the older chassis type that requires H stat convergence (CRT
the older chassis type that requires H stat convergence (CRT
TSS Logs for Sony Television Products
BRAND
Unit has an open R789 a 18 meg 1/2 watt resistor for the
Horizontal static convergence. The tech will have to make a
resistor out of 3, 6.2 meg resistors.
Suggest tech look for R789 and see if it is open It is on the
on "C" board. It The value is around 10 meg. There are two
different chassis and CRTs used for this model. If they have
board has H stat control) they need to order the older CRT
as per the manual. If newer type (No H stat) then the new
CRT as per Service Manual supplement -1 is needed. CRT
8-733-743-05 The H Stat is done using the Yoke ring
magnets. I have attached the two Service Manual
supplements, and the SB325R1.
Suggest tech look for R789 and see if it is open It is on the
on "C" board. It The value is around 10 meg. There are two
different chassis and CRTs used for this model. If they have
KV32XBR45AA-1CONVERGENCE
Sony
KV32XBR45AA-1CONVERGENCE
Sony
KV32XBR45 convergence is way off in the
horizontal direction
KV32XBR45 Unit has convergence of all vertical
lines are displace horizontally. Tech replaced the
CRT without authorization. This did not solve the
symptom
KV32XBR45 Unit has sever Horizontal static
KV32XBR45AA-1CONVERGENCE
Sony
convergence error. TV cae to us from another
shop where the CRT and flyback was replaced.
Customer call us for secont opinion.
board has H stat control) I have attached the two Service
Manual supplements, and the SB325R1. However none of
them have show this resistor. We were able to install a
resistor in this unit that was a two 10 megs in series.
Trimming the value by adding another 10 meg in parallel
with one of the other 10 megs. we were able to converge the
set. Original part was not available.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
the older chassis type that requires H stat convergence (CRT
board has H stat control) they need to order the older CRT as
Unit is trying to constantly adjust the vertical height
BRAND
R789 open H-state not operational. What I'm finding is a
resistor that appears to be open on this "C" board It is R789
The value cannot be read nor is it listed in the ESI software
KV32XBR45AA-1CONVERGENCE
Sony
KV32XBR45AA-1CONVERGENCE
Sony
KV32TS46AA-1dead
Sony
KV32XBR45AA-1GEOMETRY
SONY
Unit has mis-convergence of red and blue vertical
lines. They are displace horizontally. Tech
replaced the CRT without correcting the symptom.
Unit has nis-convergence of red & blue vertical
lines which are displaced horizontally. Tech
replaced the CRT. This did not solve the problem.
Unit was dead. has shorted horizontal output and
shorted Q601, & Q602 components in power
supply replaced. After replacement unit will turn on
but still has no secondary voltage output of power
transformer. All relays click but no high voltage.
Has sound.
and horizontal size intermittently.
parts list. Trying another value from 10 to 20 megohms. This
resistor is in the ground return of the H-stat resistor that is
installed in the CRT. Tech needs to try different values to try
and make this set converge horizontally. This TV converged
with a 10 megohm resistor.
Suggest tech look for R789 and see if it is open It is on the
on "C" board. The value is around 10 meg. There are two
different chassis and CRTs used for this model. If they have
per the manual. If newer type (No H stat) then the new CRT
as per Service Manual supplement -1 is needed. CRT 8733-743-05 The H Stat is done using the Yoke ring magnets.
Tech needs to check the condition or RY602. RY602 is the
switching relay that turn on and off the set. The relay is
"HOT" switched. In other words one side of the relay is
connected to power oscillator output that runs nearly 350
vac Peak to Peak at 90Khz. Once the relay is closed this
energy is placed across the power output transformer and
provides the drive necessary to produce the B+.Measuring
the input voltage of the relay to "HOT' ground found it to be
150 volts DC mode. But on the other side of relay we has 3
volts DC mode. Unit has defective RY602 relay.
When monitoring the E/W Pin output of the M board the
signal was very instable. It was decided to replace IC351 the
Jungle IC. This corrected the trouble.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
current there shall be about 1 volt on each collector. With the
connected or not. Tech needs to short Q771(E&B) and see if
KV32XBR250
in the 8 mm VCR, this close proximity to the TV, and the lack
BRAND
Sony AA-1 chassis. Unit no high voltage or sound.
KV32TW77AA-1No high voltage
Sony
KV32XBR37AA-1NO RASTER
Sony
KV32XBR85AA-1NO RASTER
Sony
AA-1Noise Video
Sony
RY602 latched at turn on. Tech replaced the
flyback and Q601, Q602, VDR601, VDR602,
VDR603 & R607. After theses components were
replaced the unit still did not produce secondary
B+. Only 3 volts on the collector of the Horizontal
output.
KV32XBR37 serial 80139945. Unit has no raster.
Has sound, CRT filaments, and high voltage. Led
in front is flashing
KV32XBR85 Unit has no raster. Has sound and
weak OSD. Stand-by light is not flashing.
Sony KV32XBR50 This customer has a Goldstar
8mm/VHS dual deck VCR located under this
television on the built in shelf. When customer
uses the 8mm deck the playback of the tape has
corrupted audio, and poor tracking performance
when played back on this television
Inspected the Power oscillator and discovered that it was
running and producing 167 volts DC at the input side of
RY602, but a <13 volts on the low side. Jumping RY602
restored High voltage. Unit had a bad RY602 relay in the
power supply.
Tech may have a IK failure. When bringing up the G2 the
raster will appear with full vertical sweep and a purple
screen. Not much green. Tech needs to look at the IK buffer
collectors on Q771, Q772, & Q773. Normally with beam
CRT Socket removed all collectors must drop to "0" volts.
Q771 did not. It was 1.2 volts regardless if the tube was
the collector will drop. It did not. TV will need a replacement
Q771. Replacement cured the symptom.
Unit appears to have a normal IK feed back to the jungle IC.
Screen voltages are 670 vdc and the cathode is running at
180 vdc. Unit looks like a defective Jungle IC. Replacing the
Jungle IC corected the symptom.
The design of the 8mm format is significantly different from
that of the VHS. The 8MM format does not have any
stationary heads and completely relies on the signals from
the rotary video heads on drum. 4 ATF (Auto Tracking Fix)
carriers are recorded on to the tape. Apparently the shielding
of shielding in the Sony TV caused the corruption of the 4
ATF signals. Placing the VCR on the bottom shelf of the TV
cabinet corrected the symptom.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
Tech needs to look into the Data & Clock lines of the chassis.
function RMY102 remote is being used. The menu
selection of any of these are tried nothing happens.
codes are within normal values. Suggest the tech replace the
horizontal output transistor is normal. No shorts can be found
volts. Transistor is in cut off. Bases and emitter are the same
BRAND
KV36FV15AA-1RASTER
Sony
KV32TW67AA-1remote
Sony
KV32XBR35AA-1shut down
Sony
KV32V16AA-1shutdown
Sony
KV32XBR45AA-1WEAK VIDEO
Sony
KV36FV15 Unit will turn on with the front panel
control but the set will not develop raster or sound.
