INSTALLATION AND OPERATION INSTRUCTIONS
OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater.
INFRARED RADIANT TUBE HEATER
Single Stage Pull Through System (Negative Pressure)
Models:
ETS SERIES: (40, 50, 60, 75, 80, 90, 100, 110, 120, 125, 130, 140, 150, 160, 175, 180, 200, 225, 250) – N5/L5
ETU SERIES: (40, 50, 60, 75, 80, 90, 100, 110, 120, 125, 130, 140, 150, 160, 175, 180, 200, 225, 250) – N5/L5
!INSTALLER: This manual is the property of the owner. Please present this manual to the owner when you leave the job site.
▲WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment.
IF YOU SMELL GAS: |
FOR YOUR SAFETY |
|
|
!DO NOT try to light any appliance.
!DO NOT touch any electrical switch; DO NOT use any telephone in your building.
!IMMEDIATELY call your gas supplier from a neighbor's telephone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
DO NOT store oruse gasoline or other flammable vapors and liquids in the vicinity of this orany other appliance.
!IMPORTANT: SAVE THIS MANUAL FOR FUTURE REFERENCE.
SPACE-RAY
Post Office Box 36485 (28236) • 305 Doggett Street (28203) • Charlotte, North Carolina Phone (704) 372-6391 • Fax (704) 332-5843 • www.spaceray.com • email: info@spaceray.com
Form 43343300
May 2013
TABLE OF CONTENTS
SECTION |
DESCRIPTION |
PAGE |
1.0) |
Safety................................................................................................................................................... |
2 |
2.0) |
Installer Responsibility...................................................................................................................... |
2 |
3.0) |
General Information........................................................................................................................... |
2 |
4.0) |
Minimum Clearances to Combustibles........................................................................................... |
4 |
5.0) |
Specifications...................................................................................................................................... |
5 |
6.0) |
Packing List......................................................................................................................................... |
5 |
6.1) |
Accessory Packages........................................................................................................................ |
11 |
7.0) |
Typical Layouts................................................................................................................................. |
13 |
7.1) |
Typical Assembly Layout – ETS 180-250 Series......................................................................... |
14 |
7.2) |
Typical Assembly Layout – ETU 180-250 Series......................................................................... |
15 |
8.0) |
Dimensions – ETS Series................................................................................................................ |
16 |
8.1) |
Dimensions – ETU Series................................................................................................................ |
17 |
8.2) |
Heater Assembly / Joining of Tube Sections............................................................................... |
18 |
9.0) |
Typical Suspension Methods.......................................................................................................... |
20 |
10.0) |
Assembly of Tube Sections............................................................................................................. |
21 |
10.1) |
Assembly of Extension Sections.................................................................................................... |
22 |
10.2) |
Adding Reflectors............................................................................................................................. |
23 |
10.3) |
Joining of Flanged Tube Sections – ETS/ETU 225-250 Series.................................................. |
24 |
10.4) |
Adding Optional 90º Elbow (ETS Only).......................................................................................... |
25 |
10.5) |
Adding Optional Corner Reflector (ETS Only)............................................................................... |
25 |
10.6) |
Adding 180º U-Bend (ETU Only)...................................................................................................... |
26 |
10.7) |
Adding Optional U-Bend Reflector (ETU Only).............................................................................. |
26 |
11.0) |
Attaching Control Box Assembly.................................................................................................... |
27 |
12.0) |
Attaching Draft Inducer Assembly................................................................................................. |
28 |
13.0) |
Multiple Hanging & Draft Inducer Positions ................................................................................ |
29 |
14.0) |
Gas Connections and Regulations................................................................................................. |
30 |
15.0) |
Instructions for Pressure Test Gauge Connection....................................................................... |
32 |
16.0) |
Electrical Connections..................................................................................................................... |
33 |
17.0) |
Venting............................................................................................................................................... |
37 |
18.0) |
Air for Combustion........................................................................................................................... |
41 |
18.1) |
Direct Outside Air for Combustion................................................................................................. |
41 |
19.0) |
Lighting and Shutdown Instructions.............................................................................................. |
43 |
20.0) |
Sequence of Operation.................................................................................................................... |
43 |
21.0) |
Control Component Location.......................................................................................................... |
44 |
22.0) |
Cleaning and Annual Maintenance............................................................................................... |
45 |
23.0) |
Troubleshooting Guide..................................................................................................................... |
46 |
24.0) |
Replacing Parts................................................................................................................................ |
49 |
24.1) |
Removing Spark Electrode............................................................................................................. |
49 |
24.2) |
Removing Main Burner and Gas Valve......................................................................................... |
50 |
24.3) |
Air Switch Pressure Check.............................................................................................................. |
51 |
24.4) |
Ignition System Checks................................................................................................................... |
51 |
24.5) |
Motor and Blower Wheel Check..................................................................................................... |
52 |
25.0) |
Installation Data............................................................................................................................... |
52 |
26.0) |
Replacement Parts Guide............................................................................................................... |
53 |
27.0) |
Warnings Card.................................................................................................................................. |
59 |
This heater complies with ANSI Z83.20 (current standard) and CSA 2.34. Copies of the National Fuel Gas Code (ANSI Z223.1-latest edition) are available from the CSA at 8501 East Pleasant Valley Road, Cleveland, Ohio 44131 or 55 Scarsdale Road, Don Mills, Ontario M3B 2R3. All NFPA codes are available from the National Fire Protection Association, Batterymarch Park, Quincy, Massachusetts 02269.
Form 43343300 |
|
May 2013 |
-1- |
1.0) SAFETY
This heater is a self-contained infrared radiant tube heater. Safety information required during installation and operation of this heater is provided in this manual and the labels on the product. The installation, service and maintenance of this heater must be performed by a contractor qualified in the installation and service of gas fired heating equipment.
All personnel in contact with the heater must read and understand all safety information, instructions and labels before operation. The following symbols will be used in this manual to indicate important safety information.
Warning instructions must be followed to prevent or avoid hazards which may cause serious injury, property damage or death.
Caution instructions must be followed to prevent incorrect operation or installation of the heater which may cause minor injury or property damage.
2.0) INSTALLER RESPONSIBILITY
The installer is responsible for the following:
•The heater and venting, as well as electrical and gas supplies must be installed in accordance with these installation instructions and any applicable codes and regulations.
•Every heater shall be located with respect to building construction and other equipment so as to permit access to the heater.
•Each installer must follow the clearances to combustible materials for the heaters.
•Install the heater so that the supports and hangers are correctly spaced in accordance with these instructions. The heater must be supported by materials having a working load limit of at least 115lbs.
•Supply the owner with a copy of these Installation and Operation Instructions.
•Where unvented heaters are used, gravity or mechanical means shall be provided to supply and exhaust at least 4 CFM per 1,000 Btu/hr input of installed heaters.
•Never use the heater as a support for a ladder or other access equipment. Do not hang anything from the heater.
•Supply all installation materials necessary that are not included with the heater.
•Check the nameplate to make sure that the burner is correct for the gas type in the building and the installation altitude.
3.0) GENERAL INFORMATION
This heater is a self-contained infrared radiant tube heater for use in locations where flammable gases or vapors are not generally present (as defined by OSHA acceptable limits) and is intended for the heating of nonresidential spaces.
INSTALLATION REQUIREMENTS
The installation must conform to local building codes or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA54 or the Natural Gas and Propane Installation Code CSA B149.1. Heaters shall be installed by a licensed contractor or licensed installer. Clearances to combustibles as outlined in this manual should always be observed. In areas used for storage of combustible materials where they may be stacked below the heater, NFPA54 requires that the installer must post signs that will “specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles.”
