Tektronix TCPA300 Data Sheet

Features & Benefits
AC/DC Measurement Capabilities
DC – 100 MHz, Current Probe Amplifier (TCPA300) Uses:
– DC – 100 MHz, 30 A DC
(TCP312)
– DC – 50 MHz, 50 A DC
– DC – 15 MHz, 150 A DC
DC – 50 MHz, Current Probe Amplifier (TCPA400) Uses:
– DC – 2 MHz, 750*1A DC
(TCP404XL) (500 A DC Continuous)
Direct Scaling and Units*2– Oscilloscope On-screen Readout Reduces Measurement Errors by Eliminating Hand Calculations
AC/DC Input Coupling Low Insertion Impedance –
Reduces Device Under Test Loading
Small Mechanical Package – Less Desktop Space, Easier Storage and Handling
Split-core Construction – Allows Easy Circuit Connection
Status Indicators Provide Notification of Potential Error Conditions
Lower DC Drift and Noise Certified for U.S., Canada,
and Europe
*1Derated with Duty Cycle. *
2
Requires a TDS TEKPROBE Oscilloscope or a TekConnect Oscilloscope with TCA-BNC.
Applications
Development and Analysis for: Power Supplies, Semiconductor Devices, Power Inverters/Converters, Electronic Ballasts, Industrial/Consumer Electronics, Mobile Communications, Motor Drives, Transportation Systems
AC/DC Current Measurement Systems
TCPA300 •TCP312 • TCP305 •TCP303 •TCPA400 •TCP404XL
Increased Performance and Simplicity
The TCP300 and TCP400 series AC/DC Current Measurement family is a highly advanced current measurement system for today’s current measurement needs.The split-core probes incorporate both transformer and Hall effect technology to provide broad bandwidth measurement capabilities from DC up to 100 MHz at current levels as low as 1 milliamp to thousands of amps (when used with CT4 current transformer). When connected to Tektronix TDS Oscilloscopes with TEKPROBE Level II or TekConnect (w/TCA-BNC) interfaces, current measurements and calculations are simple and easy.
Additional measurement power is available with add-on software such as the TDSPWR2 power measurements package.With all this measurement power current measurements have never been easier.
Meets Today’s AC/DC Current Measurement Applications
The TCPA300 amplifier, when used with TCP312,TCP305,or TCP303 probes,provide a wide range of current measurement capability and spans the gap between low level milliamp measurements to very high current levels. These three probes provide current measure­ment capabilities of 30A, 50A, and 150A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500A DC continuous and 750A DC continuous, derated with duty cycle.
Higher frequency performance is available with the TCP312 w/TCPA300 providing 100 MHz bandwidth and a maximum current of 30A DC.
Product Type
www.tektronix.com/accessories
1
Measurement Errors and Manual Calculations Are Now a Thing of the Past
With this new series of current measurement tools, automatic control and on-screen scaling and units is provided for users of T ektronix TDS3000,TDS400A, TDS500,TDS600, TDS700, TDS5000, TDS6000 and TDS7000 series oscilloscope systems.
Status LEDs quickly show you TCP300/400 series operating status or potential error con­ditions that may have caused measurement errors in the past.
The TCP300 / TCP400 Current Measurement Systems seamlessly integrate with your TDS series oscilloscope and the TDSPWR2 software
package to easily make those time consuming power measurements and calculations for you.
Even non-TEKPROBE systems can use the TCPA 300/400 series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA 300/400 series range setting.
