MODIFICATION
# No. DATA CONTENTS
#1 2000.2 Adds omitted parts numbers. (P.7-1, 7-2, 7-3, 7-4, 7-5, 7-6, 7-7, 7-8, 7-9, 7-10, 59)
HISTORY
MODEL NAME :
HMD-A200/HMD-A220 SERVICE MANUAL PARTS No. : 9-978-661-05
* Blue characters are linking.
#2 2000.2 Alteration of parts supply, as the service division had changed. (P.6-1, 6-2) #3 2000.3 Decide on part number (IC901 on D board). (P.7-7) #4 2000.3 Parts number clerical error correction (C625 on D board). (P.7-4) #5 2000.5 Add omitted part (LABEL, INFORMATION). (P.6-1) #6 2000.8 Because a VAIO color model was added, ten parts were ad ded to the Exploded Views.
(P.6-1, 6-2) #7 2000.11 Parts number clerical error correction (Q517, Q5H1 on D board). (P.7-7) #8 2000.11 Correction and modification due to addition of model name. (HMD-A220)
(P.6-1, 6-2)
#9 2000.12 Parts number clerical error correction.
(P.5-11, 5-12, 5-15, 5-16, 5-17, 5-18, 5-19, 5-20, 6-2, 7-1, 7-3, 7-4, 7-5, 7-6, 7-7, 7-8, 7-9 )
#10 2001.3 Parts number clerical error correction.
BEZEL ASSY(HMD-A220) X-4038-204-1 X-4038-207-1 (P.6-1)
#11 2001.3 Part numbers of BEZEL ASSY for J destination were registered as usual, and those
for U/C destination were newly registered.
BEZEL ASSY(VAIO color)
J: X-4038-448-1[With VAIO logo]
U/C: X-4039-027-1[Without VAIO logo] (P .6-1)
#12 2001.3 Parts number clerical error correction (FB013 on A board). (P.7-2)
HMD-A200/HMD-A220
* Recommended horizontal and vertical timing condition
• Horizontal sync width should be more than 1.0 µsec.
• Horizontal blanking width should be more than 3.0 µsec.
• Vertical blanking width should be more than 500 µsec.
Design and specifications are subject to change without notice.
HMD-A200
SERVICE MANUAL
SPECIFICATIONS
CRT 0.24 mm aperture grille pitch
17 inches measured diagonally 90-degree deflection
Viewable image size Approx. 327 × 243 mm (w/h)
Resolution Horizontal: Max. 1280 dots Standard image area Approx. 312 × 234 mm (w/h)
Deflection frequency* Horizontal: 30 to 70 kHz
AC input voltage/current 100 to 240 V, 50 – 60 Hz, 2.0 –
Power consumption Max. 115 W (with no USB
Operating temperature 10°C to 40°C Dimensions
Mass Approx. 19 kg (41 lb 14 oz) Plug and Play DDC1/DDC2B Supplied accessories Power cord (1)
7
/8 × 9 5/8 inches)
(12
16.0" viewing image
Vertical: Max. 1024 lines
3
/8 × 9 1/4 inches)
(12
Vertical: 48 to 120 Hz
0.9 A
devices connected) Approx. 460 × 378 × 441 mm
(18 1/8 × 15 × 17 3/8
(w/h/d) inches)
USB cable (1) Windows Monitor Information Disk (1) Monitor stand (1) Warranty card (1) Notes on cleaning the screen’s surface (1) This instruction manual (1)
US Model
Canadian Model
AEP Model
Chassis No. SCC-L27N-A
HMD-A220
AEP Model
Chassis No. SCC-L27Q-A
X11R
CHASSIS
MICROFILM
TRINITRON® COLOR COMPUTER DISPLAY
HMD-A200/A220
Power mode Power
consumption*
1 (power) indicator
normal operation
115 W green
1 standby 15 W green and orange
alternate
2 supend
3 active off**
15 W 5 W
green and orange alternate orange
power off 0 W off
DIAGNOSIS
Failure Power LED HV or +B Failure or H Stop Blink Amber (On 0.5 sec, Off 0.5 sec) V Stop Blink Amber (On 1.5 sec, Off 0.5 sec) ABL Failure Blink Amber (On 0.5 sec, Off 1.5 sec)
Aging/Self-Test Blink Amber (On 0.5 sec, Off 0.5 sec) .... Blink Green (On 0.5 sec, Off 0.5 sec)
TIMING SPECIFICATION
PRIMARY MODE MODE AT PRODUCTION RESOLUTION 640 X 480 640 X 480 720 X 400 800 X 600 800 X 600 832 X 624 1024 X 768 1024 X 768 1280 X 1024 CLOCK 25.175 MHz 36.000 MHz 28.322 MHz 49.500 MHz 56.250 MHz 57.283 MHz 78.750 MHz 94.500 MHz 108.000 MHz — HORIZONTAL — H-FREQ 31.469 kHz 43.269 kHz 31.469 kHz 46.875 kHz 53.674 kHz 49.725 kHz 60.024 kHz 68.677 kHz 63.981 kHz
H. TOTAL 31.778 23.111 31.777 21.333 18.631 20.111 16.660 14.561 15.630 H. BLK 6.356 5.333 6.355 5.172 4.409 5.586 3.657 3.725 3.778 H. FP 0.636 1.556 0.636 0.323 0.569 0.559 0.203 0.508 0.444 H. SYNC 3.813 1.556 3.813 1.616 1.138 1.117 1.219 1.016 1.037 H. BP 1.907 2.222 1.907 3.232 2.702 3.910 2.235 2.201 2.296 H. ACTIV 25.422 17.778 25.422 16.162 14.222 14.524 13.003 10.836 11.852 — VERTICAL — V. FREQ(HZ) 59.940 Hz 85.008 Hz 70.087 Hz 75.000 Hz 85.061 Hz 74.550 Hz 75.030 Hz 84.997 Hz 60.020 Hz
V. TOTAL 525 509 449 625 631 667 800 808 1066 V. BLK 45 29 49 25 31 43 32 40 42 V. FP 10112111111 V. SYNC 2 3 2 333333 V. BP 33 25 35 21 27 39 28 36 38 V. ACTIV 480 480 400 600 600 624 768 768 1024 — SYNC — INT(G) NO NO NO NO NO NO NO NO NO EXT(H/V)/POLARITY YES -/- YES -/- YES -/+ YES +/+ YES +/+ YES -/- YES +/+ YES +/+ YES +/+ EXT(CS)/POLARITY NO NO NO NO NO NO NO NO NO INT/NON INT NON INT NON INT NON INT NON INT NON INT NON INT NON INT NON INT NON INT
