SONY Texas Instruments Service Manual

SA-WM500
SERVICE MANUAL
Ver 1.2 2004.09

SPECIFICATIONS

AUDIO POWER SPECIFICATIONS
POWER OUTPUT AND TOTAL HARMONIC DISTORTION:
With 6 ohm loads, from 20 – 200 Hz; rated 150 watts, minimum RMS power, with no more than 0.7 % total harmonic distortion from 250 milliwatts to rated output.
System
Type
Active Subwoofer (magnetically shielded design)
Speaker unit
Woofer: 30 cm dia. (12 in.), cone type
Amplifier section
Continuous RMS output : (0.7%) 150W
Reproduction frequency range
20 Hz – 200 Hz
High frequency cut-off frequency
50 Hz – 200 Hz
Phase selector
NORMAL, REVERSE
US Model
Canadian Model
AEP Model
UK Model
E Model
Australian Model
General
Power requirements
USA and Canada models: 120 V AC, 60 Hz AEP, UK, MY, SP models: 230 V AC, 50/60 Hz AUS model : 240V AC, 50/60 Hz TW model : 110 V AC, 60Hz
Power consumption
120 W
Dimensions
Approx. 360 x 425 x 412 mm (14 1 / 4 x 16 3 / 4 x 16 1 / 4 in.) (w/h/d)
Mass
18 kg (39.6 lb 1oz)
Supplied accessories
Foot pads (4) Audio connecting cord (1 phono – 1 phono), 2 m (6 ft 6 1 / 2 in.) (1) Speaker cords, 2.5 m (8 ft 2 1 / 2 in.) (2)
Design and specifications are subject to change without notice.
Inputs
Input jacks
LINE IN: input pin jack SPEAKER IN: input terminals
Output jacks
LINE OUT: output pin jack SPEAKER OUT: output terminals
2004I02-1
© 2004.09
Sony Corporation
Audio Group
Published by Sony Engineering Corporation
ACTIVE SUBWOOFER
SA-WM500
SAFETY CHECK-OUT
(US model)
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below.
LEAKAGE
The AC leakage from any exposed metal part to earth Ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampers). Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A)
TABLE OF CONTENTS
Specifications ........................................................................... 1
1. GENERAL ...................................................................... 3
2. DIAGRAMS
2-1. Circuit Boards Location ............................................. 4
2-2. Printed Wiring Boards ................................................ 5
2-3. Schematic Diagram ..................................................... 6
3. EXPLODED VIEWS
3-1. Main Section ............................................................... 7
4. ELECTRICAL PARTS LIST..................................... 8
To Exposed Metal Parts on Set
0.15µF
1.5k
Earth Ground
AC voltmeter (0.75V)
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB­LISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
2
• Location of controls
POWER
SECTION 1

GENERAL

POWER SAVE
AUTO
OFF
LEVEL
SA-WM500
This section is extracted from instruction manual.
PHASE
CUT OFF FREQ
REVERSENORMAL
POWER POWER indicator
MIN MAX
50Hz
200Hz
CUT OFF FREQLEVEL PHASE
3
SA-WM500
d
Ver 1.1 2003.06
SECTION 2

DIAGRAMS

THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS. (In addition to this, the necessary note is printed in each block.)
For Schematic Diagrams.
For Printed Wiring Boards. Note :
X : parts extracted from the component side.
x : parts extracted from the conductor side.
: Pattern from the side which enables seeing.
Note:
• All capacitors are in µF unless otherwise noted. pF: µµF 50 WV or less are not indicated except for electrolytics and tantalums.
• All resistors are in and 1/
C : panel designation.
Note:
The components identi­fied by mark 0 or dotted line with mark 0 are criti- cal for safety. Replace only with part number specified.
A : B+ Line.
B : B– Line.
•Voltages are dc with respect to ground under no-signal conditions.
• no mark : Power on
•Voltages are taken with a VOM (Input impedance 10 MΩ). Voltage variations may be noted due to normal production tolerances.
• Signal path. F : AUDIO
• Abbreviation CND : Canadian model MY : Malaysia model SP : Singapore model AUS : Australian model TW : Taiwan model
4
W or less unless otherwise specified.
Note:
Les composants identifiés par une marque 0 sont critiques pour la sécurité. Ne les remplacer que par une piéce portant le numéro spécifié.

2-1. CIRCUIT BOARDS LOCATION

CONTROL board
MAIN board
POWER AMP boar
POWER SUPPLY board
LED board
POWER SWITCH board
4