State GS6 50 YRDS L User Manual

R E S I D E N T I A L
®
S ELECT
S L
DIRECT VENT RESIDENTIAL GAS WATER HEATER S
Durable Brass Tamper-
Resistant Drain Valve
Glasslined Tank
• For long-lasting protection
®
Side-Mounted Taps Designed for Recirculating Systems
Direct Vent Design
• One-pipe, dual channel closed­combustion system draws all make-up air from outside the home, eliminating issues caused by insufficient indoor ventilation. Horizontal air intake and venting on all models up to 80 inches from outisde wall, with no electrical power needed
against corrosion
Push Button Piezo Ignitor
• Simplifies lighting pilots with one-hand spark ignition
Anode Rods
• For added protection against corrosion
Factory-Installed CSA Certified and ASME Rated T&P Relief Valve
For more information on Select®SL contact:
FVIR Compliant Design
Thick, “Environmentally­Friendly” Non-CFC
Diffuser Dip Tube
• Reduces lime and sediment buildup, maximizes hot water output
• Made of PEXAN™, a cross-linked PEX polymer that can withstand long-term exposure to water temperatures up to 400°F
Foam Insulation
• Reduces standby heat loss and improves efficiency
6-Year Limited Tank and Parts Warranty
Green Choice®“Eco­Friendly” Gas Burner
• Patented design reduces NOx emissions by up to 33% compared to standard burners
Code Compliance - All models meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992 and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. Also complies with the current editions of the B.O.C.A. National Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards.
State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015
1-800-365-0024 Toll-free USA www.statewaterheaters.com
SRGSS04011
42°
47°
25-1/4 FOR
40 & 50-GALLON
29-1/2 FOR 75-GALLON
69°
55°
TOP
TELNI
ARD NI
P&T
TELTUO
E
F
B
A
D
FRONT
MAX VENT
80
C
EXTERIOR
WALL
MIN VENT
17
SIDE TAPS
H
G
6“ DIA. ON THE 40 & 50-GALLON MODELS
7” DIA. ON THE 75-GALLON MODELS
75-GALLON VENT
TERMINATION
CAP IS NOT
INTERCHANGEABLE
WITH THE VENT
CAP ON THE
40 & 50-GALLON
MODELS
R E S I D E N T I A L
SELECT®SL – DIRECT VENT RESIDENTIAL GAS WATER HEATERS
MODEL
NUMBER
GALLON
CAPACITY
ENERGY
FACTOR
(EF)
BTU INPUT PER HOUR
NATURAL
RECOVERY
90°F RISE
BTU OUTPUT
PER HOUR
NATURAL
FIRST HOUR
RATING
DIMENSIONS IN INCHES
*A B C D E F G H
GS6 40 YBDS L 40 0.62 38,000 41 30,780 73 68 54-3/4 22-1/4 16 12-1/4 45-1/4 16-1/2 41-3/4 167
GS6 50 YRDS L 50 0.59
GS6 75 YRDS L 75 0.59
Recoveries are rounded to nearest gallon Water Connections - 3/4” on all models Dual-channel system has 3” vent pipe inside 6” air intake pipe for the 40 & 50-gallon models. The 75-gallon model uses a 4”x7” Co-Axial Pipe. *A Dimension is to center line of flue (recommended vent height) When ordering propane, change “YY” to All models have 2” foam cavity All 75-gallon water connections are 12” on center
50,000 55 40,500 88 76 64-3/4 22-1/4 16-1/4 12-1/2 55-1/2 16-1/2 53-3/4 187
55,000 60 44,550 131 76 65-3/4 26-1/4 16-1/4 12-1/2 55-1/2 17-1/4 54 310
“HH” in the model number (Example: GS6 40 HHBDS L)
Optional Circulating Loop Fittings Package, Part No. 9002604005
Circulating Loop Fittings Package includes assembled di-electric unions and full port shut-off valves. A standard hose-connect drain valve is included for field installation. Specially designed for use on side tap recirculating water heaters. Kit must be ordered through Service Parts Department by calling 1-800-821-2017.
Important! Vent Installation and Termination Requirements
• Maximum horizontal vent distance is 80” to outside of exterior wall
• Minimum horizontal vent distance is 17” to outside of exterior wall
• Vent pipes may be trimmed (cut) for short vent installations
• For vent installation less than 30” the vent restrictor is required. Place restrictor over the flue outlet on heater before installing the outlet vent pipe to the heater
• Recommended installation height for the heater and vent pipe should be 68” for 40-gallon models and 76” for the 50 and 75­gallon models (vent height)
• Offset Vent Arrangement
1. When replacing an existing direct vent model, the new vent pipe
may drop from the minimum vent height as much as 7-1/4” to exit through the existing vent opening in the exterior wall
2. Vent may have one horizontal 90° degree turn before exiting
through exterior wall (Do not combine both offset vent arrangements in one installation) (See examples in the installation manual)
• High Rise Vent Arrangement
3. When vent termination is more than 80” above the base of the
heater. The horizontal vent runs must be a minimum of 22” from the center of the heater to the outside exterior wall surface. (See example in the installation manual)
• Vent termination clearance hole through the exterior wall should be approximately 7” diameter
• Snow accululation and drifting should be considered when locating the termination
• An optional wire grill vent cap protector is available through the parts department. Request part number 9006627005.
• See the installation manual for complete installation and venting requirements.
APPROX.
SHIPPING
WEIGHT
(LBS)
For complete information on limited warranties, consult written warranty or contact technical support at 1-800-365-0024.
For more information on Select®SL contact:
State Water Heaters 500 Tennessee Waltz Parkway
State Industries, Inc., reserves the right to make product changes or improvements without prior notice.
Ashland City, TN 37015
1-800-365-0024 Toll-free USA www.statewaterheaters.com
SRGSS04011 © 2011 State Industries, Inc. Printed in U.S.A