The higher capacity ETS/ ETU 180–250 models generate intense radiant heat. Therefore, the minimum recommended mounting height is 18 ft. above floor level for the ETS/ ETU 180-200 models and 20 ft. above floor level for the ETS/ ETU 225-250 models. Heaters may be mounted at various heights and angles depending on the application. If you have any questions, pleaseconsult your local Space-Ray representative.
Every heater shall be located with respect to building construction and other equipment so as to permit access to the heater. Each installer shall use quality installation practices when locating the heater and must give consideration to clearances to combustible materials, vehicles parked below, lights, overhead doors, storage areas with stacked materials, sprinkler heads, gas and electrical lines and any other possible obstructions or hazards. Consideration also must be given to service accessibility.
|
Form 43343300 |
-2- |
May 2013 |
The heater, when installed in aircraft hangars and public garages, must be installed in accordance with ANSI/NFPA 409-latest edition (Standard for Aircraft Hangars), ANSI/NFPA 88a-latest edition (Standard for Parking Structures), and ANSI/NFPA 88b-latest edition (Standard for Repair Garages) with the following clearances:
a.At least 10 feet above the upper surfaces of wings or engine enclosures of the highest aircraft that may be housed in the hangar and at least 8 feet above the floor in shops, offices, and other sections of hangars communicating with aircraft storage or service areas.
b.At least 8 feet above the floor in public garages. ▲WARNING: Minimum clearances marked on the heater must be maintained from vehicles parked below the heater.
(FOR CANADA ONLY)
a.Installation of this appliance is to be in accordance with latest edition of CSA B149.1 (Natural Gas and Propane Installation Code).
b.For installation in public garages or aircraft hangars, the minimum clearances from the bottom of the infrared heater to the upper surface of the highest aircraft or vehicle shall be 50 percent greater than the certified minimum clearance, but the clearance shall not be less than 8 feet.
Although these heaters may be used in many applications other than space heating (e.g., process heating), Space-Ray will not recognize the warranty for any use other than space heating.
For indoor installation only. Not for use in residential dwellings.
This heater is for Indoor Installation and Covered Patio Installation only and can be used in either Vented or Unvented mode. The term Unvented actually means Indirect Vented. While the products of combustion are expelled into the building, national codes require ventilation in the building to dilute these products of combustion. This ventilation may be provided by gravity or mechanical means.
This heater is not an explosion proof heater. Where the possibility of exposure to volatile and low flash point materials exists, it could result in property damage or death. This heater must not be installed in a spray booth where the heater can operate during the spraying process. Consult your local fire marshal or insurance company.
ETS Series Only: Since straight tube heaters are always hotter at the control end than at the flue terminal end, always observe the minimum recommended mounting heights shown on the specification sheets in Section 5.0) of this manual. Use U-tube configuration instead of straight tubes for spot or area heating (e.g., where a single heater is utilized for space heating).
WARM
HOT
WARM
HOT
WARM |
WARM |
High Altitude:
Appliances are supplied as standard for altitudes of O to 2,000 feet (0-610 m). High-altitude ratings are obtained by a change in the orifice size. When ordered for high altitude installations, burners are supplied by the factory ready for high altitude installation. Check the nameplate for altitude before proceeding with the installation. In Canada the adjustment for altitude is made in accordance with Standard CGA 2.17, Gas-Fired Appliances for Use at High Altitudes.
Form 43343300 |
|
May 2013 |
-3- |
4.0) MINIMUM CLEARANCES TO COMBUSTIBLES
Combustible material must be located outside the clearance dimensions listed.
Failure to do so may result in death, serious injury or property damage.
Install the warnings card (ordered separately) and complete the blank spaces using the clearances from combustibles table below. See Section 27 for a printed copy of the warnings card.
Minimum clearances to combustibles shall be measured from the outer surfaces as shown in the following diagram:
End |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
End |
|||
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Ceiling |
||||||
|
|
|
* Ceiling |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Front |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rear |
Side |
|
|
|
Side |
|
|
|
||||||||||||
|
|
|
|
|
Below |
|
|
|
|
|
|
|
|
|
|
Below |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Horizontal |
|
45° Angle (Maximum) |
MINIMUM CLEARANCES TO COMBUSTIBLES
|
|
|
|
|
Angle Mounted at |
|
|
|
Mounted Horizontally |
|
45º |
||
Model No. |
Sides |
Ceiling* |
Below |
Ends |
45º Front |
45º Rear |
ETS 40, 50 |
24” |
6” |
40” |
15” |
40” |
12” |
ETS 60, 75 |
24” |
6” |
60” |
15” |
52” |
12” |
ETS/ETU 80, 90 |
26” |
6” |
66” |
15” |
52” |
12” |
ETS/ETU 100 |
28” |
6” |
76” ** |
15” |
60” |
12” |
ETS/ETU 110, 120, 125, 130 |
32” |
6” |
82” ** |
20” |
66” |
12” |
ETS/ETU 140, 150 |
36” |
6” |
87” ** |
20” |
70” |
12” |
ETS/ETU 160, 175 |
42” |
6” |
93” ** |
20” |
77” |
12” |
ETS/ETU 180, 200 |
44” |
6” |
106” ** |
20” |
84” |
12” |
ETS/ETU 225, 250 |
56” |
6” |
112” ** |
20” |
90” |
18” |
* When used indirect vented, minimum clearance for CEILING must be: 12” for ETS/ETU 40-75 and 18” for ETS/ETU 80-250. If optional corner and U-bend reflectors are not used, the clearance must be 18”.
** Maximum clearance below reduces by 50% once you are 25 ft. downstream from the burner box.
▲WARNING: Certain materials or objects, when stored under the heater, will be subjected to radiant heat and could be seriously damaged. Observe the Minimum Clearances to Combustibles listed in the manual and on the heater at all times.
NOTE:
1.The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90ºF above ambient temperature. Clearances to combustibles are posted on the control box. In areas used for storage of combustible materials where they may be stacked below the heater, NFPA54 requires that the installer must post signs that will “specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles.” Space-Ray recommends posting these signs adjacent to the heater thermostat or other suitablelocationthat will provide enhanced visibility.
2.The stated clearance to combustibles represents a surface temperature of 90 ºF (32 ºC) above room temperature. Building materials with a low heat tolerance (such as plastics, vinyle siding, canvas, tri-ply, etc.) may be subject to degradation at lower temperatures. It is the installer’s responsibility to assure that adjacent materials areprotected fromdegradation.