MODE 1 MODE 2 MODE 3 MODE 4 MODE 5 MODE 6 MODE 7 MODE 8 MODE 9
usec usec usec usec usec usec usec usec usec
lines lines lines lines lines lines lines lines lines
99.7.2 VER.
Power saving function
This monitor meets the power-saving guidelines set by VESA,
E
NERGY STAR, and NUTEK. If the monitor is connected to a computer or video graphics board that is DPMS (Display Power Management Signaling) compliant, the monitor will automatically reduce power consumption in three stages as shown right.
* Figures reflect power consumption when no USB compatible
peripherals are connected to the monitor.
**When your computer enters the “active off” mode, the input
signal is cut and NO INPUT SIGNAL appears on the screen. After 20 seconds, the monitor enters the power saving mode.
– 2 –

SAFETY CHECK-OUT

r
HMD-A200/A220
After correcting the original service problem, perform the fol­lowing safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-sol­dered connections. Check the entire board surface for solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or contact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly tran­sistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer.
7. Check the B+ and HV to see if they are specified values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC Leakage. Check leakage as described below.
To Exposed Metal Parts on Set
0.15 µF
1.5 k
AC Voltmete (0.75 V)
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part hav­ing a return to chassis, must not exceed 0.5 mA (500 microampers). Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indica­tion is 0.75 V, so analog meters must have an accurate low­voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOMs that are suitable. Nearly all battery operated digital multimeters that have a 2 V AC range are suitable. (See Fig. A)
WARNING!! NEVER TURN ON THE POWER IN A CONDITION IN WHICH THE DEGAUSS COIL HAS BEEN REMOVED.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY SHADING AND MARK
¡ ON THE SCHEMATIC DIAGRAMS, EXPLODED
VIEWS AND IN THE PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS AP­PEAR AS SHOWN IN THIS MANUAL OR IN SUPPLE­MENTS PUBLISHED BY SONY. CIRCUIT ADJUST­MENTS THAT ARE CRITICAL FOR SAFE OPERATION ARE IDENTIFIED IN THIS MANUAL. FOLLOW THESE PROCEDURES WHENEVER CRITICAL COMPONENTS ARE REPLACED OR IMPROPER OPERATION IS SUS­PECTED.
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
AVERTISSEMENT!! NE JAMAIS METTRE SOUS TENSION QUAND LA BOBINE DE DEMAGNETISATION EST ENLEVÉE.
ATTENTION AUX COMPOSANTS RELATIFS À LA
SÉCURITÉ!! LES COMPOSANTS IDENTIFIÉS PAR UNE TRAME ET UNE MARQUE
¡ SONT CRITIQUES POUR LA SÉCURITÉ.
NE LES REMPLACER QUE PAR UNE PIÈCE PORTANT LE NUMÉRO SPECIFIÉ. LES RÉGLAGES DE CIRCUIT DONT L’IMPORTANCE EST CRITIQUE POUR LA SÉCURITÉ DU FONCTIONNEMENT SONT IDENTIFIÉS DANS LE PRÉSENT MANUEL. SUIVRE CES PROCÉDURES LORS DE CHAQUE REMPLACEMENT DE COMPOSANTS CRI­TIQUES, OU LORSQU’UN MAUVAIS FONCTIONNEMENT EST SUSPECTÉ.
– 3 –
HMD-A200/A220
TABLE OF CONTENTS
Section Title Page
1. GENERAL .................................................................. 1-1
2. DISASSEMBLY
2-1. Bucket Removal .................................................. 2-1
2-2. A, D, U1 and U2 Boards Removal ..................... 2-1
2-3. H Board Removal ................................................. 2-1
2-4. Picture Tube Removal .......................................... 2-2
2-5. Harnes Location ................................................... 2-3
3. SAFETY RELATED ADJUSTMENT............. 3-1
4. ADJUSTMENTS ...................................................... 4-1
5. DIAGRAMS
5-1. Block Diagrams ................................................... 5-1
5-2. Circuit Boards Location ...................................... 5-7
5-3. Schematic Diagrams and Printed Wiring Boards ...... 5-8
(1) Schematic Diagrams of U1 and U2 Boards ........ 5-9
(2) Schematic Diagram of A Board .......................... 5-11
(3) Schematic Diagram of D Board .......................... 5-15
(4) Schematic Diagram of H Board .......................... 5-25
5-4. Semiconductors ................................................... 5-27
6. EXPLODED VIEWS
6-1. Chassis ................................................................. 6-1
6-2. Packing Materials ................................................ 6-2
7. ELECTRICAL PARTS LIST ............................ 7-1
– 4 –
The operating instructions mentioned here are partial abstracts from the Operating Instruction Manual. The page numbers of the Operating Instruction Manual remein as in the manual.