The high voltage will turn but no raster. After 3
minutes the raster and sound will appear
KV32TW67 serial 70040800 Remote does not
displays when in the "menu" button on the remote
is pressed. We are able to highlight each area of
the menus selection which are the "Video, Timer,
Setup, and closed caption" choices. But when
In the service mode Service menu the service
menus comes up with AFC as the first selection.
However the binary number (1000) displayed
under the word "Service" keeps changing from
1000 to 1100) randomly
Unit will shut down each time the Remote
headphones circuit is turned on.
KV32V16 serial 7089163 Unit will not stay on.
Goes into shut down immediately after turn on
Sony KV32XBR45 Unit has a very faint picture But
the OSD is fine. Problem shows up in the tuner
and video input mode. Tech ordered Q401 but did
not correct the symptom
These lines must be 5 volts peak to peak and have a typical
word length of 1000 milli seconds. Tech discovered the SDA
pulses were 3.3 volts peak to peak whereas the CLK pulses
were at 5 volts. Tech had to isolate each load on the SDA
line and found the PIP tuner was responsible for loading
down the DATA line.
The remote has been changed without effecting the
symptom.. This appears to be a system control failure. All ID
following components IC101 and IC102 are 8-752-856-00
and 8-759-280-74. The components correct the symptom.
Unit has an intermittent short to ground on the IR12 volt line
located at the output of IC202(3-4) located on the "A" board.
This short was caused by a solder splace on that circuit
. When HV comes up the signal at the Collector of the
in the power supply. PM501(1-810-061-21) & IC601(1-810477-11). PM501 was to culprit in this case.
There is video at the base of Q401 but not at the emitter.
Q401 measures 9 volts on all elements. Base must be 4.5
9 volts. Unit has open R617 a 680 ohm resistor.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
it was less than .015 volts measured at the customers ground
KV32V25 serial 7036251. Unit has an arcing inside
must be there in order for the set to have any vertical sweep.
BRAND
KV32S40AA-2A.C Hum
Sony
KV27V10AA-2AC leakage claim
Sony
KV32V25AA-2arcing
Sony
KV32V26AA-2arcing
Sony
KV35V76AA-2ARCINGKV35V75 CRT is arcing in the neckThe CRT is bad.
ny
So
KV35XBR48AA-2ARCING
Sony
KV32S40 serial 9028282 that has a low level
audio hum in the video input or tuner mode.
Looked in the FPR on web site but could fine
nothing on the subject. The hum is at 60 Hertz
KV27V10 serial 7104657. When the CATV rep
was out a few days ago he plugged in the set in to
wall and when the prongs made contact with the
AC wall outlet a small spark was seen. The CATV
rep exclaimed, "The television is a fire hazard,
and you need to call for service!" He left the set
unplugged and we went out on this day.
the flyback transformer. Tech replaced the
transformer now the unit has a bright band at the
top of the screen. The tech replaced the jungle "IC
without effecting the symptom
KV32V26 serial 8019814. Arcing in the neck off
CRT
KV35XBR48 serial 9014229. TUBE ARCING IN
THE NECK
The hum is a result of magnetic flux from the vertical
deflection yoke. The 60 hz is radiating into the low level
audio circuits through inductive pick up from lead dress and
ground loops. To minimize these Remove JW086 and
JW1007.Add 22AWG wire from JW270 to ground side of
R477. This wire should be on the top side of the A-board and
routed to following the audio signal lines from IC1401 (audio
Our tech plugged in the set and found the set did have a
spark as soon as the set was plugged in the AC outlet. This
is perfectly normal because this chassis has to fully charge 2
820 mfd electrolytics in a voltage doubler configuration. This
causes a tremendous amount of in rush current that may
draw several amperes until the filters are charges up. This
will cause a contact arc the moment the set is connected to
the AC line. This set poses no more fire hazard than any
other electrical device that plugs into the AC outlet. We also
performed an A.C leakage test on the chassis and found that
connection and neutral.
Tech noticed the +15 volt source was lower than expected. It
was only 10 volts. It is not unusual. The voltage is normally
12 volts. What the tech was missing is the -15. This voltage
D530 was shorted and open R536 the 0.47 ohm current
Tech will need replacement CRT A80JYV51X
unit will need CRT A89LJT80XZ
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
Audio level adjustments will not increase in a linear
put to the input. It can be seen with an oscilloscope on one of
Tuner/IF/MTS decoder assembly. Replacement corrected the
BRAND
A new microprocessor is available for this unit. It is part
KV27V65AA-2AUDIO
Sony
KV27S45AA-2AUDIO
Sony
KV32S65AA-2audio
Sony
KV27S20AA-2Audio
Sony
KV27S36AA-2audio
Sony
fashion, instead the audio will increase rapidly in
the first 1/3 of the bar graph.
KV27S45 serial 8046950 Unit has a very rapid
change in volume when increasing the level from
minimum to 4 notches above minimum
KV32S65. Serial # 8014575. Sound and picture is
fine but when the fixed or variable audio out is
connected to an external audio amp and the set is
muted a loud pop is heard in the right channel.
Sony KV27S20. Unit has a low pitch whine in the
left audio channel.
Sony KV27S36. Unit has choppy SAP audio.
Stereo 0.K.
number T-998-600-32. It replaces the original IC001 which
was M37273MF-251
Tech needs to add a resistor in parallel with R432 to
effectively reduce the value of R432. This changes the
voltage divider ratio to the volume control circuit and makes
the volume circuit more linear in operation.
I had the tech try to measure if there was any DC voltages
that resided on the Variable audio output connectors. There
was "4.5" volts on the Right channel and "0" volts on the left
channel. When the "Mute" transistors on the variable line
triggered they pulled both lines to ground. When the external
amp was connected to this circuit the input capacitor for the
right channel charged with this 4.5 volts. We still had audio
on this line even though it was at a 4.5 vdc potential. But
when the Sony muted, the input capacitor inside the Big
External amp discharged and caused a tremendous pop.
C172 is a .47mfd used to decoupling the audio from IC101
the Variable audio control IC. This capacitor had 4.5 vdc on
each leg measured to ground. Removing the capacitor and
measuring the DC resistance across the cap measured 175
ohms. Replacement of the capacitor corrected the symptom.
Problem is best heard in the video input mode with no signal
the output pins of IC1401 but not on the input. Part number
is 8-759-369-39. IC1401 corrected the trouble.