AC/DC Current Measurement Systems
TCPA300 •TCP312 •TCP305 •TCP303 •TCPA400 •TCP404XL
Characteristics
TCP312 w/TCPA300 TCP305 w/TCPA300 TCP303 w/TCPA300 TCP404XL w/TCPA400
Bandwidth (–3 dB) DC – 100 MHz DC – 50 MHz DC – 15 MHz DC – 2MHz*
1
Rise Time ≤3.5 ns ≤7 ns ≤23 ns ≤175 ns Maximum Current Ratings: High Current Sensitivity Range 10 A/V Range 10 A/V Range 50 A/V Range 1A/mV Range
DC (continuous) 30A 50A 150A 500A (750A*
2
) RMS (sinusoidal) 21.2A 35.4A 150A 500A Peak Pulse 50A 50A 500A 750A
Low Current Sensitivity Range 1 A/V Range 5 A/V Range 5 A/V Range N/A DC (continuous) 5A 25A 25A RMS (sinusoidal) 3.5A 17.7A 17.7A Peak Pulse 50A 50A 500A
DC Accuracy ±3% of reading ±3% of reading ±3% of reading (10 ºC to 50 ºC) ±3% of reading (Operating temp 0 ºC to 50 ºC) +3%/–6% of reading
(0 ºC to <10 ºC)
DC Accuracy,Typical ±1% of reading ±1% of reading ±1% of reading ±1% of reading (Operating temp 23 ºC ±5 ºC)
Nominal
Maximum Bare Wire Voltage For Use With Insulated Wires Only 600V RMS CAT I & II
300V RMS CAT III
Lowest Measurable Current 1 mA 5 mA 5 mA 1A (at ±3% accuracy at DC) Scope Set To 1mV/div and 20 MHz BW Limited Scope Set To 1mV/div and 20 MHz BW Limited
Insertion Impedance 0.08 Ω at 1 MHz 0.035 Ω a t 1 MHz 0.01 a t 1 MHz 0.1 mat 10 kHz (See Curves Below) 0.15 at 10 MHz 0.12 at 10 MHz 0.025 at 5 MHz 0.6 ma t 100 kHz
0.27 at 50 MHz 0.4 at 50 MHz 0.1 a t 15 MHz 8 ma t 1 MHz
0.7 at 100 MHz 16 mat 2 MHz
Typical
Maximum Amp-Second Product 50A*µS – 1A/V 500A*µS – 5A/V 3,000A*µS – 5A/V NA – 1A/mV (Based on Amplifier 500A*µS – 10A/V NA – 10A/V 15,000A*µS – 50A/V Range Setting)
AC Coupling Low <7 Hz (Lo w Pass – 3 dB point) Frequency Bandwidth
Displayed RMS Noise 250 µA
RMS
1.25 mA
RMS
2.5 mA
RMS
250 mA
RMS
(at 20 MHz Bandwidth Limit) Signal Delay 17 ns 19 ns 53 ns 103 ns
(Delay to Output BNC) Inputs (Probe Amplifier) 1 Probe Open Indicator YES Overload Indicator YES Termination Indicator YES Non-compatible Probe Indicator YES
Product Type
www.tektronix.com/accessories
2
Product Type
www.tektronix.com/accessories
3
AC/DC Current Measurement Systems
TCPA300 •TCP312 •TCP305 •TCP303 •TCPA400 •TCP404XL
Characteristics continued
TCP312 w/TCPA300 TCP305 w/TCPA300 TCP303 w/TCPA300 TCP404XL w/TCPA400
Safety Certifications
U.S. NRTL Listing UL3111-1 UL3111-2-032 ; UL3111-1
(Amplifier) (Probe and Amplifier)
Canadian Certification CAN/CSA C22.2 No.1010.1 CAN/CSA C22.2 No.1010.2.032
(Amplifier) CAN/CSA C22.2 No.1010.1
(Probe and Amplifier)
European Union Compliance EN61010-1/A2 EN61010-1/A2; EN61010-2-032
(Amplifier) EN61010-1/A2
(Probe and Amplifier)
Other IEC61010-1/A2 (Amplifier) IEC61010-2-032
IEC61010-1/A2
(Probe and Amplifier) Electromagnetic Compatibility Meets: EC Council Directive 89/336/EEC, FCC Part 15,Subpart B Class A,AS/NZS 2064.1/2 Power Requirements 90 V to 264 V; 47 to 440 Hz; 50 W
(TCPA300/TCPA400 Amplifiers) Maximum CAT II (Auto Switch) Power Requirements (Probes) Requires TCPA300 Amplifier Requires TCPA400 Amplifier Probe Model TCP312 TCP305 TCP303 TCP404XL Warranty 1 Year
Probe Mechanical Characteristics
Probe Cable Length 1.5 meters (60 in.) 2 meters (78.7 in.) 8 meters (315 in.) Probe Jaw Size 3.8 mm (0.15 in.) 21 mm x 25 mm (0.83 x 1.0 in.)
