• Do not block any ventilation openings.
Install in accordance with the manufacturer’s instructions.
• Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding-type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
• Only use attachments/accessories specified by the
manufacturer.
• Use only with the cart, stand, tripod, bracket, or
table specified by the manufacturer, or sold with
the apparatus.
When a cart is used, use caution when moving
the cart/apparatus combination to avoid injury
from tip-over.
• Unplug this apparatus during lightning storms or when
unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
Afin d’éviter tout risque d’incendie ou
d’électrocution, ne pas exposer cet
appareil à la pluie ou à l’humidité.
Afin d’écarter tour risque d’électrocution,
garder le coffret fermé. Ne confier
l’entretien de l’appareil qu’à un personnel
qualifié.
CET APPAREIL DOIT ÊTRE RELIÉ À LA
TERRE.
WARNUNG
Um Feuergefahr und die Gefahr eines
elektrischen Schlages zu vermeiden, darf
das Gerät weder Regen noch Feuchtigkeit
ausgesetzt werden.
Um einen elektrishen Schlag zu
vermeiden, darf das Gehäuse nicht
geöffnet werden. Überlassen Sie
Wartungsarbeiten stets nur qualifiziertem
Fachpersonal.
DIESES GERÄT MUSS GEERDET
WERDEN.
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
To avoid electrical shock, do not open the
cabinet. Refer servicing to qualified
personnel only.
THIS APPARATUS MUST BE EARTHED.
This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to persons.
This symbol is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
WARNING: THIS WARNING IS APPLICABLE FOR USA
ONLY.
If used in USA, use the UL LISTED power
cord specified below.
DO NOT USE ANY OTHER POWER CORD.
Plug Cap Parallel Blade with ground pin
(NEMA 5-15P Configuration)
CordType SJT, three 16 or 18 AWG
wires
LengthMinimum 1.5 m, less than
2.5 m (8 ft 3 in)
RatingMinimum 10 A, 125 V
Using this unit at a voltage other than 120 V
may require the use of a different line cord or
attachment plug, or both. To reduce the risk
of fire or electric shock, refer servicing to
qualified service personnel.
WARNUNG: DIESE WARNUNG GILT FÜR ANDERE
LÄNDER.
1. Verwenden Sie Netzkabel (dreiadrig), Geräteanschlüsse
und Netzkabelstecker mit Masseleitung, die den
Sicherheitsrichtlinien des jeweiligen Landes entspricht.
2. Verwenden Sie Netzkabel (dreiadrig), Geräteanschlüsse
und Netzkabelstecker mit Masseleitung, die den vor Ort
herrschenden Spannungsanforderungen (Spannug,
Stromstärke) entsprechen.
Bei Frage über die Eignung und Sicherheit von Netzkabein
(dreiadrig), Geräteanschlüssen und Netzkabelsteckern
wenden Sie sich bitte an einen qualifizierten
Elektrotechniker.
CAUTION
The apparatus shall not be exposed to dripping or splashing
and no objects filled with liquid, such as vases, shall be
placed on the apparatus.
ATTENTION
Eviter d’exposer l’appareil à un égouttement ou à des
éclaboussures et ne placer aucun objet rempli de liquide,
comme un vase, sur l’appareil.
ACHTUNG
Das Gerät ist nicht tropf- und spritzwassersicher, daher
dürfen keine mit Flüssigkeiten gefüllten Gegenstände, z. B.
Vasen, darauf abgestellt werden.
WARNING: THIS WARNING IS APPLICABLE FOR
OTHER COUNTRIES.
1. Use the approved Power Cord (3-core mains lead)/
Appliance Connector/Plug with earthing-contacts that
conforms to the safety regulations of each country if
applicable.
2. Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings
(Voltage, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please consult a qualified
service personnel.
AVERTISSEMENT: CET AVERTISSEMENT EST
VALABLE POUR LES AUTRES PAYS.
1. Utiliser un cordon d’alimentation approuvé (conducteur
d’alimentation 3 âmes)/connecteur d’appareil/prise avec
contacts de mise à la terre conforme aux règles de
sécurité de chaque pays si applicable.
2. Utiliser un cordon d’alimentation approuvé (conducteur
d’alimentation 3 âmes)/connecteur d’appareil/prise
conforme aux valeurs nominales (tension, ampérage)
correctes.
