Sony SDX-D1100V annexe

2-176-211-16(1)
SDX-D1100V/D900V/D800V/D700V/D500V/D400V
AIT Drive Unit
Operator’s Guide
Safety Regulations
Owner’s Record
The model and serial numbers are located on the bottom. Record the serial number in the space provided below. Refer to them whenever you call upon your dealer regarding this product.
Model No. Serial No. ________________________ __________________________________
Information
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
Model No. for Regulatory Compliance
Your SDX-D1100V is assigned a Model No.: SDX-D1100 for regulatory compliance certifications.Your SDX-D900V and SDX-D800V are assigned a Model No.:ATDEA4 for regulatory compliance certifications. Your SDX-D700V is assigned a Model No.: ATDEA3 for regulatory compliance certifications. Your SDX-D500V and SDX-D400V are assigned a Model No.: ATDEA2 for regulatory compliance certifications. The number is indicated on the model number label on your drive along with the rated voltage and current.
2 Safety Regulations
For the customers in the USA
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
DECLARATION OF CONFORMITY
Trade Name: SONY Model: SDX-D1100, ATDEA4, ATDEA3, ATDEA2 Responsible Party: Sony Electronics Inc. Address: 16530 Via Esprillo San Diego, CA.
92127 U.S.A. Telephone number: 858-942-2230 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including
interference that may cause undesired operation.
WARNING Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
CAUTION
The mains plug on this equipment must be used to disconnect mains power. Please ensure that the socket outlet is installed near the equipment and shall be easily accessible.
ACHTUNG
Zur Trennung vom Netz ist der Netzstecker aus der Steckdose zu ziehen, welche sich in der Nähe des Gerätes befinden muß und leicht zugänglich sein soll.
Hinweis
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäss EN ISO 7779.
NOTICE
Use the power cord set approved by the appropriate testing organization for the specific countries where this unit is to be used.
HINWEIS
Die 3-adrige Geräteanschlußleitung muß Typ H05VV-F oder H05VVH2-F sein und nach DIN VDE 0625 geprüft sein. Der Stecker und die Gerätesteckdose müssen nach DIN VDE 0620 bzw DIN VDE 0625 geprüft sein. Der Leitungsquerschnitt kann 0,5 mm2 betragen wenn die Anschlußleitung eine Länge von 2 m nicht überschreitet. Anderenfalls muß der Leitungsquerschnitt mindestens 0,75 mm2 betragen.
If you have any questions about this product, please refer to Sony contact in the instruction manual.
Safety Regulations 3
ATTENTION
According to the EU Directives related to product safety, EMC and R&TTE the manufacturer of this product is Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan. The Authorised Representative is Sony Deutschland GmbH, Hedelfinger Strasse 61,70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents.
AUFMERKSAMKEIT
Im Sinne der EU Richtlinien bezüglich Produktsicherheit, EMV und R&TTE ist Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan der Hersteller dieses Produktes. Bevollmächtigter ist Sony Deutschland GmbH, Hedelfinger Strasse 61, D-70327 Stuttgart. Für Service oder Garantieangelegenheiten wenden Sie sich bitte an die in separaten Service oder Garantiedokumenten angegebenen Adressen.
European Union Restriction of Hazardous Substances Directive compliant.
Entspricht der Richtlinie der Europäischen Union zur Beschränkung der Verwendung gefährlicher Stoffe.
Für Kunden in Deutschland
Diese Ausrüstung erfüllt die Europäischen EMC-Bestimmungen für die Verwendung in folgender/folgenden Umgebung(en):
– Wohngegenden – Gewerbegebiete
– Leichtindustriegebiete (Diese Ausrüstung erfüllt die Bestimmungen der Norm EN 55022, Klasse B.)
4 Safety Regulations
IMPORTANT SAFEGUARDS
For your protection, please read these safety instructions completely before operating the appliance, and keep this manual for future reference.
Carefully observe all warnings, precautions and instructions on the appliance, or described in the operating instructions and adhere to them.
USE
Power Sources – This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of electrical power, consult your dealer or local power company.
For the unit with a three-wire grounding type ac plug:
If you are unable to insert the plug into the outlet, contact your electrician to have a suitable plug installed. Do not defeat the safety purpose of the grounding plug.
AC Power cord:
The AC power cord should have appropriate safety approvals or marking for the country in which the equipment will be used. Consult your dealer or local power company.
Cleaning – Unplug the unit from the wall outlet before cleaning or polishing it. Do not use liquid cleaners or aerosol cleaners. Use a cloth lightly dampened with water for cleaning the exterior of the unit.
Object and Liquid Entry – Never push objects of any kind into the unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.
Safety Regulations 5
INSTALLATION
Water and Moisture – Do not use power-line operated units near water - for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, etc.
