Sony Ericsson W760 Equipment List

Equipment List, Electrical
Equipment List, Electrical
Applicable for W760
General................................................................................................................................................................ 2
1
2 Column Definitions............................................................................................................................................. 2
Description Columns ............................................................................................................................................ 2
Process Columns ................................................................................................................................................. 2
3 Repair Equipment............................................................................................................................................... 3
3.1 Repair Equipment orderable from Sony Ericsson...................................................................................3
3.2 Repair Equipment that should be obtained from local Suppliers............................................................ 7
3.3 Lead-free Solder Equipment................................................................................................................. 23
4 Revision History............................................................................................................................................... 25
1211-1566_4 Company Internal
© Sony Ericsson Mobile Communications AB
Equipment List, Electrical
1 General
This document describes the equipment needed, in addition to the equipment listed in the Mechanical Equipment List, to upgrade the applicable product’s software, functional test and to repair the product at an Electrical Repair Level. The first section is equipment that can be purchased from a Sony Ericsson Parts and Tools warehouse. The second section is equipment that must be purchased from other vendors.
2 Column Definitions
Description Columns
Description = The name of the equipment.
Part Number = The Sony Ericsson part number to use when ordering from a Sony Ericsson Parts and Tools warehouse.
Comments = Additional information that helps to specify or clarify the equipment.
Picture
Process Columns
These columns show which processes use the equipment. An “X” in a column indicates that the equipment must be used, and a “Z” in a column indicates that the use of that equipment is optional.
Customization: Equipment necessary to perform a Customization/Activation.
Go/No Go test: Equipment necessary for Go/No Go testing. Calibration with SERP: Equipment necessary to perform a calibration with SERP. NOTE: Calibration can only be done by authorized repair centers. Repair: Equipment necessary for replacing soldered components.
1211-1566_4 Company Internal
© Sony Ericsson Mobile Communications AB
2(25)
Equipment List, Electrical
3 Repair Equipment
Some of the required equipment will be orderable from Sony Ericsson and some equipment has to be sourced locally. The following sections are structured based on whether equipment is obtained from Sony Ericsson or from a local supplier.
3.1 Repair Equipment orderable from Sony Ericsson
Go/No Go Test
Description Part Number Comments Picture
Sony Ericsson Programming Interface (SEPI)
LTN 214 1484 The Sony Ericsson
Programming Interface (SEPI) is used in conjunction with the SEPI interface cable, the USB computer cable and battery charger to perform calibration on this product.
Customization
X
SERP
Calibration in
Repair
Sony Ericsson Programming Interface (SEPI) cable
1211-1566_4 Company Internal
KRY 101 1119/1 A battery charger needs to
© Sony Ericsson Mobile Communications AB
be connected to this cable during calibration. (GSM Calibration only)
X
3(25)
Equipment List, Electrical
Go/No Go Test
Customization
SERP
Calibration in
Repair
Description Part Number Comments Picture
Service Tool Test Interface
Applicable for W760 only
RF Cable RPM 119 855
1206-9888 W760 only
Necessary for WCDMA Calibration. To be used with the 4921 Shield box Enclosure or any other Shield box that meets the minimum requirements stated in the Electrical Installation Instructions. The Service Tool Test Interface has two parts, one for the inside and one for the outside of the Shield box.
X
RF Cable Short
Applicable for W760 only
1211-1566_4 Company Internal
RPM 119 891 W760 only
© Sony Ericsson Mobile Communications AB
The Short RF Cable is used to connect from the Shield box plate to the Phone.
X X
Z X
4(25)
Equipment List, Electrical
Go/No Go Test
Customization
SERP
Calibration in
Repair
Description Part Number Comments Picture
Dummy Battery
Rework Fixture for PCB LTD 260 273 Used to hold the PCB during
1208-5627 If using the Dummy Battery
to power the handset during the GNG Test or Calibration routine, you must use a high quality DC source.
repair.
Z Z Z
X
RF Probe
1211-1566_4 Company Internal
RPM 119 0201 Used together with the RF
Holder and RF Cable.
Z X
5(25)
© Sony Ericsson Mobile Communications AB
Equipment List, Electrical
Go/No Go Test
Customization
SERP
Calibration in
Repair
Description Part Number Comments Picture
RF Holder 1207-9048 Used together with the RF
Probe and RF Cable
Z X
USB Activation Dongle NTZ 112 1071 Used for Activation in Emma
NOTE: cannot be ordered via the standard ordering process, To order contact your Regional Represenitive
X
DCU-65/USB Cable RPM 131 12 This cable is needed for
1211-1566_4 Company Internal
© Sony Ericsson Mobile Communications AB
loading ITP software and customization/activation.
X
6(25)
Equipment List, Electrical
3.2 Repair Equipment that should be obtained from local Suppliers
Description Comments
RF Shield Package
Rohde&Schwarz RF Shield Package
CMU-Z10 – Antenna Coupler (Partnr: 1150.0801.10)
CMU-Z11 – RF Shield Cover (Partnr. 1150.1008.02)
Using an RF shield package is one of the options for testing the applicable product(s). Testing of the applicable product(s) can also be performed by using the combination of an RF Probe and an RF cable.
Spare parts for mobile phone fixation for R&S CMU­Z10 are available for purchase from Rohde&Schwarz:
Grid Positioning Plate – 1158.9789.00
L-shaped bracket – 1158.9808.00
Stabilizing pieces – 1158.9820.00
NOTE: The Rohde & Schwarz package will require the use of a precision N-type male to SMA female RF adapter to mate with the SEMC RF cable.
NOTE: If you are using a different RF Shield Package than Rohde & Schwartz, special attenuation factors for Go/No-Go test are required.
Customization
Go/No Go Test
Z
SERP
Calibration in
Repair
1211-1566_4 Company Internal
7(25)
© Sony Ericsson Mobile Communications AB
Equipment List, Electrical
Customization
Go/No Go Test
Calibration in
SERP
Description Comments
RF adapter for RF shield box
The adapter for a Rohde & Schwarz Shield box must be a precision N­type male to SMA female adapter.
Willtek 4921 Shield Enclosure
With modified rear panel and N terminator
248718 (Wiltek Part number) Applicable for W760 only
Modified rear panel and N terminator Willtek
300872 (Wiltek Part number)
Applicable for W760 only Battery Charger (Standard SEMC charger applicable for W760)
This adapter is used to connect the RF shield box to the RF cable and is only required if a shield package is going to be used for testing.
Recommended source:
Pasternack Enterprises – (949) 261-1920 or
www.pasternack.com
Part number: PE9430
W760 only
Used for WCDMA or GSM Calibration. A Service Tool Test Interface (1206-9888) is also required.
W760 only
Used with existing Willtek Shield boxes Replace rear panel with modified rear panel and place N terminator on RF connection. Remove RF coupler. A Service Tool Test Interface (1206-9888) is also required.
The battery charger needs to be connected to the Sony Ericsson Programming Interface Cable during calibration. Also used for Charger Test.
Z
X
X
X
Repair
1211-1566_4 Company Internal