CAUTION
The unit is not disconnected from the AC power source
(mains) as long as it is connected to the wall outlet, even if
the unit itself has been turned off.
ATTENTION
Cet appareil n’est pas déconnecté de la source
d’alimentation secteur tant qu’il est raccordé à la prise
murale, même si l’appareil lui-même a été mis hors tension.
ACHTUNG
Solange das Netzkabel an eine Netzsteckdose
angeschlossen ist, bleibt das Gerät auch im
ausgeschalteten Zustand mit dem Strommetz verbunden.
S’adresser à un personnel de service qualifié pour toute
question concernant l’emploi du cordon d’alimentation/
connecteur d’appareil/prise ci-dessus.
For the customers in U.S.A.
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a
residential area is likely to cause harmful interference in
which case the user will be required to correct the
interference at his own expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with
the limits for a digital device pursuant to Subpart B of Part
15 of FCC Rules.
For the customers in the U.S.A
This product contains mercury. Disposal of this product may
be regulated if sold in the U.S.A. For disposal or recycling
information, please contact your local authorities or the
Electronics Industries Alliance
(www.eiae.org http://www.eiae.org ).
Do not install the appliance in a confined space, such as
book case or built-in cabinet.
For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors), E4 (controlled EMC environment, ex. TV
studio).
Pour les clients européens
Ce produit portant la marque CE est conforme à la fois à la
Directive sur la compatibilité électromagnétique (EMC) (89/
336/CEE) et à la Directive sur les basses tensions (73/23/
CEE) émises par la Commission de la Communauté
européenne.
La conformité à ces directives implique la conformité aux
normes européennes suivantes:
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans les
environnements électromagnétiques suivants:
E1 (résidentiel), E2 (commercial et industrie légère), E3
(urbain extérieur) et E4 (environnement EMC contrôlé ex.
studio de télévision).
Des programmes de télévision, films, bandes vidéo et
autres peuvent être protégés par des droits d’auteur.
L’enregistrement non autorisé de tels matériaux risque de
constituer une violation de ces droits d’auteur.
Das Gerät nicht an Orten aufstellen, z.B. in Bücherregalen
oder Einbauschränken, wo keine ausreichende Belüftung
gewährleistet ist.
Für Kunden in Europa
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die
EMV-Richtlinie (89/336/EWG) sowie die
Niederspannungsrichtlinie (73/23/EWG) der EGKommission.
Angewandte Normen:
für die folgenden elektromagnetischen Umgebungen: E1
(Wohnbereich), E2 (kommerzieller und in beschränktem
Maße industrieller Bereich), E3 (Stadtbereich im Freien) und
E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio).
Table of Contents
Chapter 1
Overview
Chapter 2
Locations and Functions
of Parts
Chapter 3
Setting Up the VTR
1-1 Features ........................................................................................... 1-1
1-1-1 Features of the SRW-5000/SRW-5500 ................................ 1-1
1-1-2 Features of the Control Panel ............................................... 1-3
Menu List ............................................................................................ A-13
Items Relating to VTR Operations (Nos. 001 to ...) ...................... A-14
Items Relating to Operation Panels (Nos. 101 to ...) ..................... A-19
Items Relating to Remote Interface (Nos. 201 to ...)..................... A-23
Items Relating to Editing (Nos. 301 to ...) .................................... A-24
Items Relating to Prerolling (Nos. 401 to ...) ................................ A-26
Items Relating to Recording Protection (Nos. 501 to ...) .............. A-27
Items Relating to the Time Code (Nos. 601 to ...) ........................ A-28
Items Relating to the Video Control (Nos. 706 to ...) ................... A-34
Items Relating to the Audio Control (Nos. 807 to ...) ................... A-37
Items Relating to Digital Processing (Nos. 902 to ...) ................... A-44
Items Relating to the Pulldown Control (Nos. A01 to ...) ............. A-49
Other Items (Nos. T01 to ...) ......................................................... A-51
Index ........................................................................................................ I-1
6Table of Contents
1-1 Features
Chapter 1 Overview
Chapter 1Overview
1-1-1 Features of the SRW-5000/
SRW-5500
The SRW-5000/
video cassette recorder using the HDCAM-SR format.
