Tektronix TRCP0300, TRCP3000, TRCP0600 User Manual

TRCP0300, TRCP0600, and TRCP3000 Current Probes
User Manual
*P077121300*
077-1213-00
TRCP0300, TRCP0600, and TRCP3000 Current Probes
User Manual
Warning
The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
www.tek.com
077-1213-00
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tek.com to find contacts in your area.

Table of Contents

Important safety information .............................................................. iii
General safety summary ............................................................... iii
Service safety summary ................................................................ vi
Terms in the manual ...................................................................... vi
Terms on the product ................................................................... vii
Symbols on the product ............................................................... vii
Compliance Information ..................................................................... ix
Safety compliance ......................................................................... ix
Environmental compliance ........................................................... xi
Specifications
Tektronix Rogowski Current Probe
Handling instructions ..................................................................... 6
Safety and pre-use checks .............................................................. 7
The Rogowski coil .................................................................... 8
The integrator ........................................................................... 9
Power options ................................................................................. 9
External supply ......................................................................... 9
Standard alkaline batteries ........................................................ 9
Using your Rogowski Probe
Replacing the battery .................................................................... 11
Switching on ................................................................................. 11
Obtaining the best measurement .................................................. 12
Sensitivity to external currents and voltages .......................... 12
Output cables .......................................................................... 13
Cleaning and decontamination ..................................................... 13
Returning your probe for recalibration or repair .......................... 13
TRCP0300, TRCP0600, TRCP3000 User Manual i
Table of Contents
ii TRCP0300, TRCP0600, TRCP3000 User Manual

Important safety information

This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition.
To safely perform service on this product, see the Service safety summary that follows the General safety summary.

General safety summary

Use the product only as specified. Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Carefully read all instructions. Retain these instructions for future reference.
This product shall be used in accordance with local and national codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition to the safety precautions specified in this manual.
The product is designed to be used by trained personnel only.
Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment.
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
The intended use of this product is for the measurement of AC current.
TRCP0300, TRCP0600, TRCP3000 User Manual iii
Important safety information
To avoid fire or personal injury
Use proper power cord. Use only the power cord specified for this
product and certified for the country of use.
Use proper power cord. Use only the power cord specified for this
product and certified for the country of use. Do not use the provided power cord for other products.
Ground the product.
Power disconnect.
Use proper AC adapter. Use only the AC adapter specified for this
product.
Connect and disconnect properly.
Observe all terminal ratings.
Observe all terminal ratings. To avoid fire or shock hazard, observe all
rating and markings on the product. Consult the product manual for further ratings information before making connections to the product.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not operate without covers. Do not operate this product with covers or
panels removed, or with the case open. Hazardous voltage exposure is possible.
Avoid exposed circuitry. Do not touch exposed connections and
components when power is present.
Do not operate with suspected failures. If you suspect that there is damage
to this product, have it inspected by qualified service personnel.
Disable the product if it is damaged. Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of the product, turn it off and disconnect the power cord. Clearly mark the product to prevent its further operation.
Before use, inspect probes, test leads, and accessories for mechanical damage and replace when damaged. Do not use probes or test leads if they are damaged, if there is exposed metal, or if a wear indicator shows.
iv TRCP0300, TRCP0600, TRCP3000 User Manual
Important safety information
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specified replacement parts.
Replace batteries properly. Replace batteries only with the specified type
and rating.
Do not operate in wet/damp conditions. Be aware that condensation may
occur if a unit is moved from a cold to a warm environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry. Remove the input signals before
you clean the product.
Provide proper ventilation. Refer to the installation instructions in the
manual for details on installing the product so it has proper ventilation.
Slots and openings are provided for ventilation and should never be covered or otherwise obstructed. Do not push objects into any of the openings.
Provide a safe working environment. Always place the product in a
location convenient for viewing the display and indicators.
Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to avoid stress injuries.
Probes, coil, and test leads
Remove all coils and BNC cables that are not in use
Use only correct Measurement Category (CAT), voltage, temperature, altitude, and amperage rated coils and BNC cables for any measurement.
Beware of high voltages.
Connect and disconnect properly.
Connect and disconnect properly. De-energize the circuit under test
before connecting or disconnecting the current probe.
Inspect the coil and accessories.
TRCP0300, TRCP0600, TRCP3000 User Manual v
Loading...
+ 21 hidden pages