PAL, PAL60 (only video input), SECAM, NTSC 3.58, NTSC 4.43 (only video input)
B/G:VHF: E2 to E12/ UHF: E21 to E69/ CATV: S01 to S03, S1 to S41
VHF: 0 to 12, 5A, 9A/ UHF: 28 to 69/ CATV: S01 to S03, S1 to S44 (Australia only)
VHF: 1 to 11/ UHF: 21 to 69/ CATV: S01 to S03, S1 to S41 (New Zealand only)
I: UHF: B21 to B69/ CATV: S01 to S03, S1 to S41
D/K:VHF: C1 to C12, R1 to R12/ UHF: C13 to C57, R21 to R60/ CATV: S01 to S03, S1
to S41, Z1 to Z39
M: VHF: A2 to A13/ UHF: A14 to A79/ CATV: A-8 to A-2, A to W+4, W+6 to W+84
Video: 1080/24p, 1080p, 1080i, 720p, 576p, 576i, 480p, 480i
Audio: Two channel linear PCM: 32, 44.1 and 48 kHz, 16, 20 and 24 bits
Analogue audio input (minijack) (HDMI IN 1 only)
PC Input
Audio output (phono jacks)
PC Input (D-sub 15-pin)
G: 0.7 Vp-p, 75 ohms, non Sync on Green/B: 0.7 Vp-p, 75 ohms/
R: 0.7 Vp-p, 75 ohms/HD: 1-5 Vp-p/VD: 1-5 Vp-p
PC audio input (minijack)
DIGITAL MEDIA PORT
USB port
Headphones jack
10BASE-T/100BASE-TX connector (Depending on the operating environment of the
network, connection speed may differ. 10BASE-T/100BASE-TX communication rate
and communication quality is not guaranteed for this TV.)
110 - 240V AC, 50/60 Hz
40 inches (Approx.
101.6cm)
1,920 dots (horizontal) × 1,080 lines (vertical)
210 W270 W370 W
230 W350 W480 W
0.2 W (19 W when “Quick
Start” is set to “On”)Start” is set to “On”)Start” is set to “On”)
* Specified standby power is reached after the TV finishes necessary internal processes.
Design and specifications are subject to change without notice.
PC input signal reference chart for PC and HDMI In 1, 2, 3, 4
Resolution
SignalsHorizontal
VGA
SVGA
XGA
WXGA
SXGA
HDTV
(Pixel)
640×48031.560VGA
640×48037.575VESA
720×40031.570VGA-T
800×60037.960VESA Guidelines
800×60046.975VESA
1024×76848.460VESA Guidelines
1024×76856.570VESA
1024×76860.075VESA
1280×76847.460VESA
1280×76847.860VESA
1280×76860.375
1360×76847.760VESA
1280×102464.060VESA
1920×108067.560CEA-861*
× Vertical
(Line)
Horizontal
frequency (kHz)
Vertical
frequency (Hz)
Standard
* 1080p timing when applied to the HDMI input will be treated as a video timing and not a PC timing. This
affects the “Video Settings” menu and “Screen” menu settings.
To view PC contents, set “Game/Text Mode” to “On”, “Wide Mode” to “Full”, and “Display Area” to “Full
Pixel”.
This TV’s PC input does not support Sync on Green or Composite Sync.
This TV’s PC input does not support interlaced signals.
For the best picture quality, it is recommended to use the signals (boldfaced) in the above chart with a 60 Hz
vertical frequency.
KLV-40/46/55X450A (E, GE) 3
WARNINGS AND CAUTIONSSAFETY-RELATED COMPONENT
10/30/2018
Digitized in Heiloo the Netherlands
Not for sale!
CAUTION
These servicing instructions are for use by qualified service
personnel only.
To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you
are qualified to do so.
WARNING!!
WARNING
It is essential that all critical parts be replaced only with the part
number specified in the electrical parts list to prevent electric
shock, fire, or other hazard.
NOTE: Do not modify the original design without obtaining
written permission from the manufacturer or you will
void the original parts and labor guarantee.
An isolation transformer should be used during any service to
avoid possible shock hazard, because of live chassis.
The chassis of this receiver is directly connected to the ac power
line.
! SAFETY-RELATED COMPONENT
WARNING!!
Replace all components with Sony parts whose part numbers
appear as shown in this manual or in supplements
published by Sony.
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by
using a wrist band.
When repairing the LCD panel on the wall, the LCD panel must
be secured using the 4 mounting holes on the rear cover.
1) Do not press on the panel or frame edge to avoid the risk of
electric shock.
2) Do not scratch or press on the panel with any sharp objects.
3) Do not leave the module in high temperatures or in areas of
high humidity for an extended period of time.
4) Do not expose the LCD panel to direct sunlight.
5) Avoid contact with water. It may cause a short circuit within
the module.
6) Disconnect the AC power when replacing the backlight (CCFL)
or inverter circuit.
(High voltage occurs at the inverter circuit at 650Vrms.)