It is a small and light unit incorporating LSIs for signal
processing and is comparable to the HDCAM
HDW-F500 in size, weight and functionality.
The SRW-5500 only is a recorder supporting both the
HDCAM-SR and HDCAM formats.
HDCAM-SR Format
The HDCAM-SR format exploits technological
advances in signal processing and magnetic recording,
to provide functionality comparable to that of the
HDCAM format, while offering HD digital recording
and playback with high image and sound quality.
The technology incorporated in this unit includes the
following.
•Highly efficient and mild data compression using
newly developed MPEG-4 Studio Profile.
• Powerful error-correcting codes
•High-performance, high-accuracy heads and drum
with dynamic tracking (DT ™), together with a new
auto-tracking technique, yielding highly reliable
narrow track recording and playback.
These technologies allow 120 minutes of recording on
an HDCAM-SR cassette (L type), the same size as the
HDCAM cassette.
Digital Signal Processing
In this unit, 4:2:2 component video signals obtained by
quantization according to ITU-R709, SMPTE 274M
and BTA S-002B (SMPTE 260M) are compressed
using MPEG-4 Studio Profile. Audio signals are
processed uncompressed, according to the AES/EBU
format.
Input interface
The input interface is based on the HDSDI (HD Serial
Digital Interface) format BTA S-004B/005B/006B
(SMPTE 291M/292M/299M) and ARIB STD B-4,
allowing a single BNC coaxial cable to carry one
component video signal, twelve digital audio channels,
and time code in time division multiplex; this is
SRW-5500
is a high-definition digital
1)
model
separated for conversion to parallel data.
Audio recording can be switched between the digital
audio signal multiplexed with the HD SDI signal and
the audio signal from an AES/EBU digital interface.
Bit rate reduction encoder
The component video signal undergoes frame
shuffling. It is then compressed by a process in which
it is subjected to DCT (discrete cosine transform) or
DPCM (differential pulse code modulation),
quantization control, and variable length word
encoding. This is the core of the newly developed
MPEG-4 Studio Profile. Interlaced signals are
compressed in fields and progressive signals are
compressed in frames.
ECC encoder
The outer ECC (Error Correction Code) is added to the
compressed video and audio data, followed by the
inner ECC, ID data, and sync data. Reed-Solomon
codes are employed in this error correction system.
Channel coding
Video and audio data with the ECC added is recorded
in the form of serial data. The HDCAM-SR format
adopts a scrambled i-NRZ channel coding system,
giving consideration to off-track and noise
characteristics.
Playback signal processing
The playback digital signal is equalized by an
equalizer circuit. It then passes powerful inner and
outer ECCs which can correct dropouts in the
reproduced signal. It further goes through an error
concealment circuit to have errors still remaining in
the signal rectified.
Output interface
Component video data is converted into serial data and
multiplexed with audio data and time code, then output
in the HD SDI format.
With an HD-SD converter board installed, the unit can
output both D1 SDI and analog composite signals.
Besides audio data is output as digital data multiplexed
with the HD SDI signal, it is also output via an AES/
EBU digital interface. Analog data converted from
digital data is also provided.
The HDCAM format uses tape with the same 12.65
mm width as the Betacam series to enable recording of
up to two hours of high-quality HD video. Video
signal compression uses prefilter and coefficient
recording technology.
Advanced Recording and Playback
Functions
High-quality digital recording
This unit uses a component system to record video
signals. An AES/EBU format with a wide dynamic
range is used for 12-channel audio recording. A unique
and powerful error correction circuit and concealment
circuit are used in digital signal processing.
Accurate and stable video signal output is made
possible by setting and adjusting the internal digital
video processor.
Record/playback modes
HDCAM-SR format (SRW-5000/5500) or HDCAM
format (SRW-5500)
As the record/playback mode, you can select from the
following nine modes.
1080×1920: 59.94i/60i/50i/23.98PsF/24PsF/25PsF/
29.97PsF/30PsF
720×1280: 59.94P (HDCAM-SR format only)
Playback compatibility
You can select the following compatibility playback
functions.
However, Digital Betacam playback requires the
HKSR-5002 (option).
possible, and with the additional installation of an
HKSR-5003, conversion from a 4:4:4 signal to a 4:2:2
signal.
