US and foreign patents licensed from Dolby
Laboratories.
• SonicStage, MD Simple Burner, OpenMG, “Magic Gate”, “MagicGate Memory Stick”,
“Memory Stick”, Hi-MD, Net MD, ATRAC, ATRAC3, ATRAC3plus and their logos are
trademarks of Sony Corporation.
• Microsoft, Windows, Windows NT and Windows Media are trademarks or registered
trademarks of Microsoft Corporation in the United States and /or other countries.
• IBM and PC/AT are registered trademarks of International Business Machines Corporation.
• Macintosh is a trademark of Apple Computer, Inc. in the United States and/or other countries.
• MMX and Pentium are trademarks or registered trademarks of Intel Corporation.
• All other trademarks and registered trademarks are trademarks or registered trademarks
of their respective holders.
US Model
Canadian Model
Model Name Using Similar MechanismNEW
MD Mechanism TypeMT-MZNH900-181
Optical Pick-up Mechanism TypeABX-U
Audio playing system
MiniDisc digital audio system
Laser diode properties
Material: GaAlAs
Wavelength: λ = 790 nm
Emission duration: continuous
Laser output: less than 44.6 µW
(This output is the value measured at a distance
of 200 mm from the lens surface on the optical
pick-up block with 7 mm aperture.)
Recording and playback time
When using HMD1G (1GB disc):
Maximum 34 hours in Hi-LP stereo
When using MDW-80 in Hi-MD mode:
Maximum 10 hours and 10 min. in Hi-LP
stereo
When using MDW-80 in MD mode:
Maximum 160 min. in monaural
Maximum 320 min. in LP4 stereo
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation
exposure.
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
Flexible Circuit Board Repairing
• Keep the temperature of the soldering iron around 270 ˚C
during repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
UNLEADED SOLDER
Boards requiring use of unleaded solder are printed with the leadfree mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40 °C higher
than ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350 °C.
Caution: The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful!
• Strong viscosity
Unleaded solder is more viscou-s (sticky, less prone to flow)
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
8.ELECTRICAL PARTS LIST................................ 46
2
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE
WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS P AR UNE MARQ UE 0 SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU D ANS LES SUPPLÉMENTS
PUBLIÉS PAR SONY.
SECTION 1
SERVICING NOTES
MZ-NH600D
Ver. 1.2
NOTES ON HANDLING THE OPTICAL PICK-UP
BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pickup block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
OPERATION CHECK WHEN THE LID IS OPEN
In making an operation check with the MAIN Board removed from
the set, short the SL894 (OPEN/CLOSE) of the MAIN Board with
the solder before starting the operation check.
Note: Be sure to remove the solder used for shortcircuit after the repaire
completed.
– MAIN Board (Conductor Side) –
Providing the required system environment
System requirements
The following system environment is required in order to use the SonicStage Ver. 2.0/MD
Simple Burner Ver. 2.0 software for the MD Walkman.
ComputerIBM PC/AT or Compatible
Operating
System
DisplayHigh Color (16bit) or higher, 800 × 600 dots or better (1024 × 768 dots
Others•Internet access: for Web registration, EMD services and CDDB
This software is not supported by the following environments:
• OSs other than the indicated above
•Pe r sona ll y co nstr uc t ed PCs o r opera ting systems
•An environment that is an upgrade of the original manufacturer-installed operating system
•M ulti-boot environment
•Multi-monitor environment
•Macintosh
Notes
•We do not ensure trouble-fr e e ope r a tion on all computers that satisfy the system re quir e ments.
•T he NTFS format of Windows XP/Windows 2000 Professional can be used only with the standard
(factory) settings.
•We do not ensure trouble-free opera tion of the system suspend, sleep, or hibernation function on all
computers.
•For Windows 2000 Professional use rs , in sta ll Se rv ice Pack 3 or later version be fore using the
software.
•CPU: Pentium II 400 MHz or higher (Pentium III 450 MHz or higher
is recommended.)
•Hard disk drive space: 200 MB or more (1.5 GB or more is
recommended) (The am ount space will vary according t o Windows
version and the number of m usic files stored on the hard disk .)