|
Form 43343300 |
-4- |
May 2013 |
|
5.0) |
SPECIFICATIONS |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Minimum * |
||
|
|
|
|
|
|
Orifice Size |
|
Mounting Height |
|||
|
|
Btu/hr |
Flue Restrictor Plate |
|
|
|
|
@ |
@ |
|
|
Model No. |
Input |
I.D. & Part # |
Natural Gas |
Propane Gas |
Horizontal |
45º Angle |
|||||
ETS/ETU 40 |
40,000 |
1” |
#42741040 |
#31 |
(0.120) |
#49 |
(0.073) |
10 ft. |
9 ft. |
||
ETS/ETU 50 |
50,000 |
1-1/8” |
#42741030 |
3.3mm |
(0.130) |
#46 |
(0.081) |
11 ft. |
10 ft. |
||
ETS/ETU 60 |
60,000 |
1-7/32” |
#42741020 |
#27 |
(0.144) |
#43 |
(0.089) |
12 ft. |
11 ft. |
||
ETS/ETU 75 |
75,000 |
1-7/16” |
#42741010 |
#20 |
(0.161) |
#39 |
(0.099) |
13 ft. |
12 ft. |
||
ETS/ETU 80 |
80,000 |
1-1/2” |
#42741050 |
#19 |
(0.166) |
#38 |
(0.102) |
13 ft. |
12 ft. |
||
ETS/ETU 90 |
90,000 |
1-1/2” |
#42741050 |
#16 |
(0.177) |
#36 |
(0.106) |
13 ft. |
12 ft. |
||
ETS/ETU 100 |
100,000 |
1-5/8” |
#42741060 |
#14 |
(0.182) |
#33 |
(0.113) |
13 ft. |
12 ft. |
||
|
|
|
|
|
|
|
|
|
|
||
ETS/ETU 110 |
110,000 |
1-3/4” |
#42741070 |
#10 |
(0.194) |
#31 |
(0.120) |
14 ft. |
13 ft. |
||
|
|
|
|
|
|
|
|
|
|
||
ETS/ETU 120 |
120,000 |
1-3/4” |
#42741070 |
13/64 |
(0.203) |
1/8 |
(0.125) |
14 ft. |
13 ft. |
||
|
|
|
|
|
|
|
|
|
|
||
ETS/ETU 125 |
125,000 |
1-7/8” |
#42741080 |
#5 |
(0.206) |
#30 |
(0.129) |
14 ft. |
13 ft. |
||
ETS/ETU 130 |
130,000 |
1-7/8” |
#42741080 |
#4 |
(0.209) |
3.3mm |
(0.130) |
14 ft. |
13 ft. |
||
|
|
|
|
|
|
|
|
|
|
||
ETS/ETU 140 |
140,000 |
2-1/32” |
#42741090 |
5.5mm |
(0.216) |
#29 |
(0.136) |
15 ft. |
14 ft. |
||
ETS/ETU 150 |
150,000 |
2-1/32” |
#42741090 |
5.7mm |
(0.224) |
#28 |
(0.140) |
15 ft. |
14 ft. |
||
|
|
|
|
|
|
|
|
|
|
||
ETS/ETU 160 |
160,000 |
2-1/4” |
#42741100 |
5.8mm |
(0.228) |
#27 |
(0.144) |
15 ft. |
14 ft. |
||
|
|
|
|
|
|
|
|
|
|
||
ETS/ETU 175 |
175,000 |
2-1/4” |
#42741100 |
“C” |
(0.242) |
3.8mm |
(0.150) |
15 ft. |
14 ft. |
||
ETS/ETU 180 |
180,000 |
2-1/4” |
#42741100 |
“C” |
(0.242) |
#24 |
(0.152) |
18 ft. |
17 ft. |
||
ETS/ETU 200 |
200,000 |
2-3/8” |
#42741130 |
“F” |
(0.257) |
#21 |
(0.159) |
18 ft. |
17 ft. |
||
ETS/ETU 225 |
225,000 |
2-1/2” |
#42741140 |
6.9mm |
(0.272) |
#18 |
(0.170) |
20 ft. |
19 ft. |
||
ETS/ETU 250 |
250,000 |
2-3/4” |
#42741150 |
“K” |
(0.281) |
4.5mm |
(0.177) |
20 ft. |
19 ft. |
* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform energy distribution for complete building heating applications. Consult your Space-Ray representative for the particulars of your installation requirements.
Type |
Gas Pipe |
Tube |
Flue |
Fresh Air |
Electrical |
Current |
Gas |
Connection1 |
Diameter |
Connection2 |
Connection |
Supply |
Rating |
Natural |
½” MPT |
|
|
|
120 Volt, 60Hz, |
|
or Propane |
(Male) |
4” |
4” Round |
6” Round |
1 Phase |
2.6 Amp |
1 ETS/ETU 225 and 250 require a minimum 3/4” nominal ID flexible gas connector.
2 ETS/ETU 180-250: 6” round. See Section 17.0) for vent sizes and limitations
Fuse Rating: |
Ignition System (direct spark): |
|
In-line: 2 Amp 250V |
30 second pre-purge period |
|
(for 24V Circuit) |
||
|
||
|
|
|
6.0) |
PACKING LIST |
|
|
|
|
|
A. ETS/ETU 40-250 Control/Draft Inducer Package |
|
||
|
|
Part Description |
QTY |
|
|
Control Box Assembly .............................................................................................................................. |
1 |
|
|
Draft Inducer & Junction Box Assembly ................................................................................................ |
1 |
|
|
Flue Restrictor Plate (See Section 5.0) for plate I.D. and part no.) ................................................... |
1 |
|
|
4” x 6” Starting Collar1 (#42892009) Supplied with ETS/ETU 180-250........................................ |
1 |
|
|
Control Fastener Kit (#42907110) ....................................................................................................... |
1 |
|
|
Containing: #8-32 Screws & Nuts (#02166010 & #02127030) .......................................... |
2 |
|
|
¼ - 20 Locknuts (#02167010) .............................................................................. |
6 |
|
|
Tube Flange Gasket (#42921000) ........................................................................ |
2 |
|
|
Draft Inducer Flange (#44015251) ...................................................................................................... |
1 |
|
|
Installation & Operation Instructions (#43343300) .......................................................................... |
1 |
|
|
Gas connector, 5/8” OD x 36” (#30302360) 2 ................................................................................... |
1 |
1 4-inch Starting Collar (#40504020) supplied with ETS/ETU 40-175 models. |
|
||
2 ETS/ETU 225 and 250 models using Gas Connector, 1” OD x 36” (#30302361) |
|
||
Form 43343300 |
|
||
May 2013 |
-5- |
|
CONTROL/DRAFT INDUCER PACKAGE NUMBERS
|
NATURAL GAS |
|
|
|
PROPANE GAS |
|
||
MODEL NO. |
PART NO. |
MODEL NO. |
PART NO. |
|
MODEL NO. |
PART NO. |
MODEL NO. |
PART NO. |
ETS/U 40-N5............ |
#43339010 |
ETS/U 130-N5.......... |
#43340130 |
|
ETS/U 40-L5............ |
#43339020 |
ETS/U 130-L5.......... |
#43340140 |
ETS/U 50-N5............ |