Noiseless playback with DT heads
When using the HDCAM-SR or HDCAM format, the
dedicated playback DT heads allow you to perform
noiseless playback in the range from –1 to +2 times
normal speed, including still-picture playback. When
using the Digital Betacam format, the playback range
is from –1 to +3. However, Digital Betacam playback
requires the HKSR-5002 (option).
Video and audio confidence heads
Video and audio (channels 1 through 12, or 4 channels
for the HDCAM format (SRW-5500 only)) signals can
be recorded and simultaneously played back to check
the recording.
Internal time code generator and reader
The internal time code generator allows you to record
time code (LTC or user bits) together with video and
audio signals. Time codes (LTC or user bits) can be
read during playback using the time code reader.
Computer servo system
Computer-controlled servo motors provide direct drive
for the drum, capstan, and two reels, enabling quick
and accurate tape access.
Capstan override function
You can adjust the playback speed by ±15% to ensure
synchronization between, for example, two VTRs
playing back the same program.
Independent audio level control
It is possible to adjust the recording and playback
levels either independently on each channel or
simultaneously on all 12 channels (or 4 channels for
HDCAM format (SRW-5500 only)) while monitoring
the peak values.
1)
Internal format conversion function
By installing an optional HKSR-5001, when the
operating mode of this unit is 23.98PsF or 24PsF, a
59.94i or 60i mode HD SDI output (audio/VITC
multiplex) is made available. Additionally, conversion
in either direction between 1080×1920 and 720×1280,
and conversion from 4:2:2 signal to 4:4:4 signal is
A contact-free system for writing, reading, and modifying
Tele-File
This unit incorporates the Tele-File memory label
system to allow users to read, write and update
videocassette management information, log data (IN/
OUT points) and cue point data on memory labels,
providing greater efficiency in cassette management
and editing.
video cassette-related information on IC memory-bearing
labels. Tele-File is a trademark of Sony Corporation.
memory label system
1-2Chapter 1 Overview
Chapter 1 Overview
Features for Ease of Operation
Compact, lightweight, low power consumption
The VTR is small and light enough to be used in
outside broadcast vans or in EFP (Electronic Field
Production) assignments.
Remote control operation
The VTR has a serial RS-422A 9-pin connector to allow
control of the VTR by an external control unit.
The VTR also comes with 9-pin REMOTE 1-IN(9P)
and REMOTE 1-I/O (9P) connectors to support bridge
connection of multiple SRW-5000/5500 units or other
VTRs equipped with 9-pin remote connectors for
simultaneous operation. Furthermore, you can control
the VTR from an external control unit with a parallel
(50-pin) interface.
Digital hours meter
The meter can show the total elapsed time since the
VTR was turned on, total drum revolution time, total
tape running time and total number of threadings and
unthreadings.
Menu-driven operations for a variety of
purposes
Eight menus are displayed on the 130 × 95 mm (5 1/8
inches × 3 3/4 inches) color display and are set using
the 10 function buttons.
You can register desired items to the menus other than
the SET UP menu.
Pressing the [F4] (PF ASSIGN) button in the SET UP
menu displays the menu items that can be registered.
HOME menu
Use this menu to make the basic settings for recording,
playback, and editing operations, and to select
channels to be edited during insert editing.
TC menu
Use this menu to make time code settings.
VIDEO menu
Use this menu to adjust the video signals. The VIDEO
menu screen shows the VTR operating mode, current
position time code, time code type, and so on.
Self-diagnosis
This function allows the VTR to perform self
diagnostics when a malfunction occurs. An error
message is displayed and a history of all errors that
have occurred is recorded.
Easy-to-maintain plug-in boards
The VTR uses plug-in circuit boards to simplify
servicing and inspection.
Mountable in standard 19-inch rack
The unit can be mounted in an EIA-standard 19-inch
rack.
For rack mounting, refer to the Installation Manual.
1-1-2 Features of the Control
Panel
The control panel provides eight menu screens
corresponding to different operation modes to allow
fast and easy adjustment of necessary settings, as well
as the ability to store menu settings to a memory stick
for later recall.
AUDIO menu
Use this menu to adjust the audio signals. The AUDIO
menu screen shows the VTR operating mode, current
position time code, time code type, and so on.
CUE menu
Use this menu to set up to 100 cue points. In page
mode, 10 cue points per page can be set on a total of
10 pages. In the TELE FILE menu, you can change
the setting for the memory label system Tele-File.
