Sony SLV-E920EG Service Manual

SERVICE MANUAL
RMT-V195
SLV-E920EG
SUPPLEMENT-1
File this supplement with the service manual.
Subject: EEP ROM INITIAL DATA INPUT
(99-011)
1. EEP ROM INITIAL DATA INPUT
sure to input the data shown below and to perform both “2-3-1. RF
Switching Position Adjustment” and “2-5-1. 1. AF Switching Po-
sition Adjustment ”.
Input Method:
1) Connect the LANC jig (J-6090-051-A) to CN164 on MA-287
board.
2) Turn on the power.
3) Input Data: 80 in Address: 00 on Page: 1.
4) Input data on Page F as following table.
5) Turn off the power
6) Disconnect the adjusting remote commander and LANC jig
from the connector (CN164).
MA-287 board, first connect the adjusting remote com-
mander (J-6082-053-B) to the jack on LANC jig before
connecting LANC jig to CN164. Connection or disconnec-
tion of the adjusting remote commander in the condition
LANC jig is connected to CN164 causes IC LINK (PS001)
to damage itself.
Sony Corporation
Home Video Company
9-921-660-81
99I05050-1D
Printed in Japan © 1999. 9
Published by Quality Assurance Dept.
Greek Model
Page
Address
BA
B9B6B594930201
Note
F
Data
*Note for Extension
FF
01
13
61
01
20
02
13 053
Loading...