#43339030 |
ETS/U 140-N5.......... |
#43340150 |
|
ETS/U 50-L5............ |
#43339040 |
ETS/U 140-L5.......... |
#43340160 |
ETS/U 60-N5............ |
#43339050 |
ETS/U 150-N5.......... |
#43340170 |
|
ETS/U 60-L5............ |
#43339060 |
ETS/U 150-L5.......... |
#43340180 |
ETS/U 75-N5............ |
#43339070 |
ETS/U 160-N5.......... |
#43340190 |
|
ETS/U 75-L5............ |
#43339080 |
ETS/U 160-L5.......... |
#43340200 |
ETS/U 80-N5............ |
#43340010 |
ETS/U 175-N5.......... |
#43340210 |
|
ETS/U 80-L5............ |
#43340020 |
ETS/U 175-L5.......... |
#43340220 |
ETS/U 90-N5............ |
#43340030 |
ETS/U 180-N5.......... |
#43340230 |
|
ETS/U 90-L5............ |
#43340040 |
ETS/U 180-L5.......... |
#43340240 |
ETS/U 100-N5.......... |
#43340050 |
ETS/U 200-N5.......... |
#43340250 |
|
ETS/U 100-L5.......... |
#43340060 |
ETS/U 200-L5.......... |
#43340260 |
ETS/U 110-N5.......... |
#43340070 |
ETS/U 225-N5.......... |
#43340270 |
|
ETS/U 110-L5.......... |
#43340080 |
ETS/U 225-L5.......... |
#43340280 |
ETS/U 120-N5.......... |
#43340090 |
ETS/U 250-N5.......... |
#43340290 |
|
ETS/U 120-L5.......... |
#43340100 |
ETS/U 250-L5.......... |
#43340300 |
ETS/U 125-N5.......... |
#43340110 |
|
|
|
ETS/U 125-L5.......... |
#43340120 |
|
|
|
|
|
|
|
|
|
|
|
B.ETS 40-175 Body Package Descriptions
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
|
15 Ft. |
20 Ft. |
30 Ft. |
40 Ft. |
50 Ft. |
|
System Lengths |
System |
System |
System |
System |
System |
|
|
15 Ft. Pkg. |
20 Ft. Pkg. |
30 Ft. Pkg. |
40 Ft. Pkg. |
50 Ft. Pkg. |
ETS 40-175 Body Packages – Aluminized/Hot Rolled |
44134000 |
44135000 |
44136000 |
44137000 |
44138000 |
|
Part # |
Each Body Package Includes: |
Qty. |
Qty. |
Qty. |
Qty. |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
1 |
1 |
1 |
1 |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
- |
1 |
2 |
3 |
4 |
41932051 |
5 Ft. Tube less Flanges (Hot Rolled) |
1 |
- |
- |
- |
- |
43319100 |
Reflector, 9’ 11½” |
1 |
2 |
3 |
4 |
5 |
43319050 |
Reflector, 4’ 11½” |
1 |
- |
- |
- |
- |
30462980 |
Tube Coupling |
1 |
1 |
2 |
3 |
4 |
43318000 |
Tube Hanger/Support Bracket, 13” |
2 |
2 |
3 |
4 |
5 |
43980010 |
Wire Hanger |
2 |
2 |
3 |
4 |
5 |
|
|
|
|
|
|
|
Body Fastener Kit (included in body packages) |
42907190 |
42907190 |
42907200 |
42907210 |
42907220 |
|
42873000 |
U-Bolt |
2 |
2 |
3 |
4 |
5 |
02127110 |
Hex Nut, 5/16-18 |
5 |
5 |
6 |
8 |
10 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
8 |
8 |
10 |
14 |
18 |
C.ETS 180-200 Body Package Descriptions
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
System Lengths |
50 Ft. System |
|
|
50 Ft. Pkg. |
ETS 180-200 Body Packages – Aluminized/Hot Rolled |
44138020 |
|
Part # |
Each Body Package Includes: |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
42932100 |
10 Ft. Tube less Flanges (Aluminized) |
1 |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
3 |
43319100 |
Reflector, 9’ 11½” |
5 |
30462980 |
Tube Coupling |
4 |
43318000 |
Tube Hanger/Support Bracket, 13” |
5 |
43980010 |
Wire Hanger |
5 |
|
|
|
Body Fastener Kit (included in body packages) |
42907210 |
|
42873000 |
U-Bolt |
5 |
02127110 |
Hex Nut, 5/16-18 |
10 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
18 |
60 Ft. System
40 Ft. Pkg. 20 Ft. Pkg.
44137010 44135010
Qty. Qty.
1-
1-
22
42
32
42
42
42907210 42907190
42
8 |
5 |
14 |
8 |
|
Form 43343300 |
-6- |
May 2013 |
|
System Lengths |
70 Ft. System |
|
|
|
40 Ft. Pkg. |
30 Ft. Pkg. |
ETS 180-200 Body Packages – Aluminized /Hot Rolled |
44137010 |
44136040 |
|
Part # |
Each Body Package Includes: |
Qty. |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
- |
41932100 |
10 Ft. Tube less Flanges (Aluminized) |
1 |
- |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
2 |
3 |
43319100 |
Reflector, 9’ 11½” |
4 |
3 |
30462980 |
Tube Coupling |
3 |
3 |
43318000 |
Tube Hanger/Support Bracket, 13” |
4 |
3 |
43980010 |
Wire Hanger |
4 |
3 |
|
|
|
|
Body Fastener Kit (included in body packages) |
42907210 |
42907200 |
|
42873000 |
U-Bolt |
4 |
3 |
02127110 |
Hex Nut, 5/16-18 |
8 |
6 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
14 |
10 |
D. ETS 225-250 Body Package Descriptions
80 Ft. System
40 Ft. Pkg. 40 Ft. Pkg.
44137010 44137020
Qty. Qty.
1-
1-
24
44
34
44
44
42907210 42907210
44
8 |
8 |
14 |
14 |
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
System Lengths |
50 Ft. System |
|
|
50 Ft. Pkg. |
ETS 225-250 Body Packages – Alumi-Therm/Hot Rolled |
44138040 |
|
Part # |
Each Body Package Includes: |
Qty. |
42912179 |
10 Ft. Tube with (2) 6 Hole Flanges (Alumi-Therm) |
1 |
42912169 |
10 Ft. Tube with 6 Hole Flange (Alumi-Therm) |
1 |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
3 |
43319100 |
Reflector, 9’ 11½” |
5 |
30462980 |
Tube Coupling |
3 |
43318000 |
Tube Hanger/Support Bracket, 13” |
5 |
43980010 |
Wire Hanger |
5 |
42907080 |
Tube Flange Fasteners (includes (6) ¼-20 screws/nuts) |
1 |
42921000 |
Tube Flange Gasket |
1 |
|
|
|
Body Fastener Kit (included in body packages) |
42907220 |
|
42873000 |
U-Bolt |
5 |
02127110 |
Hex Nut, 5/16-18 |
10 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
18 |
60 Ft. System
40 Ft. Pkg. 20 Ft. Pkg.
44137030 44135010
Qty. Qty.