4
Precautions
Warning on power connections
• Use the supplied power cord. If you use a different power cord, be sure that it is compatible with your local power supply.
For the customers in the UK
If you use the monitor in the UK, be sure to use the supplied UK power cable.
• Before disconnecting the power cord, wait at least 30 seconds after turning off the power to allow the static electricity on the screen’s surface to discharge.
• After the power is turned on, the screen is demagnetized (degaussed) for about 5 seconds. This generates a strong magnetic field around the screen which may affect data stored on magnetic tapes and disks placed near the monitor. Be sure to keep magnetic recording equipment, tapes, and disks away from the monitor.
Installation
Do not install the monitor in the following places:
• on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies, etc.) that may block the ventilation holes
• near heat sources such as radiators or air ducts, or in a place subject to direct sunlight
• in a place subject to severe temperature changes
• in a place subject to mechanical vibration or shock
• on an unstable surface
• near equipment which generates magnetism, such as a transformer or high voltage power lines
• near or on an electrically charged metal surface
Maintenance
• Clean the screen with a soft cloth. If you use a glass cleaning liquid, do not use any type of cleaner containing an anti-static solution or similar additive as this may scratch the screen’s coating.
• Do not rub, touch, or tap the surface of the screen with sharp or abrasive items such as a ballpoint pen or screwdriver. This type of contact may result in a scratched picture tube.
• Clean the cabinet, panel and controls with a soft cloth lightly moistened with a mild detergent solution. Do not use any type of abrasive pad, scouring powder or solvent, such as alcohol or benzene.
Transportation
When you transport this monitor for repair or shipment, use the original carton and packing materials.
Use of the stand
Insert the supplied stand into the groove to adjust the angle of the monitor. You can use the stand in either the vertical or horizontal position.
Use of the groove on top (HMD-A200 only)
You can put a photo frame or CD case in the groove.
Note
Never use the slit for any other purpose.
Use of the headphones’ hook (HMD-A100 only)
Insert the supplied hook into one of the holes (ten on both the left and right sides) on either the left or right side of the monitor.
Note
Never hang heavy objects from the hook other than the headphones.
The equipment should be installed near an easily accessible outlet.
Example of plug types
for 100 to 120 V AC
for 200 to 240 V AC
for 240 V AC only
Side
5
GB
Identifying parts and controls
See the pages in parentheses for further details. (Model HMD­A200 is used for illustration purposes.)
1 Control button (page 9)
The control button is used to display the menu and make adjustments to the monitor, including brightness and contrast adjustments.
2 1 (power) switch and indicator (pages 6, 13, 16)
This button turns the monitor on and off. The power indicator lights up in green when the monitor is turned on, and either flashes in green and orange, or lights up in orange when the monitor is in power saving mode.
3 AC IN connector (page 6)
This connector provides AC power to the monitor.
4 Video input connector (HD15) (page 6)
This connector inputs RGB video signals (0.700 Vp-p, positive) and sync signals.
* DDC (Display Data Channel) is a standard of VESA.
5 USB (universal serial bus) downstream connectors
(page 7)
Use these connectors to link USB peripheral devices to the monitor.
6 USB (universal serial bus) upstream connector
(page 7)
Use this connector to link the monitor to a USB compliant computer.
MENU
AC IN
RearFront
Pin No. Signal
1 Red 2 Green
(Composite Sync on Green) 3 Blue 4 ID (Ground) 5 DDC Ground* 6 Red Ground 7 Green Ground 8 Blue Ground 9– 10 Ground 11 ID (Ground) 12 Bi-Directional Data (SDA)* 13 H. Sync 14 V. Sync 15 Data Clock (SCL)*
1 2
3 4
5
876
11 12 13 14
15
10
9
1-1
SECTION 1

GENERAL

6
Setup
Before using your monitor, check that the following accessories are included in your carton:
• Power cord (1)
• USB cable (1)
• Windows Monitor Information Disk (1)
• Monitor stand (1)
• Hook (1) (HMD-A100 only)
• Warranty card (1)
• Notes on cleaning the screen’s surface (1)
• This instruction manual (1)
Step 1:Connect your monitor to
your computer
Turn off the monitor and computer before connecting.
x Connecting to an IBM PC/AT or compatible
computer
x Connecting to a Macintosh or compatible
computer
Step 2:Connect the power cord
With the monitor and computer switched off, first connect the power cord to the monitor, then connect it to a power outlet.
Step 3:Turn on the monitor and
computer
First turn on the monitor, then turn on the computer.
The installation of your monitor is complete. If necessary, use the monitor’s controls to adjust the picture.
AC IN
to video output
IBM PC/AT or compatible computer
AC IN
You will need a Macintosh adapter (not supplied).
