Southern Folger 50HBM User Manual

FA Rev. 02-10 A9
For more information, please call 210.533.1231.
Description______________
Series 50HBM Deadlatches are lever tumbler, motor-operated locks for sliding doors, utilizing hookbolts. Specify keying as follows:
51 Keyed case side 52 Keyed cover side 56 Keyed both sides
Applications_____________
Jamb-mounted 50HBM locks should be specified for maximum security cell, corridor, sallyport, or entrance/egress sliding doors. May be installed within a lock pocket or full height column. They are designed to be part of an electrical locking/unlocking system to provide institutional staff with maximum safety and flexibility of operation.
Operations______________
All 50HBM locks are operated by electric motor. The choice of two motor operations provides a variety of functions:
Full-Rotation Motor (50HBM) with latchback (1):
Unlocks when the motor is energized by a momentary contact switch. Once unlocked, the hookbolt is held mechanically in the raised position until the door is opened. It then returns to normal, lowered position.
Two-Position Motor (50HBMC) without latchback (2):
Same as above, except that the hookbolt is raised and lowered as the motor runs. A door starter should be installed in the track housing to push the door open when the motor reaches the unlocking point.
Testing__________________
50HBM locks have been tested for over 1,000,000 operations.
Standard Features_______
Motor voltage – 120VAC
External mounting – Locks install without cover plate removal. External slotted mounting holes simplify installation and allow for variations in door gap by permitting lateral movement.
Two-piece plug connector –
Simplifies wiring at time of installation and allows pre-wiring at the lock pocket.
Superior durability – Working parts are stainless steel and designed for maximum strength and corrosion resistance.
Hardened hookbolt and deadlock actuator – Zinc plated for corrosion
resistance.
Motor operation – A choice of two operations is available, as shown on following page.
High security – Choice of five or six lever tumbler models. Six tumbler model offers greater pick resistance.
Mechanical unlocking by key –
Once unlocked by key, the hookbolt remains in that position until relocked by key (Models without latchback feature). Key is removable in the unlocked position.
Indication switch – The indication switch monitors the deadlock lever to indicate a deadlocked hookbolt.
Finish – Zinc plated.
FOLGER ADAM ELECTRIC LOCKS
Key: Prison Paracentric Door: Sliding Security
Level: Maximum
50HBM DEADLATCH
A10 Printed in USA FA Rev. 02-10
P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211
Web: www.SouthernFolger.com
Email: info@southernfolger.com
Optional Features________
Motor voltage – 24VDC Lock bolt keepers – Select 50H-4DB
with dust box.
Dimensional Data________
Note: Dimensions are for information and planning purposes only and should not be used as templates.
Specifications_________
Case – 7 and 10 gauge steel.
Cover – 10 gauge HRS.
Hookbolt – .5 inch steel, case hardened and zinc plated.
Deadlock actuator – .5 inch square CRS, hardened and zinc plated.
Deadlock and operator levers –
Stainless steel.
Springs – Stainless steel.
Motor – Synchronous-type gearmotor with brake.
Electrical Characteristics________
Motor (AC) – Synchronous-type gearmotor with brake. Ratings: 120VAC, 60HZ, 1.3 amps at full load.
Motor (DC) – Permanent magnet gearmotor. Ratings: 24VDC, 2.2 amps at full load.
Indication switch – SPDT, UL Listed. Deadlock Ratings: 15 amps at 125 or 250 VAC. Auxiliary Ratings: 10 amps 125 or 250 VAC.
FOLGER ADAM ELECTRIC LOCKS
Key: Prison Paracentric Door: Sliding Security
Level: Maximum
50HBM DEADLATCH
MODEL NO.
OPERATION
DESCRIPTION
LATCHBACK
OPERATION
SWITCHES
INTERLOCK
INDICATION
SWITCH
DEADLOCK
WITH WITHOUT
50HBM-1-01 1 X X
50HBMC-1-04 2 X X
LEGEND
50HB Series Locks
LOCK COVER PLATE TRACK SIDE
56HB
KEYED
BOTH
SIDES
52HB
KEYED TRACK
SIDE
31 HRHL 23
33 HRHL 34
Specify circled swing number when ordering.
This chart shows applicability of functions and features to specific 50HBM models.
For complete details, see How To Specify on the following page.
Loading...
+ 1 hidden pages