7) Always clean the LCD panel with a soft cloth material.
8) Use care when handling the wires or connectors of the inverter
circuit. Damaging the wires may cause a short.
9) Protect the panel from ESD to avoid damaging the electronic
circuit (C-MOS).
KLV-40/46/55X450A (E, GE) 4
SAFETY CHECK-OUT
l
t
µ
d
AC
)
t
Col
pe
.
10/30/2018
Digitized in Heiloo the Netherlands
Not for sale!
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly
soldered connections. Check the entire board surface for
solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are
“pinched” or touching high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps,
and mounting hardware have been replaced. Be absolutely
certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly
transistors, that were installed during a previous repair. Point
them out to the customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious
signs of deterioration. Point them out to the customer and
recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend
the replacement of any such line cord to the customer.
7. Check the antenna terminals, metal trim, “metallized”
knobs, screws, and all other exposed metal parts for AC
leakage. Check leakage as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part
having a return to chassis, must not exceed 0.5 mA (500
microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or
RCA WT-540A. Follow the manufacturers’ instructions to
use these instructions.
2. A battery-operated AC milliampmeter. The Data Precision
245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit”
indication is 0.75 V, so analog meters must have an accurate
low voltage scale.
The Simpson’s 250 and Sanwa SH-63TRD are examples of
passive VOMs that are suitable. Nearly all battery-operated
digital multimeters that have a 2 VAC range are suitable (see
Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate
retaining screw on most AC outlet boxes is also at earth ground.
If the retaining screw is to be used as your earth ground, verify
that it is at ground by measuring the resistance between it and a
cold-water pipe with an ohmmeter. The reading should be zero
ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt
trouble- light (not a neon lamp) between the hot side of the
receptacle and the retaining screw. Try both slots, if necessary,
to locate the hot side on the line; the lamp should light at normal
brilliance if the screw is at ground potential (see Figure B).
Exposed Meta
Parts on Se
ouble Ligh
AC Outlet Box
.15
0.75V
Earth Groun
Ohmmeter
FigureA. Using an AC voltmeter to check AC leakage. Figure B. Checking for earth ground
d-water Pi
KLV-40/46/55X450A (E, GE) 5
SELF DIAGNOSIS FUNCTION
10/30/2018
Digitized in Heiloo the Netherlands
Not for sale!
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash.
The number of times the LED flashes translates to a probable source of the problem.
A definition of the STANDBY LED flash indicators is listed in the instruction manual for the user’s knowledge and reference.
If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to
reveal past problems and how often these problems occur.
DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY LED will flash a set number of times to indicate the possible cause of the problem.
If there is more than one error, the LED will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen.
If the screen displays a “0”, no error has occurred .
Number of times STANDBYMonitoring Items
LED (Red) flashes(Screen Display)
2 timesPOW_ERR1AAS Board IC2104
79pin: i_lb_err (AD port) < PW_ERR_LEV (Threshold Value)
and
138pin: i_ac_off_det: HIGH
5 timesT_CONFBA Board IC5501
1128Pin: TCON_RDY: Low
or
2Detected Error of Cayenne Register
6 timesBACKLITEFBA Board IC5501
78Pin: INV_FAIL: LOW
7 timesPANLTEMPFBA Board IC5501
IIC_ch2 setting value (BEM data)
8 timesAUD_PROTAAS Board IC2104
19pin: i_au_prot: Low
9 timesFAN_ERRFBA Board IC5501
pin154: FAN_ERR: High
13 timesBALANCERFBA Board IC5501
1163pin: BALANCER_ERR: LOW
or
2SPI_ERR_CNT (SetSREG) >= SPI_ERR_LIM (FactSREG)
Detection
DISPLAY OF STANDBY LIGHT FLASH COUNT
[ FLASH COUNT ]
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
Note: One flash counts is not self-diagnostic.
STANDBY LED
LED OFF
2 sec.
STOPPING THE STANDBY FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY LED for flashing.
KLV-40/46/55X450A (E, GE) 6
SELF-DIAGNOSTIC SCREEN DISPLAY
10/30/2018
Digitized in Heiloo the Netherlands
Not for sale!
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to
bring up past occurrences of failure for confirmation on the screen:
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
5
( Info/Text reveal )
( Number button )
* ( Volume ) ( TV standby )
* : Note that this differs from entering the service mode (volume +)
Panel operation time by hour (max 99999)
Boot count (max 99999)
Total operation time by hour (max 99999)
The last failure time
Falure time before last
Last failure time beforehand
Error count (00-99)
Item name
Frequency of LED blinking.
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen
After you have completed the repairs, clear the result display to “0”.
Clearing the result display
To clear the result display to “0”, press button on the remote commander sequentially as shown below when the diagnostic screen is being
displayed.
<Delection of Error Count and Error History>
Press “8” button , Press “-” button
<Delection of Panel Operation Time>
Press “7” button , Press “-” button
Quitting Self-diagnostic screen
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.