Macintosh or compatible computer
to video output
Macintosh adapter (not supplied)
AC IN
to AC IN
to a power outlet
power cord (supplied)
7
GB
If no picture appears on your screen
• Check that the monitor is correctly connected to the computer.
• If NO INPUT SIGNAL appears on the screen, confirm that your computer’s graphic board is completely seated in the correct bus slot.
• If you are replacing an old monitor with this model and OUT OF SCAN RANGE appears on the screen, reconnect the old monitor. Then adjust the computer’s graphic board so that the horizontal frequency is between 30 – 70 kHz, and the vertical frequency is between 48 – 120 Hz.
For more information about the on-screen messages, see “Trouble symptoms and remedies” on page 14.
For customers using Windows 95/98
To maximize the potential of your monitor, install the new model information file from the supplied Windows Monitor Information Disk onto your PC. This monitor complies with the “VESA DDC” Plug & Play standard. If your PC/graphics board complies with DDC, select “Plug & Play Monitor (VESA DDC)” or this monitor’s model name as the monitor type in the “Control Panel” of Windows 95/98. If your PC/graphics board has difficulty communicating with this monitor, load the Windows Monitor Information Disk and select this monitor’s model name as the monitor type.
For customers using Windows NT4.0
Monitor setup in Windows NT4.0 is different from Windows 95/98 and does not involve the selection of monitor type. Refer to the Windows NT4.0 instruction manual for further details on adjusting the resolution, refresh rate, and number of colors.
Adjusting the monitor’s resolution and color number
Adjust the monitor’s resolution and color number by referring to your computer’s instruction manual. The color number may vary according to your computer or video board. The color palette setting and the actual number of colors are as follows:
• High Color (16 bit) t 65,536 colors
• True Color (24 bit) t about 16.77 million colors
In true color mode (24 bit), speed may be slower.
Connecting Universal Serial Bus (USB) compliant peripherals
Your monitor has one upstream USB connector (on the rear panel) and four downstream USB connectors (two on both the left and right sides). They provide a fast and easy way to connect USB compliant peripheral devices (such as keyboards, mice, printers and scanners) to your computer using a standardized USB cable. To use your monitor as a hub for your peripheral devices, connect the USBs as illustrated below.
1
Turn on the monitor and computer.
2
Connect your computer to the square upstream connector using the supplied USB cable.
For customers using Windows
If a message appears on your screen, follow the on-screen instructions and select Generic USB Hub as the default setting.
3 Connect your USB compliant peripheral devices to
the rectangular downstream USB connectors.
Notes
• Not all computers and/or operating systems support USB configurations. Check your computer’s instruction manual to see if you can connect USB devices.
• In most cases, USB driver software needs to be installed on the host computer. Refer to the peripheral device’s instruction manual for further details.
• The monitor functions as a USB hub as long as the monitor is either “on” or in power saving mode.
• If you connect a keyboard or mouse to the USB connectors and then boot your computer for the first time, the peripheral devices may not function. First connect the keyboard and mouse directly to the computer and set up the USB compliant devices. Then connect them to this monitor.
• Do not lean on the monitor when plugging in the USB cables. The monitor may suddenly shift and cause injury.
AC IN
to USB compliant peripheral devices
to a USB compliant computer
to USB compliant peripheral devices
1-2
8
Selecting the on-screen menu language (LANGUAGE/INFORMATION)
English, French, German, Italian, Spanish, Russian, and Japanese versions of the on-screen menus are available. The default setting is English.
1
Press the center of the control button.
See page 9 for more information on using the control button.
2 Move the control button to highlight LANGUAGE/
INFORMATION and press the the center of the control button again.
3
Move the control button m/M to select (LANGUAGE), and press the center of the control button. Then move the control button m/M to select a language.
• ENGLISH
• FRANÇAIS: French
• DEUTSCH: German
• ITALIANO: Italian
• ESPAÑOL: Spanish
: Russian
: Japanese
To close the menu
Press the center of the control button once to return to the main MENU, and twice to return to normal viewing. If no buttons are pressed, the menu closes automatically after about 30 seconds.
To reset to English
See “Resetting the adjustments (RESET)” on page 12.
Customizing Your Monitor
You can make numerous adjustments to your monitor using the on-screen menu.
Navigating the menu
Press the center of the control button to display the main MENU on your screen. See page 9 for more information on using the control button.
Use the control button to select one of the following menus.
EX I T H- S I ZE / CENTER V-SIZE/CENTER PIN/PIN BALANCE KEY / KEY BALANCE ROTATION ZOOM COLOR
RESET
LA NGU AGE / I NFORMAT NOI DEGAUSS / CANCEL MO ERI
MENU
MENU
b
ENGL I SH FRANÇAI S DEUTSCH IT A L I ANO ESPAÑOL
SELECT EXI T
LANGUAGE / I NFORMATION
MENU
b
1 EXIT
Select EXIT to close the menu.
2 H-SIZE/CENTER (page 10)
Select the H-SIZE/CENTER menu to adjust the picture’s horizontal size and centering.
3 V-SIZE/CENTER (page 10)
Select the V-SIZE/CENTER menu to adjust the picture’s vertical size and centering.
4 PIN/PIN BALANCE (page 10)
Select the PIN/PIN BALANCE menu to adjust the curvature picture’s sides.
