SPECIFICATIONS
MODEL XLR-600-SL
COOKING CAPACITIES FOR THE XLR-600
Pork Butt (7 lb.) 108 pieces 756 lb. total St. Louis Ribs (2.75lb.) 48 pieces 132 lb. total w/Optional Rib Racks 120 pieces 330 lb total Chicken (3lb.) 144 pieces 432 lb. total Brisket (12 lb.) 54 pieces 648 lb. total Spare Ribs (3.5lb.) 36 pieces 126 lb. total
22"
22"
87 3/8"
16"
18
3/4"
12
5
14"
15"
1/2"
1/2"
6” Flue 10” Flue
NOTE:
Dimensions Show position of the 10” flue on the optional smoke extractor on the -SLSE Model.
22"
33"
Optional Smoke
Extractor
14"
47"
Top View
87 3/8"
79 3/8"
Optional Smoke
10"
61"
Extractor
NOTE:
Drawings Show the Optional Smoke Extractor on SLSE Models.
1/
5
2
"
Electrical
Connection
for VSP
Hood
76"
19"
15"
Side View
1/2"
5
Electrical
8"
1/2"
16
Connection
for VSP Hood
1/2"
12
XLR-600-SL
Electrical Requirements: 120 volts AC, 60 hertz, 1 phase, 15 amp wiring required.
Gas Requirements: 125,000 btu, 1/2 NPT Construction: Inner Liner: 12 gauge H.R. Steel or
12 gauge Stainless Steel. Exterior: 22-gauge Polished Stainless Steel
Firebox: 14” Diameter 1/4” thick H.R. pipe. 1/4” thick firebox door. Uses wood logs or charcoal. Capacity: 3-4 logs 4”-6” dia. 12-16” long.
Dimensions: 76” tall, 47” wide, 87 3/8” deep
79 3/8"
(including covers) w/ 15” legs
Shell Dimensions: 61” tall, 33” wide, 79 3/8” long. Food Racks: Rotisserie with four (4) hanger racks,
each with three (3) 18”x 22” food racks (12 Total). Thirty Three (33) Sq.Ft. of Cooking Surface. 4 11/16” Spacing between food racks.
Air Circulation: Low Velocity Convection Fan. Temperature Range: 100-325 degrees F. Burner: Electronic Pilot Gas Burner
(Specify Natural or L.P. gas.)
Approvals: UL, ULC, NSF Venting: See back page for venting instructions.
XLR-600-SL
VENTING INSTALLATION
VSP HOOD SYSTEM: Purchased through Southern Pride
2
4
VSP HOODS are U/L Listed to the applicable Southern Pride oven models and are NSF Certified.
HOOD SYSTEM TO INCLUDE:
1. Ventilation Hood
2. Two speed fan (1380/2000)
3. Curb with vented extension and hinge kit (Specify roof pitch)
4. Grease capture trough
1
5. Combustion chamber flue vent
SUPPLIED BY CUSTOMER:
6. Duct from hood to fan
NOTE: If you have a duct longer than 10 feet or an elbow in your duct your installation, it may require a larger capacity exhaust fan. Please specify your duct requirements when ordering the VSP Hood System.
XLR-600-SL with recommended optional VSP Vent Hood System.
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED
FOR COMMERCIAL COOKING APPLIANCES.
NOTE: THE S IX I NCH ALL FUEL CH IMN EY SHOULD EX TEND AT LEAST 3’ ABOVE THE HIGH EST SIDE OF THE ROOF OPENING AND BE AT LE AS T 2’ H I G HE R THAN AN Y P ORT ION OF THE BUI LDING WI THIN 10 ’. HORI Z ON TAL .
6” ALL FUEL CHIMNEY
EXHAUS T FAN
RAIN CAP
THROUGH THE WALL ­DIRECT VENT INST ALLA TION
NOTE 1. When installing an Oven through a
wall constructed of combustible material, use the Southern Pride Insulation Kit between the oven and the wall.
2. The room that the face of the oven is installed into should have a balanced or positive air pressure.
NOTE: THE 10” ALL FUEL SMO KE EX ­TRA C T OR CH IM N E Y TE R M I N A T E S A T THE ROO F CURB
10” ALL FUEL SMOKE EX TR AC TOR CH IMNE Y
If the room has negative air pressure, smoke could escape into the room during operation.
SUPPLIED BY SOUTHERN PRIDE: (*)
Smoke Extractor Damper with 10” chimney adapter plate
SUPPLIED BY CUSTOMER:
6” All Fuel Chimne y, 6” Rain Cap, and all accessories necessary for installation of the 6” chimney. 10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must be listed for use as a commercial kitchen ventilator), fan curb, and all accessories necessary for installation of the smoke extractor system.
3 SPECIFY ROOF PITCH
WHEN ORDERING
6
5
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48" from front, and 2" on back. Minimum clearances 18" to chimney connector and to smoke e xtractor chimney connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be reduced to 2" on left side.) May be installed through wall with zero clearance with BBR kit No. 2099.
ANY VENTILATION SYSTEM MUST BE INST ALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLA TION.