O N - D E M A N D R E S I D E N T I A L /
L I G H T C O M M E R C I A L G A S
ON-DEMAND RESIDENTIAL/LIGHT
COMMERCIAL GAS MODELS
GTS-510-NI
GTS-510-PI
Fully modulating, gas fired, tankless
water heater specifically designed for
residential and light commercial
applications. Indoor and outdoor
models available. Capable of
supplying hot water for domestic hot
water systems or heating applications
(local codes dictate proper
compliance). Features HRS35 copper
alloy and a thicker heat exchanger
drum for added durability. Up to four
units can be easily linked without a
multi-unit controller in sytems for
larger applications.
FEATURES
Primary Heat Exchanger is
Contructed of HRS35 Copper
• Stronger than standard copper and
more resilient against erosion
Continuous Maximum Flow
Rates up to 10.0 GPM
Can be used in both
Residential and Light
Commercial Applications
®
ENERGY STAR
Qualified
SAFETY FEATURES
• Built in Freeze Protection
• Manual Reset Hi Limit (Set at 194°F)
• Overheat Cutoff Fuse
• Inlet, Outlet & MixingThermistors
for Constant Temperature Monitoring
• Air Fuel Ratio Rod
• GFI Power Supply Connection
• Flame Sensor
Venting and Combustion
• 4” Category III Stainless Steel
• Vertical or Horizontal Installation
• 50’ Max Length, 5 elbows max (90°
elbows = 5’ equivalent length)
• Power Vent
• Electronic Ignition - No Pilot Light
• 3” Combustion Air Intake (with
optional kit)
Optional Accessories
• Remote Temperature Controller
• Direct Vent Conversion Kit (indoor)
• Complete Line of Stainless
Steel Venting
• Recess Box (outdoor)
• Pipe Cover
• Isolation Valve Kits
• Backflow Preventor
• Concentric Termination Kits
GTS-510-NE
GTS-510-PE
Qualifies for up to $1500 Tax
Credit (must be installed by
December 31, 2010)
Easily Connect up to 4 Units
• With no additional parts or
accessories needed
Low NOx Emissions
Complies with Lead
ANSI Z21.10.3
CSA 4.3
For more information on Residential/Light Commercial Gas On-Demand units, contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
1-877-737-2840 Toll-free USA
www.statewaterheaters.com
Plumbing Law
Warranty
• 12-year limited warranty on heat
exchanger in residential applications
• 5-year limited warranty on heat
exchanger in commercial applications
• 5-year warranty on all parts
SRGSS03510
O N - D E M A N D R E S I D E N T I A L
!
"!
#!
$!
%!
&!
'!
(!
)!
!*! #*! %*! '*! )*! "!*! "#*!
!
#!
%!
'!
)!
"!!
"#!
510 Indoor/Outdoor Pressure Loss
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
0 20 40 60 80 100 120 140
Comparison of Flow Rate vs. Temperature Rise
13-3/4" (350mm)
10" (254mm)
1-3/4" (45mm) 1-3/4" (45mm)
1-3/8" (36mm)
21-3/8" (544mm)
20-1/4" (520mm)
1-7/8" (47mm)
HOT 5-1/4" (133mm)
120V 1-3/8" (36mm)
GAS 4-7/8" (124mm)
COLD 3-1/4" (84mm)
Ø 3-9/8 " (101 mm)
4-3/8" (113mm)
1-5/8" (43mm)
19-3/8" (493mm)
COLD 2-7/8" (71mm)
1" (26mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
120VAC 3-7/8" (99mm)
GAS 5-1/4" (135mm)
13-3/4" (350mm)
10" (254mm)
1-3/4" (45mm)
1-3/4" (45mm)
21-3/8" (544mm)
20-1/4" (520mm)
1-7/8" (47mm)
HOT 5-1/4" (133mm)
120V 1-3/8" (36mm)
GAS 4-7/8" (124mm)
COLD 3-1/4" (84mm)
1-5/8" (43mm)
5" (128mm)
7-7/8" (203mm)
4-3/8" (113mm)
19-3/8" (493mm)
COLD 2-7/8" (71mm)
1" (26mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
120VAC 3-7/8" (99mm)
GAS 5-1/4" (135mm)
L I G H T C O M M E R C I A L G A S
ON-DEMAND RESIDENTIAL/LIGHT COMMERCIAL GAS MODELS
MODEL
NUMBER
GTS-510-NI
GTS-510-PI
GTS-510-NE
GTS-510-PE
GAS CONSUMPTION
INPUT
FUEL
TYPE
MIN.