All SAP, Stereo, and mono functions come from the Tuner
assembly and nowhere else. If a problem exists for the
S.A.P. feature all circuitry relating to the feature is replaced
when the tuner assembly is replaced. Recommend the
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
receiver. VCR and over air signals have solid color
BRAND
KV27V65AA-2audio
Sony
KV35XBR35AA-2B&W Tracking
Sony
KV27S22AA-2BRIGHT RASTER
Sony
KV35S26AA-2CHROMA
Sony
KV35S26AA-2chroma
Sony
Sony KV27V65 Sound does not ramp up correctly.
Seems to get very loud as soon as the volume
gets higher in a very short time
KV35XBR35. Unit has color temperature error in
the YUV input mode only
KV27S22 serial # 8102548. Unit goes to a bright
blue screen with retrace lines then shuts down.
KV35S26 Unit has the tint phase shift and color
lock up problems only on the Hughs satellite
lock up.
KV35S36. Unit has random chroma phase
shifting. The tint will vary radically. NTSC color
bars are not stable. "Barber Polling" effect of
colors on bars.
I had tech get into the ID codes and reset ID2 from 239 to
175 and ID 4 from 130 to 194. Then initialize the EPROM .
Set returned to normal operation
According to Sony tech support there is no adjustment for
this input. Refer this customer to Sony customer affairs.
Unit has a defective CRT. When unit is able to turn back on
again the set will sometimes be in the video input mode.
This symptom acts like it is a problem with the satellite
receiver. Inside the satellite receiver there is a NTSC
encoder which injects the 3.579547 MHz color oscillator
signal in the video. If this oscillator is too far off frequency it
will not phase lock with the 3.579545 MHz in the television.
This is a software problem with the Satalite receiver. A
software download will be available to all receivers in Late
Suggest the tech look very close to the connection s to
IC351(4) This the Chroma AFDC filter. Components R354,
C355, C355 are in the AFCFIL circuit. It is possible the
trouble is a Jungle IC but Before replacing it is
recommended to check the aforementioned components
first. Note: when checking the components it was found that
C366 has glue touching each end of the device. The glue
effectively changed the value of the device. Cleaning the
glue and reinstalling the device corrected the problem.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
input labeled VHF/UHF the set will picture will lose
and a satellite dish. The CATV is being feed into the RF input
Original CPU CXP85640-005S The new device is CXP85640-
BRAND
The customer is using two different RF sources. Cable TV
KV35XBR20
Sony
Sony
Sony
Sony
Sony
Sony
0
KV35XBR48AA-2CHROMA
KV27S20AA-2
KV27V20AA-2
KV27V20AA-2
KV35V75AA-2
AA-2CHROMA
CLOSED
CAPTION
CLOSED
CAPTION
CLOSED
CAPTION
CLOSED
CAPTION
KV36XBR200 When the customer is using the RF
chroma intermittently. But when using the AUX
input the chroma is solid and does not vary. The
tech replaced the RF switch without effecting the
symptom.
Unit is connected in to component video input
mode through a DVD player. The picture has a
predominately green picture
KV27S20 serial # 7042141 Unit will not operate in
the closed caption mode if using the DVD player.
However if the television operates in the tuner
mode for over the air telecasts, closed caption
works fine.
KV27V20 8015729 No closed caption on premium
channels
KV27V20 serial 8015729 Unit does not have
closed caption on premium channels
KV35V75 9006691 Unit does not have closed
caption on premium channels
labeled VHF/UHF and the satellite is fed into the AUX input.
It appears the tuner does not correct the AFT when two
different RF sources are used. The channel will has to be
readdressed again for any AFT correction to occur. Suggest
the customer used the satellite in the S-video and separate
video input mode. In his present configuration the customer
is loosing all stereo reception, and all high frequency detail
over. This corrected the symptom.
When operating a different DVD player the symptom is the
same. There is no cure to this phenomin from Sony at this
time
Tech needs to order IC001= T-935-001-61 per bulletin
R329R1. After replacement the tech will need to enter the
tech menu and select "CRIW" and change it from 15 to 3.
Also check the "LBLK" must be 7, "RBLK" must be 7 and
"HBSWO" must be 0. At this point save the new data and
The tech needs to set the ID codes to the following ID0=25,
ID1=19, ID2=47, ID3=0, ID4=27, ID5=3, ID6=0, ID7=0. If
these are OK then the tech will need to replace the IC001
with an upgraded version per bulletin 329R1 Original generic
# is CXP85640-004S, the new generic # is CXP856P40S-1
part number T-935-001-61
See Bulletin 329R Original CPU CXP85640-005S The new
device is CXP85640-006S
006S CPU was replaced and did not correct the symptom.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
teletext 1 and 2 to the "Minus" option this effectively shuts off
Resistor R354 was not soldered in correctly. The resistor is in
BRAND
The tech needs to set the ID codes to the following ID0=25,
ID1=19, ID2=47, ID3=0, ID4=27, ID5=3, ID6=0, ID7=0. If
KV27V20AA-2
Sony
KV27V20AA-2
Sony
CLOSED
CAPTION
CLOSED
CAPTION
No closed caption on premium channels
Sony KV27V20.unit has intermittent symptom of
closed caption coming up on screen. Cust claims
they cannot turn off the closed caption option.
these are OK then the tech will need to replace the IC001
with an upgraded version per bulletin 329R1 Original generic
# is CXP85640-004S, the new generic # is CXP856P40S-1
part number T-935-001-61
Unable to see any problem with circuitry, and ID codes are
correct. All appears normal. Setting all CC1 ~ CC4 and
the closes caption feature. Instruct customer to operation od
Sony KV32V15 serial 9013716 AA-2D Unit has
horizontal banding of purple and red at top of
KV32V15AA-2color banding
Sony
KV27V22AA-2CONVERGENCE
Sony
screen. If the color was reduced the banding would
disappear. Color bar did not have a normal
appearance
KV27V22 serial # 8051260 will not converge the
bottom red green or blue horizontal lines
the Color AFC circuitry. It had a .15 ms ripple on it causing a
phase shift in the chroma in the first 4 to 5 inches on the
picture. Problem was caused by a glue used to secure the
surface mounted resistor. The glue prevented a good
connection of the resistor to the pad. Cleaning the glue away
and resoldering corrected the symptom.
Unit has over 6 permaloy magnetic on the CRT bell in the
area of the bottom of the yoke. This is not a good sign. It is
also a rebuilt CRT. We are not going to place more
Permaloy strips on this CRT. It needs replacement.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
hours continuously. It ran fine. But 6 hours after the CRT was
Q512 was shorted. L511 is burned and needs to be
BRAND
I never recommend that after replacing these components in
the power supply that the set have full line voltage applied
to it. The odds are very high the new components will be
instantly. Suggested the tech use a variac to do these tests.
This power supply should start running at 10 vac as a line
KV32S40AA-2dead
Sony
KV32S40AA-2dead
Sony
KV32V40AA-2dead
Sony
KV32S40 serial 8001469. Unit had the power
supply IC601 shorted and open R607. Tech
replaced these components and it shorted out
again at the instant the television is plugged in.
