Southern Folger 8050L User Manual

FOR GROUPS OF SLIDING CELL DOORS
Maximum security.
8050L PNEUMATIC LOCKING SYSTEM
The 8050L Locking System offers complete selective electric operation or group from a remote control station. pneumatic cylinders over each door. This system also provides emergency pneumatic unlocking from a remote location. Doors are locked at top and bottom in both the open and closed positions by means of a concealed vertical lock bar at the rear jamb of each door. The vertical lock bar is deadlocked at a third locking point inside the horizontal cover box above the door. Standard clear door opening widths are from 2'4" to 3'2".
of sliding doors in a line
Doors are operated by
L O C K I N G S Y S T E M S
8050L
PNEUMATIC
LOCKING SYSTEM
FUNCTION:
ELECTRIC - A remote switch activates which raise a vertical lock bar and propel Individual lamp indicators on the control condition. A single switch can provide
MECHANICAL - In the absence of pneumatic or electrical power, doors may be individually unlocked with a manual release tool. Door movement is by hand and door will relock in either fully open or closed position.
EMERGENCY GANG RELEASE In an emergency, all doors in a cell line may be simultaneously unlocked from a remote location release system. While in emergency release mode, doors will not relock in any position.
pneumatic cylinders
the door open or closed.
panel show locked/unlocked
group unlocking.
-
using a pneumatic
TECHNICAL DATA:
• COVER BOX: 1' 0-3/4" H x 7-1/2" D
• COVER BOX MATERIAL: 7 gauge steel plate
• HINGED PANEL: 10 gauge steel
• DOOR ROLLERS: 3" diameter, machined steel with sealed bearings
• VERTICAL LOCK BAR DIMENSIONS: 5/8" SQ of door
• FINISH: Prime paint
DOOR HANGER: 7 gauge steel plate
by full height
ELECTRICAL: 24 VDC Minimum of five 24 volt conductors are required between the control point and the door, except for those models having the letter “K” (keyswitch) in the suffix. Keyswitch models require minimum six conductors.
• AIR REQUIREMENTS: Air consumption varies with door size at 80 PSIG.
Revised 3/09
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
C9
FOR GROUPS OF SLIDING CELL DOORS
Maximum security.
STANDARD FEATURES:
• Bottom door guide
• Door hanger
• Pneumatic emergency release
• Sloped-front cover box
• Hinged cover panel for maintenance access
• Vertical lock bar assembly
• ASTM F1643 Certified Horizontal and Vertical Impact Test-Grade 1
• Prime paint finish
OPTIONAL FEATURES:
PILASTER RELEASE– (In lieu of pneumatic release system.) Hip-high paracentric keyed mechanical release mounted in a full-height pilaster adjacent to the receiving jamb. Specify “8050LP-1” keyed one side.
L O C K I N G S Y S T E M S
8050L PNEUMATIC
LOCKING SYSTEM
8050L PNEUMATIC SLIDING DOOR SYSTEM
DETAIL A – SLOPED BOX
DETAIL B – VERTICAL LOCK JAMB BAR
ELECTRIC KEYSWITCH– Paracentric or mogul keyed local electric control switch mounted below mechanical release mechanism in pilaster. Specify “8050LPK-1” for paracentric keyed one side. Specify “8050LPKM-1” for mogul keyed one side.
HOT DIP GALVANIZED FINISH - Available for exter­nal applications with lift-off cover panel only. Not available with standard hinged cover panel. Specify “G” when ordering. Example: 8050LP-1G
FACTORY-WIRED CONTROL CABLE Specify “8050LWC.”
NOTE: Cover box minimum length =
overtravel) + (2 x clear opening) + 9".
(7"
For doors exceeding 300 lbs. and/or greater
than ’-” clear opening, contact factory.
THREE HOUR FIRE DOOR RATING AVAILABLE.
Standard cover box calculation does not apply to fire rated doors.
COVER BOX SECTION
7-1/ 2” de ep x 1’-0-3/ 4” ta ll cov er box fiel d wel ded 1” on 6 ” top and b ottom
DETAIL C – RECEIVER
RECEIVER JAMB SECTION
Flus h rec eiver jamb a llows frame open ing a nd cle ar ope ning to be the sa me.
Note: Other system configurations and details are available.
Call Customer Service for more information.
DETAIL D – BOTTOM DOOR GUIDE SECTION
8050L Shown
C10
Revised /12
P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211