#R172323, #R172324 &
#R172288
CHECK VALVE
INSTALLATION INSTRUCTIONS
FOR #300-29X CHLORINATOR: USE #R172324 ½" CHECK VALVE
INSTEAD OF #R172323 ¼" CHECK VALVE AS SHOWN
NOTE:
MAKE SURE ALL PUMPS AND TIMER SWITCHES ARE IN THE OFF POSITION.
#R172323* ¼" CHECK VALVE &
#R172324* ½" CHECK VALVE INSTALLATION:
1. Cut Chlorinator inlet line at desired location.
2. Slide compression nut over one end of line.Make sure arrow on check valve is pointing
toward Chlorinator, insert barbed end of check valve into line and tighten the nut finger
tight. Repeat procedure for other end of check valve.
#R172288 1½"-2" CHECK VALVE INSTALLATION:
1. Cut piping at required location for your situation (refer to drawings).
2. Making sure arrow on check valve is pointing away from equipment and in the
direction of water flow to the pool/spa, glue in check valve using PVC solvent cement.
1½" pipe will glue directly in valve, 2" pipe requires two 2" slip x slip couplings
WITH HEATER
Suction from pool/spa
**Note: For greater flow rate, inlet line
may be installed between filter and pump.
NOTE: If heaters are used, a FIREMAN’S SWITCH or
equivalent must be installed to prevent possible
damage and improper operation of CHECK VALVE
and other equipment subject to heat damage.
WITHOUT HEATER
Suction from pool/spa
Sanford, NC
Moorpark, CA R24050-0402
Chlorinator
outlet line
**Chlorinator
inlet line
#R172323* ¼" Check Valve or
#R172324* ½" Check Valve
Chlorinator
Heater
Pump
#R172288
1½"-2" Check Valve
Return line to
pool/spa
Filter
Chlorinator
outlet line
**Chlorinator
inlet line
#R172323* ¼" Check Valve or
#R172324* ½" Check Valve
Chlorinator
Pump
Return line to
pool/spa
#R172288
1½"-2" Check Valve
Filter