KV32S40 Unit will run for several days then it will
short the horizontal output transistor and destroy
the power supply IC601
KV32V40 Unit was originally dead. Q502 was
replaced. Now set has a sever over scan of
horizontal sweep. Collector of Q512 only 2 volts
changed, along with D504 D503, D502, C511,
C513, and L511.
source. The current should never go above 100 ma during a
no load test. Max 800 ma during a normal load. When
running this power supply at 15 volts the current was surging
to over 200 MA. Checking al the loads on the secondary
found no obvious short circuits. However when checking the
capacitors in the primary we found C610 has internal
resistance of 470K, There should be no internal resistance.
Replaced C610 and restored normal operation. Suggest that
C609, C610, C611, and C612 be automatically replaced
This product was brought into the shop where the set was
operated with the CRT disconnected for approximately 100
connected the Horizontal output and power supply self
destructed again. Unit has defective CRT Suggest the tech
replace the CRT
After replacement of the components the sweep was still
excessive. When using an oscilloscope on the IC351(31) the
E/W pin out we found 6 volts DC, and no 60 HZ parabolic
wave form. If this E/W output pint was touched to ground
through a 270 ohm resistor the picture narrowed up to a an
almost normal width. Product had defective IC351.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
were not making contact to the terminal inside the connector.
transistors lasted 10 minutes and in 1 case 1 week.
disconnected It was determined the power supply, deflection,
decided to change the CRT needs to be replaced. CRT fixed
was open. However the device is connected in the circuit like
removing the defective VDR602 allows the set to turn on and
operate correctly. Tech will need to replace T602 and
BRAND
Checking the Collector of the Horizontal output transistor the
retrace period was running in excess of 20 microseconds not
the traditional 11.5 microseconds. Closed inspection was
found the deflection yoke leads inside the connector were
loose and the crimp for the wire to the horizontal winding
Cleaning the terminal and prepping the connection was
necessary because there was evidence they were burned by
the voltage drop in the poor connection .
KV32XBR48AA-2dead
Sony
KV32XBR48. Originally dead with shorted IC601
converter IC and horizontal output transistor
shorted too. The horizontal drive looked odd, but
this was not the problem.
KV35S26AA-2dead
Sony
KV36FV1AA-2DEAD
Sony
KV35S36 serial 9027801 Unit goes dead after 10
minutes after the power supply was repaired.Q601
& Q602 were not running hot they just shorted.
They were replace 4 times. Each time the
KV36FV1 serial 9029271. Unit is dead. After
talking to customer they explained that they had a
power surge caused by a car hitting a power pole.
After running the television for over 1 hour with the CRT
and horizontal deflection were all working. It was further
the unit.
The set was completely dead. VDR602 was noticeably
burned up. Cutting this device our of the circuit found that it
a metal oxide varistor. It should measure open since it is in
parallel with the A.C. Line. It was discovered that no other
shorted components could be found in the primer of the
power supply. Main line fuse WAS NOT BLOWN! Checking
the raw AC voltage on the AC Line filters T601, and T602
find that we have no AC voltage on the output of T602 but
present on the input side. Isolating the open coil and
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
and the Flyback, but when power was reapplied the
ground caused by a shorted protect diode in the secondary of
explained that they had a power surge caused by a
was open. However the device is connected in the circuit like
removing the defective VDR602 allows the set to turn on and
operate correctly. Tech will need to replace T602 and
BRAND
Checking the Collector of the Horizontal output transistor the
retrace period was running in excess of 20 microseconds not
KV32XBR48AA-2Dead
Sony
KV27V65AA-2Dead
Sony
KV36FV1AA-2Dead
Sony
Originally dead with shorted IC601 converter IC
and horizontal output transistor shorted too.
Unit is Dead Tech replaced the IC601 and R607
set destroyed the power supply again.
Unit is dead. After talking to customer they
car hitting a power pole.
the traditional 11.5 microseconds. Closer inspection found
the deflection yoke leads inside the connector were loose
and the crimp for the wire to the horizontal winding were not
making contact to the terminal inside the connector.
Unit had a blown IC601 and R607. Tech had failed to check
the condition of the Power supply output for the 135 vdc
source.. It was discovered there was a 1.2 ohm short to
the power supply. I cannot stress enough the tech needs to
check all loads on the secondary of the power supply for
shorts, and use a variac to start up all power supplies. All
parts changed earlier are destroyed and need to be replaced
The set was completely dead. VDR602 was noticeably
burned up. Cutting this device our of the circuit found that it
a metal oxide varistor. It should measure open since it is in
parallel with the A.C. Line. It was discovered that no other
shorted components could be found in the primer of the
power supply. Main line fuse WAS NOT BLOWN! Checking
the raw AC voltage on the AC Line filters T601, and T602
find that we have no AC voltage on the output of T602 but
present on the input side. Isolating the open coil and
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
This is caused by the 10 megabit throughput limit of the DSS
BRAND
video compression format MPEG3. In order for the
compression to work correctly the Digitization process only
updates the data that is changing. Background data is not
updated as regularly as the foreground data. Hence when
everything must get updated. But the MAX Data throughput
is finite. the entire video waveform will not be accurately
represented, instead the smaller detailed portions of the
picture will begin to have larger pixels so not to exceed the
Max Data. This is why to the eye the set appears to loose
resolution or picture detail. This is normal.
The set has a dynamic focus error. Tech needs to see if the
Dynamic focus circuitry is running correctly. Also before any
hardware is tested the parameters of HAMP and DCSF
should be adjusted to see if the dynamic focus is effected.
When adjusting these parameters the values get the best
focus when each is mixed out to 60. The focus becomes
poor 2 inches from the left side of the screen and 5 inches
from the right side of the screen.
Tech needs to replace the EPROM……. I002 corrected the
problem
This television is operating within specifications. The
geometry errors should not deviate more than 1/8 of an inch
across the length of the Horizontal line. Horizontal tilt can be
no more than 1/8 of an inch. This television beats this
measurements. There is nothing I can recommend to the
tech to do to improve on the geometry of this receiver.
KV36FV1AA-2FOCUS
Sony
KV36FV1AA-2focus
Sony
KV27S10AA-2GEOMETRY
Sony
KV27V65AA-2GEOMETRY
Sony
KV36FV1 Customer is running the television on a
DSS satellite system. Customer claims the set
looses focus in the picture when there is a lot of
detailed movement.
