Tanita TBF-215GS Owner's Manual

TBF2157021(1)
This device features radio interference suppression in compliance with valid EC Regulation 89/336/EEC.
FEDERAL COMMUNICATIONS COMMISSION NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio or television technician for help.
<Modifications>
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Tanita Corporation may void the user's authority to operate the equipment.
14-2,1-chome,Maeno-cho,Itabashi-ku Tokyo,Japan Tel:(03)3968-2123 / (03)3968-7048 Fax:(03)3967-3766
Dresdener Strasse 25 D-71065 Sindelfingen, Germany
Tel
: 07031-61896
Fax : 07031-618971
Tanita House, Willow Avenue, Denham, Uxbridge, Middlesex UB9 4AF, Great Britain
Tel
: 01895-232355
Fax : 01895-233116
Unit 301-303 3/F Wing On Plaza, 62 Mody Road, Tsimshatsui East, Kowloon, Hong Kong
Tel
: +852-2838-7111
Fax : +852-2838-8667
2625 South Clearbrook Drive Arlington Heights, Illinois 60005 U.S.A. Toll Free : (800) 826-4828 Tel : 847-640-9241 Fax : 847-640-9261 http : //www.tanita.com
3-3 Bis, Rue Charcot, 92200, Neuilly-Sur-Seine, France
Tel
: 01-55-24-99-99
Fax : 01-55-24-98-68
BODY COMPOSITION ANALYZER
TBF-215
INSTRUCTION MANUAL
Please read this INSTRUCTION MANUAL carefully and keep it handy for future reference.
3
2. Specifications
Model TBF-215
Measurement System Tetrapolar Bioelectrical Impedance Analysis Measurement Frequency
50
kHz
Measurement Current 500
μA
Impedance Measurement
Electrode Material Pressure Contact Stainless Steel Foot Pads Measurement Style
Between Both Feet
Measurement Range
150〜900
Ω
Measurement System Strain Gauge Load Cell
Weight Measurement
Maximum Capacity 200
kg
440
lb
31st6
lb
Minimum Graduation 0.1
kg
0.2
lb
0.2
lb
90〜213
cm
3〜7
ft
Height Measurement
Range of Measurement
1cmincrements
0.5
in
increments
Clothes Weight
0200kg/0.1kgincrements 0440lb/0.2lbincrements
09st13.8lb/0.2lbincrements
Gender
Male/Female
Body Type
Standard/Athletic
Input Items Age
7〜99 years old/1 year
increments
Height Rod
90213cm/1cmincrements
3ft〜7ft/0.5inincrements
Height
Manual Input
90249cm/1cmincrements
3ft〜7ft11.5in/0.5inincrements
Target Body Fat %
4〜55 %
Target Body Fat %
4〜55 %
Weight
0200kg/0.1kgincrements 0440lb/0.2lbincrements
031st6lb/0.2lbincrements
Gender
Male/Female
Body Type
Standard/Athletic
Display
Age
7〜99 years old/1 year
increments
Rod
90213cm/1cmincrements
3ft〜7ft/0.5inincrements
Height
Manual
90249cm/1cmincrements
3ft〜7ft11.5in/0.5inincrements
Fat %
1〜75 % / 0.1 %
increments
Body Type
Standard/Athletic
Gender
Male/Female
Age
7〜99 years old/1 year
increments
Output Items
Rod
90213cm/1cmincrements
3ft〜7ft/0.5inincrements
Height
Manual
90249cm/1cmincrements
3ft〜7ft11.5in/0.5inincrements
Weight
2200kg/0.1kgincrements 4.4440lb/0.2lbincrements
4.431st6lb/0.2lbincrements
Print BMI 0.1 increments Out BMR 1kJincrements / 1kcalincrements
Impedance
150900Ω/1Ω increments
Fat % 175 % / 0.1 % increments Fat Mass
0.1kgincrements
0.2lbincrements
FFM
0.1kgincrements
0.2lbincrements
TBW
0.1kgincrements
0.2lbincrements
Others
Desirable Range for FAT% and FM ( Standard and 2079 years old ONLY )
Display 3 Rows, 5Digits LCD Cable Length Between Platform and Control Box
2m/6ft6.5in
Output Data Interface RS-232C ( D -sub 9 pins Male Connector ) Power Source AC Adapter ( included ) Center Minus Rated Power DC5V 3.5A Power Consumption 17.5W Temperature Range of usage 035˚C/3295˚F
Platform 15.6kg / 34.4lb
Weight of Equipment
Control Box 0.9kg / 2.0lb
1. Table of Contents
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
2
2. Specifications
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
3
3. Important Notes for Users
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
