This document explains typical Procedures and Tips for the NDI®|HX connectivity when using
Sony’s Color Video Camera SRG-XP1/SRG-XB25.
Services and software provided by other companies
・Separate terms and conditions of use may be applied.
・Provision of services and software updates may be interrupted or terminated without notice.
・Services and software content are subject to change without notice.
・Separate registration and/or payment may be required.
Please note that Sony Corporation is not responsible for any claim, from customers or third
parties, arising from any use of services and software provided by other companies.
Please setup NDI®|HX network connection under following disturbance condition.
Packet Loss : < 1%
Latency : < 100ms
Sony Version 1.1
2
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
2.
Flowchart
The flowchart shows outline of the procedure for enabling the NDI®|HX connectivity function of
the camera described in the following chapter.
Sony Version 1.1
3
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
3.
Pre-configuration Settings
This section describes some pre-configuration settings you will need before activating the NDI®|HX
function for the SRG-XP1/XB25.
3.1. Set IP address by using the RM-IP Setup Tool
For IP communication, the IP address needs to be set. You can use RM-IP Setup Tool to assign IP
address to the camera. Please refer to the RM-IP Setup Tool Guide for more details.
The NDI® Tools (provided by NewTek on the NewTek web site) will detect a Camera by using
“Name” filed data displayed on the RM-IP Setup Tool. When you use the NDI®|HX function for
multiple cameras, it is recommended to change the “Name” in advance. The default camera Name
is “CAM1”.
[Note]
The DHCP setting cannot be enabled from the RM-IP Setup Tool.
3.2. Change the default password
When the procedure of 3.1 and 3.2 are performed, HTTP access to the camera is available. Please
change the default password (initial password) according to the Operation Manual of the Camera.
Ref). The section of [Accessing the Camera from a Web Browser]-[Changing the Initial Password]
of the Camera’s Operation Manual.
3.3. Camera’s Codec Setting
The NewTek NDI® System acquires a video stream with an appropriate resolution as needed.
In the case of Sony SRG-XP1/XB25, Image 1~3 channels are used. Codec configurations such as
respective channels' image size and frame rate etc. are automatically determined depending on
"Ouput type" setting when NDI functionality is enabled as follows.
The NDI® system utilizes audio stream also when the camera’s audio output setting is enabled.
Enable/disable the audio transmission function regarding the use case.
The related settings are in the [Audio] tab on the [Audio] page of the administrator menu.
3.4. UPnP Setting
Disable UPnP function from the UPnP setting page of the camera webpage before registration the
NDI®|HX as below figure:
Sony Version 1.1
5
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
Sony Version 1.1
6
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
3.5. NDI® Tools download/installation
To activate NDI®|HX function of the camera and connect to NDI® products via NDI®|HX function,
the NDI® Tools provided by NewTek needs to be installed on a PC.
NDI® Tools is available from the following site.
https://ndi.tv/tools/
Once NDI® Tools is installed, the software below will be available for the Windows OS.
Access Manager
Scan Converter
Studio Monitor
Test Patterns
Virtual Input
3.6. Remote Source settings via Access Manager
The Access Manager tool allows you to configure the connection settings for remote sources (NDI®
media sources connected to the network) in the NDI® system.
Stop Studio Monitor
When NDI® Studio Monitor is launched before starting the Access Manager, stop and close all
the NDI
Launch Access Manager
®
Studio Monitor windows.
Launch Access Manager. Go to the [Remote Sources] tab.
Sony Version 1.1
7
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
Click the [New] button to register the camera access settings. Use the following settings in the
new dialog box.
Type: Select NDI from the menu option.
Device IP Address: Input camera’s IP address
Local Device Name: Specify the list name displayed when selecting the source of the
NDI® system. (The default name is NDI Source).
Local Device Channel: Specify the name to be displayed in the above Local Device Name
list.
Sony Version 1.1
8
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
When the entry set in the list on the Remote Source tab h as been cre ated, p ress [OK] to exit the
Access Manager.
Launch Studio Monitor to confirm
Launch NDI® Studio Monitor. When opening the Studio Monitor, move the cursor into the
Studio Monitor window and right-click. Make sure that the entry is visible in the NDI source
list as [Local Device Name] -> [Local Device Channel].
If it is not confirmed, stop all the NDI® Tools, launch the Access Manager again and check the
settings.
Sony Version 1.1
9
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
Sony Version 1.1
10
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
4.
NDI®|HX License Key Registration
The NDI®|HX License Key registration is required for the camera to be workable with its NDI®|HX
function.
You can purchase the NDI®|HX License Key from the following NewTek URL.
http://new.tk/ndi_sony
The following describes the registration procedure after successfully purchasing the License Key.
Note:
After NDI®|HX License Key is registered to camera, we can use only NDI streaming. We will
not be able to use other streaming method which can be used before. (RTSP[Unicast, Multicast],
RTMP, MPEG-TS and SRT)
Lisence key can’t be deleted by “factory default”. So, once we regisered it, we can’t remove.
4.1. Connect to the Internet
Connecting to the Internet is required when you register a license key.