1-
1-
22
42
22
42
42
1-
1-
42907210 42907190
42
8 |
5 |
14 |
8 |
|
|
System Lengths |
70 Ft. System |
|
|
|
|
40 Ft. Pkg. |
30 Ft. Pkg. |
ETS 225-250 Body Packages – Alumi-Therm/Hot Rolled |
44137030 |
44136040 |
||
Part # |
|
Each Body Package Includes: |
Qty. |
Qty. |
42912179 |
10 |
Ft. Tube with (2) 6 Hole Flanges (Alumi-Therm) |
1 |
- |
42912169 |
10 |
Ft. Tube with 6 Hole Flange (Alumi-Therm) |
1 |
- |
41932101 |
10 |
Ft. Tube less Flanges (Hot Rolled) |
2 |
3 |
43319100 |
Reflector, 9’ 11½” |
4 |
3 |
|
30462980 |
Tube Coupling |
2 |
3 |
|
43318000 |
Tube Hanger/Support Bracket, 13” |
4 |
3 |
|
43980010 |
Wire Hanger |
4 |
3 |
|
42907080 |
Tube Flange Fasteners (includes (6) ¼-20 screws/nuts) |
1 |
- |
|
42921000 |
Tube Flange Gasket |
1 |
- |
80 Ft. System
40 Ft. Pkg. 40 Ft. Pkg.
44137030 44137020
Qty. |
Qty. |
1 |
- |
1 |
- |
2 |
4 |
4 |
4 |
2 |
4 |
4 |
4 |
4 |
4 |
1 |
- |
1 |
- |
Form 43343300 |
|
May 2013 |
-7- |
Body Fastener Kit (included in body packages) |
42907210 |
42907200 |
|
42873000 |
U-Bolt |
4 |
3 |
02127110 |
Hex Nut, 5/16-18 |
8 |
6 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
14 |
10 |
E.ETS 40-175 Body Package Descriptions – ALC Option (Aluminized Calorized)
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
42907210 |
42907210 |
4 |
4 |
8 |
8 |
14 |
14 |
|
|
15 Ft. |
20 Ft. |
30 Ft. |
40 Ft. |
50 Ft. |
|
System Lengths |
System |
System |
System |
System |
System |
|
|
15 Ft. Pkg. |
20 Ft. Pkg. |
30 Ft. Pkg. |
40 Ft. Pkg. |
50 Ft. Pkg. |
ETS 40-175 Body Packages – ALC –Aluminized |
44134010 |
44135020 |
44136020 |
44137040 |
44138060 |
|
Part # |
Each Body Package Includes: |
Qty. |
Qty. |
Qty. |
Qty. |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
1 |
1 |
1 |
1 |
41932100 |
10 Ft. Tube less Flanges (Aluminized) |
- |
1 |
2 |
3 |
4 |
41932050 |
5 Ft. Tube less Flanges (Aluminized) |
1 |
- |
- |
- |
- |
43319100 |
Reflector, 9’ 11½” |
1 |
2 |
3 |
4 |
5 |
43319050 |
Reflector, 4’ 11½” |
1 |
- |
- |
- |
- |
30462980 |
Tube Coupling |
1 |
1 |
2 |
3 |
4 |
43318000 |
Tube Hanger/Support Bracket, 13” |
2 |
2 |
3 |
4 |
5 |
43980010 |
Wire Hanger |
2 |
2 |
3 |
4 |
5 |
|
|
|
|
|
|
|
Body Fastener Kit (included in body packages) |
42907190 |
42907190 |
42907200 |
42907210 |
42907220 |
|
42873000 |
U-Bolt |
2 |
2 |
3 |
4 |
5 |
02127110 |
Hex Nut, 5/16-18 |
5 |
5 |
6 |
8 |
10 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
8 |
8 |
10 |
14 |
18 |
F.ETU 40-175 Body Package Descriptions
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
|
20 Ft. |
30 Ft. |
40 Ft. |
50 Ft. |
|
System Lengths |
System |
System |
System |
System |
|
|
20 Ft. Pkg. |
30 Ft. Pkg. |
40 Ft. Pkg. |
50 Ft. Pkg. |
ETU 40-175 Body Packages – Aluminized/Hot Rolled |
44135000 |
44136010 |
44137000 |
44138010 |
|
Part # |
Each Body Package Includes: |
Qty. |
Qty. |
Qty. |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
1 |
1 |
1 |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
1 |
1 |
3 |
3 |
41932051 |
5 Ft. Tube less Flanges (Hot Rolled) |
- |
2 |
- |
2 |
43319100 |
Reflector, 9’ 11½” |
2 |
2 |
4 |
4 |
43319050 |
Reflector, 4’ 11½” |
- |
2 |
- |
2 |
30462980 |
Tube Coupling |
1 |
3 |
3 |
5 |
43318000 |
Tube Hanger/Support Bracket, 13” |
2 |
4 |
4 |
6 |
43980010 |
Wire Hanger |
2 |
4 |
4 |
6 |
|
|
|
|
|
|
Body Fastener Kit (included in body packages) |
42907190 |
42907200 |
42907210 |
42907220 |
|
42873000 |
U-Bolt |
2 |
4 |
4 |
5 |
02127110 |
Hex Nut, 5/16-18 |
5 |
8 |
8 |
10 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
8 |
14 |
14 |
18 |
|
|
|
|
|
|
|
U-Bend package |
43208020 |
43208020 |
43208020 |
43208020 |
42913020 |
U-Bend |
1 |
1 |
1 |
1 |
43318500 |
31” Tube Support/Hanger Bracket |
1 |
1 |
1 |
1 |
30462980 |
Tube Coupling |
1 |
1 |
1 |
1 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
2 |
2 |
2 |
2 |
|
Form 43343300 |
-8- |
May 2013 |
G.ETU 180-200 Body Package Descriptions
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
System Lengths |
50 Ft. System |
|
|
50 Ft. Pkg. |
ETU 180-200 Body Packages – Aluminized/Hot Rolled |
44138030 |
|
Part # |
Each Body Package Includes: |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
41932100 |
10 Ft. Tube less Flanges (Aluminized) |
1 |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
2 |
41932051 |
5 Ft. Tube less Flanges (Hot Rolled) |
2 |
43319100 |
Reflector, 9’ 11½” |
4 |
43319050 |
Reflector, 4’ 11½” |
2 |
30462980 |
Tube Coupling |
5 |
43318000 |
Tube Hanger/Support Bracket, 13” |
6 |
43980010 |
Wire Hanger |
6 |
|
|
|
Body Fastener Kit (included in body packages) |
42907221 |
|
42873000 |
U-Bolt |
6 |
02127110 |
Hex Nut, 5/16-18 |
13 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
24 |
|
|
|
|
U-Bend package |
43208020 |
42913020 |
U-Bend |
1 |
43318500 |
31” Tube Support/Hanger Bracket |
1 |
30462980 |
Tube Coupling |
1 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
2 |
60 Ft. System
40 Ft. Pkg. 20 Ft. Pkg.
44137010 44135010
Qty. Qty.
1-
1-
22
--
42
--
32
42
42
42907210 42907190
42
8 |
5 |
14 |
8 |
43208020 43208020
11
11
11
2 2
|
System Lengths |
70 Ft. System |
80 Ft. System |
||
|
|
40 Ft. Pkg. |
30 Ft. Pkg. |
40 Ft. Pkg. |
40 Ft. Pkg. |
ETU 180-200 Body Packages – Aluminized/Hot Rolled |
44137050 |
44136040 |
44137010 |
44137020 |
|
Part # |
Each Body Package Includes: |
Qty. |
Qty. |
Qty. |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
- |
1 |
- |
41932100 |
10 Ft. Tube less Flanges (Aluminized) |
1 |
- |
1 |
- |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
1 |
3 |
2 |
4 |
41932051 |
5 Ft. Tube less Flanges (Hot Rolled) |
2 |
- |
- |
- |
43319100 |
Reflector, 9’ 11½” |
3 |
3 |
4 |
4 |
43319050 |
Reflector, 4’ 11½” |
2 |
- |
- |
- |
30462980 |
Tube Coupling |
4 |
3 |
3 |
4 |
43318000 |
Tube Hanger/Support Bracket, 13” |
5 |
3 |
4 |
4 |
43980010 |
Wire Hanger |
5 |
3 |
4 |
4 |
|
|
|
|
|
|
Body Fastener Kit (included in body packages) |
42907220 |
42907200 |
42907210 |
42907210 |
|
42873000 |
U-Bolt |
5 |
3 |
4 |
4 |
02127110 |
Hex Nut, 5/16-18 |
10 |
6 |
8 |
8 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
18 |
10 |
14 |
14 |
|
|
|
|
|
|
|
U-Bend package |
43208020 |
43208020 |
43208020 |
43208020 |
42913020 |
U-Bend |
1 |
1 |
1 |
1 |
43318500 |
31” Tube Support/Hanger Bracket |
1 |
1 |
1 |
1 |
30462980 |
Tube Coupling |
1 |
1 |
1 |
1 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
2 |
2 |
2 |
2 |
Form 43343300 |
|
May 2013 |
-9- |
H.ETU 225-250 Body Package Descriptions
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
System Lengths |
50 Ft. System |
|
|
50 Ft. Pkg. |
ETU 225-250 Body Packages – Alumi-Therm/Hot Rolled |
44138050 |
|
Part # |
Each Body Package Includes: |
Qty. |
42912179 |
10 Ft. Tube with (2) 6 Hole Flanges (Alumi-Therm) |
1 |
42912169 |
