TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules
Specification and Performance Verification
Register now!
Click the following link to protect your product.
www.tek.com/register
077-1608-00
Table of Contents
Table of Contents
Important safety information..........................................................................................................................................................4
General safety summary........................................................................................................................................................4
To avoid fire or personal injury........................................................................................................................................4
Service safety summary.........................................................................................................................................................5
Terms in the manual...............................................................................................................................................................6
Terms on the product............................................................................................................................................................. 6
Symbols on the product......................................................................................................................................................... 6
Related documents ............................................................................................................................................................... 7
Signal acquisition system................................................................................................................................................8
Controls and indicators................................................................................................................................................... 9
Input and Output communication ports...........................................................................................................................9
TSO8C17 and TSO8C18 Specifications.............................................................................................................................. 11
Frequency response............................................................................................................................................................ 14
Power monitor accuracy...................................................................................................................................................... 16
Output zero (dark level)....................................................................................................................................................... 19
TSO820 sampling oscilloscope test records........................................................................................................................20
Clock prescale input trigger sensitivity test record........................................................................................................21
Frequency Response Test Record 12.6 GHz............................................................................................................... 23
Frequency Response Test Record 13.28125 GHz....................................................................................................... 24
Frequency Response Test Record 19.335 GHz........................................................................................................... 25
Frequency Response Test Record 21 GHz.................................................................................................................. 26
Frequency Response Test Record 22.5 GHz............................................................................................................... 27
Power monitor accuracy AOP Error test record............................................................................................................28
Power monitor accuracy AOP mean test record...........................................................................................................29
Vertical equivalent optical noise test record..................................................................................................................30
Output zero (dark level) test record.............................................................................................................................. 31
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification iii
Important safety information
This manual contains information and warnings that must be followed by the user for safe operation and to keep the product
in a safe condition.
To safely perform service on this product, see the Service safety summary that follows the General safety summary.
General safety summary
Use the product only as specified. Review the following safety precautions to avoid injury and prevent damage to this
product or any products connected to it. Carefully read all instructions. Retain these instructions for future reference.
This product shall be used in accordance with local and national codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition
to the safety precautions specified in this manual.
The product is designed to be used by trained personnel only.
Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or
adjustment.
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Important safety information
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other
component manuals for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the
system.
To avoid fire or personal injury
Use proper power cord.Use only the power cord specified for this product and certified for the country of use.
Ground the product.This product is grounded through the grounding conductor of the power cord. To
Power disconnect.The power cord disconnects the product from the power source. See instructions for
Observe all terminal ratingsTo avoid fire or shock hazard, observe all rating and markings on the product.
Do not use the provided power cord for other products.
avoid electric shock, the grounding conductor must be connected to earth ground.
Before making connections to the input or output terminals of the product, ensure
that the product is properly grounded. Do not disable the power cord grounding
connection.
the location. Do not position the equipment so that it is difficult to operate the power
cord; it must remain accessible to the user at all times to allow for quick
disconnection if needed.
Consult the product manual for further ratings information before making connections
to the product.
Do not apply a potential to any terminal, including the common terminal, that
exceeds the maximum rating of that terminal.
Do not float the common terminal above the rated voltage for that terminal.
The measuring terminals on this product are not rated for connection to mains or
Category II, III, or IV circuits.
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification 4
Important safety information
Do not operate without covers.Do not operate this product with covers or panels removed, or with the case open.
Hazardous voltage exposure is possible.
Avoid exposed circuitry.Do not touch exposed connections and components when power is present.
Do not operate with suspected
failures.
Do not operate in wet/damp
conditions.
Do not operate in an explosive
atmosphere.
Keep product surfaces clean and
dry.
Provide proper ventilation.Refer to the installation instructions in the manual for details on installing the product
Provide a safe working
environment.
If you suspect that there is damage to this product, have it inspected by qualified
service personnel.
Disable the product if it is damaged. Do not use the product if it is damaged or
operates incorrectly. If in doubt about safety of the product, turn it off and disconnect
the power cord. Clearly mark the product to prevent its further operation.
Before use, inspect voltage probes, test leads, and accessories for mechanical
damage and replace when damaged. Do not use probes or test leads if they are
damaged, if there is exposed metal, or if a wear indicator shows.
Examine the exterior of the product before you use it. Look for cracks or missing
pieces.
Use only specified replacement parts.
Be aware that condensation may occur if a unit is moved from a cold to a warm
environment.
Remove the input signals before you clean the product.
so it has proper ventilation.
Slots and openings are provided for ventilation and should never be covered or
otherwise obstructed. Do not push objects into any of the openings.
Always place the product in a location convenient for viewing the display and
indicators.
Avoid improper or prolonged use of keyboards, pointers, and button pads. Improper
or prolonged keyboard or pointer use may result in serious injury.
Be sure your work area meets applicable ergonomic standards. Consult with an
ergonomics professional to avoid stress injuries.
Use care when lifting and carrying the product. This product is provided with a
handle or handles for lifting and carrying.
Use only the Tektronix rackmount hardware specified for this product.
Use only the Tektronix rackmount hardware specified for this product.
Service safety summary
The Service safety summary section contains additional information required to safely perform service on the product. Only
qualified personnel should perform service procedures. Read this Service safety summary and the General safety summary
before performing any service procedures.
To avoid electric shockDo not touch exposed connections.
Do not service aloneDo not perform internal service or adjustments of this product unless another person
capable of rendering first aid and resuscitation is present.
Disconnect powerTo avoid electric shock, switch off the product power and disconnect the power cord
from the mains power before removing any covers or panels, or opening the case for
servicing.