KV36FV1 serial 9046442 Unit has poor focus on
left and right side of picture
KV27S10 serial 723009 Unit has symptom every
time the set looses power the geometry memory is
lost VPOS, VSIZ, HSIZ. PAMP drop at least 10
points each. When resetting these values and
writing them to memory the they will be erased as
soon as power is removed
KV27V65 serial 8027393 Customer complaint is a
slight geometry error or tilt in the lower right hand
corner of the screen. It causes a symptom of
horizontal lines that are not perfectly straight. In
this case the lines are elevated by at width of 2
horizontal lines.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
not have a pix tilt circuit or rotation on the CRT bell
sweep is reduced by 10 to 15% on the left side and
Monitoring the voltage at the Collector of @Q512 the voltage
running in excess of -7 volts. The voltage on this transistor in
BRAND
Sony
y
Son
SONY
Sony
Sony
KV32S45AA-2GEOMETRY
KV36FV1AA-2GEOMETRY
KV27S25AA-2HIGH VOLTAGE
KV35V36AA-2horizontal
KV36FV1AA-2horizontal
KV32S45 serial 8102913 picture is rotated
clockwise by 1/4 inch. Tech claims this tube does
KV36FV1 serial 9032273 Tech needs yoke
modification for the yoke upgrade.
Unit has no high voltage. LED in front is flashing
on and off after power up.
Unit has a insufficient horizontal sweep. The
2 ~ 5% on the right.
Unit has a severe over scan condition for
horizontal sweep. Tech did not measure any
voltages in the pin amp circuit.
Tech needs to break the bonding of the yoke ant reposition
the yoke.
Gave tech bulletin 387R2 relating to the shoulder roll off
There does not seem to be any horizontal drive to the
Horizontal drive transistor. Defeating the Horizontal output
by removing the collector connection still will not allow
Horizontal drive to appear at IC351(37). This pin is sitting at
nearly 8.5 volts, not the 3 volts it is supposed to be. Also
IC351(38) the HOFF/AFCPIN is at 3.3 volts which is normal.
Unit has a bad IC351 CXA2025AS
When going into the tech set up parameters and adjusting
the HSIZ value the sweep will change to full sweep.
will vary from 27 volts HSIZ set to 22. When HSIZ is set to
48 Q512(C) will drop to 16 volts. The set will have full sweep
but it has a slight foldover condition on the right side of
picture. It is recommended the tech replace the retrace
capacitors C511, & C513 and the Yokes" capacitors C518, &
Tech needs to check on L511, Q512, C513, C511, D502 &
D504. One or more of these are shorted.
Measuring the collector of Q512 tech finds the voltage
Unit has severe over scan of horizontal sweep.
KV32S40AA-2horizontal
Sony
Tech replaced Q512 Shorted and Q511 open all
elements.
inconsistent with the symptom on the screen of a narrow
raster that is hourglass shaped. L511 and Q512 are burning
up. Suggest the tech replace the following additional
components D502, D503, D504, C511, and C513.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
running in excess of -7 volts. The voltage on this transistor in
Monitoring the voltage at the Collector of @Q512 the voltage
BRAND
KV27S20AA-2horizontal lines
Sony
KV32S40AA-2horizontal sweep
Sony
KV35V35AA-2
Sony
KV36FV1AA-2
Sony
KV35V75AA-2
Sony
HORIZONTAL
HORIZONTAL
HORIZONTAL
SWEEP
SWEEP
SWEEP
Sony KV27S20. Black banding across the screen.
Symptom does not appear when playing a tape.
KV32S40 ser 8053998 Unit has sever over scan of
horizontal sweep. Tech replaced Q512 Shorted
and Q511 open all elements.
KV35V36 Product has a insufficient horizontal
sweep. The sweep is reduced by 10 to 15% on the
left side and 2 ~ 5% on the right.
KV36FV1 serial 9023663 Unit has a sever over
scan condition for horizontal sweep. Tech did not
measure any voltages in the pin amp circuit
Unit has shorted L511 and Q512. Tech replaced
these items and they burn out again
Gave tech modification on the KV27S20 to replace C1267
from a .047 to a .47 tantalum capacitor.
Measuring the collector of Q512 tech finds the voltage
inconsistent with the symptom on the screen of a narrow
raster that is hourglass shaped. L511 and Q512 are burning
up. Suggest the tech replace the following additional
components D502, D503, D504, C511, and C513.
When going into the tech set up parameters and adjusting
the HSIZ value the sweep will change to full sweep.
will vary from 27 volts HSIZ set to 22. When HSIZ is set to
48 Q512(C) will drop to 16 volts. The set will have full sweep
but it has a slight foldover condition on the right side of
picture. It is recommended the tech replace the retrace
capacitors C511, & C513 and the Yokes" capacitors C518, &
C515. Tech replaced all of the capacitors and the symptom
Tech needs to check on L511, Q512, C513, C511, D502 &
D504. One or more of these are shorted.
Tech needs to replace D503,D502, D504 and C511, C512
the retrace capacitor along wit the other components.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
The main concern is if the pulses are leaving the main board,
ID6=1, ID7=0 . Write these in memory, then press "8" "Enter"
IN" & "C OUT" on connector CN501(1 & 5). We have chroma
BRAND
I had tech short the CN1761(1, 2, 3, & 6) together. This
should give a perfect black and white picture. But when this
was shorted we had a black and white picture but the picture
KV32S26 Unit has a brighter than normal picture.
KV32S26AA-2Int Raster
Sony
KV27V22AA-2intermittent snow
Sony
KV36FV75AA-2NO AUDIO
Sony
KV27S15AA-2NO CHROMA
Sony
y
KV32XBR48AA-2no chroma PIPSony KV32XBR48. No chroma in PIP X3304 0n PX board not soldered (PIP)
Son
When G2 is lowered the picture blinks on an off.
Tech replaced the flyback and jungle chip with no
changes in symptom
KV27V25 Unit has intermittent snow in the picture
zThe tuner pn# 8-598-340-20 was replaced. Now
the set has a symptom where the remote control
causes the set to enter the video input mode when
the channel is selected. Also the set will enter the
video input mode if the and another brand of
remote that operates a stereo receiver will put the
set into the video input mode.
KV36FV75. Unit has no audio. But also has no
OSD stating "Main" or "Stereo" Main picture is fine.
KV27S15 Unit has no Chroma. Black & white is
OK. Also no Chorma while using the PIP. Sound
and On Screen Display OK. Initializing EPROM
does not change the effect.
still was flashing. Since the jungle IC was already replaced it
was assumed the IK pulses were OK from the jungle chip.
and if the pulses are getting back to pin 27. This flashing
condition indicates the IK feedback pulses are insufficient
some where in this path. Further static check indicated a
shorted zener diode D1792 in the IK buffer path on the CRT
I instructed the tech to enter the tech mode and set the ID
codes...ID0=25, ID1=23, ID2=47, ID3=0, ID4=27,ID5=135,
to initialize. This corrected the problem.
