GE
Sensing
Telaire
Accessories
Telaire accessories are part of the
Telaire product line. Telaire has
joined other GE high-technology
sensing businesses under a new
name–GE Industrial, Sensing.
g
Calibration Kits,
Enclosures, Software,
Cables
Calibration Kits
The Calibration Kit Model 2075 includes all of the
necessary components for calibrating the Telaire®7001
and Ventotstat 8000 and 8100 series models. The kit is
housed in a carrying case with only one replacement
part (calibration gas) required. Each 16 liter gas bottle
can perform up to 20 calibrations. Calibration Kit Model
2076 calibrates the Vaporstat 9002.
Accessory Enclosures
GE Sensing offers three enclosures to expand the
Ventostat and Vaporstat installation options: Model 1508
Aspiration Box, Model 1505 Splash Resistant Enclosure,
Model 1551 Outdoor Air Enclosure.
Software
Windows based VG Graphing Software allows you to
easily download your IAQ measurements and customize
graphs.
2080 CO
2
View Logging Software
CO2View is a Windows based program that interfaces
with the 8000 and 7000 series sensors. This easy to use
program displays and graphs real-time CO2levels at a
user adjustable interval.
UIP 2072
Make adjustments and modify your 8000 series CO
2
sensor parameters.
7001 Accessories
The Telaire 7001 hand held CO
2
and temperature monitor
is equipped with an output for recording data. The cable,
Model 2070, can be used with devices that accept a 0 to
4V signal
A relative humidity and datalogging kit with graphing
software, Model 2077, is available to long term
monitoring.
Part 62933 is an adapter for international operation.

GE
Sensing
Calibration Process
The calibration is simple and can be done in just a few
minutes. Each CO2model has a calibration process
similar to the following:
• Connect the tubing assembly to the sensor and
connect the regulator to the gas bottle.
• Initiate the calibration process by using the sensor
buttons and display.
• The process is automatically run by the sensor and will
signal upon completion.
• Last, disconnect the tubing and gas regulator.
2075 Components
The Calibration Kit Model 2075 includes:
• Instruction sheet
• One bottle of nitrogen gas
• Tubing assembly
• Gas regulator with guage
• Carrying case.
Calibrates the following models:
• Ventostat 8000 and 8100 Series
• Telaire 7000 Series
The illustration shows the complete set-up for
calibrating a sensor with display.
2076 Components
The Calibration Kit Model 2076 includes:
• Instruction sheet
• One bottle of pure nitrogen gas
• Tubing assembly
• Gas regulator with guage
• Carrying case.
• Flow Meter
Calibrates the following models:
• Vaporstat 9002
Calibration Kits
2075 and 2076

combustion fumes in parking garages, tunnels and
loading docks. This enclosure features a temperature
control circuit and internal heaters to maintain the sensor
within its normal operating temperature range, even if
temperatures outside the enclosure are as low as –20°F
(-29°C). Four diffusion ports allow for entry of CO2.
Response time of the sensor is slowed approximately
30 minutes to measure a 90% step change in
concentrations. Enclosure is designed to screw directly to
a wall. CO2sensor not included.
Power consumption
24V, 1.5 Amp (maximum) – including sensor
Enclosures are compatible with all Ventostat 8000 series
(except the 8003 and 8009) and Vaporstat 9002 models.
1508 Aspiration Box
The Model 1508 is designed for in-duct sampling of CO
2
concentrations at flow rates greater than 400 fpm. Clear
cover allows for observation of the sensor. Enclosure is
screwed to the duct with probe inserted into airstream.
Air sampling probe is 1 in (25.4 mm) diameter and 8 in
(203.2 mm) long. Enclosure (ABS plastic) has knockouts for
conduit connection. CO2Sensor not included.
1505 Splash Resistant Enclosure
The Model 1505 is designed to protect the sensor in
damp or wet environments which might occur in
agricultural, industrial or food processing environments.
This enclosure (ABS plastic) is designed to protect the
sensor from dripping or sprayed water. The transparent
cover allows for viewing of the sensor/display. Four
diffusion ports allow for entry of CO
2
. Knockouts are
provided for conduit connection. Response time of the
sensor is slowed to approximately 30 minutes to
measure a 90% step change in concentrations. Enclosure
is designed to screw directly to a wall. CO2sensor not
included.
1551 Outside Air Enclosure
The Model 1551 is a rugged weatherproof enclosure (ABS
plastic), designed to allow the 8000 series sensor to
operate in an outdoor environment and/or where
ambient temperatures are below freezing. The 1551 is
ideal for monitoring outside air or CO2as a surrogate for
Pin
Designations
1.
AC+
/
DC+
2.
AC-
/
GN
D
GE
Sensing
Enclosures
Specifications
Tubing on 1508 Only
PinD
1.NotU
2.NotU
3.R
4.R
esignations
5.R
elayNorm
6.4-20mA
sed
elayCom
7.Signal
sed
elay
8.0-10V
N
orm
Pin
Open
Ground
mon
Output
1.AC+/D
Output
2.
Closed
Designation
AC-/GN
Po
18
w
18-42
-36
100
er
70
C+
R
VA
m
D
m
equ
VDC
A
C
A
s
Peak,
avg
rms
ire
m
@
or
e
nt
2
s
4VDC
Mounting Bracket
(Pre-Installed on 1551)
Any of the Ventostat
8000 Series Sensors
Cover
Spouts on
1505 and 1551 Only
7 in
(177.8 mm)
3.5 in (88.9 mm)
10.5 in (266.7mm)
Extension Tube
on 1508 Only
1.13 in (28.7 mm)
1.13 in (28.7 mm) and 1.7in (43.18 mm)
0.88 in (22.35 mm)
7 in (177.8 mm)
6.5 in (165.1 mm)
Cover Removed
3.75 in (95.25 mm)
4.25 in (107.95 mm)