ElementU.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
WattageINPUTF°36F°40F°54F°60F°72F°80F°90F°100F° 108F° 120F° 126F°
(Upper/Lower)KWC°20C° 22.2C° 30C° 33.3C° 40C° 44.4C° 50C°55.5C° 60C° 66.6C° 70C°
NON-SIMULATANEOUS OPERATION
/1500GPH171511108 8 7 6655
/2000GPH2320151411109 8876
/2500GPH2825191714131110988
3000/3000GPH3430232017151412111010
4000/4000GPH4541302723201816151413
4500/4500GPH5146343025232018171514
5000/5000GPH5651383428252320191716
6000/6000GPH6861454134302724232019
SIMULATANEOUS OPERATION
3000/3000GPH6861454134302724232019
4000/4000GPH9081605445413632302726
4500/4500GPH10191686151464136343029
5000/5000GPH113101756856514541383432
6000/6000GPH135122908168615449454139
1.5LPH6458433832292623211918
2.0LPH8577575143383431282624
2.5LPH10796716453484338363230
3.0LPH12811585 77 64 58 51 46433837
4.0LPH17015311410285776861575149
4.5LPH19217312811596867769645855
5.0LPH213192142128107968577716461
6.0LPH25623017015312811510292857773
6LPH25623017015312811510292857773
8LPH34130722720517015313612311410297
9LPH384345256230192173153138128115110
10LPH426384284256213192170153142128122
12LPH511460341307256230205184170153146
FOR PCE 6 MODELS
Approx.
Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x KW of one element; for simultaneous element operation
= 4.1 gal. x 2/3 KW of both elements. For other rises multiply element KW as previously explained by 410 and divide by temperature rise. Full load current for single phase
= total watts : voltage.
2
FOREWORD
Thank you for buying this energy efficient water heater from
State. We appreciate your confidence in our products. Detailed
installation diagrams are in this manual. These diagrams will
serve to provide the installer with a reference for the materials
and method of piping suggested. IT IS NECESSARY THAT ALL
WATER PIPING AND THE ELECTRICAL WIRING BE INSTALLED
AND CONNECTED AS SHOWN IN THE DIAGRAMS.
In addition to these instructions, the water heater must be installed
in accordance with local codes and the authority having
jurisdiction.
GENERAL SAFETY INSTRUCTIONS
BE SURE TO TURN OFF POWER WHEN WORKING ON OR
NEAR THE ELECTRICAL SYSTEM OF THE HEATER. NEVER
TOUCH ELECTRICAL COMPONENTS WITH WET HANDS OR
WHEN STANDING IN WATER. WHEN REPLACING FUSES
ALWAYS USE THE CORRECT SIZE FOR THE CIRCUIT.
The principal components of the heater are identified on page
6. The model and rating plate on page 5 interprets certain
markings into useful information. Both of these references
should be used to identify the heater, its components and optional
equipment.
reduce the risk of injury under these conditions, it is recommended
that the hot water faucet be opened for several minutes at a nearby
kitchen sink before using any electrical appliance connected to the
hot water system. If hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as the water
begins to flow. THERE SHOULD BE NO SMOKING OR OPEN
FLAME NEAR THE FAUCET AT THE TIME IT IS OPENED.
CAUTION
AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK
OF ELECTRIC SHOCK OR POSSIBLE ELECTROCUTION. THE
GROUND SCREW AT THE JUNCTION BOX IS FOR BONDING
THE HEATER TO A GROUNDED SERVICE ENTRANCE
CONDUCTOR, A GROUNDED SERVICE ENTRANCE RACEWAY,
OR AN EARTH GROUNDING ELECTRODE CONDUCTOR.
WARNING
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT
IN SERIOUS PERSONAL INJURY OR DEATH.
REQUIRED ABILITY
INSTALLATION OR SERVICE OF THIS WATER HEATER
REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED
TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND
ELECTRICAL WORK ARE REQUIRED.
WARNING
FOR CALIFORNIA INSTALLATION THIS WATER HEATER MUST
BE BRACED, ANCHORED, OR STRAPPED TO AVOID FALLING
OR MOVING DURING AN EARTHQUAKE. SEE INSTRUCTIONS
FOR CORRECT INSTALLATION AND PROCEDURES.