BTU/H
MAX.
BTU/H
ENERGY
FACTOR
Natural 11,000 199,000 0.83 5.0 10.5 10.0 20.5 13.8 8.5 120 0.77 4” O.D. 3” O.D. 3/4” NPT 45
Propane 11,000 199,000 0.82 8.0 14.0 10.0 20.5 13.8 8.5 120 0.77 4” O.D. 3” O.D. 3/4” NPT 45
Natural 11,000 199,000 0.82 5.0 10.5 10.0 20.5 13.8 8.5 120 0.77 4” O.D. 3” O.D. 3/4” NPT 45
Propane 11,000 199,000 0.82 8.0 14.0 10.0 20.5 13.8 8.5 120 0.77 4” O.D. 3” O.D. 3/4” NPT 45
INLET GAS
DIMENSIONS
PRESSURE
MIN.
MAX.
W.C.
MAX
W.C. HEIGHT WIDTH DEPTH
GPM*
(INCHES)
VOLT AMP FLUE**
All dimensions in inches.
15-150 psi water pressure. 40 psi or above recommended for maximum flow.
*Current numbers based on factory testing, 0.4 GPM required for continuous fire after initial ignition.
**Category III required
Pressure only relief valve requires (Min. 200,000 BTUs. 150 PSI). Min 40 PSI or above recommended for maximum flow.
INTAKE
(OPTIONAL)
HOT/COLD
GAS CONN.
APPROX.
SHIPPING
WEIGHT
(LBS)
CLEARANCES: Top 12”, Bottom 12”, Front 24”, Back 1”, Sides 2”
510 INDOOR DIMENSIONS
Water heater(s) shall be Model _________________ as manufactured by A. O. Smith. The water heater(s) shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s)
will be factory assembled and tested. The heater shall be vented with 4” Stainless steel Category III vent pipe a distance not to exceed 50’ (equivalent) feet terminating vertically as prescribed. Intake air with optional direct
vent kit may be of such material as PVC not to exceed a total of 50’ (equivalent). The heater(s) shall be controlled by onboard solid state printed circuit board monitoring incoming and outgoing temperatures with factory
installed thermistors, sensing and controlling flow rate to set point temperature with control both air and gas mixture inputs to maintain thermal combustion efficiency. Unit also consists of ground fault interrupter, inline
fusing, spark ignition and sensor system, aluminized stainless steel burners, air-fuel ration rod, Hi limit switch, modulating and proportional gas valves, freeze protection sensor and heating block and overhead cut-off fuses.
The water heater(s) shall be CSA listed, exceeds the energy efficiency requirements of ASHRAE 90. 1b-1992 and listed by SCAQMD rule 1146.2 Low NOx.
For more information on Residential/Light Commercial Gas On-Demand units, contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
1-877-737-2840 Toll-free USA
www.statewaterheaters.com
SRGSS03510 © 2010 State Industries, Inc. Printed in U.S.A
For complete information on limited warranties, consult written warranty or contact technical support at 1-877-737-2840.
State Industries, Inc., reserves the right to make product changes or improvements without prior notice.
CLEARANCES: Top 36”, Bottom 12”, Front 24”, Back 1”, Sides 2”
510 OUTDOOR DIMENSIONS
Specification