Power-Cord Protection – Route the power cord so that it is not likely to be walked on or pinched by items placed upon or against it, paying particular attention to the plugs, receptacles, and the point where the cord exits from the appliance.
Accessories – Do not place the unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall, causing serious injury to a child or an adult, and serious damage to the unit. Use only a cart, stand, tripod, bracket, or table recommended by the manufacturer.
Ventilation – The slots and openings in the cabinet are provided for necessary ventilation. To ensure reliable operation of the unit, and to protect it from overheating, these slots and openings must never be blocked or covered.
• Never cover the slots and openings with a cloth or other materials.
• Never block the slots and openings by placing the unit on a bed, sofa, rug, or other similar surface.
• Never place the unit in a confined space, such as a bookcase, or built-in cabinet, unless proper ventilation is provided.
SERVICE
Damage Requiring Service – Unplug the unit from the wall outlet and refer servicing to qualified service personnel under the following conditions:
• When the power cord or plug is damaged or frayed.
• If liquid has been spilled or objects have fallen into the unit.
• If the unit has been exposed to rain or water.
• If the unit has been subject to excessive shock by being dropped, or the cabinet has been damaged.
• If the unit does not operate normally when following the operating instructions. Adjust only those controls that are specified in the operating instructions. Improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to normal operation.
• When the unit exhibits a distinct change in performance - this indicates a need for service.
Servicing – Do not attempt to service the unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer to all servicing to qualified service personnel.
6 Safety Regulations
Table of Contents
How To Use This Guide ..................................................................... 8
Part 1. Introduction
Part 2. Preparation
Part 3. Operation
Part 4. Care and Maintenance
About AIT Drives ............................................................................... 9
Features .................................................................................................... 9
Compatible Data Cartridges .................................................................. 12
System Components .............................................................................. 13
Part Names and Functions ............................................................. 14
Front Panel ............................................................................................. 14
Rear Panel .............................................................................................. 15
Supplied Items................................................................................. 16
Interconnections ............................................................................. 16
SCSI ID Setting ................................................................................ 17
Option Switches (DIP Switch) ........................................................ 17
How To Use the AIT Drive ............................................................... 22
Cartridge Removal ................................................................................. 23
Attaching the Dust Cover ............................................................... 24
WORM Function .............................................................................. 26
Taking Care of the Drive ................................................................. 28
Safety Considerations ............................................................................ 28
Avoiding Damage .................................................................................. 28
Taking Care of Cartridges .............................................................. 30
Use Precautions ..................................................................................... 30
Storage Precautions ............................................................................... 30
Cleaning ........................................................................................... 31
How To Clean ........................................................................................ 31
Appendix
Specifications (SDX-D1100V) ......................................................... 32
Specifications (SDX-D900V) ........................................................... 33
Specifications (SDX-D800V) ........................................................... 34
Specifications (SDX-D700V) ........................................................... 35
Specifications (SDX-D500V) ........................................................... 36
Specifications (SDX-D400V) ........................................................... 37
Table of Contents 7

