FOR INDIVIDUAL
SLIDING DOORS
Maximum
3165LX.b ELECTRIC
LOCKING
The 3165LX.b system includes several versions of a system designed
for locking, unlocking and propelling
sliding doors in safety vestibules, in
dayrooms or in high-traffic corridors.
security.
SYSTEM
L O C K I N G S Y S T E M S
3165LX.b
ELECTRIC LOCKING
SYSTEM
3165LX.b model utilizes an
Each
electric motor to operate the door
through a rack and pinion drive
mechanism. Doors are locked at
top and bottom in both the open
and closed positions by means of
a concealed vertical lock bar at
the rear jamb of the door. The
vertical
third locking point inside the
horizontal
the
opening widths available are 3' 0"
to 4' 6".
lock bar is deadlocked at a
cover box above
door. Standard clear door
FUNCTION:
ELECTRIC - A remote switch
activates
vertical lock bar and propels the
door open or closed.
MECHANICAL - Manual unlocking
is provided for each device. After
being manually released, door
movement is by hand. The door
automatically deadlocks when
moved to the fully open or
closed position.
a motor which raises a
TECHNICAL DATA:
• COVER BOX:
1' 0- 3/4" H x 7-1/2" D
• COVER BOX MATERIAL:
7 gauge steel plate
• HINGED PANEL:
10 gauge steel
• DOOR ROLLERS:
3" diameter, with
sealed bearings
• VERTICAL LOCK BAR
DIMENSIONS:
5/8" SQ by full height
of door
• FINISH: Prime paint
• DOOR HANGER:
7 gauge steel plate
• ELECTRICAL:
Motor: 1/8 HP,115 VAC,
60 Hz., single phase power
Inrush: 1.1A
Running: .9A
Locked Rotor Current: 3.1A
• WIRE REQUIREMENTS:
When electric operation of the
door is from a remote station, a
minimum of five conductors
(minimum 14 gauge) are
required between the control
point and the door, except for
those models having the letter
“K” (keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.
Revised 3/09
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
B23
FOR INDIVIDUAL
SLIDING DOORS
LOCKING SYSTEMS
Maximum security.
STANDARD FEATURES:
• Bottom door guide
• Door hanger
• Local mechanical release at cover box
• Sloped-front cover box
• Hinged cover panel for maintenance access
• Vertical lock bar assembly
• ASTM F1643 Certified
Horizontal and Vertical Impact Test-Grade 1
• Prime paint finish
OPTIONAL FEATURES:
PILASTER RELEASE - Hip-high paracentric keyed
mechanical release mounted in a full-height pilaster adjacent
to the receiving jamb.
Specify “3165LX.bP-1” keyed one side.
Specify “3165LX.bP-2” keyed two sides.
ELECTRIC KEYSWITCH -Paracentric or mogul keyed local electric control switch mounted below mechanical release
mechanism in pilaster.
Specify “3165LX.bPK-1” for paracentric keyed one side.
Specify “3165LX.bPK-2” for paracentric keyed two sides.
Specify “3165LX.bPKM-1” for mogul keyed one side.
Specify “3165LX.bPKM-2” for mogul keyed two sides.
HOT DIP GALVANIZED FINISH - Available for external applications with lift-off cover panel only. Not available with standard
hinged cover panel. Specify ”G” when ordering. Example:
3165LX.b P-1G
DETAIL A – SLOPED BOX
COVER BOX SECTION
7-1/2” Deep x 1’-3/4” tall
cover box field welded 1” on 8”
top and bottom.
DETAIL C – PILASTER P2
3165LX.b ELECTRIC
LOCKING SYSTEM
3165LX.bP-2 SLIDING DOOR SYSTEM
DETAIL B – VERTICAL LOCK JAMB BAR
DETAIL D – BOTTOM DOOR GUIDE SECTION
REMOTE PANEL LOCK SYSTEM - Remote panel option is available with lift-off cover panel only. Not available with standard
hinged cover panel. Specify “RP” when ordering. Example:
3165LX.b
NOTE: Cover box minimum length =
(7" overtravel) + (2 x clear opening) + 9".
For doors exceeding 450 lbs. and/or greater than 4’-6”
clear opening, contact factory.
THREE HOUR FIRE DOOR RATING
AVAILABLE. Standard cover box calculation
does not apply to fire rated door.
B24
RP
Revised 7/12
P-2 PILASTER JAMB SECTION
Pilaster and receiver jamb requires
frame opening to be 7” larger than
clear opening.
3165LX.bPKM-2 Shown
Note: Other system configurations and details are available.
Call Customer Service for more information.