•RAM: 64 MB or more (128 MB or more is recommended)
Others
•CD drive (capable o f di gi t al pl ayback by WDM)
Sound Board
•USB port (supports USB (previously USB 1.1))
Factory installed:
Windows XP Media Center Edition 2004/Windows XP Media Center
Edition/Windows XP Professional/Windows XP Home Edition/
Windows 2000 Professional/Windows Millennium Edition/Windows
98 Second Edition
or better is recommended)
•Windows Media Pla y er (version 7.0 or higher) installe d for playing
WMA files
SL894
(OPEN/CLOSE)
NOTES ON REPLACING THE MAIN BOARD
If the MAIN board is replaced with new part, the newly supplied
MAIN board includes the functions of the XRST board.
Accordingly, the XRST board comes unnecessary, and thus discard
the XRST board after replacing the MAIN board.
(Refer to the supplement-1 for new type MAIN board)
3
MZ-NH600D
12345
Looking at controls
The player
SECTION 2
GENERAL
This section is extracted from
instruction manual.
A x (stop) • CANCEL button
B OPEN switch
C Display window
D DOWNLOAD button
This button allows you to record
music tracks from an audio CD in th e
CD drive of your computer to an MD
Walkman using the supplied MD
Simple Burner Ver. 2.0 software.
E •NAVI/MENU button
Press lightly to go to the NAVI
(navigation) setting mode.
Press for 2 seconds or more to go to
the MENU setting mode.
F GROUP button
G X (pause) button
H Jog dial
I 5-way control key
OperationFunction
Press NENT
Press towards . find the beginning
Press towards > find the beginning
Press towards
VOL +
VOL −
1)
There are tactile do ts beside the NENT
and
The display window of the player
1)
or
VOL +
1)
play, enter
of the previous
track, rewind
of the next track,
fast forward
volume
buttons.
J USB cable connecting jack
K Battery compartment
(at the bottom)
L HOLD switch
Slide the switch in the direction of the
arrow to disable the buttons on the
player.
To prevent the buttons from being
accidentally operated when you carry
the player, use this function.
M i (headphones/earphones) jack
A Character information displ ay
Displays the disc and track names,
date, error messages, track numbers,
etc.
B Hi-MD/MD indication
“Hi-MD” lights up when the
operation mode of the player is in HiMD mode and “MD” lights up w he n
the operation mode is in MD mode.
C REC indication
Lights up during file transfers from
the computer. When flashing, the
player is in record standby mode.
4
678
D Battery indication
Shows the approximate remaining
battery power. If the battery is weak,
the indication becomes empt y and
starts flashing.
E Disc indication
Shows that the disc is rotating for
playing.
F Track mode (PCM, Hi-SP, Hi-LP, SP,
LP2, LP4, MONO) indication
G Sub play mode/Repeat play
indications
Shows the selected Sub play mode
(single-track play, shuffle play, etc.) or
Repeat play.
H Main play mode indications
Shows the selected main play mode
(group play, bookmark play, etc.).
• This set can be disassembled in the order shown below.
3-1. DISASSEMBLY FLOW
Note 1: The process described in can be performed in any order.
Note 2: Without completing the process described in , the next process can not be performed.
SET
3-2. CASE (LOWER) SECTION
(Page 6)
MZ-NH600D
SECTION 3
DISASSEMBLY
3-3. MAIN BOARD
(Page 6)
3-5. MECHANISM DECK SECTION (MT-MZNH900-181),
MD STANDARD PIN
(Page 7)
3-7. GEAR (BSA), GEAR (SB)
(Page 8)
3-8. OP SERVICE ASSY
(Page 9)
3-9. DC MOTOR SSM18D/C-NP (SPINDLE) (M701),
DC MOTOR (SLED) (M702),
DC MOTOR UNIT (OVER WRITE HEAD UP/DOWN) (M703)
(Page 9)
3-4. CASE (UPPER) SECTION
(Page 7)
3-6. SET CHASSIS ASSY
(Page 8)
3-10. HOLDER ASSY
(Page 10)
5
MZ-NH600D
3-2. CASE (LOWER) SECTION
1
two screws
(M1.4)
1
two screws
(M1.4)
3-3. MAIN BOARD
3
motor flexible board
(CN701)
2
Remove the case (lower) section
in the direction of the arrow.
