FOR GROUPS OF
SLIDING CELL DOORS
Maximum
4110L ELECTRIC
LOCKING SYSTEM
For use where remote electric
unlocking of groups of sliding doors is
required, but door movement can be
by hand at the door. This system also
provides emergency mechanical
unlocking from a control cabinet at the
head of the door line. Doors are
locked at top and bottom in both the
open and closed positions by means of
a concealed vertical lock bar at the
rear jamb of each door. The vertical
lock bar is deadlocked at a third
locking
cover box above the door. Standard
clear door opening widths available are
2'4" to 3'2".
security.
point inside the horizontal
L O C K I N G S Y S T E M S
4110L
ELECTRIC LOCKING
SYSTEM
FUNCTION:
ELECTRIC - Individual switches located
on a remote control panel operate an
electric motor housed in the horizontal
cover box over each door, raising the
vertical lock bar and unlocking the door.
Upon unlocking, the door springs open
a few inches. All door movement is by
hand at the door, which automatically
snap/deadlocks when moved to the fully
closed or fully open position. Individual
lamp indicators on the control panel
show locked/unlocked condition.
A single switch can provide
group unlocking.
MECHANICAL - In the absence of
electrical power, doors may be
individually unlocked with a manual
release tool. Door movement is by
hand and door will relock in either fully
open or closed position.
EMERGENCY GANG RELEASE
an emergency, all doors in a cell line
may be simultaneously unlocked
from a mechanical release cabinet
at the end of the cell line. While in
emergency release mode, doors
will not relock in any position.
- In
TECHNICAL DATA:
• COVER BOX:
1' 0-3/4" H x 7-1/8" D
• COVER BOX MATERIAL:
7 gauge steel plate
• HINGED PANEL:
10 gauge steel
• DOOR ROLLERS:
3" diameter, machined
steel with sealed bearings
• VERTICAL LOCK BAR
DIMENSIONS:
5/8" SQ
of door
•
FINISH: Prime paint
•
DOOR HANGER:
7 gauge steel plate
by full height
•
ELECTRICAL:
Motor:
60 Hz., single phase power,
Inrush: .7A
Locked Rotor Current: .8A
•
WIRE REQUIREMENTS:
When electric operation of the
door is from a remote station, a
minimum of five conductors
(minimum 14 gauge) are
required between the control
point and the door, except for
those models having the letter
“K” (keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.
1/60 HP, 115 VAC,
Revised 3/09
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
B25
FOR GROUPS OF
SLIDING CELL DOORS
Maximum
STANDARD FEATURES:
• Bottom door guide
• Door hanger
• Mechanical release cabinet
• Sloped-front cover box
• Hinged cover panel for maintenance access
• Vertical lock bar assembly
• ASTM F1643 Certified
Horizontal and Vertical Impact Test-Grade 1
• Prime paint finish
OPTIONAL FEATURES:
PILASTER RELEASE– (In lieu of mechanical release
cabinet.) Hip-high paracentric keyed mechanical release
mounted in a full-height pilaster adjacent to the receiving
jamb.
Specify “4110LP-1” keyed one side.
ELECTRIC KEYSWITCH
local electric control switch mounted below mechanical
release mechanism in pilaster.
Specify “4110LPK-1” for paracentric keyed one side.
Specify “4110LPKM-1” for mogul keyed one side.
ELECTRIC HALF CYCLE
tion until it receives relock signal. This function requires the
use of a three position switch. Specify “D.”
HOT DIP GALVANIZED FINISH - Available for external
applications with lift-off cover panel only. Not available with
standard hinged cover panel. Specify “G” when ordering.
Example: 4110LP-1G
REMOTE PANEL LOCK SYSTEM - Remote panel option
is
available with lift-off cover panel only. Not available with
standard hinged cover panel. Specify “RP” when ordering.
Example: 4110LRP
NO LOCK OPEN - Specify “NLO.”
Door does not lock in open position.
MOTOR – Specify “24 VDC.”
Inrush: 1.1A
Locked Rotor Current: 3.4A
FACTORY WIRED CONTROL CABLE
Specify “4110LWC.”
security.
–
Paracentric or mogul keyed
–
Door will not lock in any posi-
L O C K I N G S Y S T E M S
4110L ELECTRIC
LOCKING SYSTEM
4110L SLIDING DOOR SYSTEM
DETAIL A – SLOPED BOX
COVER BOX SECTION
7-1/ 8" deep x 1' – 0- 3/4" t all
cove r box field welde d 1" on 8"
top and b ottom.
DETAIL C – RECEIVER
RECEIVER JAMB SECTIO N
Flus h rec eiver jamb a llows frame
open ing a nd cle ar ope ning to
be the sa me.
DETAIL B – VERTICAL LOCK JAMB BAR
DETAIL D – BOTTOM DOOR GUIDE SECTION
NOTE: Cover box minimum length =
(7"
overtravel) + (2 x clear opening) + 9".
For doors exceeding 300 lbs. and/or greater
than
3’-2” clear opening, contact factory.
B26
Revised 7/12
4110L Shown
Note: Other system configurations and details are available.
Call Customer Service for more information.