Model FSE65R….…69” Long x 34”Deep x 60”High*
Model FSI65R……..66 1/4” Dia.” x 60”High*
*Levelers extended 1 5/8” below base frame
888 E. Porter Road · Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com
I:\Oper Manual\Oasis\FSE65R_FSI65R_55112.pub
1
Model FSI65R
Rev B Date: 1.12.2011
TABLE OF CONTENTS
OVERVIEW AND WARNINGS ….…………………..……………………..…….………….....…………..
INSTALLATION ……………………………………………...……………………………………………...
FIELD WIRING / MAIN POWER SWITCH / TEMPERATURE CONTROLLER [MODEL FS E65R
ONLY]….…………………………………………………………………………….………………………..
FIELD WIRING / MAIN POWER SWITCH / BALLAST BOX [MODEL FSI65R ONLY] …………….
BALLAST BOX ACCESS [MODEL FSE65R] ……………………………………….…………………..
BALLAST BOX / ELECTRICAL BOX ACCESS [MODEL FSI65R] …………………………………..
POWER-UP CHECK / LIGHTS …………………………………………………………………………….
MAINTENANCE FUNDAMENTALS - SHELF ASS’Y REMOVAL / LIGHT FIXTURES .…………...
MAINTENANCE FUNDAMENTALS - HONEYCOMB AIR DIFFUSERS ……………………………..
REFRIGERATION FUNDAMENTALS ….………...…………………………..………………………….
CLEANING SCHEDULE - TO BE PERFORMED BY STORE PERSONNEL .……………………….
TROUBLESHOOTING - GENERAL ISSUES (PAGES 1 of 3) ………………………………………...
TROUBLESHOOTING - CONDENSING SYSTEM (QUALIFIED SERVICE TECHNICIANS) ……...
TROUBLESHOOTING - EVAPORATOR SYSTEM (QUALIFIED SERVICE TECHNIC I ANS) ……..
SERIAL LABEL LOCATION & INFORMATION LISTED / TECH INFO & SERVICE…….……… ….
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER)…….
CAREL TEMPERATURE CONTROLLER OPERATING INSTRUCTIONS………………................
TECHNICAL SERVICE CONTACT INFORMATION & WARRANTY INFORMATION ..…………...
3
4
5
6
7
8
9
10
11
12
13
14-16
17
18
19
20
21-23
24
2
OVERVIEW AND WARNINGS
OVERVIEW
These Structural Concepts Oasis® service cases are designed to merchandise packaged products at
5°C / 41°F or less product temperatures.
These cases should be installed and operated according to this operating manual’s instructions to
insure proper performance. Improper use will void warranty.
This unit is designed for the display of products in ambient store conditions where temperatures and
humidity are maintained within a specific range.
For NSF® Type 1 Conditions (most cases): ambient conditions are to be at 55% max. humidity / 75°F.
For NSF® Type 2 Conditions: ambient conditions are to be at 60% maximum humidity / 80°F.
If unsure if your case is Type 1 or Type 2, contact Structural Concepts Technical Service (see
Technical Service section in this manual for phone number).
Caution: Do not allow air conditioning, electric fans, open doors or windows to create air currents
around display case as this may detrimentally affect proper case temperatures and operation.
ATTENTION INSTALLER
This equipment must be installed in compliance with all
applicable NEC, federal, state and local plumbing codes.
WARNING
ELECTRICAL
HAZARD
WARNING
KEEP HANDS
CLEAR
WARNING
HOT
SURFACE
CAUTION
WARNING
Risk of electric shock.
Disconnect power before servicing unit
WARNING
Hazardous moving parts. Do not operate unit with covers removed.
Fan blades may be exposed when deck panel is removed.
Disconnect power before removing deck panel.
WARNING
For Self-Contained Cases: Evaporator Pan is Hot!
Disconnect and allow to cool before cleaning or removing from case.
CAUTION
Lamps have been treated to resist breakage
and must be replaced with similarly treated lamps.
WARNING! ADVERSE CONDITIONS / SPACING ISSUES
Performance issues caused by adverse conditions are NOT covered by warranty.
End panels are to be at least 6-inches away from structures to prevent condensation.
Unit must be kept at least 15-feet from exterior doors, overhead HVAC vents or any
air curtain disruption to maintain proper temperatures.