(Max Conductor Size) Length 20 cm (7.87 in.) 26.8 cm (10.55 in.) 26.8cm (10.55 in.)
Width 1.6 cm (0.625 in.) 4.1 cm (1.60 in.) 4.1 cm (1.60 in.) Height 3.2 cm (1.25 in.) 15.6 cm (6.13 in.) 15.6 cm (6.13 in.) Weight 0.15 kg (0.33 lbs.) 0.66 kg (1.45 lbs.) 0.88 kg (1.90 lbs.)
TCPA300 and TCPA400 Mechanical Characteristics
Length 17.3 cm (6.8 in.) Width 16.7 cm (6.6 in.) Height 9.14 cm (3.6 in.) Weight 1.14 kg (2.5 lbs.)
Environmental Characteristics
Temperature – Operating 0 ºC to +50 ºC (32 ºF to 122 ºF) Temperature – Nonoperating –40 ºC to +75 ºC (–40 ºF to 167 ºF) Humidity – Operating 5% to 95% R.H. to +30 ºC (86 ºF)
5% to 85% R.H. +30 ºC to +50 ºC (86 ºF to 122 ºF)
Humidity – Nonoperating 5% to 95% R.H. to +30 ºC (86 ºF)
5% to 85% R.H. +30 ºC to +75 ºC (86 ºF to 167 ºF) Altitude – Operating 2000 m (6800 ft.) maximum Altitude – Nonoperating 12,192 m (40,000 ft.) maximum
*1Calculated from Rise Time. *
2
Derated w/ duty cycle and frequency.
AC/DC Current Measurement Systems
TCPA300 •TCP312 •TCP305 •TCP303 •TCPA400 •TCP404XL
Our most up-to-date product information is available at:
www.tektronix.com
Copyright © 2003,Tektronix,Inc.All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.All other trade names referenced are the service marks, trademarks or regis­tered trademarks of their respective companies.
01/03 HB/XBS 60W-16458-0
Product Type
www.tektronix.com/accessories
4
Contact Tektronix:
ASEAN / Australasia / Pakistan (65) 6356 3900
Austria +43 2236 8092 262
Belgium +32 (2) 715 89 70
Brazil & South America 55 (11) 3741-8360
Canada 1 (800) 661-5625
Central Europe & Greece +43 2236 8092 301
Denmark +45 44 850 700
Finland +358 (9) 4783 400
France & North Africa +33 (0) 1 69 86 80 34
Germany +49 (221) 94 77 400
Hong Kong (852) 2585-6688
India (91) 80-2275577 Italy +39 (02) 25086 1
Japan 81 (3) 3448-3010
Mexico, Central America & Caribbean 52 (55) 56666-333
The Netherlands +31 (0) 23 569 5555
Norway +47 22 07 07 00
People’s Republic of China 86 (10) 6235 1230
Poland +48 (0) 22 521 53 40
Republic of Korea 82 (2) 528-5299
Russia, CIS & The Baltics +358 (9) 4783 400
South Africa +27 11 254 8360
Spain +34 (91) 372 6055
Sweden +46 8 477 6503/4
Taiwan886 (2) 2722-9622
United Kingdom & Eire +44 (0) 1344 392400
USA 1 (800) 426-2200
USA (Export Sales) 1 (503) 627-1916
For other areas contact Tektronix, Inc.at:1 (503) 627-7111
Updated 20 September 2002
CE mark not applicable for
TCP305 and TCP312.
