FOR GROUPS OF
SLIDING CELL DOORS
Maximum security.
8050L PNEUMATIC
LOCKING SYSTEM
The 8050L Locking System offers
complete selective electric
operation
or group from a remote control
station.
pneumatic cylinders over each
door. This system also provides
emergency pneumatic unlocking
from a remote location. Doors are
locked at top and bottom in both
the open and closed positions by
means of a concealed vertical lock
bar at the rear jamb of each door.
The vertical lock bar is deadlocked
at a third locking point inside the
horizontal cover box above the
door. Standard clear door opening
widths are from 2'4" to 3'2".
of sliding doors in a line
Doors are operated by
L O C K I N G S Y S T E M S
8050L
PNEUMATIC
LOCKING SYSTEM
FUNCTION:
ELECTRIC - A remote switch
activates
which raise a vertical lock bar and
propel
Individual lamp indicators on the
control
condition. A single switch can
provide
MECHANICAL - In the absence of
pneumatic or electrical power,
doors may be individually unlocked
with a manual release tool. Door
movement is by hand and door will
relock in either fully open or closed
position.
EMERGENCY GANG RELEASE
In an emergency, all doors in a cell
line may be simultaneously
unlocked from a remote
location
release system. While in
emergency release mode, doors
will not relock in any position.
pneumatic cylinders
the door open or closed.
panel show locked/unlocked
group unlocking.
-
using a pneumatic
TECHNICAL DATA:
• COVER BOX:
1' 0-3/4" H x 7-1/2" D
• COVER BOX MATERIAL:
7 gauge steel plate
• HINGED PANEL:
10 gauge steel
• DOOR ROLLERS:
3" diameter, machined
steel with sealed bearings
• VERTICAL LOCK BAR
DIMENSIONS:
5/8" SQ
of door
• FINISH: Prime paint
•
DOOR HANGER:
7 gauge steel plate
by full height
•
ELECTRICAL: 24 VDC
Minimum of five 24 volt
conductors are required between
the control point and the door,
except for those models
having the letter “K”
(keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.
• AIR REQUIREMENTS:
Air consumption varies with
door size at 80 PSIG.
Revised 3/09
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
C9
FOR GROUPS OF
SLIDING CELL DOORS
Maximum security.
STANDARD FEATURES:
• Bottom door guide
• Door hanger
• Pneumatic emergency release
• Sloped-front cover box
• Hinged cover panel for maintenance access
• Vertical lock bar assembly
• ASTM F1643 Certified
Horizontal and Vertical
Impact Test-Grade 1
• Prime paint finish
OPTIONAL FEATURES:
PILASTER RELEASE– (In lieu of
pneumatic release system.) Hip-high
paracentric keyed mechanical release
mounted in a full-height pilaster adjacent to
the receiving jamb.
Specify “8050LP-1” keyed one side.
L O C K I N G S Y S T E M S
8050L PNEUMATIC
LOCKING SYSTEM
8050L PNEUMATIC SLIDING DOOR SYSTEM
DETAIL A – SLOPED BOX
DETAIL B – VERTICAL LOCK JAMB BAR
ELECTRIC KEYSWITCH– Paracentric or mogul
keyed local electric control switch mounted below
mechanical release mechanism in pilaster.
Specify “8050LPK-1” for paracentric keyed
one side.
Specify “8050LPKM-1” for mogul keyed one side.
HOT DIP GALVANIZED FINISH - Available for external applications with lift-off cover panel only. Not
available with standard hinged cover panel. Specify
“G” when ordering. Example: 8050LP-1G
FACTORY-WIRED CONTROL CABLE
Specify “8050LWC.”
NOTE: Cover box minimum length =
overtravel) + (2 x clear opening) + 9".
(7"
For doors exceeding 300 lbs. and/or greater
than ’-” clear opening, contact factory.
THREE HOUR FIRE DOOR RATING AVAILABLE.
Standard cover box calculation does not apply to
fire rated doors.
COVER BOX SECTION
7-1/ 2” de ep x 1’-0-3/ 4” ta ll cov er box
fiel d wel ded 1” on 6 ” top and b ottom
DETAIL C – RECEIVER
RECEIVER JAMB SECTION
Flus h rec eiver jamb a llows frame
open ing a nd cle ar ope ning to
be the sa me.
Note: Other system configurations and details are available.
Call Customer Service for more information.
DETAIL D – BOTTOM DOOR GUIDE SECTION
8050L Shown
C10
Revised /12
P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211