2
LCD module flexible board
(CN471)
8
OP flexible board
(CN501)
1
Remove two solders of over
write head flexible board.
9
MAIN board
5
leaf spring (USB)
4
screw (M1.4)
7
6
three screws
(M1.4)
6
MZ-NH600D
3-4. CASE (UPPER) SECTION
7
case (upper) section
6
boss
3
torsion spring
(pop up L)
1
LCD module flexible boaed
(CN471)
5
4
two step screws
2
Open the case (upper) section.
3-5. MECHANISM DECK SECTION (MT-MZNH900-181), MD STANDARD PIN
1
two step screws (MD)
2
3
MD standard pin
mechanism deck section
(MT-MZNH900-181)
7
MZ-NH600D
3-6. SET CHASSIS ASSY
2
extension spring (R)
5
two screws
1
torsion coil spring (R)
7
set chassis assy
3
compression coil spring (open)
3-7. GEAR (BSA), GEAR (SB)
5
gear (SB)
4
open slider
1
self tap screw
2
thrust retainer spring
3
washer (0.8-2.5)
4
gear (BSA)
6
battery case
8
3-8. OP SERVICE ASSY
1
Lead screw service assy is turned
and it removes from OP service assy.
2
OP service assy
MZ-NH600D
3-9. DC MOTOR SSM18D/C-NP (SPINDLE) (M701), DC MOTOR (SLED) (M702),
DC MOTOR UNIT (OVER WRITE HEAD UP/DOWN) (M703)
3
two screws (M1.4)
4
DC motor (sled)
2
Remove two solders of flexible board.
8
self tap screw
9
DC motor unit
(over write head up/down)
(M703)
(M702)
1
Remove four solders of flexible board.
6
three self tap screws
7
DC motor SSM18D/C-NP
(spindle) (M701)
5
motor base assy
9
MZ-NH600D
3-10. HOLDER ASSY
4
Remove the holder assy
to the direction of the arrow
3
Open the holder assy.
1
boss
A
.
2
boss
A
10
SECTION 4
TEST MODE
MZ-NH600D
Ver 1.1
OUTLINE
A key having no particular description in the text, indicates a set
key.
1. ENTERING THE TEST MODE
Preparation:
Copy the “TestMode_Enter_For_900_800_700_600_600D_
Ver***.exe” folder of the PC application of the latest version to
your PC in advance. (operating system: Windows 2000, Windows
XP)
Also, when using this application, the SonicStage Ver. 2.0 or 2.1 is
necessary, and install it in your PC in advance.
Procedure:
1. If a Simple Burner has run on the PC, finish it (including the
one that is resident in the task tray).
2. Start the “TestMode_Enter_For_900_800_700_600_600D_
Ver***.exe”.
3. Apply the voltage of 1.5V to the battery terminals (CL431:
BA TT+, CL432: BATT−) by the regulated dc power supply.
4. Open and close the top panel of the main unit to wait until the
system reading finished.
5. Connect the main unit and PC by USB cable.
6. Check by device manager screen from property of “My
computer” that the set is recognised to your PC normally.
7. Click the [Enter TestMode] button on the screen of application
8. Disconnect the USB cable, when “OK” message is displayed
on the application screen.
9. Disconnect the power supply.
2. OPERATION IN SETTING THE TEST MODE
• When the test mode becomes active, first the Display Check
mode is selected.
• Other mode can be selected from the Display Check mode.
• When the test mode is set, the LCD repeats the following
display.
Display check mode:
Hi-MD
REC
SYNC
Hi-SPLP
All lit
All off
Microcomputer
version
display
007
Ver *.***
“*.***”: Microcomputer version
24
PCMMONO
1SHUFA-B PGM
• When the X key is pressed and hold down, the display at that
time is held so that display can be checked.
Screen of the PC application “TestMode_Enter_For_900_800_
700_600_600D_Ver***.exe”
(“***” is version number)
Note: Once the test mode is activated with this application, the test mode
is then activated forcibly by only turning on the power.