How To Use This Guide

This Guide describes the SDX-D1100V/SDX-D900V/SDX-D800V/ SDX-D700V/SDX-D500V/SDX-D400V drive, and how to take care of it. Please read it carefully before using the unit, and keep it handy for future reference. The Guide consists of four parts, plus the specifications. Refer to the parts that relate to your use of the drive.
Part 1 describes the features of the drive, its system components, and the name and function of each part.
Part 2 describes the necessary connections between the drive and the host computer. If other SCSI devices are being used, you may need to change the SCSI ID setting. Read this part if you are installing the drive.
Part 3 describes how to use the drive, including how to turn it on, and how to insert and remove cartridges. Read this part if you are going to operate the drive.
Part 4 describes how to take care of the drive and cartridges, and how to clean the drive. Read this part before using the drive.
Appendix provides the major specifications of the SDX-D1100V/ SDX-D900V/SDX-D800V/SDX-D700V/SDX-D500V/SDX-D400V drive.
8 How to Use this Guide

Part 1. Introduction

About AIT Drives

The SDX-D1100V AIT-5 Tape Drives is an external AIT drive unit that uses data cartridges conforming to the AIT-5 format. The SDX-D900V AIT-4 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-4 format. The SDX-D800V AIT-3 Ex Tape Drives is an external AIT drive unit that uses data cartridges conforming to the AIT-3 Ex format. The SDX-D700V AIT-3 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-3 format. The SDX-D500V AIT-2 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-2 format. The SDX-D400V AIT-1 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-1 format.
The SDX-D1100V drive supports the AIT-5, AIT-4, AIT-3 Ex, and AIT-3 formats. The SDX-D900V drive supports the AIT-4 and AIT-3 Ex format. The SDX-D800V drive supports the AIT-3 Ex, AIT-3, AIT-2 Turbo, AIT-2 (Read only), AIT-1 Turbo (Read only), AIT-1 (Read only), and AIT-E Turbo (Read only) formats. The SDX-D700V drive supports the AIT-3, AIT-2, and AIT-1 formats. The SDX-D500V drive supports the AIT-2 and AIT-1 formats. The SDX-D400V drive supports only the AIT-1 format.