4.2. Launch NDI® Studio Monitor and select a camera
Launch the NDI® Studio Monitor, and move the mouse cursor in the window and right click. The
cameras that can be connected via NDI® on the network are displayed in the list.
Sony Version 1.1
11
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
When the remote source setting by the Access Manager shown in the Section 3.6 is performed, the
corresponding camera is displayed as [Local Device Name] -> [Local Device Channel].
If the remote source is not set by the Access Manager , the Camera name set in the Section 3.1 (default
value is “CAM1”)-> Channel 1, <IP address> will be displayed.
Select (left-click) the camera. A screen window that asks you to register the NDI®|HX License Key
is displayed as shown below.
4.3. Register the NDI®|HX License Key
Click the [REGISTER] button at the bottom right of the screen window displayed as above, and
register the License Key.
Click the button to register the License Key. When the button is pressed, the following dialog box
will appear.
Sony Version 1.1
12
Technical Guide | SRG-XP1/XB25
NDI®|HX introduction
You can purchase a license via the above link of [1. The Purchase NDI®|HX License].
(http://new.tk/ndi_sony).
Enter the key string obtained by purchasing a license into [2. Enter NDI | HX License Key]. (Sample
capture shows XXXX…).
Enter Camera’s user name and password in the field of User Name and Password in [3. Enable
NDI®|HX on this camera] and click the [Enable NDI®|HX] button.
When the registration succeeds, the following dialog will pop up.
When you click the [OK] button, NDI® Studio Monitor shows the video of the corresponding camera.
You can see that the NDI®|HX function has been activated.
When starting NDI ® Studio Monitor, yet no cameras are detected and therefore there is no
camera listed in the camera list on the NDI® Studio Monitor.
[Case-1] Depending on your computer environment (Windows PC), the device detection
mechanism may be filtered due to personal firewall settings or anti-virus settings, and the
camera may not be detected. In such a case, please review the security settings of your computer
or perform remote source setting by using Access Manager as described in the Section 3.6.
[Case-2]
There is a report that device detection does not work properly if a network adapter called
“Loopback Adapter” is configured on your computer (Windows PC). Installing the software
called “Wireshark” may configure a network adapter called “Npcap Loopback Adapter”. If you
want the device detection mechanism of NDI® Studio Monitor to work, disabling this network
adapter may solve the problem.
The NDI®|HX License Key registration failed even when the [Enable NDI®|HX] button was
pressed.
[Case-1]
When registering an NDI®|HX License Key, your computer (the computer on which NDI®
Studio Monitor is installed) needs to be connected to the Internet. If the camera and the computer
are installed in a corporate network, make sure that the proxy server settings on the computer
are properly set.
[Case-2]
Once a License Key has been registered to a camera, it cannot be registered to another camera.
Please purchase a separate license for each NDI®|HX camera.
The NDI®|HX License Key registration was successful, but the camera image after registration
is not displayed, and the monitor window is black.
[Case-1]
This issue will occur when the remote source setting by Access Manager described in Section
Sony Version 1.1
15
Technical Guide | SRG-XP1/XB25
3.6 is not performed with the RTSP authentication setting on the camera “On”.
Here is some background information on what is occurring. NDI® Studio Monitor tries to make
an R TSP connection to th e camera and the camera requests authentication information, but NDI®
Studio Monitor does not know the necessary authentication information, then it will repeat
connection failures.
Once this issue occurs, the “brute force attack protection” function of the camera may be
activated in some cases. If there is continuous accessing that causes an authentication error, the
computer will be recognized as an “illegal client” and the accessing from that computer will not
be allowed for a certain period of time.
If this symptom occurs, please stop NDI® Studio Monitor immediately and wait for about a
minute (in the case of the camera default setting). After that, please input the information for
the camera as described in Section 3.6. Finally, quit Access Manager and restart NDI® Studio
Monitor to access the camera.
NDI®|HX introduction
The video playback on the NDI® Studio Monitor is not smooth or sometimes freezes.
This issue may be due to the performance of your computer or the network environment.
[Case-1]
This issue may be improved by using the hardware acceleration function of your computer
(Windows). Open NDI® Studio Monitor, and choose the context menu, then check Allow H/W
Acceleration under [Settings] -> [Video].
[Case-2]
Ensure you have a Gigabit Ethernet connection as insufficient bandwidth may be an issue.
Please make sure that the network connection is good to at least meet the following conditions.
Packet Loss : < 1%
Latency : < 100ms
Sony Version 1.1
16
Disclaimer
This document, in whole or in part, may not be reproduced or transferred for any purpose without
prior written approval from Sony Corporation.
Sony Corporation reserves the right to make any modification to this document or the information
contained herein at any time without notice.
Sony Corporation shall not bear any responsibility or liability for any damage, lost earning, and
third-party claim, resulting from the products and related documents.
NDI® is a registered trademark of NewTek, Inc.
Network services, content, and the [operating system and] software of this Product may
be subject to individual terms and conditions and changed, interrupted or discontinued
at any time and may require fees, registration and credit card information.
Copyright
This document contains registered trademarks and trademarks that are owned by their respective
companies.
Sony Version 1.1