After the repair completed, be sure to release the test mode by using
this application once more.
3. RELEASING THE TEST MODE
Procedure:
1. If a Simple Burner has run on the PC, finish it (including the
one that is resident in the task tray).
2. Start the “TestMode_Enter_For_900_800_700_600_600D_
Ver***.exe”.
3. Apply the voltage of 1.5V to the battery terminals (CL431:
BA TT+, CL432: BATT−) by the regulated dc power supply.
4. Open and close the top panel of the main unit to wait until the
system reading finished.
5. Connect the main unit and PC by USB cable.
6. Check by device manager screen that the set is recognised to
your PC normally.
7. Click the [Exit TestMode] button on the screen of application
8. Disconnect the USB cable, when “OK” message is displayed
on the application screen.
9. Disconnect the power supply.
11
MZ-NH600D
Ver 1.1
4. CONFIGURATION OF THE TEST MODE
Flow of the test mode:
Display Check Mode
007
Ver *.***
[VOL +]
key
Version display
→
All off → Version display...
Manual Mode
0
Manual
key
x
Overall Adjustment Mode
[VOL --]
key
0
AdjF**
key
x
Key Check Mode
[GROUP]
Open the lid
>
key
key
114
10
Self-Diagnosis Result Display Mode
0
1 0000
key
x
Sound Skip Check Result
Display Mode (Play)
N ENT
key
0
P00r00
key
x
Sound Skip Check Result
[T MARK]
or
[REC]
key
switch
Display Mode (REC)
0
p00R00
key
x
Key Count Mode
[NAVI/MENU]
key
001
MENU 000
keyor
(press a few seconds)
>.
→
All lit
5. MANUAL MODE
This is mode to adjust or check the operation of the set by function.
Operation of The Manual Mode
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to activate the Manual mode where the
LCD displays as shown below.
Display
0
Manual
Number of 1000th place
3. During each test, the optical pick-up moves outward or inward
while the > or . key is pressed for several seconds
respectively.
4. Each test item is assigned with a four-digit item number; 1000th
place is a top item, 100th place is a major item, 10th place is a
medium item, and unit place is a minor item.
The values adjusted in the test mode are written to the nonvolatile memory (for the items where adjustment was made).
5. To quit the Manual mode, press the x key and return to the
Display Check mode.
Flow of manual mode operation:
[VOL +]
Top item switching
key
>
Major item switching
key
>
Medium item switching
key
>
Minor item switching
key
x
key
x
key
x
key: 1000th place of item
number increase.
[VOL --]
key: 1000th place of item
number decrease.
[VOL +]
key: 100th place of item
number increase.
[VOL --]
key: 100th place of item
number decrease.
[VOL +]
key: 10th place of item
number increase.
[VOL --]
key: 10th place of item
number decrease.
key: 1st place of item
>
.
number increase.
key: 1st place of item
number decrease.
12
(Not used in servicing)
Adjusted value variation
[VOL +]
key: Increases the adjusted
value.
[VOL --]
key: Decreases the adjusted
value.
Adjusted value write
key: Adjusted value is written.
X
MZ-NH600D
Ver 1.1
6. OVERALL ADJUSTMENT MODE
6-1. Operation of The Overall Adjustment Mode
1. Enter the test mode (Display Check mode).
2. Press the [VOL--] key to activate the Overall Adjustment mode
where the LCD displays as shown below.
Display
0
AdjF**
Disc mark:
Lit the inner segments: Completed the power supply adjustment.
Lit the outer segments: Completed the charge function check.
“**”:
If “DF” or “FF” is displayed, it mean that completed the servo
overall adjustment.
3. To quit the Overall Adjustment mode, press the x key and
return to the Display Check mode.
Flow of overall adjustment mode:
Overall Adjustment Mode
0
AdjF**
CD Overall Adjustment Mode
key
.
***
CD Run
key
x
6-2. Error Message in The Overall Adjustment Mode
In the Overall Adjustment mode, if an error occurred, it displa ys as
following table.