PF1/PF2 (Personal Function) menus
Use these menus to register up to 40 of the most
frequently used items from the other menus (up to ten
items each can be registered to PF1, ALT/PF1, PF2
and ALT/PF2).
SET UP menu
This menu enables the following settings.
• The VTR BANK menu allows up to eight pages of
menu settings to be saved.
•Use the MEMORY CARD menu to store current
settings of the VTR and up to eight pages of the
contents of the VTR memory bank to a memory stick.
•Use the scrollable PF ASSIGN menu to display the
items that can be registered, and to select and register
the most frequently used menu items.
Chapter 1 Overview1-3
Chapter 1 Overview
1-1 Features
•Use the scrollable VTR SETUP menu to display the
items necessary for making initial settings, and to
directly change settings without registering them with
the function buttons for each menu.
•Use the PANEL SETUP menu to set control panel
operations, such as the keyboard sound output.
MAINTENANCE menu
Use this menu to access the maintenance functions.
For details, refer to the Maintenance Manual Volume 1.
A full complement of storage/recall
functions
These functions allow you to use titles to store and
recall menu settings in either the VTR’s internal
memory banks or memory sticks.
VTR memory banks
These memory banks allow you to store up to eight
pages of VTR settings in addition to the current VTR
settings. Factory settings are also stored here,
allowing the VTR to be reset to these values at any
time.
Memory sticks
Each memory stick can hold the current VTR settings
as well as up to eight pages of settings. A single
memory stick thus allows you to store and recall the
entire contents of the VTR memory banks.
A full range of editing functions
Two SRW-5000/5500 units can be connected allowing
automatic or manual assembly and insertion. The
VTR also features a full range of editing functions,
including preview, review, preroll, and the setting or
changing of edit points.
Quick access to edit points
The following methods are provided for the setting of
edit points:
•Multi-cuing for up to 100 edit points
• Search dial with shuttle and jog functions
•Direct input through numeric buttons
DMC (Dynamic Motion Control) editing
Using the DT
play back a section of an edit at speeds between –1 and
+2 times normal speed and store the speed variation in
memory for later use in automatic editing.
Split editing
In insert mode, audio and video edit points can be set
separately.
Preread editing
Video and audio signals that have been pre-read can be
externally processed and simultaneously re-recorded.
A variety of audio editing modes
You can select cut-in editing, cross-fade editing, and
fade in/out editing for the audio signals.
®
(Dynamic Tracking) heads, you can
Title function
This function allows you to add titles when storing
data to the VTR memory bank or memory stick, thus
facilitating data retrieval and management.
Write protect function
Setting pages stored in VTR memory banks or
memory sticks can be write protected on an individual
basis.
Display of duration between edit points
The duration between any two of IN, OUT, AUDIO
IN, or AUDIO OUT points can be displayed by
simultaneously pressing two buttons corresponding to
those edit points.
Time code recorded on a video track during the vertical
blanking interval
1-4Chapter 1 Overview
1-2 Optional Accessories
Chapter 1 Overview
The following accessories can be used with this unit.
HKSR-5001 Format Converter Board
This allows format conversion described below:
• 2-3 pulldown (23.98PsF to 59.94i, 24PsF to 60i)
•Conversion between 1080 and 720P
• 4:2:2 between 4:4:4
(Conversion of 4:4:4 to 4:2:2 is possible only when
the HKSR-5003 is additionally installed.)
HKSR-5002 Digital Betacam Playback Board
This allows you to play back Digital Betacam tapes
and output SD and HD.
When the system is operated in 4:4:4 mode, up
conversion of the output to HD signals are possible as
follows, depending on the system setting.
1080: Up conversion to 1080.
720: Up conversion to 720P.
When the system is operated in 4:4:4 mode, no upconverted HD output can be obtained.
HKSR-5003 RGB Record Playback Board
This allows you to accept dual link HD SDI input, and
record and play back RGB (4:4:4).
Installation Manual (supplied)
Provides necessary information to install and operate
the VTR.
For information about changing the video system, refer to
“1-11. System Setting” in the Installation Manual.
9-pin Protcol Manual (optional)
Provides information on the 9-pin protocol.
HKDV-900 HD Digital Video Controller
This allows you to remotely control the parameters for
video signals and image enhancement.
