JAMB MOUNTED FOR
SWINGING DOORS
Medium and maximum security.
E L E C T R I C L O C K S
10120AE
SOLENOID OPERATED
ELECTRO-MECHANICAL
10120AE-1: KEYED ONE SIDE
10120AE-2: KEYED BOTH SIDES
APPLICATION:
Medium and maximum security
swinging
unlocked
location.
position
closer
pull
doors that are to be
from a remote
Jamb mounted. Door
indicator switch, door
and heavy duty door
are recommended.
FUNCTION:
ELECTRIC - Remote switch
activates a solenoid which
retracts the latchbolt. Latchbolt
remains retracted until door is
opened approximately 2", then
releases, automatically latches
and deadlocks when the door
is
closed.
DEADLATCH
it
MECHANICAL - Latchbolt is
retracted with a mogul key at
the door, and remains retracted
until door is opened
approximately
releases and automatically
latches and deadlocks when
the door is closed.
Revised 3/09
2", then it
UL
FOR MORE INFORMATION, PLEASE CALL 210-533-1231
B9
JAMB MOUNTED FOR
SWINGING DOORS
Medium and maximum security.
STANDARD FEATURES:
• Deadlock indication switch
• Mechanical latchback
• Strike with security fasteners
• Mogul cylinder (US26D Finish)
• Plug connector
• Continuous duty solenoid
• Fail secure
• Mounting fasteners
OPTIONAL FEATURES:
NO LATCHBACK - Latchbolt remains
retracted as long as control switch is
activated.
power
KNOB FUNCTION - Bolt retracted by
knob on opposite side of mogul
cylinder
MECHANICAL KEY HOLDBACK - Bolt
retracted by key, remains retracted until
manually projected with key. UL Listing for
fire door not available with this function.
Specify “MKH.”
LOCAL ELECTRIC KEYSWITCH - Day
key provides local electric operation and
may be disabled from remote control
point. Master key provides both electric
and mechanical operation. Specify “LEK.”
EMERGENCY EXIT DOOR HOLDBACK Deadbolt retracted by solenoid or by key,
extended by key only (no snap latch feature). When bolt is extended, lock is
dead
available with this function. Specify
“EED.”
NOTE:
KEY CYLINDER EXTENDER - An option
in place of providing a recess in the frame
when keying on the stop side is required.
Available in 3" or 5". 3” extender can be
used on openings up to 6” jamb.
5”
extender can be used on openings up
to 8” jamb. Specify “KCE,” then
extender
upon request.
PROVIDE:(See Fig.1)
1. Dimension “A”
2. Dimension “B”
B10
Latchbolt extends when
is removed. Specify “NL.”
only. Specify “K.”
locked. UL Listing for fire door not
Master keying available.
size. Other lengths available
(overall frame width)
(edge of frame to centerline of lockbolt)
Revised 12/10
E L E C T R I C L O C K S
10120AE SOLENOID OPERATED
ELECTRO-MECHANICAL DEADLATCH
Door Preparation
NOTE: Drawing for illustration only. Reference template
Swing Chart: Specify circled swing number when ordering.
Indicates both mounting / access plate side.
*
TECHNICAL DATA:
• STANDARD FINISH:
Galvanized
• COVER:10 gauge steel plate
• CASE: 10 gauge steel plate
• STRIKE: Stainless steel
•LATCHBOLT:
Stainless steel
• DEADLOCK ACTUATOR:
Stainless steel
• MOGUL CYLINDER:
US26D
• MOGUL KEYS:
Nickel Silver
• PIN TUMBLERS:
Combination nickel silver
and stainless steel,
6 tumblers per lock
P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211
Frame Preparation
for specific Information.
• ELECTRICAL: 115 VAC,
1 phase, 60 Hz., 10 amp
inrush, 0.6 amp seated
• LOCK SIZE:
12" H x 5-7/16" W x 3-1/2"D
• LOCK WEIGHT: 19 lbs.
• LATCHBOLT SIZE:
1-1/2" x 3/4"
• LATCHBOLT THROW: 1"
• UL Listed for use on threehour fire doors.
• UL Listed as burglary
resistant.
• ASTM F 1577 Certified
Impact Test-Grade1