Southern Folger 10600 User Manual

0 (0)
DOOR MOUNTED FOR SWINGING DOORS
Minimum and medium security.
APPLICATION:
Designed for minimum and medium security areas where remote electric or local manual control of lever is desired. Door position switch and door closure are recommended. 204E power
transfer hinge is required.
E L E C T R I C L O C K S
10600
INSTITUTIONAL
MORTISE LOCK
FUNCTION:
10600E FAIL SECURE – Lever unlocks when power is applied.
10600EP FAIL SAFE – Lever locks when power is applied.
A variety of functions are available to meet job requirements. See function chart.
THIS LOCK IS NOT INTENDED FOR CELL APPLICATION.
UL
Revised 3/09
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
B17
E L E C T R I C L O C K S
SOUTHERN
STEEL
COMPANY
SOUTHERN
STEEL
COMPANY
SOUTHERN
STEEL
COMPANY
SOUTHERN
STEEL
COMPANY
SOUTHERN
STEEL
COMPANY
SOUTHERN
STEEL
COMPANY
SOUTHERN
STEEL
COMPANY
FUNCTIONS
10601
10601 Lockset
Latchbolt operated by lever either side,
except when both are locked out.
Key outside operates latchbolt when both
levers are locked out.
Deadlock actuator.
• 10601E: Both levers are locked, except when power is applied.
• 10601EP: Both levers are unlocked, except when power is applied.
10600 INSTITUTIONAL
MORTISE LOCK
10604 Lockset
Latchbolt operated by lever either side,
except when inside lever is locked out.
• Key inside operates latchbolt when inside lever is locked out.
Lever outside always active.
10604
Deadlock actuator.
• 10604E: Inside lever is locked, except when power is applied.
• 10604EP: Inside lever is unlocked, except when power is applied.
10602 Lockset
Latchbolt operated by lever either side,
except when both are locked out.
Key inside operates latchbolt when both
levers are locked out.
10602
Deadlock actuator.
• 10602E: Both levers are locked, except when power is applied.
• 10602EP: Both levers are unlocked, except when power is applied.
10605
10603 Lockset
Latchbolt operated by lever both sides,
except when outside lever is locked out.
Key outside operates latchbolt when
outside lever is locked out.
Lever inside always active.
10603
Deadlock actuator.
• 10603E: Outside lever is locked, except when power is applied.
• 10603EP: Outside lever is unlocked, except when power is applied.
10606
10605 Lockset
Latchbolt operated by lever both sides,
except when locked out.
Key both sides operates latchbolt when
both levers are locked out.
Deadlock actuator.
• 10605E: Both levers are locked, except when power is applied.
• 10605EP: Both levers are unlocked, except when power is applied.
10606 Lockset
Latchbolt operated by lever inside,
except when locked out.
Key outside operates latchbolt.
Lever outside always rigid.
• Dead lock actuator.
• 10606E: Inside lever is locked, except when power is applied.
• 10606EP: Inside lever is unlocked, except when power is applied.
B18
Revised 3/09
P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211