Tektronix Measurement products are
manufactured in ISO registered facilities.
Ordering Information
TCP312
Probe; AC/DC Current,DC to 100 MHz; 30A DC (Requires TCPA300 Amplifier).
TCP305
Probe; AC/DC Current,DC to 50 MHz; 50A DC (Requires TCPA300 Amplifier).
TCP303
Probe; AC/DC Current,DC to 15 MHz; 150A DC (Requires TCPA300 Amplifier).
TCP404XL
Probe; AC/DC Current,DC to 2 MHz; 500A DC (750A DC De-rated With Duty Cycle) (Requires TCPA400 Amplifier).
All TCP300/TCP400 Current Probes Include:
AC/DC Current Probe; Instruction Sheet; Probe Cover; Certificate of Traceable Calibration.
TCPA300
Amplifier; AC/DC Current Probe,DC to 100 MHz, (Requires TCP305 or TCP312 or TCP303 Probes).
TCPA400
Amplifier; AC/DC Current Probe,DC to 50 MHz, (Requires TCP404XL Probe).
All TCPA300/TCPA400 Current Probe Amplifiers Include: AC/DC Current Probe Amplifier;
Instruction/Service Manual; TEKPROBE Interface Cable; Male-to-Male BNC cable (50 ); 50 feedthrough termination; Certificate of Traceable Calibration.
Options TCPA300/TCPA400 Power Plug Options
Opt. A1 – Euro Plug, 220 V,50 Hz. Opt. A2 – UK Plug, 240 V,50 Hz. Opt. A3 – Australian Plug, 240 V,50 Hz. Opt. A5 – Swiss Plug, 220 V,50 Hz. Opt. A6 – Japanese Plug, 100 V,110/120 V,60 Hz. Opt. AC – China Plug, 50 Hz. Opt. A99 – No Power Cord.
Language Options
Opt. L5 – Japanese Manual.
All TCP300/TCPA300/TCP400/ TCPA400 Series
Service Options
Opt. C3 – Calibration Ser vice 3 Years. Opt. C5 – Calibration Ser vice 5 Years. Opt. D1 – Calibration Data Report. Opt. D3 – Calibration Data Report 3 Years
(with Option C3). Opt. D5 – Calibration Data Report 5 Years
(with Option C5).
Opt. R3 – Repair Ser vice 3 Years. Opt. R5 – Repair Ser vice 5 Years.
Recommended Accessories
016-1923-00 – Cover,small Probe Protective; (for TCP305,TCP312,A6302,A6302XL,A6312, TCP202).
016-1924-00 – Cover,large Probe Protective; (for TCP303,TCP404XL,A6303,A6303XL,A6304XL).
016-1922-00 – Case, transit; Current Measurement Systems.
011-0049-02 – 50 feedthrough termination. 012-0117-00 – 50 BNC-to-BNC coaxial cable. 012-1605-00 – TEKPROBE Interface Cable, TCPA300
or TCPA400 Amplifier to TDS series oscilloscopes. 015-0601-50 – Current loop, 1 turn, 50 Ω, BNC
Connector (for TCP305,TCP312, A6302, A6302XL A6312,TCP202,TCP303,A6303,A6303XL).
174-4765-00 – TCPA300/TCPA400 Amplifier calibration adapter.
067-1478-00 – Power Measurements Deskew Fixture, for TCP202, TCP305, TCP312, TCP303, A6302,A6312,A6303, Series Probes.
CT4 – AC current transformer, 20 k Amp (for use with TCP305,TCP312,TCP202,A6302,A6312).
TDSPWR2 – Power Measurement and Analysis Software for TDS5000 and TDS7000 Oscilloscopes.
To order when purchasing oscilloscope: Order:TDS5052PW2,TDS5054PW2,TDS7054PW2,
TDS7104PW2.
To order as upgrade: Order:TDS5UP PW2,TDS7UP PW2.
Loading...