5 KEY/KEY BALANCE
(page 11)
Select the KEY/KEY BALANCE menu to adjust the angle of the picture’s sides.
EX I T H- S I ZE / CENTER V-SIZE/CENTER PIN/PIN BALANCE KEY / KEY BALANCE ROTATION ZOOM COLOR
RESET
LA NGU AGE / I NFORMAT NOI DEGAUSS / CANCEL MO ERI
MENU
MENU
H-SIZE
26
SELECT EXI T
H- S I ZE /CENTER
V-SIZE
26
SELECT EXI T
V-SIZE/CENTER
PIN
26
SELECT EXI T
PIN/PIN BALANCE
KEY
26
SELECT EXI T
KEY / KEY BA L ANCE
9
GB
x Displaying the current input signal
The horizontal and vertical frequencies of the current input signal are displayed in the BRIGHTNESS/CONTRAST menu. If the signal matches one of this monitor’s factory preset modes, the resolution is also displayed.
x Using the control button
1 Display the main MENU.
Press the center of the control button to display the main MENU on your screen.
2 Select the menu you want to adjust.
Highlight the desired menu by moving the control button up (M), down (m), and left (<) or right (,) to move sideways.
3 Adjust the menu.
Move the control button left (<) or right (,) to make the adjustment.
4 Close the menu.
Press the center of the control button once to return to the main MENU, and twice to return to normal viewing. If no buttons are pressed, the menu closes automatically after about 30 seconds.
x Resetting the adjustments
You can reset the adjustments using the RESET menu. See page 12 for more information on resetting the adjustments.
6 ROTATION (page 11)
Select the ROTATION menu to adjust the picture’s rotation.
7 ZOOM (page 11)
Select the ZOOM menu to enlarge or reduce the picture.
8 COLOR (page 11)
Select the COLOR menu to adjust the picture’s color temperature. You can use this to match the monitor’s colors to a printed picture’s colors.
9 LANGUAGE/INFORMATION
(page 8, 15)
Select the LANGUAGE/ INFORMATION menu to choose the on-screen menu’s language and display this monitor’s information box.
0 DEGAUSS/CANCEL MOIRE
(page 12)
Select the DEGAUSS/CANCEL MOIRE menu to degauss the screen and cancel the moire.
qa RESET (page 12)
Select the RESET menu to reset the adjustments.
ROTATION
26
EXI T
ROTATION
ZOOM
26
EXI T
ZOOM
KKK
R50 G50 B50
SELECT EXI T
COLOR
5000 6500 9300
USER
ENGL I SH FRANÇAI S DEUTSCH IT A L I ANO ESPAÑOL
SELECT EXI T
LANGUAGE / I NFORMATION
DEGAUSS
ON
SELECT EXI T
DEGAUSS/CANCEL MOI RE
RESET
MODE AL L
EXI T
RESET
26 26
68.7kHz/85.0Hz 1024X768
BRI GHTNESS/ CONTRAST
the resolution of the current input signal
the horizontal and vertical frequencies of the current input signal
MENU
MENU
MENU
b
MENU
MENU
1-3
10
Adjusting the brightness and contrast (BRIGHTNESS/CONTRAST)
Brightness and contrast adjustments are made using a separate BRIGHTNESS/CONTRAST menu. These settings are stored in memory for all input signals.
1 Move the control button in any direction.
The BRIGHTNESS/CONTRAST menu appears on the screen.
2 Move the control button m/M to adjust the
brightness ( ), and </, to adjust the contrast (6).
The menu automatically disappears after about 3 seconds.
Adjusting the horizontal size or centering of the picture (H-SIZE/CENTER)
These settings are stored in memory for the current input signal.
1 Press the center of the control button.
The main MENU appears on the screen.
2 Move the control button to highlight H-SIZE/
CENTER, and press the center of the control button again.
The H-SIZE/CENTER menu appears on the screen.
3 First move the control button m/M to select the
desired adjustment item. Then move the control button </, to make the adjustment.
Adjusting the vertical size or centering of the picture (V-SIZE/CENTER)
These settings are stored in memory for the current input signal.
1 Press the center of the control button.
The main MENU appears on the screen.
2 Move the control button to highlight V-SIZE/
CENTER, and press the center of the control button again.
The V-SIZE/CENTER menu appears on the screen.
3 First move the control button m/M to select the
desired adjustment item. Then move the control button </, to make the adjustment.
Adjusting the curvature of the picture’s sides (PIN/PIN BALANCE)
These settings are stored in memory for the current input signal.
1 Press the center of the control button.
The main MENU appears on the screen.
2 Move the control button to highlight PIN/PIN
BALANCE, and press the center of the control button again.
The PIN/PIN BALANCE menu appears on the screen.
3 First move the control button m/M to select the
desired adjustment item. Then move the control button </, to make the adjustment.
Select To
H-SIZE
adjust the horizontal size
H-CENTER
adjust the horizontal centering
26 26
68.7kHz/85.0Hz 1024X768
BRI GHTNESS/ CONTRAST
Select To
V-SIZE
adjust the vertical size
V-CENTER
adjust the vertical centering
Select To
PIN
expand or contract the picture sides
PIN BALANCE
shift the picture sides to the left or right
11
GB
Adjusting the angle of the picture’s sides (KEY/KEY BALANCE)
These settings are stored in memory for the current input signal.
1 Press the center of the control button.
The main MENU appears on the screen.