INSTRUCTIONS MAY BE OBTAINED FROM YOUR LOCAL
DEALER, WHOLESALER, PUBLIC UTILITIES OR
CALIFORNIA’S OFFICE OF STATE ARCHITECT, 400 P STREET,
SACRAMENTO, CALIFORNIA 95814.
INSULATION BLANKETS
Insulation blankets available to the general public for external
use on electric water heaters are not approved for use on your
State water heater. The purpose of an insulation blanket is to
reduce the standby heat loss encountered with storage tank water
heaters. Your State water heater meets or exceeds the National
Appliance Energy Act standards with respect to insulation and
standby loss requirements, making an insulation blanket
unnecessary.
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions (See page 5 for identification
of components mentioned below). Failure to follow these
instructions can result in fire, serious personal injury or death.
• Do not cover the temperature & pressure relief valve.
• Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
• Do obtain new labels from State Water Heaters for placement
on the blanket directly over the existing labels.
WARNING
EXTENDED NON-USE PERIODS
HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER
SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN USED
FOR A LONG PERIOD OF TIME (GENERALLY TWO WEEKS OR
MORE).
HYDROGEN GAS IS EXTREMELY FLAMMABLE. To
CAUTION
GENERAL
The installation must conform to these instructions, the local code
authority having jurisdiction, and the requirements of the power
company. In the absence of code requirements follow the current
edition of NFPA-70, The National Electrical Code which may be
ordered from: National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269.
LOCATION
The water heater should be located as close as possible to/or
centralized to the water piping system. The water heater should
be located in an area not subject to freezing temperatures.
The heater should be located in an area where leakage of the
tank or connections will not result in damage to the area adjacent
to the heater or to lower floors of the structure.
When such locations cannot be avoided, a suitable drain pan
should be installed under the heater.
Such pans should be at least two inches deep, have a minimum
length and width of at least two inches greater than the diameter
of the heater and should be piped to an adequate drain.
Drain pans suitable for these heaters are available from your
distributor or State Water Heaters, 500 Tennessee Waltz Parkway,
Ashland City, TN 37015.
Water heater life depends upon water quality, water pressure and
the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a drain pan piped
to a drain. However, unanticipated damage can be reduced or
prevented by a leak detector or water shut-off device used in
conjunction with a piped drain pan. These devices are available
from some plumbing supply wholesalers and retailers, and detect
and react to leakage in various ways:
• Sensors mounted in the drain pan that trigger an alarm or turn
off the incoming water to the water heater when leakage is
detected.
3
• Sensors mounted in the drain pan that turn off the water supply
to the entire home when water is detected in the drain pan.
• Water supply shut-off devices that activate based on the water
pressure differential between the cold water and how water
pipes connected to the water heater.
• Devices that will turn off the gas supply to a gas water heater
while at the same time shutting off its water supply.
CLEARANCES
CALCULATING
AMPERAGE/OVERCURRENT PROTECTION
The heaters come from the factory in two configurations:
1. Two wire C-2 circuit for single element heater equipped with a
high limit control, single phase power input.
2. Four wire A-8 circuit for dual element heater equipped with
two high limit controls, single phase or three phase power
input.
A minimum clearance of 4” must be allowed for access to
replaceable parts such as thermostats, drain valve and relief valve.
Adequate clearance for servicing this appliance should be
considered before installation, such as changing the anodes, etc.
FLOOD WARNING
IF THE HEATER BECOMES IMMERSED IN WATER UP TO OR
ABOVE THE LEVEL OF THE BOTTOM OF THE ELEMENT
DOORS, THE HEATER SHOULD BE EXAMINED BY A
COMPETENT SERVICE PERSON BEFORE IT IS PLACED IN
OPERATION.
CHEMICAL VAPOR CORROSION
Water heater corrosion and component failure can be caused by
the heating and breakdown of airborne chemical vapors. Spray
can propellants, cleaning solvents, refrigerator and air conditioning
refrigerants, swimming pool chemicals, calcium and sodium
chloride, waxes, and process chemicals are typical compounds
which are potentially corrosive. These materials are corrosive at
very low concentration levels with little or no odor to reveal their
presence. Products of this sort should not be stored near the
heater.
