Teledyne T3AFG5, T3AFG10 Quick Start Manual

Version 1.1
September, 2018
T3AFG5 / T3AFG10
Function / Arbitrary Waveform Generators
Quick Start Guide
Contents
General Safety Summary................................................................................. 1
Adjustment Handle ........................................................................................... 4
Front Panel ...................................................................................................... 5
Back Panel ........................................................................................................ 9
User Interface.................................................................................................. 10
Using In-line Help System ................................................................................12
© 2018 Teledyne LeCroy, Inc. All rights reserved.
Teledyne Test Tools is a brand and trademark of Teledyne LeCroy, Inc. Other product or brand names are trademarks or requested trademarks of their respective holders. Specifications, prices, availability and delivery subject to change without notice.
General Safety Summary
Read the following precautions carefully to avoid any injuries, Use the instrument only as specified.
Use only the power cord supplied for the instrument.
Ground the instrument. The instrument is grounded through the ground conductor of the power cord. To avoid electric shock, always connect to grounded outlets. Make sure the instrument is grounded correctly before connecting its input or output terminals.
Do not connect external signals. The BNC connector is used to output the generated waveforms only. No external signals should be connected to the BNC, or the instrument may be damaged.
Observe all terminal ratings and signs on the instrument to avoid fire or electric shock. Before connecting to the instrument, read the manual to understand the input/output ratings.
Do not operate with suspected failures. If you suspect that the instrument is damaged, contact the Teledyne LeCroy service department immediately.
or damage to the instrument or products connected to it.
personal
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep the surface of the instrument clean and dry.
Avoid touching exposed circuits or wires. Do not touch
exposed contacts or components when the power is on.
Do not operate without covers. Do not operate the instrument with covers or panels removed.
Use only the fuse specified for the instrument.
Use proper over voltage protection.
Observe ventilation requirements. Ensure good ventilation.
Check the vent and fan regularly to prevent overheating.
Quick Start 1
2 Quick Start
Safety Terms and Symbols
The following terms may appear on the instrument:
DANGER:
Direct injury or hazard may occur.
WARNING:
Potential injury or hazard may occur.
CAUTION:
Potential damage to instrument/property may occur.
The following symbols may appear on the instrument:
CAUTION
Risk of
injury or
damage.
Refer to
manual.
WARNING
Risk of electric
shock or
burn
Earth
Ground
Terminal
Protective
Conductor
Terminal
Frame or
Chassis
Terminal
ON/
Standby
Power
Alternating
Current
Operating Environment
Temperature: 0 °C to 40 °C
Relative Humidity: 90% RH at ≤ 35 °C, 60% RH at 35 - 40 °C
Altitude: ≤ 3000 m
Use indoors only.
Pollution Degree 2. Use in an operating environment where
normally only dry, non-conductive pollution occurs. Temporary conductivity caused by condensation should be expected.
Quick Start 3
AC Power
Input Voltage & Frequency: 100-120 V at 400 Hz or
100-240 V at 50/60 Hz
Automatic AC selection.
Power Consumption: 50 W maximum
Mains Supply Connector: CAT II per IEC/EN 61010-1:2010,
instrument intended to be supplied from the building wiring at utilization points (socket outlets and similar).
Fuse Type
1.25 A, 250 V