ID codes are 0=25, 1=55, 2=47 3= 0 , 4= 155, 5 =143, 6 =6,
7=0 which is correct. Initializing the EEPOM did not correct
the trouble. Tech will be returning with a Manual
Scoping the first place where the chroma signal can be
readily available is on the PIP module. They are marked "C
going into the PIP board but nothing coming out. Jumping
these pins together with a 1 mfd capacitor caused the color
to return, as long as the capacitor was in place. Unit has bad
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
remove the horizontal output transistor and try starting up the
The horizontal driver has tremendous amount of ringing on it.
BRAND
KV27S25 serial 811908. Unit has no High voltage.
LED in front is flashing on and off after power up.
There does not seem to be any horizontal drive to
the Horizontal drive transistor. Defeating the
KV27S25AA-2
SONY
KV32S25AA-2No Highvoltage
Sony
KV32V25AA-2No Highvoltage
Sony
NO HIGH
VOLTAGE
Horizontal output by removing the collector
connection still will not allow Horizontal drive to
appear at IC351(37). This pin is sitting at nearly
8.5 volts, not the 3 volts it is supposed to be. Also
IC351(38) the HOFF/AFCPIN is at 3.3 volts which
is normal
KV32S25 Unit will not develop high voltage. When
the set is turned on no high voltage appears. The
set has sound and has a flashing light on the front
indicating the set is still in a stand by mode
waiting for IK pulse feed back acknowledgement
from the jungle IC
KV32V25 serial # 7014651. Unit has no high
voltage.
Looks like the tech has a bad IC351 CXA2025AS. A second
Jungle IC corrected the problem.
When monitoring the Horizontal output collector we found
the 140 dropped slightly at turn on. But the Horizontal driver
Q501(C) dropped to 85 and back up to 140. I had the tech to
set again. After power up measure the Q501(C) horizontal
driver transistor. It should be about 85 volts and stayed. This
told us we were looking at a shutdown symptom. Checking
all secondaries we found nothing shorted. Replaced flyback
which corrected trouble.
Does not change if we remove horizontal output transistor.
The transistor has drive has 7 distinct pulses on the base
that go above and below the cut off point of the transistor.
These seven pulses are 1 microsecond in duration and are
grouped in clusters after where the horizontal drive pulses
are supposed to be. If allowed to operate for more than a
minute the horizontal driver transistor Q502 will short C to E.
The product has a bad jungle IC301
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
increased the set has a partial raster but brighter at
BRAND
I had tech check the must haves. The only thing that was not
present was Heater voltage. I had the tech remove the
socket and measure the total resistance of the filament
KV26V36AA-2NO RASTER
Sony
KV27S20AA-2No Raster
Sony
KV32S25AA-2NO RASTER
Sony
KV32S65AA-2No raster
Sony
KV26V36 Unit has no raster. Further checking we
found the set had High voltage and vertical sweep.
Just no filaments.
KV27S20. Unit has no raster. Tech had replaced
CRT but the symptom was not corrected Power
light still flashing indicating the unit is in the stand
by mode
KV32S25 Has no Raster. When the G2 is
the top of the screen then the bottom. Measuring
across the vertical yoke windings we find there is a
voltage of approximately 8 volts. These is sound
and channels can be selected.
KV32S65 serial 8014809. Unit has no Raster.
Sound O.K.. LED on front panel flashing. It also
does have high voltage.
source by measuring the H1 & H2 terminal pins on the "C"
board. It was open. H1 & H2 at the flyback were less than 1
ohm. Checking CN503 found the black wire was loose and
fell out of the connector when unplugged from the main
board. Connector wire would stay in place if reseated.
Pushing connector back in place corrected the trouble.
Open trace on the CRT driver board causing the IK pulses
not to be returned to CN1761(6) not to be fed back into the
jungle chip.
The symptom indicates the set has a vertical deflection
failure but more precisely a power supply failure for the _15
volts source. The tech either has a open R536 = .47 ohm @
or open D530. .
I had tech measure the G2 voltage at the CRT. It was only
54 volts. With the socket disconnected the G2 voltage
returns to 410 volts. Unit has defective CRT. CRT must be
replaced A80JYV52X
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
increased the unit has a non uniform bright screen,
volts (where it should be about 3 volts), and Q561(B) was 0.6
bus. Measuring the SCL & SDA I found the SCL was running
BRAND
Cure: Checking the +12 and -12 volts at IC561(2&4)
respectively are normal. Monitoring Q561( C) it was only 1.7
KV32V40AA-2NO RASTER
Sony
KV20VM20AA-2No Raster
Sony
KV32S22AA-2no raster no sound
Sony
KV32V25AA-2no video
Sony
KV32V40 Unit has no raster. When G2 is
brighter at the top of the screen. The television
has sound.
Sony KV20VM20 Unit has no raster but sound and
OSD are O.K.
KV32 Unit has a horizontal line across center of
the screen. The line is elevated above center by 2
inches. There is no sound too. No LED'S in front
are blinking
KV32V25 Unit has no video when using the front
input jacks. All other inputs are O.K.
volts( where it should be "0" volts).. The voltage at Q562(B)
is always low (0.11volts). By pulling the base Q562(B) high,
with a DMM in the diode check mode, we are able to get full
vertical sweep. It appears there is no, or poor pulse coupling
between the FB pulse U561(3) and Q562(B). A strong pulse
is present at U561(3) when grounding Q561(B). No pulse at
C564(+) Tech needs to replace C564 1mfd @ 50 volts was
Unit did not have any Horizontal blanker pulse to pin 19 of
the Jungle IC. Shorted Z1403 Unit had 60 Peak to Peak at
the "FP" of flyback. At cathode of Z1403 should be 7 volts
peak to peak. Replace diode and restored normal operation.
This symptom is inductive of a problem in the data or clock
at 1 volt peak to peak and the SDA was at 4.97 volts PP. I
had the tech start pulling all of the stand up boards out of the
mother board to isolate the SDA & SCL lines. After the main
tuner was removed the SCL returned to normal. Replacing
the main tuner corrected the trouble.
When tracing the video signal from the front input connector
we find good video on the connector but less than an inch
away from the connector is a coupling capacitor C2233.
Apparently the trace was torn after the video input jack
entered the board. Placing a hard jumper wire from the Jack
to the C2233(-) corrected the fault.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
This television had sever noise resembling black &
waves that are random in size and shapes. This indicated the
KV32XBR60 Unit has narrow picture and hourglass
I asked the tech go through the ID codes for this unit and see
BRAND
Checking the video at the input of the comb filter IC3504(2)
on the rear I/O circuit board. The video is perfect. However
the Luminance out IC3504(9)is broken into pseudo square
KV36FS12AA-2NoiseY video
Sony
KV27S22AA-2
Sony
KV32XBR50AA-2PINCUSHION
Sony
KV35V36AA-2PIP
Sony
Picture
interference
white random lines of varying lengths. No
discernable picture. Noise is in the tuner and video
and modes.