2 Move the control button to highlight KEY/KEY
BALANCE, and press the center of the control button again.
The KEY/KEY BALANCE menu appears on the screen.
3 First move the control button m/M to select the
desired adjustment item. Then move the control button </, to make the adjustment.
Adjusting the picture’s rotation (ROTATION)
This setting is stored in memory for all input signals.
1
Press the center of the control button.
The main MENU appears on the screen.
2
Move the control button to highlight ROTATION, and press the center of the control button again.
The ROTATION menu appears on the screen.
3
Move the control button </, to rotate the picture.
Enlarging or reducing the picture (ZOOM)
This setting is stored in memory for the current input signal.
1
Press the center of the control button.
The main MENU appears on the screen.
2
Move the control button to highlight ZOOM and press the center of the control button again.
The ZOOM menu appears on the screen.
3
Move the control button </, to enlarge or reduce the picture.
Note
Adjustment stops when either the horizontal or vertical size reaches its maximum or minimum value.
Adjusting the color of the picture (COLOR)
The COLOR settings allow you to adjust the picture’s color temperature by changing the color level of the white color field. Colors appear reddish if the temperature is low, and bluish if the temperature is high. This adjustment is useful for matching the monitor’s colors to a printed picture’s colors. This setting is stored in memory for all input signals.
1
Press the center of the control button.
The main MENU appears on the screen.
2
Move the control button to highlight COLOR and press the center of the control button again.
The COLOR menu appears on the screen.
3
Move the control button </, to select a color temperature.
The preset color temperatures are 5000K, 6500K, and 9300K. Since the default setting is 9300K, the whites will change from a bluish hue to a reddish hue as the temperature is lowered to 6500K and 5000K.
4
If necessary, fine tune the color temperature.
First move the control button </, to select USER. Then move the control button m/M button to select R (red), G (green), or B (blue) and move the control button </, to make the adjustment.
If you fine tune the color temperature, the new color settings are stored in memory and recalled whenever you select USER.
Select To
KEY
adjust the picture width at the top of the screen
KEY BALANCE
shift the picture to the left or right at the top of the screen
KKK R50 G50
B50 SELECT EXI T
COLOR
5000 6500 9300
USER
1-4
12
Additional settings (DEGAUSS/CANCEL MOIRE)
You can manually degauss (demagnetize) the screen, and cancel the moire.
1
Press the center of the control button.
The main MENU appears on the screen.
2
Move the control button m/M to highlight DEGAUSS/CANCEL MOIRE and press the center of the control button again.
The DEGAUSS/CANCEL MOIRE menu appears on the screen.
3
Move the control button m/M to select the desired adjustment item.
Adjust the selected item according to the following instructions.
Degaussing the screen
The monitor is automatically demagnetized when the power is turned on.
To manually degauss the monitor, first move the control button m/M to select (DEGAUSS). Then move the control button ,.
The screen is degaussed for about 5 seconds. If a second degauss cycle is needed, allow a minimum interval of 20 minutes for the best result.
Cancelling the moire*
If elliptical or wavy patterns appear on the screen, adjust the moire cancellation level.
To adjust the amount of moire cancellation, first move the control button m/M to select (CANCEL MOIRE). Then move the control button </, until the moire effect is at a minimum.
* Moire is a type of natural interference which produces soft, wavy lines
on your screen. It may appear due to interference between the pattern of the picture on the screen and the phosphor pitch pattern of the monitor.
Resetting the adjustments (RESET)
This monitor has the following two reset methods. Use the RESET menu to reset the adjustments.
1 Press the center of the control button.
The main MENU appears on the screen.
2 Move the control button m/M to highlight 0 RESET
and press the center fo the control button again.
The RESET menu appears on the screen. Reset the settings according to the following instructions.
Resetting all of the adjustment data for the current input signal (MODE)
Move the control button <.
The MODE item is selected. All of the adjustment data for the current input signal is reset. Note that the following items are not reset by this method.
• on-screen menu language (page 8)
• picture’s rotation (page 11)
Resetting all of the adjustment data to factory preset levels (ALL)
Move the control button ,.
The ALL item is selected. All of the adjustment data for the current input signal is reset. All of the adjustment data (except for the USER settings in the COLOR menu) is reset to the factory preset levels.
Note
The monitor
s buttons will not operate for about 5 seconds when ALL is
selected.
MENU
Example of moire
13
GB
Technical Features
Preset and user modes
When the monitor receives an input signal, it automatically matches the signal to one of the factory preset modes stored in the monitor’s memory to provide a high quality picture at the center of the screen. (See Appendix for a list of the factory preset modes.) For input signals that do not match one of the factory preset modes, the digital Multiscan technology of this monitor ensures that a clear picture appears on the screen for any timing in the monitor’s frequency range (horizontal: 30 – 70 kHz, vertical: 48 – 120 Hz) . If the picture is adjusted, the adjustment data is stored as a user mode and automatically recalled whenever the same input signal is received.
Note for Windows users
For Windows users, check your video board manual or the utility program which comes with your graphic board and select the highest available refresh rate to maximize monitor performance.
Power saving function
This monitor meets the power-saving guidelines set by VESA,
ENERGY STAR, and NUTEK. If the monitor is connected to a
computer or video graphics board that is DPMS (Display Power Management Signaling) compliant, the monitor will automatically reduce power consumption in three stages as shown below.