References
In addition to this Operation Manual, the following
manuals are available:
Maintenance Manual Volume 1 (optional)
Provides detailed information necessary to maintain
the VTR.
Maintenance Manual Volume 2 (optional)
Provides information on spare parts.
Maintenance Manual Volume 3 (optional)
Contains circuit diagrams and block diagrams.
Chapter 1 Overview1-5
Chapter 1 Overview
1-1 Features
1-3 Using the CD-ROM Manual
The supplied CD-ROM includes operation manuals for
this unit (English, Japanese, French and German
versions).
1-3-1
CD-ROM System
Requirements
The following are required to access the supplied CDROM disc.
•Computer: PC with MMX Pentium 166 MHz or
faster CPU, or Macintosh computer with PowerPC
CPU.
- Installed memory: 32 MB or more
- CD-ROM drive: × 8 or faster
•Monitor: Monitor supporting resolution of 800 × 600
dots or higher
When these requirements are not met, access to the
CD-ROM disc may be slow, or not possible at all.
1-3-2
The following software must be installed on your
computer in order to use the operation manuals
contained in the CD-ROM disc.
•Microsoft Internet Explorer Version 4.0 or higher, or
Netscape Navigator Version 4.0 or higher
•Adobe Acrobat Reader Version 4.0 or higher
Preparations
1-3-3
To Read the CD-ROM
Manual
To read the operation manual contained in the CDROM disc, do the following.
1 Insert the CD-ROM disc in your CD-ROM drive.
A cover page appears automatically in your
browser.
If it does not appear automatically in the browser,
double click the index.htm file on the CD-ROM
disc.
2 Select and click the operation manual that you
want to read.
A PDF file of the operation manual opens.
Note
If you lose the CD-ROM disc or become unable to
read its content, for example because of a hardware
failure, contact a Sony service representative.
Notes
• If Microsoft Internet Explorer is not installed, it may
be downloaded from the following URL:
http://www.microsoft.com/ie
• If Netscape Navigator is not installed, it may be
downloaded from the following URL:
http://home.netscape.com/
• If Adobe Acrobat Reader is not installed, it may be
downloaded from the following URL:
http://www.adobe.com/products/acrobat/
readstep.html
• MMX and Pentium are registered trademarks of Intel
Corporation or its subsidiaries in the United States and
other countries.
• PowerPC is a registered trademark of International
Business Machines Corporation.
•Macintosh is a registered trademark of Apple Computer,
Inc.
•Microsoft is a registered trademark of Microsoft
Corporation in the United States and/or other countries.
• Netscape Navigator is a registered trademark of Netscape
Communications Corporation in the U.S. and other
countries.
• Adobe and Acrobat are registered trademarks of Adobe
Systems Incorporated in the United States and/or other
countries.
1-6Chapter 1 Overview
2-1 Control Panel
Chapter 2 Locations and Functions of Parts
The control panel consists of the following sections:
•Upper control panel
Upper control panel
1 Menu control section
• Lower control panel
• System set-up panel
HD DIGITAL VIDEO CASSETTE RECORDER
3 Tape transport control section
2 Editing control section
(see page 2-4)
Chapter 2Locations and Functions of Parts
4 Display section
(see page 2-8)
SRW-5000
5 Search control section
(see page 2-10)
(see page 2-7)
(see page 2-6)
Lower control panel
Note
System set-up panel: Access by opening the lower control panel
Normally operate the unit with the control panel
closed.
For details of how to open the control panel, for example for
system setup, refer to the Maintenance Manual.
(see page 2-11)
Chapter 2 Locations and Functions of Parts2-1
2-1 Control Panel
SRW-5000
HD DIGITAL VIDEO CASSETTE RECORDER
2-1-1 Upper Control Panel
Chapter 2 Locations and Functions of Parts
1 POWER switch
2 ERROR indicator
3 WARNING indicator
4 EJECT button
5 Format indicators
POWER
ERROR WARNING
PHONES
9 PHONES jack
CHANNEL
CONDITION
7 CHANNEL CONDITION indicators
8 PHONES level control
EJECT
REMOTE
ETHERNET
1(9P) 2(50P)
6 REMOTE buttons
1 POWER switch
Pressing on the ‘(’ side of this switch powers the unit
and lights up the information display (page 2-8) and
color display (page 2-5). To turn the unit off, press on
the ‘a’ side of the switch.