DisplayDescription
Close!Dose not close the lid
DfDis!Unsuitableness disc was inserted
NoChg!Does not finish the charge function check
NoTmp!Does not setting the temperature correction value
NotCD!Does not complete the CD Overall adjustment beforethe
MD1 Overall adjustment
NotM1!Does not complete the MD1 Overall adjustment
before the Hi-MD3 Overall adjustment
NotH3!Does not complete the Hi-MD3 Overall adjustment
before the Stray Light Offset Overall adjustment
****NGError of item number “****”
7. SELF-DIAGNOSIS RESULT DISPLAY MODE
This set uses the self-diagnostic function system in which if an error
occurred during the recording or playing, the mechanism control
block and the power supply control block in the microcomputer
detect it and record its cause as history in the nonvolatile memory.
By checking this history in the test mode, you can analyze a fault
and determine its location.
Total recording time is recorded as a guideline of how long the
optical pick-up has been used, and by comparing it with the total
recording time at the time when an error occurred in the selfdiagnosis result display mode, you can determine when the error
occurred.
Clear the total recording time, if the optical pick-up was replaced.
key
>
key
x
[VOL +]
key
x
[VOL --]
key
x
[GROUP]
key
x
[T MARK]
[REC]
or
key
x
key
key
key
key
switch
MD1 Overall Adjustment Mode
***
MD1Run
Hi-MD3 Overall Adjustment Mode
***
HM3Run
Stray Light Offset Overall
Adjustment Mode
***
OfsRun
Optical Pick-up Operation
Check Mode
000
OPChk
Initialize The Adjustment Values
911
ResOK?
(rotation)
7-1. Operation of The Self-Diagnosis Result Display
Mode
1. Enter the test mode (Display Check mode).
2. Press the > key to activate the Self-Diagnosis Result Display
mode where the LCD displays as shown below.
Display
***
$$####
“***”: Error code
“$$”: Error history code
“###”: Total recording time
3. To quit the Self-Diagnosis Result Display mode, press the x key
and return to the Display Check mode.
13
MZ-NH600D
Ver 1.1
Flow of Self-diagnosis Result Display mode operation:
***
1 ####
[VOL --]
[VOL +]
key
key
***
N ####
[VOL --]
[VOL +]
key
key
***
N1####
[VOL +]
key
[VOL --]
key
***
N2####
[VOL +]
key
[VOL --]
key
***
R_####
[VOL +]
key
7-2. Error Code of The Self-Diagnosis Result Display
Mode
[VOL --]
key
The first error
The last error
One error before
the last
Two error before
the last
Total recording time
8. KEY CHECK MODE
This mode is used for key check.
Operation of The Key Check Mode
1. Enter the test mode (Display Check mode).
2. Press the [GROUP] key to acti vate the K ey Check mode where
the LCD displays as shown below.
Display
114
$$$$$$
“$$$$$$”:Pressed key name.
When the jog dial is turned, it displays “JOG+ X” or “JOG-X” (“X” is number of 1 to 3). If the jog dial is turned four
click, it displays “JOG+OK” or “JOG-OK”.
3. When all keys (*1) check is OK on the main unit, it displays
as follows.
Display
888
SET OK ##
*1) Turn the jog dial four click clockwise and counterclockwise to
jog test is OK.
4. When all keys check are OK, it display backs to the Display
Check mode automatically.
5. To quit the Key Check mode, open the lid and return to the
Display check mode.
Error codeDescription
00No error
01Attempt to access an abnormal address
02High temperature detected
03Focus error (no change)
04Abnormal rotation of disc
05Fault of disc discriminate
06Error of access loop (no change)
07Error of access loop (with change)
08Could not read address
09Focus error (with change)
12Could not read data with SYNC
13TOC address data error
32Focus error, ABCD offset error
33Tracking error, offset error
34Tracking error, X1 tracking error, offset error
7-3. Clear The Total Recording Time
After replacing the optical pick-up, clear the total recording time.
1. Enter the test mode (Display Check mode).
2. Press the > key to activ ate the Self-Diagnosis Result Display
mode.
3. Press the [VOL--] key once to display the total recording time
indication.