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification 5
Important safety information
Use care when servicing with
power on
Verify safety after repairAlways recheck ground continuity and mains dielectric strength after performing a
Terms in the manual
These terms may appear in this manual:
Dangerous voltages or currents may exist in this product. Disconnect power, remove
battery (if applicable), and disconnect test leads before removing protective panels,
soldering, or replacing components.
repair.
WARNING
Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION
Caution statements identify conditions or practices that could result in damage to this product or other property.
Terms on the product
These terms may appear on the product:
•DANGER indicates an injury hazard immediately accessible as you read the marking.
•WARNING indicates an injury hazard not immediately accessible as you read the marking.
•CAUTION indicates a hazard to property including the product.
Symbols on the product
The following symbols(s) may appear on the product.
When this symbol is marked on the product, be sure to
consult the manual to find out the nature of the potential
hazards and any actions which have to be taken to avoid
them. (This symbol may also be used to refer the user to
ratings in the manual.)
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification 6
Preface
This manual contains specifications, test record, and performance verification procedures for the following instruments:
•TSO820 sampling oscilloscope (mainframe)
•TSO8C17 one channel optical module
•TSO8C18 two channel optical module
Related documents
In addition to this Specifications and Performance Verification Technical Reference, the following documents are available
for download. For the most recent versions these documents, visit the Tektronix Web site at www.tek.com/manuals. You can
find manuals by searching on the product name and selecting the Manuals filter.
To learn aboutUse this document
How to install and turn on the instrument software and
hardware; read safety and compliance information.
How to operate the instrument, take measurements,
navigate the UI.
How to remotely control the instrument using programmatic
commands. Syntax provided.
Mainframe and module specifications. Includes procedures
to verify that the mainframe and modules meet warranted
specifications.
Installing up to two mainframes, or a mainframe and a
TCR801 clock recovery unit into a standard instrument rack
using the rackmount kit.
How to declassify, sanitize, and clear memory devices in the
instrument.
Preface
TSO8 Series Installation and Safety Instructions. Printed
and shipped with the instrument. Also available online as a
downloadable PDF. This document contains content in
English, Japanese, and Simplified Chinese.
TSO8 Series Help (a PDF of this Help is available as a
downloadable PDF)
TSO8 Series Programming Manual
TSO8 Series Specifications and Performance Verification
Technical Reference (this document)
TSO8 Series Rackmount Instructions
TSO8 Series Declassification and Security Instructions
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification 7
Specifications
TSO820 mainframe
Vertical system
Rise time / bandwidthDetermined by the sampling modules used
Vertical resolution (nominal)15.6 bits over the sampling modules’ dynamic range
Signal acquisition system
Number of input channels4 user channels acquisition maximum
Number of slots2 slots, 2 channels per slot, for 4 channels total
Vertical resolution15.6 bits at Tek Probe-Sampling interface
Timebase system
Main time base / horizontal scale 1 ps / div to 1 ms / div in 1-2-5 sequence or 1 ps increments
Horizontal modesSupports Free Run Trigger and Clock Trigger mode
Clock trigger mode sampling rate 200 kHz – 300 kHz, dictated by sample resolution of Time Base setup
Horizontal position range
Specifications
•19 ns minimum to 50 ms maximum; depends upon the reference clock frequency
(refClkFreq) per the formula:
Horizontal position setting
resolution
Record length
Horizontal sample resolution10 fs minimum to 10 μs maximum
Time interval accuracy, Clock
triggered mode (typical)
Trigger system
Trigger sourcesSupports the following for trigger source:
Clock prescale input trigger operation
Clock prescale input
characteristics
Clock prescale input pattern
lengths supported
•Horizontal position reference can change within the record, so the maximum
horizontal position value depends upon the horizontal scale as well.
10 fs minimum
•Pattern Sync is Off: 1000 to 838,860,700
•Pattern Sync is On: 762 to 838,860,700
± (1 ps + 1.5 % of trigger clock period)
•Clock Prescale Input
•Free Run Trigger
50 Ω, AC coupled
127 to 223 -1 (8,388,607) inclusive
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification 8
Specifications
Clock prescale input absolute
maximum input
Clock prescale input usable
frequency range
Clock prescale input range200 mVp-p to 1000 mVp-p over the range 500 MHz - 32 GHz
TSO820 Sampling Oscilloscope, TSO8C17 and TSO8C18 modules Specification and Performance Verification 9
Physical characteristics
Weight (with blank module)
Clearance requirementsThe clearance requirement for adequate cooling is 2.0 in (50.8 mm) on both sides
Overall dimensionsTSO820 (with filler module, no functional modules) requirements that follow are
Environmental performance
Temperature
Specifications
•12.0 lbs (5.4 kg) Stand-alone instrument, without front cover.
•19.5 lbs (8.8 kg) Instrument with rackmount, without front cover.
and at the rear of the instrument. Cooling inlets on the bottom require that the
instrument rests on a flat surface with feet providing sufficient clearance.
nominal and unboxed:
Height132 mm (5.18 in.)
Width217 mm (8.56 in.)
Depth590 mm (23.22 in.)
•Operating: 5 °C to +45 °C, with 15 °C/hour maximum gradient, non-condensing,
derated 1.0 °C per 300 meters above 1,500 meters altitude.
•Non-operating: -20 °C to +60 °C, with 30 °C/hour maximum gradient
Altitude
Humidity
Waveform measurement
System measurement rateSupports up to 32 simultaneous measurement with optional display of per-
CursorsVertical bar, horizontal bar, vertical and horizontal bar, and waveform cursors