Southern Folger 10200R User Manual

JAMB MOUNTED FOR SWINGING DOORS
Minimum and medium security.
R E T R O F I T L O C K S
SOUTHERN STEEL 10200R
SOLENOID OPERATED
ELECTRO-MECHANICAL
10200R-1: KEYED ONE SIDE 10200R-2: KEYED BOTH SIDES
APPLICATION:
Direct replacement for Southern Steel 10200 series locks.
Minimum and medium security swinging doors that are to be unlocked from a remote location. Jamb mounted. Door position indicator switch, door closer and heavy duty door pull are recommended.
FUNCTION:
ELECTRIC - Remote switch activates a solenoid which retracts the latchbolt. Latchbolt remains retracted approximately 2 seconds, then it releases, automatically latches and deadlocks when the door is closed.
DEADLATCH REPLACEMENT
MECHANICAL - Latchbolt is retracted with a builder’s hardware key at the door. When released, it automatically latches and deadlocks when the door is closed.
11/12
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
R3
JAMB MOUNTED FOR
A
DAPTING CONTROL MODULE INCLUDED (NOT SHOWN)
DOOR MODIFICATION MAY BE REQUIRED TO FIT LIP ON STRIKE
C
YLINDER PROTECTING R
ING / COLLAR PER CUSTOMER
SWINGING DOORS
Minimum and medium security.
STANDARD FEATURES:
• Deadlock indication switch
• 2 second electronic latchback
• Strike with security fasteners
• Faceplate with security fasteners
• Plug connector
• High power, dual coil solenoid with overload protection. Intermittent coil is protected by module. Second coil is continuous duty.
• Fail secure
• Mounting fasteners
OPTIONAL FEATURES:
FOR ORDERING NEW BUILDER’S HARDWARE CYLINDERS ­Specify:
• “10200R-1” keyed one side.
• “10200R-2” keyed both sides.
R E T R O F I T L O C K S
10200R SOLENOID OPERATED
ELECTRO-MECHANICAL
DEADLATCH REPLACEMENT
Strike is supplied with lip. Modifications for clearance may be required.
NOTE: Drawing for illustration only. Reference template
Swing Chart: Specify circled swing number when ordering.
Frame Preparation
or specific Information.
f
LOCAL ELECTRIC KEYSWITCH – Day key provides local electric operation and may be disabled from remote control point. Master key provides both electric and mechanical operation.
NOTE: New cylinders are required.
This feature is not compatible with existing key cylinders. Rotation is opposite of existing. Specify “LEK” when ordering.
KEY CYLINDER EXTENDER ­Special order - priced on request.
TECHNICAL DATA:
• STANDARD FINISH: US32D
• LOCK BODY: Stainless steel
• FACE PLATE: Stainless steel
• LATCHBOLT: Stainless steel
• DEADLOCK ACTUATOR: Stainless steel
• ELECTRICAL: 24 VDC, 3.6 amp inrush, .32 amp seated*
• LOCK SIZE: 10-5/8" H x 1-1/2" W x 1-13/16" D
• LOCK WEIGHT: 3.3 lbs.
• LATCHBOLT THROW: 3/4"
• BUILDER’S CYLINDER: 1-5/32" diameter with standard Yale cam or equal
*Minimum voltage 22VDC when unlock solenoid energized.
Maximum voltage not greater than 28VDC at any point.
TO ORDER:
• Provide door thickness of 1-3/4" or 2"
• Handing
R4
11/12
P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211