Southbend SX-55EC General Manual

4 (2)
A Middleby Company
ELECTRIC TWO COMPARTMENT
CONVECTION STEAMER ON
CABINET BASE
Job Item#
Model
SX-34EC
SX-55EC
Compartments
2
2
Capacity
1-7 Pans
1-10 Pans
Standard Features
- Delime mode power setting
- Deliming port for each generator, which is located on the rear of the unit.
- Split water connections for simple hook up for a treated water system.
- 28” high stainless steel construction cabinet base with operable door for storage.
- Two electric, stainless steel generators operating at 0 psi (0 kPa) with field replaceable element rated at:
SX-34EC - 7.5kW + 10kW SX-55EC - 15 kW + 10kW
CONSTRUCTION SPECIFICATIONS
Southbend Convection Steamer with individual steam generator for each cavity. C-CSA-US Certified and NSF Approved. Model SX-34EC shall have 3 pan capacity on top and 4 pan capacity on bottom. Model SX-55EC shall have 5 pan capacity on top and bottom. The steamer shall be constructed of a satin finish stainless steel #304. The cooking chamber is a one piece all welded, #316 stainless steel with coved corners. The heavy duty door shall have an inner liner of stainless steel with a full perimeter gasket seal, an outer liner of one piece all welded stainless steel, and a positive lock and seal mechanism with spring release. Each compartment shall be provided with removable stainless steel pan supports. A stainless steel drip trough shall be
integrally connected to drain to collect condensate when the doors are opened.
The control housing shall be constructed of stainless steel with a full access removable panel. Each compartment shall have individual controls which include an illuminated three way power switch (ON/OFF/Delime), a pilot ready light, a pilot cooking light, a 60-minute electric timer which sounds an audible signal at the end of the cooking cycle, and solid state generator controls for each generator. Steam flow to the cooking chamber shall be cut off when the door is opened and reactivated when the door is closed.
SX-55EC
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids - less than 60 PPM Total alkalinity - less than 20 PPM Silica - less than 13 PPM Chlorine -less than 1.5 PPM pH Factor -7.0-8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY