TeeJet 70 User Manual

70 Series Flow Volume Monitor User Guide 98-05075 R2
1. Connections table
View from cable (45-05439) side
Contact Color Description 1 2 Wht/Red Flowmeter Signal 3 4 5 6 7 8 9 Brown Power supply sensor 10 Green GND sensor 11 12
Part # Flowmeter
Calibration #
Pulses/Liter
90-50230 TeeJet 801 83 314 57-00079 LH - 10D 242 916 57-00080 LH - 16D 79 299 57-00081 LH - 20D 50 189 57-00082 LH - 26D 24 91 57-00094 LH - 40D 21 79
Pulses per liter X 3.785 = Pulses per gallon (input into 70 console)
Pulses per gallon / 3.785 = Pulses per liter (input into 70 console)
Input # for 70 Console
Calibration #
Pulses/Gallon
L
7
150
2. Generality
Function Key Description
The unit will power on and show the first working screen
1. Power on Pro
2. Power off
3. Functionality
Function Display Possible actions Comments
Main screen
4. Program
Function Display Possible actions Comments
Access Exit
and
20.2 G/m 15 GA
76.5l/M 5
20.2 G/M
US Units
to scroll between Actual volume and Total volume
CLR for 3 seconds to reset Second line (Actual or Total volume)
l
Push Pro for 3 seconds Push Pro for 3 seconds
15 GAL
The unit will power off
Metric Units
First line : Flow Second line : Actual volume or Total volume
76.5l/M 57 l
Flowmeter Calibration
p/gal
p/l
98
↑ ↓ to modify value
Pro for 3 seconds to go back to main screen
Cal # should be located on the flowmeter tag.
Cal # US = pulses / gallon Cal # Metric = pulses / Liter
2864 Old Rochester Road Springfield, IL 62703
Phone (217) 753-8424 – Fax (217) 753-8426 www.mid-tech.com