4
Caution Symbols
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
4
Maintenance
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
5
General Instructions for Accurate Measurement
●●●●●●●
5
4. Components
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
6
Overview
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
6
Control Panel Functions
●●●●●●●●●●●●●●●●●●●●●●●●●●●●
7
5. Set Up
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
8
Assembly Instructions
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
8
Loading Printer Paper
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
9
Pre-Set Printer Functions
●●●●●●●●●●●●●●●●●●●●●●●●●●
10
Setting the Original Mode
●●●●●●●●●●●●●●●●●●●●●●●●●
12
6. Operating Instructions
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
13
Body Composition Analysis
●●●●●●●●●●●●●●●●
13,14,15,16
Weight Only Function
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
17
7. Explanation of the Print Out
●●●●●●●●●●●●●●●●●●●●●●●●●●
18
8. Trouble Shooting the Printer
●●●●●●●●●●●●●●●●●●●●●●●●●●
19
9. General Trouble Shooting
●●●●●●●●●●●●●●●●●●●●●●●●●●●●
20
10. RS - 232 C Interface Instructions
●●●●●●●●●●●●●●●●●●●●●
21,22
1.
Table of Contents
2
5
Maintenance
In order to insure optimum performance of this Body Composition Scale, please
observe the following instructions:
Unplug the unit from the wall outlet when it will not be in use for long periods of time.
Always turn the equipment off before unplugging from a wall outlet.
Never disassemble the equipment. Always call the nearest Tanita dealer or branch office for instruction.
In order to reduce the risk of a short circuit, please keep any liquid or metal objects (paper clips, etc.) away from
the printer.
Do not drop the unit, and avoid locations with constant vibration.
Avoid placing the platform or display in direct sunlight, or too close to a heating unit.
Avoid rapid temperature fluctuations.
Excessive humidity may damage the equipment.
When transferred to any location where there is a difference of more than 20˚C(40˚F), wait 2 hours before using.
General Instructions for Accurate Measurement
The body composition analyzer is designed for standard and athletic individuals. However, certain individuals may
not receive accurate results, as they fall outside the population for which Tanita equations were developed.
Because this body composition analyzer uses a minor electric current to measure impedance (electrical resistance),
best results will be observed when measurement is taken in bare feet.
If there are calluses on the soles of the feet, or a client is wearing thin nylons, accurate measurement may still be
possible. Place 0.5 ml of saline or water in the center of each electrode. This will act as a conductant, and may
allow the current to pass freely through a thin barrier.
Poor contact between the feet and electrodes may produce an error message. Heels should be placed directly on
top of the posterior electrodes, while the front part of the foot needs to be in contact with the anterior electrodes.
Also, make sure the soles of feet are free of excess dirt, as this may also act as a barrier to the mild current.
Keep the electrodes clean by wiping them with disinfectant.
False results may be reported after excessive food/fluid intake, or after periods of intense exercise.
Interpretation of Results
The data provided by this machine, as well as any supplementary information such as diet or exercise programs
based on this data, should be interpreted by a licensed professional.
For more information regarding Accurate Measurement, please refer to the Technical Notes booklet.