* Figures reflect power consumption when no USB compatible
peripherals are connected to the monitor.
**When your computer enters the “active off” mode, the input signal is
cut and NO INPUT SIGNAL appears on the screen. After 20 seconds, the monitor enters the power saving mode.
Troubleshooting
Before contacting technical support, refer to this section.
If thin lines appear on your screen (damper wires)
The lines you are experiencing on your screen are normal for the Trinitron monitor and are not a malfunction. These are shadows from the damper wires used to stabilize the aperture grille and are most noticeable when the screen’s background is light (usually white). The aperture grille is the essential element that makes a Trinitron picture tube unique by allowing more light to reach the screen, resulting in a brighter, more detailed picture.
On-screen messages
If there is something wrong with the input signal, one of the following messages appears on the screen. To solve the problem, see “Trouble symptoms and remedies” on page 14.
The input signal condition
OUT OF SCAN RANGE
indicates that the input signal is not supported by the monitor’s specifications.
NO INPUT SIGNAL
indicates that no signal is being input to the monitor.
Power mode Power
consumption
*
1 (power) indicator
normal operation
115 W (HMD-A200) 95 W (HMD-A100)
green
1 standby 15 W green and orange
alternate
2 suspend 15 W green and orange
alternate
3 active off** 5 W orange power off 0 W off
Damper wires
INFORMATION
OUT OF SCAN RANGE
Input signal condition
1-5
14
Trouble symptoms and remedies
If the problem is caused by the connected computer or other equipment, please refer to the connected equipment’s instruction manual. Use the self-diagnosis function (page 16) if the following recommendations do not resolve the problem.
Symptom Check these items No picture
If the 1 (power) indicator is not lit • Check that the power cord is properly connected.
• Check that the 1 (power) switch is in the “on” position.
If the NO INPUT SIGNAL message appears on the screen, or if the 1 (power) indicator is either orange or alternating between green and orange
• Check that the video signal cable is properly connected and all plugs are firmly seated in their sockets (page 6).
• Check that the HD15 video input connector’s pins are not bent or pushed in.
xProblems caused by the connected computer or other equipment
• The computer is in power saving mode. Try pressing any key on the computer keyboard.
• Check that the computer’s power is “on.”
• Check that the graphic board is completely seated in the proper bus slot.
If the OUT OF SCAN RANGE message appears on the screen
xProblems caused by the connected computer or other equipment
• Check that the video frequency range is within that specified for the monitor. If you replaced an old monitor with this monitor, reconnect the old monitor and adjust the frequency range to the following. Horizontal: 30 – 70 kHz Vertical: 48 – 120 Hz
If no message is displayed and the 1 (power) indicator is green or flashing orange
• Use the Self-diagnosis function (page 16).
If using Windows 95/98 • If you replaced an old monitor with this monitor, reconnect the old monitor and do the
following. Install the Windows Monitor Information Disk (page 7) and select this monitor (“HMD-A100” or “HMD-A200”) from among the Sony monitors in the Windows 95/98 monitor selection screen.
If using a Macintosh system • Check that the Macintosh adapter (not supplied) and the video signal cable are properly
connected (page 6).
Picture flickers, bounces, oscillates, or is scrambled
• Isolate and eliminate any potential sources of electric or magnetic fields such as other monitors, laser printers, electric fans, fluorescent lighting, or televisions.
• Move the monitor away from power lines or place a magnetic shield near the monitor.
• Try plugging the monitor into a different AC outlet, preferably on a different circuit.
• Try turning the monitor 90° to the left or right.
xProblems caused by the connected computer or other equipment
• Check your graphics board manual for the proper monitor setting.
• Confirm that the graphics mode (VESA, Macintosh 16" Color, etc.) and the frequency of the input signal are supported by this monitor (Appendix). Even if the frequency is within the proper range, some video boards may have a sync pulse that is too narrow for the monitor to sync correctly.
• Adjust the computer’s refresh rate (vertical frequency) to obtain the best possible picture.
Picture is fuzzy • Adjust the brightness and contrast (page 10).
• Degauss the monitor* (page 12).
• Decrease the moire cancellation effect (page 12).
Picture is ghosting • Eliminate the use of video cable extensions and/or video switch boxes.
• Check that all plugs are firmly seated in their sockets.
15
GB
* If a second degauss cycle is needed, allow a minimum interval of 20 minutes for the best result. A humming noise may be heard, but this is not a
malfunction.
Displaying this monitor’s name, serial number, and date of manufacture (INFORMATION)
1
Press the center of the control button.
The main MENU appears on the screen.
2 Move the control button to highlight LANGUAGE/
INFORMATION and press the center of the control button.
The LANGUAGE/INFORMATION menu appears on the screen.
3 Move the control button m/M to select
(INFORMATION) and press the center of the control button.
This monitor’s information box appears on the screen.
If the problem persists, call your authorized Sony dealer and give the following information.
• Model name: HMD-A100, HMD-A200
• Serial number
• Name and specifications of your computer and graphics board.
Picture is not centered or sized properly
• Adjust the size or centering (page 10). Note that some video modes do not fill the screen to the edges.
Edges of the image are curved • Adjust the shape of the picture (page 10). Wavy or elliptical pattern (moire)
is visible
• Cancel the moire (page 12).
xProblems caused by the connected computer or other equipment
• Change your desktop pattern.