Sony KV27S22. Serial 8126359 the sound is
increased to a 60 to 80% level the CRT will exhibit
an effect on the sides resembling a "water fall"
effect. It disappears if the audio is muted or if the
audio level is dropped down to a lower level.
distortion
KV35V36 Unit has no control over PIP channels.
The PIP only displays the main channel. It will not
change on its own
Combfilter was not working. Further checking discovered the
FSC IC3504(37), which is a 3.58mhz carrier was reduced to
a 60hx pulses. At CN271(15) we found the FSC signal
normal. Problem was an open trace between the connector
CN274(15) and C3578 located inside the combfilter shield
located at coordinates C2 on the UY board.
This symptom is called 'acoustical vibration." It is caused by
the sound energy from the speakers coupling acoustically
through the CRT frame to the Aperture grille inside the CRT.
The vibration causes the aperture grille assembly in the tube
to vibrate. Suggested customer use external speakers
Q505 shorted and R571 open
if they were the correct value. ID3was 10 ID5 was143 &
ID6was 0. These were wrong. The ID codes are supposed to
be from ID0 ~ ID7 = 25, 55, 47, 10, 155, 6, 0. After resetting
the ID codes the set operated the PIP correctly but still
needed to set the PIP chroma phase
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
the first Sony for this trouble. But the symptom was
the Main B+ from the main SMPS. What is turned off is the 9
enclosed oak cabinet (no doors) in a bedroom with tile floors.
Since these pulses are at the top portion of the tube or on the
The "Q" distance has been severely compromised because
No magnets appear to have moved into a position that would
BRAND
This noise is normal due to the fact the set does not shut off
KV32S40 8096389 Customer complaint is when
KV32S40AA-2Power supply chirp
Sony
KV35S40AA-2preglow
Sony
KV27S22AA-2PURITY
Sony
KV27S45AA-2purity
Sony
KV36V15AA-2PURITY
Sony
the set is turned off there is a slight noise " zip"
noise from the flyback transformer that lasts for
about 2/10 of a second. The customer exchanged
also in this TV too. The customer tried two of the
same models, and claimed they did not here this
noise when they heard it at the store.
KV35S40 Unit has preglow at the instant the
television is turned on. ?The preglow shows in the
lower left and right hand corner and stays until the
raster appears.
KV27S22 serial 8091271. After the unit is turned
on and the picture is on there is evidence the
degausser is still running for about 5 seconds after
the picture comes on. There seems to be a 18
second delay before the Degaussing relay
unlatches. There is only a 10 second delay for the
picture to appear after power up.
KV27S45 Serial 8056889 Unit has sever purity
error in the lower right hand corner of the picture
KV36FV15 serial # 9026985 Unit has in the lower
left corner the tube has a sever convergence and
purity error.
volt source from IC642 in the "G" board. As the voltage
decays the there may be a slight phase shift in the horizontal
drive signal as soon as the 9 volts begins to drop. The
reason the customer could not hear this symptom in a store
is due to its acoustics. The store is far noisier and carpeted
walls and floors. In the customers home the set sits in an
One can here a pin drop in this room. This set is operating
This phenomena is normal and is caused by the IK pulses
that are produced at the instant of turn on. Even thought the
cathodes are not completely warmed up there will be a slight
amount of beam current produced by just the IK pulses.
curved funnel portion of the CRT this symptom is common
and is not considered a defect in the CRT.
I don’t know what the latch time is for the Degauser relay. I
thought that it was a bit excessive. But even though the latch
time is excessive the posistor THP601 should increase high
enough in resistance to drop the degaussed current to
minimum levels. The trouble was corrected by replacing the
THP601
the aperture grill has shifted. Unit will need a replacement
this effect. It cannot be adjusted out. It has been determined
the CRT needs replacement.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
When turned on the raster has a dim glow, with the
a uniform brightness where the top of the screen was brighter
The tech replaced the transformer now the unit has
source was not running. I had the tech check R553 a .47 ohm
BRAND
KV27V22 Serial # 8049735 Unit has red screen
KV27V22AA-2RASTER
Sony
with then no raster G2 voltage drops to 3 volts.
Tapping on neck of tube causes the picture to
return to normal. Tech could not duplicate the
trouble again. After this the set ran fine.
CRT.. Due to this symptom and the intermittent nature of the
trouble I suggest that we replace the CRT A68KZJ50X
When raising the G2 voltage it was discovered the CRT had
KV32S20AA-2raster
Sony
KV32V25AA-2raster
Sony
KV27S22AA-2retrace
Sony
KV32S22AA-2retrace
Sony
KV32V25AA-2retrace
Sony
top brighter than the bottom. The Timer LED in
front flashes. Unit has high voltage and sound.
Unit had an arcing inside the flyback transformer.
a bright band at the top of the screen. The tech
replaced the jungle IC without affecting the
symptom
Unit goes to a bright blue screen with retrace lines
then shuts down.
Unit has bright screen with retrace lines then it will
shut down. Measuring the G2 supply finds nearly
420 vdc but the CRT cathodes are running only 55
volts. Disconnecting the CRT socket causes the
cathode source voltage to rise over 180 volts.
Unit has bright screen with retrace lines then shuts
down.
than the rest in the CRT. It was also discovered the -15 was
missing. Tech needs to look at D530 and R537 a 0.47 ohm
resistor.
Tech noticed the +15 volt source was lower than expected. It
was only 10 volts. It is not unusual. The voltage is normally
12 volts. What the tech missed is the -15. This voltage must
be there in order for the set to have any vertical sweep.
Resistor for the -15 volt source from the Flyback was open.
D530 and R537 a 0.47 ohm resistor.
Unit has a defective CRT. When unit is able to turn back on
again the set will sometimes be in the video input mode.
It appears the CRT is loading down the cathode voltages.
Unit will need a replacement CRT.
Measuring the 200 volt B+ at the CRT socket we found the
voltage to be under 126 vdc. This indicated the 200 volt
1/2 watt resistor and it was open. Replaced the resistor and
the set operated normally
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
When the set shuts down. All Cathodes of the CRT are only
source was not running. I had the tech check R553 a .47 ohm
Sony KV27S25 Bright screen with retrace then unit
BRAND
Unit has the 200 vdc cathode source voltage measures 179
vdc but when measuring on the cathode directly the voltage
is very low 22 vdc. Disconnecting the socket causes the
voltage to rise back to 198 vdc. Unit has a defective CRT.