Features

The SDX-D1100V drive has the following features:
• Supports reading and writing to data cartridges conforming to the AIT-5,
AIT-4, AIT-3 Ex, and AIT-3 formats.
• The second-level error correction code guarantees high data reliability
writing to data cartridges conforming to the AIT-5, AIT-4, and AIT-3 Ex formats.
• The third-level error correction code guarantees high data reliability writing
to data cartridges conforming to the AIT-3 format.
• Data compression provides 1,040 gigabytes of storage on SDX5-400C data
cartridges.* The native capacity is 400 gigabytes of storage on SDX5-400C data cartridges.
• Stored data are automatically checked for compression.
• Ultra 160 SCSI interface is fully supported for host computer access.
• Fragment rewrite function (AIT-5, AIT-4, AIT-3 Ex)
• Frame rewrite function (AIT-3)
*
This is assuming 2.6:1 compression ratio. The degree of data compression attained while recording data varies according to system environment and data type.
Part 1. Introduction 9
The SDX-D900V drive has the following features:
• Supports reading and writing to data cartridges conforming to the AIT-4
and AIT-3 Ex formats.
• The second-level error correction code guarantees high data reliability
writing to data cartridges conforming to the AIT-4 and AIT-3 Ex formats.
• Data compression provides 520 gigabytes of storage on SDX4-200C data
cartridges.* The native capacity is 200 gigabytes of storage on SDX4-200C data cartridges.
• Stored data are automatically checked for compression.
• Ultra 160 SCSI interface is fully supported for host computer access.
• Fragment rewrite function
The SDX-D800V drive has the following features:
• Supports reading and writing to data cartridges conforming to the AIT-3 Ex,
AIT-3, and AIT-2 Turbo formats.
• Supports reading from data cartridges conforming to the AIT-2, AIT-1 Turbo,
AIT-1, and AIT-E Turbo formats.
• The second-level error correction code guarantees high data reliability
writing to data cartridges conforming to the AIT-3 Ex format.
• The third-level error correction code guarantees high data reliability writing
to data cartridges conforming to the AIT-3 format.
• Data compression provides 390 gigabytes of storage on SDX3X-150C data
cartridges.* The native capacity is 150 gigabytes of storage on SDX3X-150C data cartridges.
• Stored data are automatically checked for compression.
• Ultra 160 SCSI interface is fully supported for host computer access.
• Fragment rewrite function (AIT-3 Ex)
• Frame rewrite function (AIT-3)
10 Part 1. Introduction
The SDX-D700V drive has the following features:
• Supports reading and writing to data cartridges conforming to the AIT-3,
AIT-2, and AIT-1 formats.
• The third-level error correction code guarantees high data reliability.
• Data compression provides 260 gigabytes of storage on SDX3-100C data
cartridges.* The native capacity is 100 gigabytes of storage on SDX3-100C data cartridges.
• Stored data are automatically checked for compression.
• Ultra 160 SCSI interface is fully supported for host computer access.
• Frame rewrite function
*
This is assuming 2.6:1 compression ratio. The degree of data compression attained while recording data varies according to system environment and data type.
The SDX-D500V drive has the following features:
• Supports reading and writing to data cartridges conforming to the AIT-2
and AIT-1 formats.
• The third-level error correction code guarantees high data reliability.
• Data compression provides 130 gigabytes of storage on SDX2-50C data
cartridges.* The native capacity is 50 gigabytes of storage on SDX2-50C data cartridges.
• Stored data are automatically checked for compression.
• Wide Ultra SCSI (LVD/SE) interface is fully supported for host computer
access.
• Frame rewrite function
The SDX-D400V drive has the following features:
• Supports reading and writing to data cartridges conforming to the AIT-1
format.
• The third-level error correction code guarantees high data reliability.
• Data compression provides 91 gigabytes of storage on SDX1-35C data
cartridges.* The native capacity is 35 gigabytes of storage on SDX1-35C data cartridges.
• Stored data are automatically checked for compression.
• Wide Ultra SCSI (LVD/SE) interface is fully supported for host computer
access.
• Frame rewrite function
*
This is assuming 2.6:1 compression ratio. The degree of data compression attained while recording data varies according to system environment and data type.
Part 1. Introduction 11

Compatible Data Cartridges

The SDX-D1100V drive can be used with data cartridges marked with the AIT-5, AIT-4, AIT-3 Ex, or AIT-3 logo. The SDX-D900V drive can be used with data cartridges marked with the AIT-4 or AIT-3 Ex logo. The SDX-D800V drives can be used with data cartridges marked with the AIT-3 Ex, AIT-3, AIT-2 Turbo, AIT-2 (read only), AIT-1 Turbo (read only), AIT-1 (read only), or AIT-E Turbo (read only) logo. The SDX-D700V drive can be used with data cartridges marked with the AIT-3, AIT-2, or AIT-1 logo. The SDX-D500V drive can be used with data cartridges marked with the AIT-2 or AIT-1 logo. The SDX-D400V drive can be used with data cartridges marked with the AIT-1 logo.
AIT-E Turbo LOGO
AIT-1 LOGO
AIT-1 Turbo LOGO
AIT-2 LOGO
AIT-2 Turbo LOGO
AIT-3 LOGO
AIT-3 Ex LOGO
AIT-4 LOGO AIT-5 LOGO
Caution
• Do not use cartridges other than the ones described above with this drive.
Be sure to use only the cartridges designed specifically for AIT.
• Do not use anything but AIT cartridges with this drive, as doing so can
damage the drive. Although commercially available 8 mm videotapes resemble AIT cartridges in appearance, they have entirely different specifications and cannot be used.
12 Part 1. Introduction
Loading...