Color is not uniform • Degauss the monitor* (page 12). If you place equipment that generates a magnetic field,
such as a speaker, near the monitor, or if you change the direction the monitor faces, color may lose uniformity.
White does not look white • Adjust the color temperature (page 11). USB peripherals do not function • Check that the appropriate USB connectors are securely connected (page 7).
• Check that the 1 (power) switch is in the “on” position.
xProblems caused by the connected computer or other equipment
• Check that the power of any self-powered USB compliant peripheral devices is “on.”
• Install the latest version of the device driver on your computer. Contact your device’s manufacturer for information about the appropriate device driver.
• If your USB compliant keyboard or mouse does not function, connect them directly to your computer, reboot your computer, and make any necessary adjustments to the USB settings. Then reconnect the keyboard or mouse to the monitor.
• For customers using Windows 95
1. Right-click on My Computer and select Properties.
2. Click on the Device Manager tab. Scroll down and select Universal Serial Bus
Controller. ,If Universal Serial Bus Controller does not appear, you need to load a USB
supplement disk. Contact your computer’s manufacturer for more information about obtaining a USB supplement disk.
3. Select Generic USB Device from the USB controller list and click on Properties.
4. If there is a check in the box next to “Disable in this hardware profile,” remove the
check.
5. Click on Refresh.
A hum is heard right after the power is turned on
• This is the sound of the auto-degauss cycle. When the power is turned on, the monitor is automatically degaussed for 5 seconds.
Symptom Check these items
MODE L : HMD - A 100 SERIAL :12345678 MANUFACTURED: 1 9 9 9 - 5 2
SELECT EXI T
LANGUAGE / I NFORMATION
Example
1-6
16
Self-diagnosis function
This monitor is equipped with a self-diagnosis function. If there is a problem with your monitor or computer, the screen will go blank and the 1 (power) indicator will either light up green or flash orange. If the 1 (power) indicator is lit in orange, the computer is in power saving mode. Try pressing any key on the keyboard.
If the 1 (power) indicator is green 1
Disconnect the video input cable, or turn off the connected computer.
2 Press the 1 (power) button to turn the monitor off
and on.
3 Move the control button , for 2 seconds before the
monitor enters power saving mode.
If all three color bars appear (red, green, blue), the monitor is working properly. Reconnect the video input cables and check the condition of your computer. If the color bars do not appear, there is a potential monitor failure. Inform your authorized Sony dealer of the monitor’s condition.
If the 1 (power) indicator is flashing orange
Press the 1 (power) button to turn the monitor off and on.
If the 1 (power) indicator lights up green, the monitor is working properly.
If the 1 (power) indicator is still flashing, there is a potential monitor failure. Count the number of seconds between orange flashes of the 1 (power) indicator and inform your authorized Sony dealer of the monitor’s condition. Be sure to note the model name and serial number of your monitor. Also note the make and model of your computer and video board.
MENU
1 (power) indicator
MENU
1-7
HMD-A200/A220
SECTION 2

DISASSEMBLY

2-1. BUCKET REMOVAL
2
Two claws
3
Bucket
1
Two screws (+BVTP 4 x 16)
2-3. H BOARD REMOVAL
5
Switch
4
Two screws (+BVTP 3 x 12)
P703
2
Screw (+BVTP 3 x 12)
P701
P702
3
H board
1
Two screws (+BVTP 3 x 12)
2-2. A, D, U1 AND U2 BOARDS REMOVAL
14
Two screws (+BVTP 3 x 12)
15
Screw (+BVTP 4 x 16)
CN906
12
Two screws (+BVTP 3 x 12)
CN006
13
U1 board
CN001
CN002
9
Two claws
1
Screw (+BVTP 4 x 16)
10
Two claws
CN003
CN004
1
U2 board
8
GND
GND
GND
6
Screw (+BVTP 3 x 12)
Five screws (+BVTP 3 x 12)
CN505
CN501
CN602
2
CN605
A board
CN506
GND
3
GND
7
Cable bracket
Screw (+BVTT 4 x 8)
4
Cable stopper
5
Two screws (+BVTP 3 x 12)
11
D board
2-1
CN603
2-4. PICTURE TUBE REMOVAL
11
Tension spring
10
Tension spring
CN605
HMD-A200/A220
3
Two screws (+BVTP 3 x 12)
7
Deflection yoke
9
Picture tube
8
Four screws (Tapping screw 5)
Anode cap
1
13
Two degaussing coil holders
2
A board
GND
GND
CN603
CN603
CN003
GND
6
Neck assy
12
CN506
CN004
GND
Two degaussing coil holders
Cushion
5
D board
4
Claw
CN505
CN906
CN501
CN001
CN602
CN002
• REMOVAL OF ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
• REMOVING PROCEDURES
after removing the anode.
c
b
a
1 Turn up one side of the rubber cap in
the direction indicated by the arrow a.
2 Using a thumb pull up the rubber cap
firmly in the direction indicated by the arrow b.
• HOW TO HANDLE AN ANODE-CAP
1
Don’t scratch the surface of anode-caps with shartp shaped mate­rial!
2 Don’t press the rubber hardly not to damege inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the rubber.
3 Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
Anode Button
3 When one side of the rubber cap is
separated from the anode button, the anode-cap can be removed by turning up the rubber cap and pulling up it in the direction of the arrow c.
2-2
Loading...