The following instructions detail the process for installing a Marley
HP7000 Fan on a Marley Geareducer® with a tapered fan (output)
shaft and bolted fan hub retention. Installation on other gear reduction units may be different. Contact your Marley sales representative
for supplemental instructions if required.
1–Remove the retention plate and hardware from the top of the
Geareducer shaft. Thoroughly clean the fan shaft, fan shaft key,
and the fan hub center bore to remove any debris and/or protective
coatings. After cleaning, apply a coat of anti-seize compound to the
top 5″ (130mm) of the fan shaft.
2–Prior to hub installation, fully seat the key in the fan shaft keyway.
The key is a tight t across the width and must never be altered.
3–Raise the fan hub above the fan shaft for installation. Slowly lower
the hub onto the shaft with the keyways properly aligned. Make certain the key does not slide down during installation. Stake the key
in the keyway with a center punch if necessary.
The fan shaft key should be approximately centered in the engaged
portion of the hub when engaged on the shaft. Verify the center hub
is fully seated by visual inspection.
4–The hub retention plate will sit on top of the spool. Discard the
retention bolts that come with the Geareducer. New retention bolts
are provided with the hub cover hardware kit. Torque bolts to 50 ft·lbƒ
(68 N·m).
Figure 2
3
Note
BLADE SIZE
MOMENT WEIGHT CLASS
SERIAL NUMBER
For Additional Information Refer to HP7000 Manual
SPX Cooling Technologies
Overland Park, KS USA
913 664 7400
www.spxcooling.com
HP7000 Fan
Fan Blade Installation
Marley HP7000 fan blades are manufactured to equal moment weight
and blade clamps to equal static weight. The blades and clamps can
be installed in any position without affecting fan balance.
At the end of the blade shank on a nameplate is inscribed a letter code (i.e. “A” or “B” etc.). When installing or replacing blades
use only blades with the same letter code.
Figure 3–Blade Nameplate
1–Lubricate the C\v″ bolt and C\v″ hex-nut threads with thread lubricant.
Set the hardware aside.
Figure 4
4
2–Remove one set of blade clamps from the hub assembly. Blade
BLADE CLAMP
FLAT WASHER
MACHINE BOLT
FAN BLADE
HUB PLATE
HUB PLATE
FLAT WASHER
LOCKING HEX NUT OR
HEX NUT AND LOCK WASHER
clamps are installed on the hub assembly at the factory with spacers
for shipping purposes. Remove and discard the spacers. Position
the blade clamps around the shank of a blade with the machinedface end of the blade clamp against the blade safety shoulder. See
Figure 5. Large nylon cable ties can be used to hold blade clamps
on the blade during installation providing easier assembly.
3–Insert the blade with blade clamps around the shank and with
Figure 5
the concave blade side (TOP) on the discharge side between
the hub assembly plates as shown in Figure 4. Vertically align
the two bolt holes in the clamps and plates. Install two lubricated
C\v″ bolts, four C\v″ at washers, (two C\v″ lock washers if hardware ma-
terial is monel), and two C\v″ hex nuts, engaging the nuts only three
to four threads as shown in Figure 5. Do not tighten the hardware
until all the blades have been installed. The blade must be free to
rotate in the clamp for pitch adjustment.
4–Repeat until all blades, clamps, and hardware have been installed
in the hub assembly.
5
Note
BEVEL
PROTRACTOR
STRAIGHT
EDGE
BLADE
2"
TIP
PITCH ANGLE
Figure 6
Adjusting Fan Blade Pitch
The trial pitch is the calculated setting for design conditions
(water rate , heat load, air density, and brake horsepower). The trial
pitch is provided by SPX Cooling Technologies (see page 2).
Section
1–Select a position on the fan circumference and rotate each blade
to this common location when setting or checking blade pitch. Support the blade tip to maintain a common rotation plane while setting
the fan pitch. The pitch is set within 2
placing a bevel protractor on top of a parallel sided straight edge
that extends across blade width as shown in Figure 6.
2–Pull the blade outward so the safety shoulder is in contact
with the blade clamp, then set the pitch. See Figure 5. Blades
should be within ± 1/4° of the desired pitch angle. After the desired setting is obtained, progressively tighten the C\v″ hex nuts to
120 ft·lb
loosen the hex nuts and reset the pitch as necessary until the proper
pitch angle is obtained with the C\v″ hex nuts at 120 ft·lbƒ (163 N·m)
torque.
3–Repeat step 2 for all blades.
4–Check the vertical blade-tip track variation. The allowable vertical
variation from a reference plane is ±1″ (25mm). If a blade’s tip track
is out of tolerance, loosen the C\v″ hardware and change the blade
tip support location higher or lower as required to adjust the tip track.
Recheck blade pitch angle.
(163 N·m) torque. Recheck the pitch angle. If required,
ƒ
″ (51mm) of the blade tip by
6
Figure 7
141
102
143
142
300
145
142
146
144
142
Hub Cover Installation
Install the hub cover as shown in Figure 1 and Figure 7. Tighten all
hex nuts to 15 ft·lbƒ (20 N·m) torque.
Fan Maintenance
Preventative maintenance will prolong useful life and assure con-
tinued trouble-free operation. After the rst week and subsequently
at six month intervals:
• Torque all hardware to specications referenced in this manual.
• Visually inspect the fan for airborne debris damage, contact with
fan cylinder segments, and corrosive attack. Correct any situations
determined detrimental to fan operation.
• Remove any accumulated scale or dirt.
• Clear blade drain holes.
Service
Proper identication of your fan is necessary to insure you receive
correct replacement parts. The Marley cooling tower serial number
can be used to determine the fan and any components installed and
maintained as original equipment on a Marley cooling tower. The fan
diameter and moment weight class from the blade nameplate (see
Figure 3) is required to identify blades for replacement. The fan hub
➠
7
assembly identication number (see Figure 1) is required to identify
/
7401 W 129 Street // Overland Park, KS USA 66213 // +1 913 664 7400 // spxcooling@ct.spx.com // www.spxcooling.com
/
In the interest of technological progress, all products are subject to design and/or material change without notice
a replacement hub assembly or repair components. Please provide
the Marley sales representative the necessary information when
ordering replacement fans or components.
Blades can be replaced without rebalancing the entire fan.
If rebalancing is desired, contact the Marley sales representative in
your area.
Motor Load
The corrected horsepower should be close to but not exceed the
Actual volts and amperage must be obtained with the fan running
and the specied rate of water owing over the tower after the motor
and Geareducer have reached operating temperature (approximately
30 minutes of operation).
Measurements taken on motors operating with Variable Frequency Drive controls may read up to 15% high from errors in
measuring the approximated sine wave. Instruments capable
of measuring a squared off wave form accurately should be
used for measuring power in this situation.
Do not exceed 30 sec/hour total motor starting time as motor
may overheat.