4. Press the X key and display “ClrOK?”.
5. Press the X key again to display “RecT 0” and clear the total
recording time.
14
SECTION 5
ELECTRICAL ADJUSTMENTS
MZ-NH600D
Ver 1.1
1. PRECAUTIONS FOR ADJUSTMENT
1. Adjustment must be done in the test mode only. After adjusting,
release the test mode. A key having no particular description
in the text, indicates a set key.
2. Use the following tools and measuring instruments.
• Digital voltmeter
• Regulated dc power supply (two sets)
• Thermometer (using the Temperature Correction)
• Laser power meter
• CD adjustment disc TDYS-1 (Part No. : 4-963-646-01)
• PC application software for test mode
“TestMode_Enter_F or_900_800_700_600_600D_V er***.exe” *2
• USB cable
*1) Hi-MD3 adjustment disc (HMD1GSDJ) is consumable.
Therefore if it is used 400 times, exchange it for a new.
*2) Use the newest version every time.
Copy the whole folder of this program to your PC.
Operating system: Windows 2000, Windows XP
When using this application, the SonicStage Ver. 2.0 or 2.1 is
necessary, and install it in your PC in advance.
3. Unless specified otherwise, supply DC 1.5 V from battery
terminals (CL431: BATT+, CL432: BATT–).
2. ADJUSTMENT SEQUENCE
Adjustment must be done with the following order.
Adjustment order:
1. Entering the test mode
2. Initialize the adjustment value
3. Setting the temperature correction value
4. Power supply voltage adjustment
5. Laser power check
6. Setting the adjustment values
7. Servo Overall adjustment
8. Resume clear
9. Releasing the test mode
3. ADJUSTMENT OF THE EACH ITEM
3-1. Entering The Test Mode
Refer to the “SECTION 4. TEST MODE”.
3-3. Setting The Temperature Correction Value
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the > key twice, and press the [VOL+] key twice to
display as follows.
Display
130
Temp
3. Press the > key once to select the item number 0131 and
display as follows.
Display
131
###S**
adjustment value (hexadecimal)
4. Measure the ambient temperature.
5. Adjust with [VOL+]/[VOL--] keys so that the adjusted value
(hexadecimal value) becomes the ambient temperature.
(example: 25 °C = 19h)
6. Press the X key to write the adjusted value.
7. Press the x key four times and back to the Display Check
mode.
3-4. Power Supply Voltage Adjustment
Adjustment must be done with the following order.
3-4-1. Setting
Procedure:
1. Enter the test mode (Display Check mode), and make sure
that the power supply voltage is 1.2 V.
2. Press the [VOL+] key to enter the Manual mode.
3. Press the [VOL+] key twice to display as follows.
Display
2
POWER
3-2. Initialize The Adjustment Value
Procedure:
1. In the test mode (Display Check mode), press the [VOL--] key
to enter the Overall adjustment mode.
2. Press the [T MARK] key and display “911 ResOK?”.
3. Press the X key to display “911 Reset!” and initialize the
adjustment values.
4. Press the x key and back to Display Check mode.
4. Press the > key once, press the [VOL+] key once, and press
the > key once again to display as follows.
Display
210
PwrAdj
5. Repeat the next procedures (3-4-2. PwrAdj Adjustments), and
adjust all contents of “table 3-4-1. PwrAdj Specifications”.
15
MZ-NH600D
9
Ver 1.1
3-4-2. PwrAdj adjustments
Repeat the following procedures and adjust all contents of “table 34-1. PwrAdj Specifications”.
Example Display (Item No. 2211)
211
AD **
adjustment value (hexadecimal)
Procedure:
1. Connect the digital voltmeter to measuring point (refer to the
following table) and ground (CL433).
2. Press the > key to change the item number.
3. Adjust with [VOL+]/[VOL--] keys so that the value of digital
voltmeter becomes specification value.
