Please read the instruction manual and safety instructions
carefully before using the appliance and keep the instruction manual for reference. For your safety, this appliance
complies with all applicable standards and regulations
(Low Voltage, Electromagnetic Compatibility, Environmental directives etc.).
• Before use, always check that the appliance, plug and power
cord are in good condition.
• The appliance must be used in normal conditions of use as
defined in this notice.
• Never allow any liquid to get into the appliance.
• Do not touch the appliance with wet hands.
• Never insert objects into the appliance (e.g. needles, etc.).
• Do not cover your appliance.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
• Your appliance must be unplugged before any maintenance.
• For maintenance and adjustment operations, please refer to
the “Maintenance” section.
• Ensure that the air purifier is switched off from the supply
mains before removing the guard.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
4
VERY IMPORTANT
The electrical facilities of the room, as well as the installation and use of the appliance must comply with the standards in force in your country.
Do not use your appliance near inflammable objects or
products. In general, you should always place the appliance at least 50 cm away from any object (walls, curtains, aerosols, etc.).
Never place anything on the appliance.
Do not pull on the power cord or the appliance, even
when unplugging it from a wall socket.
This appliance is designed for indoor domestic household
use only. In case of
professional use, inappropriate use or failure to comply
with the instructions, the manufacturer accepts no responsibility and the guarantee does not apply.
Always unroll the power cord completely before use.
Do not use the appliance in a dusty room or a location
where there is a risk of fire.
This appliance must not be used in a humid environment.
Never use the appliance close to a heat source.
The warranty will be invalidated if damage occurs due to
incorrect use.
Do not cover the air inlets or the outlet grid.
Never use the appliance in an inclined or horizontal position. Place the appliance on a flat, stable surface.
In the case of prolonged absence: switch the appliance
off using the button (10) and unplug it.
EN
5
OPERATING PRINCIPLE
The new Intense Pure Air purifier from Tefal enables you to breathe up to 99.99% pure air in your
home and protect your health with 4 filtration levels as described below. Each level is essential
and traps characteristic pollutants:
LEVEL 3:
TRUE HEPA
ALLERGY+ FILTER
• Fine particles
(PM2.5)
• Pollen
• Dust mites
• Animal allergens
• Mold
• Bacteria / viruses
LEVEL 4:
NANOCAPTUR
FILTER
• Formaldehyde
« HOW TO ACHIEVE CLEANER INDOOR AIR »
In addition to using your Intense Pure Air purifier, here are some tips on how to improve the quality of your indoor air:
• Ventilate the rooms for at least 10 min. every day, in summer and winter
• Maintain your ventilation system
• Limit the use of household products
• Do not smoke indoors
• Avoid home fragrances, incense sticks, scented candles, etc.
• Ventilate whenever any work is being conducted in your home and for several
weeks afterwards
• Avoid green plants that are allergenic or need frequent watering
LEVEL 1:
PRE-FILTER
• Dust
• Hair
• Fur
• Lint
LEVEL 2:
ACTIVE CARBON
FILTER
• Volatile organic
components
(VOCs)
• Odors / gases
WHERE TO INSTALL THE APPLIANCE
Place the purifier on a flat, stable surface in the room requiring treatment.
To allow the air to circulate freely, avoid placing the appliance behind curtains, below a window,
item of furniture or shelf unit, or close to any other obstacle, and leave at least 50 cm of free
space on each side of the appliance.
6
BEFORE USING THE APPLIANCE FOR THE FIRST TIME
Make sure that the plastic packaging protecting the lters has been removed before using the appliance.
Also make sure that:
• The voltage of your electrical installation corresponds to the one indicated on the appliance.
• Your appliance can be used with a power plug without an earth connection. It is a class II appliance (double electrical insulation),
• The appliance is positioned in the house as described above,
• The air inlet and outlet grids are completely unobstructed,
• Ensure the 4 filters and front panel have been correctly installed (see section titled filter assembly/dismantling paragraph).
This appliance is fitted with a device that automatically prevents it from operating if the front
door is not correctly assembled.
Inserting and replacing the filters
This appliance is equipped with 4 types of lters:
EN
Pre-filterActive carbon
filter
NB: For optimum performance of the appliance, only use filters provided by TEFAL.
To replace the lters, follow the instructions in the section « Disassembling/Reassembling lters».
Please note: certain filters may emit a temporary slight odour, due to the transport and storage
conditions.
True HEPA
Allergy+ filter
NanoCaptur
filter
SWITCHING THE APPLIANCE ON
Setting the pollution sensors
The appliance is preset to medium sensitivity.
If the air quality indicator remains:
– poor after 2 hours in operation although the air seems to be purified
– excellent for more than 1 hour although the air seems to be polluted
you can adjust the sensor sensitivity as follows:
1. When the air purifier is off, hold down the mode setting button for 3 seconds:
2. Set the sensitivity by briefly pressing the mode setting button:
+ Blue + Purple + Red
Low sensitivityMedium sensitivityHigh sensitivity
• Select high sensitivity if the air purier indicates excellent air quality for more than 1 hour although the air
seems to be polluted.
7
• Select low sensitivity if the air purier continues to indicate poor air quality even though it has been
operating for more than 2 hours and the air seems suciently puried.
3. Press ‘Start/Stop’ button to validate the sensitivity setting.
OPERATION
Start
Briefly press this button to switch the air purifier on or off.
Mode / filtration speed selection
Auto day
Automatic: In this operating mode, the filtration speed automatically adjusts according to the
air quality detected by the particle sensor and the gas sensor. This mode is recommended for
general use.
Auto Night
The filtration speed of your appliance is adjusted for a whisper quiet air flow during the night.
The light intensity of the appliance is also reduced. If pollution is detected, the filtration speed
increases slightly to purify your air but remains quiet to avoid disturbing your sleep.
Boost mode
The highest speed level of filtration.
Silent mode
The whisper quiet speed.
Light
You can change the light intensity of the appliance as you wish or according to the time of day.
PressAir quality indicatorControl panel
1Light upLight up
2Moderate lightModerate light
3OffModerate light
Ionizer function
– The ionizer function releases negative ions into the air. This function is switched off by de-
fault. To activate it, briefly press button 11.
Timer / delayed start
– Timer: When the appliance is on, you can use this button to define the operating duration.
Briefly press the button to select the number of operating hours desired (1, 2, 4 or 8) and the
appliance will automatically turn off at the end of the selected period.
– Delayed start: When the appliance is off, briefly press the button to set the appliance to turn
on in a certain number of hours (1, 2, 4 or 8).
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.