10 Ft. Tube with 6 Hole Flange (Alumi-Therm) |
1 |
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
2 |
41932051 |
5 Ft. Tube less Flanges (Hot Rolled) |
2 |
43319100 |
Reflector, 9’ 11½” |
4 |
43319050 |
Reflector, 4’ 11½” |
2 |
30462980 |
Tube Coupling |
4 |
43318000 |
Tube Hanger/Support Bracket, 13” |
6 |
43980010 |
Wire Hanger |
6 |
42907080 |
Tube Flange Fasteners (includes (6) ¼-20 screws/nuts) |
1 |
42921000 |
Tube Flange Gasket |
1 |
|
|
|
Body Fastener Kit (included in body packages) |
42907221 |
|
42873000 |
U-Bolt |
6 |
02127110 |
Hex Nut, 5/16-18 |
13 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
24 |
|
|
|
|
U-Bend package |
43208020 |
42913020 |
U-Bend |
1 |
43318500 |
31” Tube Support/Hanger Bracket |
1 |
30462980 |
Tube Coupling |
1 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
2 |
60 Ft. System
40 Ft. Pkg. |
20 Ft. Pkg. |
44137030 |
44135010 |
Qty. |
Qty. |
1 |
- |
1 |
- |
2 |
2 |
- |
- |
4 |
2 |
- |
- |
2 |
2 |
4 |
2 |
4 |
2 |
1 |
- |
1 |
- |
42907210 |
42907190 |
4 |
2 |
8 |
5 |
14 |
8 |
43208020 |
43208020 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
System Lengths |
70 Ft. System |
80 Ft. System |
||||
|
|
40 Ft. Pkg. |
|
30 Ft. Pkg. |
|
40 Ft. Pkg. |
40 Ft. Pkg. |
ETU 225-205 Body Packages – Alumi-Therm/Hot Rolled |
44137060 |
|
|
44136040 |
44137030 |
44137020 |
|
Part # |
Each Body Package Includes: |
Qty. |
|
Qty. |
|
Qty. |
Qty. |
42912179 |
10 Ft. Tube with (2) 6 Hole Flanges (Alumi-Therm) |
1 |
- |
|
1 |
- |
|
42912169 |
10 Ft. Tube with 6 Hole Flange (Alumi-Therm) |
1 |
- |
|
1 |
- |
|
41932101 |
10 Ft. Tube less Flanges (Hot Rolled) |
1 |
3 |
|
2 |
4 |
|
41932051 |
5 Ft. Tube less Flanges (Hot Rolled) |
2 |
- |
|
- |
- |
|
43319100 |
Reflector, 9’ 11½” |
3 |
3 |
|
4 |
4 |
|
43319050 |
Reflector, 4’ 11½” |
2 |
- |
|
- |
- |
|
30462980 |
Tube Coupling |
3 |
3 |
|
2 |
4 |
|
43318000 |
Tube Hanger/Support Bracket, 13” |
5 |
3 |
|
4 |
4 |
|
43980010 |
Wire Hanger |
5 |
3 |
|
4 |
4 |
|
42907080 |
Tube Flange Fasteners (includes (6) ¼-20 screws/nuts) |
1 |
- |
|
1 |
- |
|
42921000 |
Tube Flange Gasket |
1 |
- |
|
1 |
- |
|
|
|
|
|
|
|
||
Body Fastener Kit (included in body packages) |
42907220 |
42907200 |
42907210 |
42907210 |
|||
42873000 |
U-Bolt |
5 |
|
3 |
|
4 |
4 |
02127110 |
Hex Nut, 5/16-18 |
10 |
|
6 |
|
8 |
8 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
18 |
|
10 |
|
14 |
14 |
|
|
|
|||||
|
U-Bend package |
43208020 |
43208020 |
43208020 |
43208020 |
||
42913020 |
U-Bend |
1 |
|
1 |
|
1 |
1 |
43318500 |
31” Tube Support/Hanger Bracket |
1 |
|
1 |
|
1 |
1 |
30462980 |
Tube Coupling |
1 |
|
1 |
|
1 |
1 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
2 |
|
2 |
|
2 |
2 |
|
|
|
|
|
|
Form 43343300 |
|
|
-10- |
|
|
|
|
|
May 2013 |
I.ETU 40-175 Body Package Descriptions – ALC Option (Aluminized Calorized)
(PACKAGE PART NUMBER IS INDICATED ON THE OUTSIDE OF EACH CORRESPONDING CARTON.)
|
|
20 Ft. |
30 Ft. |
40 Ft. |
50 Ft. |
|
System Lengths |
System |
System |
System |
System |
|
|
20 Ft. Pkg. |
30 Ft. Pkg. |
40 Ft. Pkg. |
50 Ft. Pkg. |
ETU 40-175 Body Packages – Aluminized |
44135020 |
44136030 |
44137040 |
44138070 |
|
Part # |
Each Body Package Includes: |
Qty. |
Qty. |
Qty. |
Qty. |
42912180 |
10 Ft. Tube with 12 Hole Flange (Aluminized) |
1 |
1 |
1 |
1 |
41932100 |
10 Ft. Tube less Flanges (Aluminized) |
1 |
1 |
3 |
3 |
41932050 |
5 Ft. Tube less Flanges (Aluminized) |
- |
2 |
- |
2 |
43319100 |
Reflector, 9’ 11½” |
2 |
2 |
4 |
4 |
43319050 |
Reflector, 4’ 11½” |
- |
2 |
- |
2 |
30462980 |
Tube Coupling |
1 |
3 |
3 |
5 |
43318000 |
Tube Hanger/Support Bracket, 13” |
2 |
4 |
4 |
6 |
43980010 |
Wire Hanger |
2 |
4 |
4 |
6 |
|
|
|
|
|
|
Body Fastener Kit (included in body packages) |
42907190 |
42907210 |
42907210 |
42907221 |
|
42873000 |
U-Bolt |
2 |
4 |
4 |
5 |
02127110 |
Hex Nut, 5/16-18 |
5 |
8 |
8 |
10 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
8 |
14 |
14 |
18 |
|
|
|
|
|
|
|
U-Bend package |
43208020 |
43208020 |
43208020 |
43208020 |
42913020 |
U-Bend |
1 |
1 |
1 |
1 |
43318500 |
31” Tube Support/Hanger Bracket |
1 |
1 |
1 |
1 |
30462980 |
Tube Coupling |
1 |
1 |
1 |
1 |
02189020 |
HWHSM Screw, #10-16 x ½” TEKS |
2 |
2 |
2 |
2 |
6.1) ACCESSORY PACKAGES
A.End Reflector Accessory Package, Part #43341010
(1 PKG. PER ETS SERIES OR 2 PKGS. PER ETU SERIES)
CONTAINS:
End Reflector, #43320000……QTY–2 Speed Clips, #02266010……QTY–4
B.Elbow Accessory Package, Part #43208010
(OPTION FOR ETS SERIES ONLY)
CONTAINS:
Elbow, #43175000……QTY–1
#10-16 x ½ Self-Drilling Screws, #02189020……QTY–2 Tube Coupling, #30462980……QTY–1
6”
(15cm)
12” (30cm)
END REFLECTOR
13”
(33cm)
13”
(33cm)
C. Corner Reflector Accessory Package, Part #43342000
(OPTION FOR ETS SERIES ONLY)
CONTAINS: |
24” |
(61cm) |
Corner Reflector Assembly, #43345000……QTY–1
Speed Clips, #02266010……QTY–4
24”
(61cm)
Form 43343300 |
|
May 2013 |
-11- |
D.U-Bend Package, Part #43208020
(OPTION FOR ETU SERIES ONLY)
CONTAINS:
U-Bend, #42913020……QTY–1
#10-16 x ½ Self-Drilling Screws, #02189020……QTY–2 Tube Coupling, #30462980……QTY–1
31” Tube Support/Hanger Bracket, #43318500……QTY–1
E.U-Bend Reflector Package, Part #43488000
(OPTION FOR ETU SERIES ONLY)
CONTAINS:
U-Bend Reflector, #43490000……QTY–1 U-Bend End Reflector, #43490050……QTY–1 Speed Clips, #02266010……QTY–11
#10-16 x ½ Self-Drilling Screws, #02189020……QTY–4 Installation Form, #43489000……QTY–1
F.31” Hanger/Tube Support, Part #43318500
(OPTION FOR ANGLE MOUNTING OF ETU SERIES)
18”
(46cm)
30 3/4” (78cm) Length = 24” (61cm)
31”
(79cm)
18” (46cm)
Tube Centers
G. |
Exhaust Hood Package, Part #42924000 |
7 1/2” |
6” |
|
|
(15cm) |
|
|
|
(19cm) |
|
|
|
|
CONTAINS: |
|
3 3/4” (10cm) |
|
Exhaust Hood Assembly, #42925540……QTY–1 |
|
|
|
#8-18 x ½ Self-Drilling Screws, #02189030……QTY–2 |
3 1/2” (9cm) |
|
|
|
Bird |
||
|
|
|
|
|
4” (10cm) |
|
Screen |
|
|
|
|
|
Side View |
|
Front View |
|
Form 43343300 |
-12- |
May 2013 |
7.0) TYPICAL LAYOUTS
15FT. SYSTEM
60 FT. SYSTEM
20 FT. SYSTEM
30 FT. SYSTEM
70 FT. SYSTEM
40 FT. SYSTEM
50 FT. SYSTEM
80 FT. SYSTEM
LEGEND |
|
|
Control Unit |
|
5 FT. Body Section |
|
||
Draft Inducer Unit |
|
90 Deg. Elbow * |
10 FT. Body Section |
|
180 Deg. U-Bend |
*Minimum Distance Permitted Between Burner and 90Elbow
|
ETS 40 to ETS 100 |
10 FT. |
|
|
|
|
ETS 110 to ETS 175 |
15 FT. |
|
|
|
|
ETS 180 to ETS 250 |
20 FT. |
|
|
|
NOTES:
1.In all configurations, the control unit must be connected directly to either a) the 12-radial hole flange of the 10 ft. aluminized steel start/end tube section (for ETS/ETU 40-200 models) or b) the 6-hole flange of the 10 ft. alumi-therm steel starting tube section (for ETS/ETU 225 and 250 models). Failure to attach the control box to the 6-hole flange for ETS/ETU 225-250 as indicated above will void the manufacturer’s warranty.