4. Press the X key to write the adjusted value.
5. Press the > key to select the next item.
6. Repeat adjustment from step 1 until item number 2233.
Adjustment Location:
ItemNo.DisplaySpecification valueMeasuring point
2211211 AD **2.05 V + 0.02 VCL8027
2212212 AD **2.25 V ± 0.01 VCL8027
2213213 AD **1.20 V + 0.01 VCL8001
2214214 AD **3.10 V ± 0.015 VCL658
2215215 AD **3.10 V ± 0.015 VCL658
2216216 AD **3.02 V ± 0.02 VCL919
2217217 AD **3.02 V ± 0.02 VCL919
2218218 AD **2.275 V ± 0.01 VCL921
2219219 AD **2.480 V ± 0.01 VCL921
2221221 AD **2.740 V ± 0.01 VCL921
2222222 AD **2.985 V ± 0.01 VCL921
2223223 AD **2.52 V ± 0.02 VCL931
2224224 AD **0.89 V ± 0.02 VCL604
2225225 AD **1.08 V ± 0.02 VCL604
2226226 AD **1.52 V ± 0.02 VCL604
2227227 AD **2.27 V ± 0.02 VCL604
2228228 AD **2.97 V ± 0.02 VCL604
2229229 AD **0.94 V ± 0.02 VCL604
2231231 AD **1.28 V ± 0.02 VCL604
2232232 AD **2.57 V ± 0.02 VCL604
2233233 AD **2.57 V ± 0.02 VCL604
Note1: “**” is adjustment value (hexadecimal number).
Note2: Ground point of all measuring points is CL433.
1. In the “3-4-2. PwrAdj Adjustments” completed status, press
the > key to display as follows.
Display
240
VBsAdj
2. Apply the voltage of 5 V to the CL453 (VBUS 5V) and CL460
(VBUS GND).
3. Press the > key to change the item number to 2241.
4. Adjust with [VOL+]/[VOL--] keys so that the value of digital
voltmeter becomes specification v alue. (refer to “table 3-4-2.
VBsAdj Specifications”)
5. Press the X key to write the adjusted value.
6. Press the > key to select the next item, and repeat
adjustments to item number 2243 at the same manner as step
3 to step 5.
Item No.DisplaySpecification valueMeasuring point
2241241 AD **1.13 V ± 0.01 VCL8001
2242242 AD **2.05 V + 0.02 VCL8027
2243243 AD **3.30 V ± 0.01 VCL8055
Note1: “**” is adjustment value (hexadecimal number).
Note2: Ground point of all adjustment points is CL433.
Note3: Refer to page 18 for adjustment location.
Table 3-4-2. VBsAdj Specifications
7. Press the > key to select the item number 2244, and turn
off the power supply of battery terminal.
8. Adjust with [VOL+]/[VOL--] keys so that the v oltage of between
CL935 and CL433 (GND) becomes 1.80 V (− 0.02 V).
9. Press the X key to write the adjusted value.
10. Apply the voltage of 1.2 V to the battery terminal again.
11. Press the x key to display “240 VBsAdj” (Item number:
2240).
12. Turn off the voltage of 5 V to the CL453 (VBUS 5V) and
CL460 (VBUS GND).
13. Press the x key three times and back to the Display Check
mode.
3-5. Laser Power Check
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Open the lid and press the . key continuously until the
optical pick-up moves to the most inward track.
3. Set the laser power meter so that the laser beam from the optical
pick-up aims at the objective lens of laser po wer meter at right
angle.
4. Press the [VOL--] key once to display as follows.
Display
9
DESIGN
5. Press the > key three times to select the item number 9111
and display as follows.
Display
111
###S**
6. Confirm that the value of laser power meter is 0.67 mW ±
21%.
7. Press the > key to select the item number 9112.
8. Confirm that the value of laser power meter is 0.76 mW ±
18%.
9. Press the > key to select the item number 9113.
10. Confirm that the value of laser power meter is 6.25 mW ±
12%.
11. Press the x key four times and back to the Display Check
mode.
3-6. Setting The Adjustment Values
3-6-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the > key once, press the [VOL+] key once, and press
the > key once again to display as follows.
Display
210
DiscPr
3. Press the > key once to select the item number 0211.
4. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of LCD becomes calculated value.
