STR-DA3000ES
SERVICE MANUAL
Ver 1.1 2004.09
SUPPLEMENT-1
Subject: Addition of “SPECIAL MENU MODE”
US Model
Canadian Model
AEP Model
E Model
9-961-109-81

STR-DA3000ES
SPECIAL MENU MODE
Procedure:
1. Press the I/1 button to turn on the main po wer, then while pressing the [MEMORY/ENTER] button, press the [MOVIE] button in order.
2. The message “MENU EXPANDED !” appears.
3. Each time the [MENU] dial is turned clockwise, the item is switched in order as follows.
4. To release from this mode, while pressing the [MEMORY/ENTER] button, press the [MOVIE] button in order again.
5. The message “MENU EXPAND OFF” appears.
Items Display Remark
Protector on/off SPECIAL XXX: ON or OFF (switching with
PROTECTOR ON/OFF [XXX
Model version display SPECIAL ####: model
####
Model/distination change SPECIAL ####: model,
MODEL [
FL display fonts test SPECIAL
FL FONT 0x** = [X
FL display test ALL ON Each time
Audio swap SPECIAL Switching with
SWAP [XXXXXXXXXXX
DSP reset SPECIAL XXX: ON or OFF (switching with
DSP RESET [XXX
DSP 1 IRAM DSP 1 IRAM The umbers which can be changed will blinks
[
I
*****
DSP 1 ARAM DSP 1 ARAM The umbers which can be changed will blinks
[
D
*****
DSP 2 IRAM DSP 2 IRAM The umbers which can be changed will blinks
[
I
*****
vX.XX @@@@
****
####
]=
]=
]=
****
]
] Note: Since it continues being reset when “DSP RESET [ON]”
XXXX To select the digit: Press the [TUNING +] or [TUNING --] button
XXXXXXXX To select the digit: Press the [TUNING +] or [TUNING --] button
XXXX To select the digit: Press the [TUNING +] or [TUNING --] button
]
: destination
****
X.XX: main microprocessor software version
@@@@: Sum value of flash memory in the main microprocessor
: destination, XX: at or fx
]
XX (switching with [--/+] dial)
: 20 to 1F, X: character (switching with [--/+] dial)
**
****
[DISPLAY] button to change as follows.
all on t test pattern 1 t test pattern 2 t all off t all on
[--/+] dial
]
is chosen, be sure to return to “DSP RESET [OFF]”
T o select the number when the umbers (
Rotate the [--/+] dial
To perform the write when the umbers (XXXX) blinks:
Press the
*****
XXXX: instruction RAM address data
Note: When parenthesis is the position of instruction RAM
T o select the number when the umbers (
blinks: Rotate the [--/+] dial
To perform the write when the umbers (XXXXXXXX) blinks:
Press the [MEMORY/ENTER] button
*****
XXXXXXXX: coefficient RAM address data
Note: When parenthesis is the position of
T o select the number when the umbers (
Rotate the [--/+] dial
To perform the write when the umbers (XXXX) blinks:
Press the [MEMORY/ENTER] button
*****
XXXX: instruction RAM address data
Note: When parenthesis is the position of instruction RAM
[MEMORY/ENTER] button
: instruction RAM address
address data, up/down of the menu item by
are invalid
: coefficient RAM address
address data, up/down of the menu item by
are invalid
: instruction RAM address
address data, up/down of the menu item by
are invalid
[--/+] dial)
[--/+] dial)
*****
*****
coefficient
*****
or XXXX) blinks:
the [MENU] dial
or XXXXXXXX)
RAM
the [MENU] dial
or XXXX) blinks:
the [MENU] dial
2

STR-DA3000ES
Items Display Remark
DSP 2 ARAM DSP 2 ARAM The umbers which can be changed will blinks
[
D
*****
Bass management SPECIAL
BASSMAN. [
DSP boot error SPECIAL Not used for the servicing
DSP write 1 error SPECIAL Not used for the servicing
DSP write 2 error SPECIAL Not used for the servicing
DSP write 3 error SPECIAL Not used for the servicing
DSP read 1 error SPECIAL Not used for the servicing
DSP read 2 error SPECIAL Not used for the servicing
DSP read 3 error SPECIAL Not used for the servicing
DSP HALT SPECIAL XXX: ON or OFF (switching with
DSP HALT [XXX
DSP Version display SPECIAL Not used for the servicing
SurV *:vXXX
Volume value display SPECIAL Not used for the servicing
(FL/FR) FL
Volume value display SPECIAL Not used for the servicing
(SL/SR) SL
Volume value display SPECIAL Not used for the servicing
(CT/SW) CT
Volume value display SPECIAL Not used for the servicing
(SBL/SBR) SBL
EEPROM debug SPECIAL
EEPROM
Super reset SPECIAL Not used for the servicing
SUPER RESET [XXX
2nd volume value display SPECIAL XX: 2nd zone volume value (00 to
2nd VOLUME –XX (switching with [--/+] dial)
3rd volume value display SPECIAL XX: 3rd zone volume value (00 to
3rd VOLUME –XX (switching with [--/+] dial)
FL display duty change SPECIAL XXX: Duty value of FL display (0% to 100%)
DARK OUT DUTY [XXX%
SDRAM check SPECIAL Check the operation of LIP SYNC
SDRAM CHECK [XXXXX
Error count display SPECIAL Not used for the servicing
SCOM ERROR COUNT XXX
Version display SPECIAL Not used for the servicing
Sub Micom Ver. X.XX
]=
XXXXXXXX To select the digit: Press the [TUNING +] or [TUNING --] button
To select the number when the umbers (
blinks: Rotate the [--/+] dial
To perform the write when the umbers (XXXXXXXX) blinks:
Press the
*****
XXXXXXXX: coefficient RAM address data
Note: When parenthesis is the position of
address data, up/down of the menu item by
are invalid
: AUTO or OFF, XX: 02 to 30
] XX (switching with [--/+] dial)
****
****
DSP BOOT ERROR:XXX
DSP WRT1 ERROR:XXX
DSP WRT2 ERROR:XXX
DSP WRT3 ERROR:XXX
DSP RAD1 ERROR:XXX
DSP RAD2 ERROR:XXX
DSP RAD3 ERROR:XXX
[MEMORY/ENTER] button
: coefficient RAM address
*****
coefficient
[--/+] dial)
]
FR XXXX
****
SR XXXX
****
SW XXXX
****
SBR XXXX
****
: EEPROM address
[
****
]
XX XX: EEPROM data (switching with [--/+] dial)
]
****
If super reset is performed, “up convert signal level adjustment”
will also be initialized
When EEPROM initialization is required, perform the “all clear
mode” (see page 14 of original service manual)
)
∞
)
∞
]
(switching with [--/+] dial)
]
XXXXX: PASS (OK) or ERROR (NG)
or XXXXXXXX)
RAM
the [MENU] dial
3