SERVICE MANUAL
SUPPLEMENT-1
SLV-E870EN
RMT-V196
North European Model
File this supplement with the service manual.
Subject: EEP ROM INITIAL DATA INPUT
1. EEP ROM INITIAL DATA INPUT
When EEP ROM (IC472 on FR-119 board) was changed, make it
sure to input the data shown below and to perform both “2-3-1. RF
Switching Position Adjustment” and “2-5-1. 1. AF Switching Position Adjustment ”.
Input Method:
1) Connect the LANC jig (J-6090-051-A) to CN164 on MA-287
board.
2) Turn on the power.
3) Input Data: 80 in Address: 00 on Page: 1.
4) Input data on Page F as following table.
F
B9B6B594930201
01
1071012001
01200113SLV-E870EN
10
71
01
*Note for Extension
BA
FF
FF
Note
021
053
Data
Page
Address
SLV-E870EN
08
(99-013)
5) Turn off the power
6) Disconnect the adjusting remote commander and LANC jig
from the connector (CN164).
Note: When connecting or disconnecting LANC jig to CN164 on
MA-287 board, first connect the adjusting remote commander (J-6082-053-B) to the jack on LANC jig before
connecting LANC jig to CN164. Connection or disconnection of the adjusting remote commander in the condition
LANC jig is connected to CN164 causes IC LINK (PS001)
to damage itself.