5. Press the X key to write the adjusted value.
6. Press the > key to next item.
7. Repeat adjustment from step 4 until item number 0216.
3-7. Servo Overall Adjustment
Note1: Be sure to adjustment so that the set is horizontal and the LCD is
upside. Unless performed in that state, it is not adjusted correctly.
Note2: If NG is displayed in the middle of this adjustments, perform “3-2.
Initialize The Adjustment Value” and “3-6. Setting The Adjustment
Values” again, then retry this adjustments from step 1.
Procedure:
1. Apply the voltage of 1.5V to the battery terminals (CL431:
BA TT+, CL432: BATT−), then open and close the lid and enter
the test mode (Display Check mode).
2. Press the [VOL--] key to enter the Overall Adjustment mode.
3. Insert the CD adjustment disc (TDYS-1).
4. Put the main unit horizontal so that the LCD becomes upside,
and press the . key.
5. Wait until “CD OK” is displayed on the LCD.
6. Insert the MD1/HiMD1 hybrid adjustment disc
(MDW-74/GA1).
7. Put the main unit horizontal so that the LCD becomes upside,
and press the > key.
8. Wait until “MD1 OK” is displayed on the LCD.
9. Insert the Hi-MD3 adjustment disc (HMD1GSDJ).
10. Put the main unit horizontal so that the LCD becomes upside,
and press the [VOL+] key.
11. Wait until “HMD OK” is displayed on the LCD.
12. Eject the disc.
13. Put the main unit horizontal so that the LCD becomes upside,
and press the [VOL--] key.
14. Wait until “OfstOK” is displayed on the LCD.
15. Press the x key and back to the Display Check mode.
3-6-2. Other setting
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the > key five time to select the item number 0113
and display as follows.
Display
113
###S**
adjustment value (hexadecimal)
3. Press the [VOL+]/[VOL--] key and set the according value to
each model type and destination referring to the following
table.
4. Press the X key to write the adjusted value.
Destination
US0840
Canadian0840
Ver. 1.000Other version
Table 3-6-2. Destination and Version Setting
Version
3-8. Resume Clear
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the [VOL+] key once, press the > key once , press the
[VOL--] ke y once, press the > key once, and press the [VOL+]
key twice, press the > key three times to select the item
number 1933.
3. Press the X key to resume clear.
4. Press the x key four times and back to the Display Check
mode. And disconnect the power supply.
3-9. Releasing The Test Mode
Refer to the “SECTION 4. TEST MODE”.
Note: Once the test mode is activated with this application, the test mode
is then activated forcibly by only turning on the power.
After the repair completed, be sure to release the test mode by using
this application once more.
5. If the version of adjusting set is “1.000”, refer to the following
table and set the value to each item number at the same mannar .
• Note For Printed Wiring Boards and Schematic Diagrams
Note on Printed Wiring Board:
• X : parts extracted from the component side.
• Y : parts extracted from the conductor side.
•: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
Caution:
Pattern face side:Parts on the pattern face side seen from
(Conductor Side)the pattern face are indicated.
Parts face side:Parts on the parts face side seen from
(Component Side) the parts face are indicated.
• Main board is multi-layer printed board.
However, the patterns of intermediate-layer have not been included in this diagrams.
• Lead Layouts
Lead layout of conv entional ICCSP (chip size package)
surfac
Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted. (p: pF)
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in Ω and 1/
specified.
•f: internal component.
• C : panel designation.
Note:
The components identified by mark 0 or dotted
line with mark 0 are critical for safety.
Replace only with part
number specified.
• A : B+ Line.
• Total current is measured with MD installed.
• Power voltage is dc 1.5 V and fed with regulated dc power
supply from battery terminal.
• Voltages and wa vef orms are dc with respect to ground in
playback mode.
no mark : PLAYBACK
• Voltages are taken with a V OM (Input impedance 10 MΩ).
Voltage variations may be noted due to normal production tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production tolerances.
• Circled numbers refer to waveforms.
• Signal path.
E: PLAYBACK
j: REC
F: USB input from PC
f: USB output to PC
• Abbreviation
CND : Canadian model
4
W or less unless otherwise
Note:
Les composants identifiés par
une marque 0 sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce portant le numéro
spécifié.