Unit must not be exposed to direct sunlight or any heat source (ovens, fryers, etc.).
Tile floors, low ceilings or small rooms will increase noise level. Whisper Cool
compressor blanket or remote unit may resolve noise level issues.
Keep at least 8-inch clearance above unit for air discharge (self-contained units only).
3
INSTALLATION
1. Remove Unit From Skid
For your safety, the equipment is furnished
with a properly grounded cord connector.
Do not attempt to defeat the grounded
connector.
Remove case from skid and place in proper
location.
Plug cord into certified electrical outlet with
a ground.
2. Positioning Unit
Place unit into desired location before
leveling.
3. Cases With Levelers: Adjust Levelers
After case is in position, adjust case so it is
level and plumb (see illustration at right).
You may need to remove front and/or rear
Toe-Kick to access levelers.
Use adjustable wrench (and possibly a pry
bar) to adjust leveler.
Do not use pry bar on toe-kick (it may
buckle).
Do not use pry bar on end panel (it may
chip).
Use pry bar ONLY on base frame to avoid
damaging case.
Use a block to reach base frames with pry
bar.
See illustrations at right.
Provide
support
while
removing
from
skid
Carefully slide skid out
from under unit
Adjustable
Wrench
Pry Bar
4
Block
Leveler
Base
Frame
Toe-Kick
FIELD WIRING / MAIN POWER SWITCH / TEMPERATURE CONTROLLER [MODEL FSE65R ONLY]
To access field wiring box, remove front panel by
simply lifting up and off (no screw removal required).
Then remove Left Side Panel Clip (by removing
three screws). See illustration at right for location.
Remove two (2) Left Panel Retaining Screws (see
illustration at right for location).
Main Power Switch
Flip-Up Door is at left side of case (as shown below).
Turn Main Power Switch on to energize case (see
below for illustration).
Temperature Controller
Temperature Controller is at left of Main Power
Switch.
See illustration below.
See the Carel Temperature Controller Operating
Instructions section of this manual for additional
details.
Left Panel
Retaining
Screws
Field
Wiring
Box
Temperature
Controller
ON
OFF
Main Power
Switch
Left Side
Panel Clip
View of Flip-Up Door
5
FIELD WIRING / MAIN POWER SWITCH / BALLAST BOX [MODEL FSI65R ONLY]
Note 1
refrigeration package at underside of case].
: Illustration shown is remote unit [no
Note 2: Illustration shown has oval toe-kick
removed for illustrative purposes.
Field Wiring Box
Access to Field Wiring Box is to be
accomplished by a licensed electrical
contractor.
Main Power Switch
ON
OFF
To access field wiring box, remove oval toe-kick
by simply lifting up and off (no screw removal required).
Main Power Switch
Flip-up door is on oval toe-kick (view shown
below has oval toe-kick removed for illustrative
purposes only).
Turn Main Power Switch on to energize case
(see below for illustration).
Ballast
Box
Electrical Box
[Houses Main
Power Switch]
Panel Hooks
(Typical)
Flip-Up Door [Covers
Main Power Switch]
View of Flip-Up Door [Removed
Along With Oval Toe-Kick]
Field
Wiring
Box
6
BALLAST BOX ACCESS [MODEL FSE65R]
Ballast Box Access
Warning! Turn power off and/or disconnect power before providing maintenance and
service to unit.
Assembly or disassembly and servicing to be accomplished by licensed electrical
contractor.
To access field wiring box, remove front panel by lifting up and off (no screw removal required).
Remove Left Side Panel Clip (by removing three screws). See illustration below for location.
Remove two (2) Left Panel Retaining Screws (see illustration below for location).
Ballast is located on left side of case (see illustration below)
Remove four (4) screws and ballast box will drop down allowing access.
Return all pieces and parts to unit after access.
Warning! Turn power off and/or disconnect power before providing maintenance and service to
unit.
Assembly or disassembly and servicing to be accomplished by licensed electrical contractor.
To access field wiring box, remove front panel by lifting up and off (no screw removal required).
Access ballasts, terminal strip and contactor by removing four (4) screws and covers.
Return all pieces and parts to unit after access.
Ballasts
[In Ballast Box]
8
Terminal Strip
[In Elec. Box]
Contactor
[In Elec. Box]