JAMB MOUNTED FOR
SWINGING DOORS
E L E C T R I C L O C K S
Minimum
10300E-1: KEYED ONE SIDE
10300E-2: KEYED BOTH SIDES
and medium security.
APPLICATION:
Minimum and medium security
swinging doors that are to be
unlocked from a remote
location. Jamb mounted.
Door position indicator switch,
door closer and heavy duty
door pull are recommended.
10300E
SOLENOID OPERATED
ELECTRO-MECHANICAL
DEADLATCH
FUNCTION:
ELECTRIC - Remote switch
activates a solenoid which
retracts the latchbolt. Latchbolt
remains retracted until door is
opened approximately 2", then
it releases, automatically
latches and deadlocks when
the door is closed.
MECHANICAL - Latchbolt is
retracted with a builder’s
hardware key at the door, and
remains retracted until door is
opened approximately 2”, then
it releases and automatically
latches and deadlocks when
the door is closed.
UL
Revised 3/09
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
B13
JAMB MOUNTED FOR
SWINGING DOORS
Minimum and medium security.
STANDARD FEATURES:
• Deadlock indication switch
• Mechanical latchback
• Strike with security fasteners
• Faceplate with security fasteners
• Plug connector
• High power, dual coil solenoid
with overload protection device
• Fail secure
• Mounting fasteners
Note #1: 1-11/16” O.D. x 1/8” wall
cold drawn tubes furnished by
hollow metal manufacturer.
OPTIONAL FEATURES:
NO LATCHBACK - Latchbolt
remains retracted as long as
control switch is activated.
Latchbolt extends when power is
removed. Specify “NL.”
E L E C T R I C L O C K S
10300E SOLENOID OPERATED
ELECTRO-MECHANICAL DEADLATCH
O.D. x 1/8”
1-11/16”
wall cold drawn tubes
are required.
See Note 1
NOTE: Drawing for illustration only. Reference template
Swing Chart: Specify circled swing number when ordering.
Frame Preparation
for specific Information.
LOCAL ELECTRIC KEYSWITCH Day key provides local electric
operation and may be disabled
from remote control point. Master
key provides both electric and
mechanical operation.
dual-function enhancement to builder's
cylinder. Specify “LEK.”
Requires
BUILDER’S HARDWARE
CYLINDERS Specify:
• “10300E-1” keyed one side.
• “10300E-2” keyed both sides.
KEY CYLINDER EXTENDER Required whenever lock is keyed
on stop side. Overall frame depth
4" minimum. Specify “KCE.”
Full body rim cylinder required on stop side.
Full body mortise cylinder required on
hinge side.
PROVIDE: (See Fig. 1)
1. Dimension “A”
(overall frame width)
2. Dimension “B”
(edge of frame to centerline of lockbolt)
TECHNICAL DATA
• STANDARD FINISH: US32D
• LOCK BODY: Stainless steel
• FACE PLATE: Stainless steel
• LATCHBOLT: Stainless steel
• DEADLOCK ACTUATOR:
Stainless steel
• ELECTRICAL:
24 VDC, 7.0 amp inrush,
0.6 amp seated
• LOCK SIZE:
10-5/8” H x 1-1/2’ W x 1-3/4” D
• LOCK WEIGHT: 3.6 lbs.
• LATCHBOLT SIZE:
1-5/8" H x 5/8" TK
• LATCHBOLT THROW: 3/4"
• BUILDER’S CYLINDER:
1-5/32” diameter with
standard Yale cam
or equal
• UL Listed for use on
three-hour fire doors.
• ASTM F1577 Certified
Impact Test-Grade 1
B14
Revised 3/09