2.Joining of two 90º elbows directly together to form a “Z” shape IS NOT permitted.
3.5 Ft. Body Packages may be utilized on any of these heaters to yield heater lengths from 15 ft. to 80 ft.
4.Any configuration of components not shown in the illustrations may be used except as noted in 1 and 2 above.
Form 43343300 |
|
May 2013 |
-13- |
MODEL |
EMITTER LENGTH |
MODEL |
EMITTER LENGTH |
|||
Min. |
Max. |
Min. |
Max. |
|||
|
|
|||||
ETS 40 (ETU 40) |
15 Ft. (20 Ft.) |
20 Ft. (20 Ft.) |
ETS 130 (ETU 130) |
30 Ft. (30 Ft.) |
50 Ft. (50 Ft.) |
|
ETS 50 (ETU 50) |
15 Ft. (20 Ft.) |
30 Ft. (30 Ft.) |
ETS 140 (ETU 140) |
40 Ft. (40 Ft.) |
50 Ft. (50 Ft.) |
|
ETS 60 (ETU 60) |
20 Ft. (20 Ft.) |
30 Ft. (30 Ft.) |
ETS 150 (ETU 150) |
40 Ft. (40 Ft.) |
50 Ft. (50 Ft.) |
|
ETS 75 (ETU 75) |
20 Ft. (20 Ft.) |
30 Ft. (30 Ft.) |
ETS 160 (ETU 160) |
40 Ft. (40 Ft.) |
50 Ft. (50 Ft.) |
|
ETS 80 (ETU 80) |
30 Ft. (30 Ft.) |
40 Ft. (40 Ft.) |
ETS 175 (ETU 175) |
40 Ft. (40 Ft.) |
50 Ft. (50 Ft.) |
|
ETS 90 (ETU 90) |
30 Ft. (30 Ft.) |
40 Ft. (40 Ft.) |
ETS 180 (ETU 180) |
50 Ft. (50 Ft.) |
80 Ft. (80 Ft.) |
|
ETS 100 (ETU 100) |
30 Ft. (30 Ft.) |
40 Ft. (40 Ft.) |
ETS 200 (ETU 200) |
50 Ft. (50 Ft.) |
80 Ft. (80 Ft.) |
|
ETS 110 (ETU 110) |
30 Ft. (30 Ft.) |
40 Ft. (40 Ft.) |
ETS 225 (ETU 225) |
50 Ft. (50 Ft.) |
80 Ft. (80 Ft.) |
|
ETS 120 (ETU 120) |
30 Ft. (30 Ft.) |
40 Ft. (40 Ft.) |
ETS 250 (ETU 250) |
50 Ft. (50 Ft.) |
80 Ft. (80 Ft.) |
|
ETS 125 (ETU 125) |
30 Ft. (30 Ft.) |
50 Ft. (50 Ft.) |
|
|
|
7.1) TYPICAL ASSEMBLY LAYOUT – ETS 180-250 SERIES
Aluminized Calorized Steel Tube (ALC) |
Hot Rolled Steel Tube (HRS)* |
||
(with one 12-radial hole Flange) |
|||
|
|||
|
Aluminized Calorized Steel Tube (ALC) |
||
Control Box |
Tube Coupling |
|
|
50 FT. |
|
|
|
Shown |
|
|
Hot Rolled Steel Tube (HRS)
Draft Draft
Inducer Inducer
Flange
* Additional tubes of this type may be added to increase the heater length up to a maximum of 80 ft.
Models: ETS 180-200
Alumi-Therm Calorized Steel Tube (ATC) |
Hot Rolled Steel Tube (HRS)* |
|
(with two 6-hole Flanges) |
||
|
Control Box
50 FT.
Shown
Alumi-Therm Calorized Steel Tube (ATC) (with one 6-hole Flange)
Tube Coupling
Hot Rolled Steel Tube (HRS)
Draft Draft
Inducer Inducer
Flange
* Additional tubes of this type may be added to increase the heater length up to a maximum of 80 ft.
Models: ETS 225-250
|
Form 43343300 |
-14- |
May 2013 |
7.2) TYPICAL ASSEMBLY LAYOUT – ETU 180-250 SERIES
|
|
Hot Rolled Steel Tube (HRS) |
|
|
|
|
|
|||||||||||
Draft |
Draft |
|
|
|
|
|
|
Hot Rolled Steel Tube (HRS)* |
|
|
|
U-Bend |
||||||
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Inducer |
Inducer |
|
Tube Coupling |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
Flange |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50 FT.
Shown
|
|
|
|
|
|
|
|
|
|
|
|
Control Box |
|
|
|
||
Aluminized Calorized Steel Tube (ALC) Aluminized Calorized Steel Tube (ALC) |
|||||
|
|
||||
|
|
(with one 12-radial hole Flange) |
* Additional tubes of this type may be added to increase the heater length up to a maximum of 80 ft.
Models: ETU 180-200
|
|
Hot Rolled Steel Tube (HRS) |
Hot Rolled Steel Tube (HRS)* |
|||||||||||||||
Draft |
Draft |
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Inducer |
Inducer |
Tube Coupling |
|
|
|
|
|
|
|
|
U-Bend |
|||||||
|
|
Flange |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50 FT.
Shown
Control Box Alumi-Therm Calorized Steel Tube (ATC) (with two 6-hole Flanges)
Alumi-Therm Calorized Steel Tube (ATC) (with one 6-hole Flange)
* Additional tubes of this type may be added to increase the heater length up to a maximum of 80 ft.
