A or B ports VCC = 5.5 V, VI = 5.5 V 0.1 0.1
mA
Control inputs
20 20
I
IH
A or B ports
V
CC
= 5.5 V,
V
I
= 2.7
V
20 20
µ
A
Control inputs
–0.2 –0.2
I
IL
A or B ports
V
CC
=
5.5 V
,
V
I
=
0.4 V
–0.2 –0.2
m
A
I
OH
A ports VCC = 4.5 V, VOH = 5.5 V 0.1 0.1 mA
I
O
§
B ports VCC = 5.5 V, VO = 2.25 V –20 –112 –30 –112 mA
Outputs high 47 76 47 76
I
CC
VCC = 5.5 V
Outputs low 55 88 55 88
mA
Outputs disabled 55 88 55 88
All typical values are at VCC = 5 V, TA = 25°C.
For I/O ports, the parameters IIH and IIL include the off-state output current.
§
The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
14
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN74ALS654
PARAMETER
TEST CONDITIONS
MIN TYP†MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.2 V VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC–2
V
OH
B ports
IOH = –3 mA 2.4 3.2
V
V
CC
= 4.5
V
IOH = –15 mA 2 IOL = 12 mA 0.25 0.4
V
OL
V
CC
= 4.5
V
IOL = 24 mA 0.35 0.5
V
Control inputs VCC = 5.5 V, VI = 7 V 0.1
I
I
A or B ports VCC = 5.5 V, VI = 5.5 V 0.1
mA
Control inputs
20
I
IH
A or B ports
V
CC
= 5.5 V,
V
I
= 2.7
V
20
µ
A
Control inputs
–0.2
I
IL
A or B ports
V
CC
= 5.5 V,
V
I
= 0.4
V
–0.2
mA
I
OH
A ports VCC = 4.5 V, VOH = 5.5 V 0.1 mA
I
O
§
B ports VCC = 5.5 V, VO = 2.25 V –30 –112 mA
Outputs high 47 76
I
CC
VCC = 5.5 V
Outputs low 55 88
mA
Outputs disabled 55 88
All typical values are at VCC = 5 V, TA = 25°C.
For I/O ports, the parameters IIH and IIL include the off-state output current.
§
The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
15
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 680 (A outputs), R1 = R2 = 500 (B outputs), TA = MIN to MAX
UNIT
SN54ALS653 SN74ALS653
MIN MAX MIN MAX
f
max
25 35 MHz
t
PLH
16 71 16 64
t
PHL
CLKBA
A
6 24 6 22
ns
t
PLH
10 35 10 30
t
PHL
CLKAB
B
5 20 5 17
ns
t
PLH
5 20 5 18
t
PHL
A
B
1.5 18 2 15
ns
t
PLH
8 63 12 56
t
PHL
B
A
2 18 2 15
ns
t
PLH
SBA
12 68 19 62
t
PHL
(with B high)
A
5 27 5 25
ns
t
PLH
SBA
12 68 19 62
t
PHL
(with B low)
A
5 27 5 25
ns
t
PLH
SAB
8 30 15 35
t
PHL
(with A high)
B
6 25 6 22
ns
t
PLH
SAB
12 40 8 25
t
PHL
(with A low)
B
6 25 6 22
ns
t
PLH
6 35 6 30
t
PHL
OEBA
A
6 27 6 24
ns
t
PZH
7 25 8 22
t
PZL
OEAB
B
6 25 6 22
ns
t
PHZ
1 16 1 14
t
PLZ
OEAB
B
2 21 2 16
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
These parameters are measured with the internal output state of the storage register opposite that of the bus input.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
16
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 680 (A outputs), R1 = R2 = 500 (B outputs), TA = MIN to MAX
UNIT
SN74ALS654
MIN MAX
f
max
35 MHz
t
PLH
16 64
t
PHL
CLKBA
A
6 22
ns
t
PLH
10 30
t
PHL
CLKAB
B
5 17
ns
t
PLH
5 18
t
PHL
A
B
2 15
ns
t
PLH
12 56
t
PHL
B
A
2 21
ns
t
PLH
SBA
19 62
t
PHL
(with B low)
A
5 25
ns
t
PLH
SBA
19 62
t
PHL
(with B high)
A
5 25
ns
t
PLH
SAB
15 35
t
PHL
(with A low)
B
6 22
ns
t
PLH
SAB
8 25
t
PHL
(with A high)
B
6 22
ns
t
PLH
6 30
t
PHL
OEBA
A
6 24
ns
t
PZH
6 22
t
PZL
OEAB
B
6 22
ns
t
PHZ
1 14
t
PLZ
OEAB
B
2 16
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
These parameters are measured with the internal output state of the storage register opposite that of the bus input.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
17
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
: Control inputs 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I/O ports 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54AS651, SN54AS652 –55°C to 125°C. . . . . . . . . . . . . . . . . . .