4
WARNING
Individuals with a Pacemaker or Other Internal Medical Devices:
Because Tanita`s Body Composition Analyzers send a weak electrical current through
the body, Individuals Who Have a Pacemaker or Other Internal Medical Devices
Should Not Use This Product. The weak electrical signal may cause such internal
devices to malfunction.
Cross Contamination
The Body Composition Analyzer should be used with bare feet. Please be sure to clean
the scale platform with appropriate disinfectant after each use. Never pour any liquid
directly on the scale platform, as it may leak and cause internal damage. Use a soft
cloth and appropriate disinfectant or mild cleaners to wipe off platform. Do not wipe
the platform with strong chemicals.
Please consult your Physician before begining any weight management program and
for help in establishing your target body fat percent. Tanita Corporation is not
responsible for establishing individualized target body fat percent values.
To reduce the risk of fire hazards or equipment damage, use only the original AC
adapter provided by TANITA.
WARNING
Inserting and Removing the Power Cord
To reduce the risk of electric shock or product damage, never insert or remove the
power cord with wet hands.
To avoid a fire hazard, make sure the wall outlet is functioning properly; avoid using
multiple outlet extension cords.
CAUTION
To reduce the chance of inaccurate measurement, be sure to place the weighing
platform on a flat and stable surface.
To reduce risk of injury or equipment malfunction, always step on the platform slowly.
When handling printer unit, avoid any sharp edges.
To reduce the risk of fire hazards or equipment damage, use only the original AC
adapter provided by TANITA.
When transferring this product, be sure that it remains in an upright position, and do
not carry from the height rod only. Hold the plate underneath the base. Failing to do so
may damage the height rod, or the weighing platform.
Do not lean against the height rod.
Caution Symbols
Thank you for purchasing this precision crafted Tanita product. For optimum performance and safety, please familiarize
yourself with the Caution Symbols below. These symbols are designed to alert the user to potential hazards when using this
equipment. Ignoring these Caution Symbols may result in serious injury, or damage to the product.
Please be sure to review before proceeding with the INSTRUCTION MANUAL.
3.
Important Notes for Users
WARNING
This symbol indicates the possibility of serious injury if the product is mishandled or instructions are ignored.
WARNING
This symbol indicates the possibility of ELECTRICAL SHOCK. Please pay special attention to sections which bear this mark.
CAUTION
This symbol indicates the possibility of physical injury or equipment damage if instructions are ignored.
This symbol indicates general precautions that should be taken when using this product.
Body Type Keys
To select the appropriate body type
Tanita defines “athlete” as a person involved in intense physical activity of at least 10 hours per week and who has a resting heart rate of approximately 60 beats per minute or less. Tanita’s athlete definition includes “lifetime of fitness” individuals who have been fit for years but currently exercise less than 10 hours per week.
Tanita’s athlete definition does not include “enthusiastic beginners” who are making a real commitment to exercising at least 10 hours per week but whose bodies have not yet changed to require the Athlete mode.
Please see Technical Notes booklet for further explanation.
7
Rear View of Control Panel
RS - 232 C Port
Jack for the weighing platform
DC Jack
Control Panel Functions
Feed Key
Advances the print paper
ON/OFF Key
Turns the power on or off
Clothes Key
To specify clothes weight
Weight Only Key
Measures body weight only
Numerical Key Pad
Number Entry Keys
CE Key
Clear Entry key
Kg/Lb./(st.lb) Key
Changes measurement unit
Confirm Height Key
Height Entry
Overview
6
Weight Platform
Control Box
AC Adapter
Printer Cover
Control Panel
Digital Display
Connection Cable
Power Cord
Level Gauge
Height Rod
Height Setting Button : Height Confirmation
Height Bar
Posterior Platform Electrodes
Anterior Platform Electrodes
Printer Dispenser Cover
Bottom Plate
Cord Cover ( Under Bottom Plate )
4. Components
Loading...
+ 8 hidden pages