Disconnecting the CRT and measuring the RK, BK,& GK on
the CRT socket we found all of them running at 187 vdc. But
after connecting the socket again to the CRT they
immediately dropped to 33 volts. Unit will need a
Tech will need to replace the CRT. 8-733-741-05
Monitoring the "C" board Blue cathode terminal the tech
found the voltage was less than 70 volts when connected to
the CRT. Removing the module from the CRT the voltage
raises the voltage to 189 vdc at KB. CRT... Unit will need a
replacement CRT
KV32S26AA-2retrace
Sony
KV32S22AA-2retrace lines
Sony
KV32S22AA-2RETRACE LINES
Sony
KV32S22AA-2RETRACE LINES
Sony
Unit has bright screen with retrace lines. The
flyback was changed but did not correct the
symptom.
KV32S22 serial # Unit has bright screen with
retrace lines then it will shut down.
KV32S22 serial 8011789. Unit has intense blue
raster with retrace lines then shuts down. Tapping
on neck of tube aggravates the symptom
KV32S22 serial 8046606 Blue screen with retrace
lines then shuts down.
KV32S26AA-2RETRACE LINES
Sony
KV32S26AA-2retrace linesKV32S26. Unit has bright screen with retrace lines
Sony
KV32V25AA-2retrace lines
Sony
KV27S25AA-2retrace lines
Sony
KV32S26 Unit will go to as bright screen with
retrace lines then shut down.
KV32V25 serial 7019547. Unit has bright screen
with retrace lines then shuts down.
shuts down
66 volts. With the CRT disconnected from the module the
RK, BK,& GK will increase to 202 vdc. . Unit will need a
replacement CRT
Unit has the 200 vdc cathode source voltage measures 179
vdc but when measuring on the cathode directly the voltage
is very low 22 vdc. Disconnecting the socket causes the
voltage to rise back to 198 vdc. Unit has a defective CRT.
Measuring the 200 volt B+ at the CRT socket we found the
voltage to be under 126 vdc. This indicated the 200 volt
1/2 watt resistor and it was open. Replaced the resistor and
the set operated normally
I had tech measure the 200vdc supply line and it measured
only 78 volts. Unit had defective capacitor in the 200 vdc
source.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
Sony KV27V20 has retrace lines no video. Unit will
Symptom only shows up in the tuner mode. VCR in
remove the horizontal output transistor and try starting up the
BRAND
KV27V40AA-2retrace lines
Sony
KV32S40AA-2shading
Sony
KV32S25AA-2shut down
Sony
KV32S65AA-2shut down
Sony
shut down if left on after the filaments warm up.
KV32S40 Brightness shading in brighter on the
right side than it is on the left side of the screen.
video input mode is fine. Unit has CATV box
"Scientific Atlantic model 8580338".
KV32S25 Unit will not develop high voltage. When
the set is turned on no high voltage appears. The
set has sound and has a flashing light on the front
indicating the set is still in a stand by mode
waiting for IK pulse feed back acknowledgement
from the jungle IC
KV32S65 intermittently the set will turn off. This
process takes about 30 ~ 60 minutes. The set can
be turned back on again if the power button is
pressed twice. Sometimes the set comes on in the
Video 1 input mode when it was in the tuner mode
before it shut down.
Missing 200 volt source from flyback to CRT driver board.
Trace broken at CN1781
After checking out the box and moving the box it was
discovered the movement of the box effected the screen
brightness. The box was mounted directly beneath the
television. If the box was moved to the far left the symptom
disappeared. If centered below the TV the symptom was
evident. Solution was to move the CATV box away from the
television and remove any electromagnetic interference
caused by the television.
When monitoring the Horizontal output collector we found
the 140 dropped slightly at turn on. But the Horizontal driver
Q501(C) dropped to 85 and back up to 140. I had the tech to
set again. After power up measure the Q501(C) horizontal
driver transistor. It should be about 85 volts and stayed. This
told us we were looking at a shutdown symptom. Checking
all secondaries we found nothing shorted. Replaced flyback
which corrected trouble.
This could be caused by the CRT. Suggest the tech
disconnect the CRT socket an run the set with the tube
disconnected and see if the set shuts down with the CRT
disconnected. With the tube disconnected the chassis ran 3
days without shutting down. A CRT was substituted and the
problem never showed up on the other CRT. Replaced the
CRT and it corrected the symptom.
MODELChassisKEYWORDSYMPTOMCURE
TSS Logs for Sony Television Products
determine any chassis fault the problem must be due to CRT
volt source. It was suggested to replace D530. This corrected
back up sometimes the set will be in the "VIDEO 1"
BRAND
KV35V36AA-2Shut down
Sony
KV24FV10AA-2shutdown
Sony
KV32S22AA-2shutdown
Sony
KV32S40AA-2shutdown
Sony
KV32S65AA-2shutdown
Sony
KV35V35AA-2SHUTDOWN
Sony
KV32XBR48AA-2shuts down
Sony
KV35V36 serial 9024090 Unit has an intermittent
shut down that only occurs after two or three days.
When shut down occurs, the LED in front is
Blinking and raster disappears but sound is OK.
When flexing, heating, or freezing the main circuit
board the problem can never be recreated.
KV24FV10 Unit will shut down immediately after
turn on. But the unit will stay on if the service
mode is entered..
KV32S22 serial # 8055057. Unit will run fine for
15 ~ 30 minutes with sporadic arcing then it will
shut down with a bright green flash
KV32S40 Unit will turn on and immediately shut
down. It does get high voltage briefly. Appears to
be entering over current shutdown. Waveform at
the collector of the horizontal output appears
normal. Horizontal drive is normal if the horizontal
output transistor is removed.
KV32S65 Unit goes into shut down. Will allow HV
to com up but goes into immediate shut down
afterwards. At no time did we ever have Data on 9
& 10 of the Jungle IC
KV35V35 serial 9011978 Unit flashes bright green
with retrace lines then shuts down. When powered
mode.
KV32XBR48 Unit get a bright red screen then
looses horizontal sweep then shuts down. Unit can
be turned on again right away
Tech needs to order the CRT. Since we are not able to
confirm any trouble with chassis The CRT is nearly out of
Warranty. It is recommended that since we are unable to
arc over. Note after 4 weeks of normal operation the CRT
seems to have corrected the symptom.
When monitoring the VP at IC001(18) only 1 volt peak to
peak was measured. Floating IC001(18) allowed the voltage
to return to 5 volt PP. Replacing the IC001 corrected the
Unit needs replacement CRT 8-733-741-05.
Severing the 135 B+ line and placing a 40 watt bulb in series
with the supply were are still getting the same symptom but
the Light illuminates brightly. We began to disconnect the
flyback loads D530, D531. After disconnecting these we
found the set will run with D530 disconnected . Checking this
device it passes the static check. This component is the -15
Open coil that supplied the B+ to the audio controller and
buffer chips. This loss in voltage caused the audio processor
chip to load down the Data and Clock lines and cause this
symptom.
?Unit has a defective CRT. A89LJT80X
Tech needs to tap on neck of CRT and see if the symptom is
aggravated by this action. After tech got to the house an
tapped on CRT it was founf that the Tube was causing the