SN74AS651, SN74AS652 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS651 SN54AS652
SN74AS651 SN74AS652
UNIT
MIN NOM MAX MIN NOM MAX
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
OH
High-level output current –12 –15 mA
I
OL
Low-level output current 32 48 mA
f
clock
* Clock frequency 0 75 0 90 MHz
*
CLKBA or CLKAB high 6 5
tw*
Pulse duration
CLKBA or CLKAB low 7 6
ns
tsu* Setup time before CLKAB or CLKBA A or B 7 6 ns th* Hold time after CLKAB or CLKBA A or B 0 0 ns T
A
Operating free-air temperature –55 125 0 70 °C
* On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
18
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS
SN54AS651 SN54AS652
SN74AS651 SN74AS652
UNIT
MIN TYP†MAX MIN TYP†MAX
V
IK
VCC = 4.5 V, II = –18 mA –1.2 –1.2 V VCC = 4.5 V to 5.5 V, IOH = –2 mA VCC–2 VCC–2
IOH = –3 mA 2.4 3.2 2.4 3.2
V
OH
VCC = 4.5 V
IOH = –12 mA 2
V
IOH = –15 mA 2 IOL = 32 mA 0.25 0.5
VOLV
CC
=
4.5 V
IOL = 48 mA 0.35 0.5
V
Control inputs VCC = 5.5 V, VI = 7 V 0.1 0.1
I
I
A or B ports VCC = 5.5 V, VI = 5.5 V 0.1 0.1
mA
Control inputs
20 20
I
IH
A or B ports
V
CC
= 5.5 V,
V
I
= 2.7
V
70 70
µ
A
Control input
–0.5 –0.5
I
IL
A or B ports
V
CC
= 5.5 V,
V
I
= 0.4
V
–0.75 –0.75
m
A
I
O
§
VCC = 5.5 V, VO = 2.25 V –30 –112 –30 –112 mA
Outputs high 110 185 110 185
AS651 VCC = 5.5 V
Outputs low 120 195 120 195 Outputs disabled 130 195 130 195
I
CC
Outputs high 120 195 120 195
mA
AS652 VCC = 5.5 V
Outputs low 130 21 1 130 211 Outputs disabled 130 211 130 211
All typical values are at VCC = 5 V, TA = 25 °C.
For I/O ports, the parameters IIH and IIL include the off-state output current.
§
The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
19
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 Ω, R2 = 500 Ω, TA = MIN to MAX
UNIT
SN54AS651 SN74AS651
MIN MAX MIN MAX
f
max
* 75 90 MHz
t
PLH
2 11 2 8.5
t
PHL
CLKBA or CLKAB
A or B
2 10 2 9
ns
t
PLH
2 12 2 8
t
PHL
A or B
B or A
1 8 1 7
ns
t
PLH
2 15 2 11
t
PHL
SBA
or
SAB
A or B
2 11 2 9
ns
t
PZH
2 11 2 10
t
PZL
OEBA
A
3 18 3 16
ns
t
PHZ
2 10 2 9
t
PLZ
OEBA
A
2 10 2 9
ns
t
PZH
3 12 3 11
t
PZL
OEAB
B
3 20 3 16
ns
t
PHZ
2 11 2 10
t
PLZ
OEAB
B
2 12 2 11
ns
* On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested. †
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
These parameters are measured with the internal output state of the storage register opposite that of the bus input.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
20
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V TO 5.5 V,
CL = 50 PF, R1 = 500 Ω, R2 = 500 Ω,
TA = MIN TO MAX
UNIT
SN54AS652 SN74AS652
MIN MAX TYP MAX
f
max
* 75 90 MHz
t
PLH
2 11 2 8.5
t
PHL
CLKBA or CLKAB
A or B
2 10 2 9
ns
t
PLH
2 12 2 9
t
PHL
A or B
B or A
1 8 1 7
ns
t
PLH
2 15 2 11
t
PHL
SBA
or
SAB
A or B
2 11 2 9
ns
t
PZH
2 11 2 10
t
PZL
OEBA
A
3 18 3 16
ns
t
PHZ
2 10 2 9
t
PLZ
OEBA
A
2 10 2 9
ns
t
PZH
3 12 3 11
t
PZL
OEAB
B
3 20 3 16
ns
t
PHZ
2 11 2 10
t
PLZ
OEAB
B
2 12 2 11
ns
* On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested. †
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
These parameters are measured with the internal output state of the storage register opposite that of the bus input.
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
21
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
t
PHZ
t
PLZ
t
PHL
t
PLH
0.3 V
t
PZL
t
PZH
TEST S1
Open Open Open
t
PHL
t
PZH
t
PZL
Closed
Open
Closed
t
PHZ
t
PLZ
t
PLH
t
PHL
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
From Output
Under Test
Test Point
R1 = 500
S1
CL = 50 pF
(see Note A)
7 V
Open
1.3 V
1.3 V
1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
t
h
t
su
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
Timing
Input
Data
Input
1.3 V
1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
High-Level
Pulse
Low-Level
Pulse
t
w
VOLTAGE WAVEFORMS
PULSE DURATION
Input
Out-of-Phase
Output
1.3 V
1.3 V
1.3 V1.3 V
1.3 V 1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
V
OL
V
OH
V
OH
V
OL
Output
Control
Waveform 1
S1 Closed
(see Note B)
Waveform 2
S1 Open
(see Note B)
0 V
V
OH
V
OL
3.5 V
In-Phase
Output
0.3 V
t
PLH
1.3 V
1.3 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
SWITCH POSITION TABLE
R2 = 500
V
CC
R
L
Test Point
From Output
Under Test
CL = 50 pF
(see Note A)
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Zo = 50 , tr 2 ns, tf≤ 2 ns. D. The outputs are measured one at a time with one transition per measurement.
Figure 2. Load Circuits and Voltage Waveforms
IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICA TIONS IS UNDERST OOD TO BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated