Data Sheet
DHCE 8/50
Instantaneous Single Phase Electric Water Heater
Delivers hot water not exceeding 50°Celsius in accordance with AS3498*
The advantages
Electronically controlled to save energy and waterTemperature selection up to a maximum of 50°Celsius in
accordance with AS3498*
1.5L/min
Three selectable temperatures for greater convenience, note that
output temperature will be impacted by cold water inlet
temperature : 40°C ●● : 45°C ●●● : 50°C
No flue, ventilation or safe tray requiredCompact design for space saving installation flexibilityAvailable in electrical size:
DHCE 8/50 - 9.5kW, 40 Amps per phase, single phase 240V
WaterMark approved, licence number WMKA21273, AS3498
Ideal installation areas
^
50˚C
SinkBasin
For more information on the right Stiebel Eltron water heater for
your project please contact our Technical Services Department on
free call 1800 153 351 (Australia).
*This appliance delivers hot water not exceeding 50°Celsius in accordance with AS3498. Refer to AS/NZS3500.4, local requirements and installation instructions to determine if additional delivery temperature control is required.
^Dependent on model selected
01 | 02Free Call 1800 153 351 | www.stiebel.com.au
Data Sheet DHCE 8/50 AUG 2015
100 mm
200 mm
35 mm
G1/2
G1/2
110 mm.
59 mm.
280 mm.
360 mm.
270 mm.
264 mm.
9 mm.
50 mm.
65 mm
Hot water outlet Cold water inlet
Data Sheet
DHCE 8/50
Instantaneous Single Phase Electric Water Heater
Delivers hot water not exceeding 50°Celsius in accordance with AS3498*
SINGLE PHASE ELECTR IC
Model number DHCE 8/50
Rated output (240V) 9.5kW
Rated current (240V) 40 Amp
Phases 1/N/PE/AC 220..240V
Electrical installation As per AS/NZS3000
Installation requirements AS/NZS3500.4.2 & local requirements
Switch on flow rate 1.5 L/min
Permissible operating pressure 1000 kPa
Temperature adjustment 40˚C ●● 45˚C ●●● 50˚C
IP Rating IP25
Height 360 mm
Width 200 mm
Depth 110 mm
Weight (filled with water) 2.45 kg
Colour silver look
Nominal capacity 0.45L
Approvals WaterMark Lic No. WMKA21273. AS3498
Equipment
For one/several draw off points Yes /Yes
Heating system Tubular
Electronic flow rate control -
Electronic air detection system -
Accepts pre-heated water (solar) -
Programmable temperature -
Wellness shower programs -
ECO energy & water function -
Optional accessories
Radio remote control primary
Radio remote control secondary
-
-
Selecting the right Stiebel Eltron instantaneous water heater
Thank you for considering the Stiebel Eltron instantaneous water heater, with over 90 years of hot water technology experience we are sure you will be happy with your choice of a Stiebel Eltron instantaneous water heater.
The temperature rise table will assist you in determining the appropriate size of instantaneous water heater required for your application. The required temperatures at specific flow rates will determine the size of system needed. Our customer support representatives can be contacted on our free call number 1800 153 351 to assist in selecting the appropriate system/systems for your project.
Installation close to the point of use
The Stiebel Eltron DHCE instant water heaters compact design allows for ease of installation close to the point of use. In order to minimise thermal losses in the pipe work the water heater should be installed as close to the point of use as possible.
Electrical installation
This water heater must be installed in accordance with AS/NZS3000 electrical regulations by a qualified installer.
Plumbing installation
This water heater must be installed in accordance with AS/NZS3500.4.2 and local authority regulations by a qualified installer.
Warranty
For full warranty information please visit www.stiebel.com.au.
Technical Support
Stiebel Eltron (Aust) Pty Ltd Free Call (Australia): 1800 153 351 Telephone: (03) 9645 1833 Website: stiebel.com.au
Temperature rise chart^ DHCE 8/50
Add the below temperature to the cold water inlet temperature. Temperature will also be dependent on the output dial setting.
4L/min 33°C
6L/min 22°C
8L/min 17°C
10L/min -
12L/min -
14L/min -
^Please not e temperature r ise is based o n connecti on to 240V. Our customer support representatives can be contacted on our free call number
1800 153 351 to assist in selecting the appropriate system/systems for your project.
STIEBEL ELTRON is committed to our policy of continual improvement, some features may have subsequently been changed or even removed. Our advisors will be happy to consult with you regarding the currently applicable equipment features. The images used in this brochure are for reference only.
DHCE 8/50 instantaneous single phase electric water heater
Data Sheet DHCE 8/50 AUG 2015
01 | 02Free Call 1800 153 351 | www.stiebel.com.au