ELECTRICAL (GENERAL)
Check the heater model and rating plate information against the
characteristics of the branch circuit electrical supply. DO NOT
CONNECT THE HEATER TO AN IMPROPER SOURCE OF
ELECTRICITY. Contact the heater supplier for conversion
information if necessary.
The heater with dual elements is factory wired for connection to
a three wire, three-phase delta branch circuit, non-simultaneous
operation. In addition a ground conductor is required.
Element connection is for non-simultaneous operation. This
means only one element at a time operates. The wiring diagram,
on page 5, shows the heater may be field converted to
simultaneous element operation by moving the red wire on
“J” terminal to L1. It is then possible for both elements to operate
at once as determined by the thermostats. Regardless of
element connection the heater operates in an “unbalanced”
fashion.
The heater may be field converted to single-phase operation by
moving the wire on L3 of the terminal block to L2. L3 is not used,
see page 5.
The heater, now in single-phase non-simultaneous operation, may
be field-converted to single phase simultaneous operation by
moving the red wire on terminal “J” to L1, see page 5.
This is an example of calculating heater amperage for both types
of element operation. From this, the branch circuit conductor
and overcurrent protection sizing can be established.
The example is of a three-phase 240 volt unit with two, 6 kw
elements. The notations are for units field converted to
single-phase. Check the heater model and rating plate for actual
specifications and substitute those values in the following.
Voltage applied to the heater should not vary more than +5%
to -10% of the model and rating plate marking for satisfactory
operation.
DO NOT ENERGIZE THE BRANCH CIRCUIT FOR ANY REASON
BEFORE THE HEATER TANK IS FILLED WITH WATER.
SO WILL CAUSE THE HEATING ELEMENTS TO BURN OUT.
The factory wiring is attached to a terminal block within the external
junction box unit. The branch circuit is connected to the terminal
block within this junction box. The water heater should be
connected to a separate, grounded, branch circuit with overcurrent
protection and disconnect switch. The water heater should be
grounded in accordance with national and local codes.
DOING
BRANCH CIRCUIT
The branch circuit wire size should be established through
reference to the current edition of NFPA-70, the
National Electrical Code or other locally approved source in
conjunction with the heater amperage rating. For convenience,
portions of the wire size tables from the Code are reproduced
here. The branch circuit should be sized at 125 percent of the
heater rating and further increase wire size as necessary to
compensate for voltage drop in long runs.
3000 : 240 = 12.5 amps*3000 : 240 = 12.5 amps*
12.5 x 1.73 = 21.6 amps
*NOTE: as a single-phase*NOTE: as a single-phase
non-simultaneous unit.simultaneous unit the
total is:
12.5 x 2 = 25 amps
The rating of the overcurrent protection should be computed on
the basis of 125 percent of the total connected load amperage.
Where the standard ratings and settings do not correspond with
this computation, the next higher standard rating or setting should
be selected.
Portion of Table 310-16 (NFPA-70) follows:
Allowable Ampacities of Insulated Copper Conductors. Not more
than three conductors in Raceway or Cable or Direct Burial (Based
on Ambient Temperature of 30° C, 86° F).
These ampacities relate only to conductors described in Table
310-13 in Code.
For ambient temperatures over 30° C (86° F), see Correction
Factors, Note 13 in Code.
4
Size Temperature Rating of Conductor
See Table 310-13 in Code
Allowable Ampacities of Insulated Aluminum and Copper -Clad Aluminum Conductors.
Not more than three conductors in Raceway or Cable or Direct Burial (Based on Ambient Temperature of 30° C, 86° F. These
ampacities relate only to conductors described in Table 310-13 in Code.
For ambient temperatures over 30° C (86° F), see Correction Factors, Note 13 in Code.
WIRING DIAGRAMS
A-8 CIRCUIT FOR DUAL ELEMENT HEATER
C-2 CIRCUIT
FOR SINGLE
ELEMENT HEATERS
EQUIPPED WITH HIGH
LIMIT CONTROL
FACTORY WIRED
---------- FIELD WIRING
† WHITE FOR 120V
AND 277V
5