Models: ETU 225-250
Form 43343300 |
|
May 2013 |
-15- |
|
10 FT Tube |
|
|
|
5 FT Tube |
|
|
|
|
Assembly |
|
|
|
|
|
|
|
|
(typical) |
|
|
12” |
Assembly |
|
10-9/16” |
|
|
|
|
|
(30cm) |
|
|
|
|
18” |
180” |
|
|
|
Junction Box |
(27cm) |
8-1/2” |
|
|
|
|
|
|||||
|
|
|
|
|
||||
(46cm) |
(457cm) |
108” |
48” |
|
(electric supply) |
|
(22cm) |
|
|
|
|
|
|
Sight |
|||
|
(274cm) |
(122cm) |
|
|
|
|||
Models: |
|
|
|
|
|
|
|
Glass |
ETS 40, 50 |
|
|
|
|
|
9-1/4” |
|
|
|
|
|
|
|
|
(24cm) |
|
1/2” MPT Gas |
|
|
|
|
|
|
10-7/8” |
|
|
Control |
|
|
|
|
Draft |
|
Connection |
|
|
|
|
|
(28cm) |
|
|||
|
|
|
|
|
|
|||
Box |
|
|
|
12” |
Inducer |
7” |
|
|
|
|
|
|
|
(18cm) |
|
|
|
|
|
|
240” |
(30cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
108” |
(610cm) |
|
108” |
|
|
|
|
|
|
|
|
|
|
|||
|
(274cm) |
|
|
(274cm) |
|
|
|
|
Models: |
|
|
|
|
|
|
|
End View |
ETS 60, 75 |
|
|
|
|
|
|
|
|
8-1/2” (22cm)
.Shown .Ft 50 to Up Dimensions Typical
|
|
12” |
|
|
12” |
|
|
|
|
(30cm) |
|
|
|
(30cm) |
360” |
|
|
|
|
|
|
||
- |
|
|
|
|
|
|
|
(914cm) |
|
|
|
-16 |
108” |
|
108” |
108” |
|
(274cm) |
|
|
(274cm) |
(274cm) |
|
|
|
|
|||
|
Models: |
|
|
|
|
|
ETS 80, 90, |
|
|
|
|
|
100, 110, 120, |
|
|
|
|
|
125, 130 |
|
|
|
|
|
12” |
|
12” |
12” |
|
(30cm) |
|
(30cm) |
(30cm) |
|
|
480” |
|
|
108” |
108” |
(1219cm) |
108” |
108” |
|
||||
(274cm) |
(274cm) |
|
(274cm) |
(274cm) |
Models: |
|
|
|
|
ETS 140, 150, |
|
|
|
|
160, 175 |
|
|
|
|
|
|
12” |
|
|
12” |
4” Tube Coupling |
|
12” |
12” |
|
|
|
|
(30cm) |
|
|
(30cm) |
(typical) |
(30cm) |
(30cm) |
|
|
|
|
|
|
|
|
600” |
|
|
|
|
|
|
|
108” |
|
108” |
(1524cm) |
108” |
|
108” |
|
108” |
|
|
|
|
|
|
|
|
|
|||||
|
(274cm) |
|
(274cm) |
|
|
(274cm) |
|
(274cm) |
|
(274cm) |
|
|
Models: |
|
|
|
|
|
|
|
|
|
|
|
ETS 180, 200, |
|
|
|
|
|
|
|
|
|
|
|
225, 250 |
|
|
|
|
|
|
|
|
|
|
|
Bottom View |
|
|
|
|
|
|
|
|
|
|
|
13” Tube Support/ |
Wire Hanger |
13” Tube Support/ |
Wire Hanger |
13” Tube Support/ |
Wire Hanger |
13” Tube Support/ |
Wire Hanger |
13” Tube Support/ |
Wire Hanger |
|
43343300 Form 2013 May |
Hanger Bracket |
|
Hanger Bracket |
|
|
Hanger Bracket |
|
Hanger Bracket |
|
Hanger Bracket |
|
|
|
|
|
|
|
|
|
|
|
|
SERIES ETS – DIMENSIONS 0).8
8.1) |
DIMENSIONS – ETU SERIES |
|
|
|
|
|
||||
Typical Dimensions Up to 50 Ft. Shown. |
|
|
|
|
|
|
|
|||
|
18” |
|
120” |
|
|
15” |
|
|
|
|
(46cm) |
108” |
(305cm) |
|
(38cm) |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
Models: |
|
(274cm) |
|
|
|
10 FT Tube |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
ETU 40, 50, |
|
|
|
|
|
|
Assembly |
|
|
|
60, 75 |
|
|
|
|
|
|
(typical) |
|
|
|
|
Control |
|
|
|
|
|
5 FT Tube |
|
|
|
|
Box |
|
|
|
|
|
|
|
||
|
|
|
|
|
12” |
Assembly |
|
|
||
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Draft |
180” |
|
|
(30cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Inducer |
|
|
|
|
|
|
|
||
|
(457cm) |
108” |
|
48” |
|
|
|
|||
|
|
|
|
|
|
|||||
Models: |
|
|
(274cm) |
(122cm) |
|
|
|
|||
ETU 50, 60, |
|
|
|
|
|
|
|
|
U-Bend |
|
75, 80, 90, |
|
|
|
|
|
|
|
|
|
|
100, 110, |
|
|
|
|
|
|
|
|
|
|
120, 125, |
|
|
|
|
|
|
|
|
|
|
130 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12” |
|
|
|
|
|
|
|
|
|
240” |
(30cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
108” |
(610cm) |
|
108” |
|
|
|
|
|
|
|
|
|
|
|
|
|||
Models: |
|
(274cm) |
|
|
(274cm) |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
ETU 80, 90, |
|
|
|
|
|
|
|
|
|
|
100, 110, |
|
|
|
|
|
|
|
|
|
|
120, 125, |
|
|
|
|
|
|
|
|
|
|
130, 140, |
|
|
|
|
|
|
|
|
|
4” Tube Coupling |
150, 160, |
|
|
|
|
|
|
|
|
12” |
(typical) |
175 |
|
|
|
|
|
12” |
|
|
|
|
|
|
|
|
|
|
|
|
(30cm) |
||
|
|
|
|
|
|
(30cm) |
300” |
|
||
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
108” |
|
|
(762cm) |
108” |
|
48” |
|
Models: |
|
(274cm) |
|
|
(274cm) |
|
(122cm) |
|||
ETU 125, |
|
|
|
|
|
|
|
|
|
|
130, 140, |
|
|
|
|
|
|
|
|
|
|
150, 160, |
|
|
|
|
|
|
|
|
|
|
175, 180, |
|
|
|
|
|
|
|
|
|
|
200, 225, |
|
|
|
|
|
|
|
|
|
|
250 |
|
Bottom View |
|
|
|
|
|
|||
|
|
|
|
|
|
|
31” Tube Support/ Hanger Brackets (typical at control end)
Shipped with U-Bend Package
Wire Hangers |
13” Tube Support/ |
Wire Hangers |
13” Tube Support/ |
(typical) |
Hanger Brackets |
(typical) |
Hanger Brackets |
|
(typical) |
|
(typical) |
Junction Box |
|
|
|
8-1/2” |
(electric supply) |
10-9/16” |
Sight |
||
|
|
(27cm) |
(22cm) |
|
|
|
Glass |
||
|
|
|
|
|
|
|
|
1/2” MPT Gas |
|
10-7/8” |
|
|
Connection |
8-1/2” |
|
|
|
||
(28cm) |
|
|
|
|
|
|
|
(22cm) |
|
7” |
|
|
|
|
|
|
|
|
|
(18cm) |
|
|
|
|
31” Tube Support/ |
Draft |
|
U-Bend |
|
|
18” (46cm) |
|
||
Hanger Bracket |
|
Control |
||
Inducer |
|
|||
|
|
|
Box |
|
|
|
|
31” (79cm) |
|
|
|
|
|
end view
Form 43343300 |
|
May 2013 |
-17- |