2 ERROR indicator
This lights when a serious problem occurs, such as an
operational malfunction or system internal error.
You can check the details on the lower control panel.
For details, see “Error Messages and Warning Messages”
on page A-5.
3 WARNING indicator
This flashes when there is a fault in the unit. You can
check the details on the lower control panel.
For details, see “Error Messages and Warning Messages”
on page A-5.
4 EJECT button
Pressing this button automatically ejects the cassette
after several seconds.
Cassette compartment
5 Format indicators (Digital BETACAM/
HDCAM/HDCAM SR)
These show the format of the cassette loaded into the
unit.
6 REMOTE buttons
Press one of the following buttons, to select how the
VTR is controlled.
ETHERNET: This button lights when pressed,
1(9P): This button lights when pressed, enabling this
2(50P): This button lights when pressed, enabling
Note
When the VTR is being controlled by the external
equipment connected to the REMOTE 1-IN (9P) or
REMOTE 2 PARALLEL I/O (50P) connector, all tape
transport buttons and edit operation buttons are
disabled, except the STOP and EJECT buttons. You
may also specify the disabling or enabling of all
buttons by setting the VTR SETUP menu item 008
“LOCAL FUNCTION ENABLE”.
enabling access from the network connected to the
ETHERNET connector on this unit.
unit to be controlled from a device connected to
the REMOTE 1-IN (9P) connector or REMOTE
1-I/O (9P) connector.
this unit to be controlled from a device connected
to the REMOTE 2 PARALLEL I/O (50P)
connector.
2-2Chapter 2 Locations and Functions of Parts
7 CHANNEL CONDITION indicators
These show the status of the playback signal.
Blue: The playback signal status is satisfactory.
Yellow: The playback signal is somewhat degraded,
but playback is possible.
However, if this indicator remains lit
continuously, head cleaning is required.
Red: The playback signal has deteriorated. However,
if this indicator remains lit continuously, head
cleaning or internal inspection is required.
8 PHONES level control
Adjusts the output level to the PHONES jack.
For details, see “5-1-2 Selecting Audio Signals” on page
5-2.
9 PHONES jack
Connect stereo headphones with 8 Ω impedance for
audio monitoring during recording, playback, and
editing. Adjust the headphone output level with the
PHONES level control.
Chapter 2 Locations and Functions of Parts
Chapter 2 Locations and Functions of Parts2-3
2-1 Control Panel
2-1-2 Lower Control Panel
Chapter 2 Locations and Functions of Parts
1 Menu Control Section
9 DISPLAY button
0 FULL/FINE button
qa PB LEVEL button
qs REC LEVEL button
DIAG
8 DIAG button
1 MONITOR R buttons
2 MONITOR L buttons
OVER
OVER
OVER
OVER
OVER
OVER
dB
dB
dB
dB
0
0
-10
-10
-20
-20
-30
-30
-40
-40
L R
L R
CH1
CH2
EDIT PRESETVIDEO TC
dB
0
0
-10
-10
-10
-20
-20
-20
-30
-30
-30
-40
-40
-40
L R
L R
CH3
CH4
OVER
dB
dB
0
0
0
-10
-10
-20
-20
-30
-30
-40
-40
L R
L R
L R
CH5
CH6
CH7
F1
F2
F3
F4
F5ALTF6F7F8F9 F10
6 Function buttons
7 ALT button
3 MULTI CONTROL knob
HOME
TC
VIDEO
AUDI O
CUE
PF1
PF2
SET UP
MULTI
CONTROL
L
MONITOR
CH12CH11CH10CH9CH8CH7CH6CH5CH4CH3CH2CH1
R
OVER
OVER
OVER
OVER
0
L R
CH10
OVER
dB
dB
0
0
-10
-10
-20
-20
-30
-30
-40
-40
L R
L R
CH11
CH12
dB
dB
dB
0
0
-10
-10
-10
-20
-20
-20
-30
-30
-30
-40
-40
-40
L R
L R
CH8
CH9
4 Menu selection buttons
5 Color display
1 MONITOR R buttons
Select the audio signal output from the MONITOR
OUTPUT R connector. This assigns the desired
channel to the MONITOR OUTPUT R connector. If
you assign more than one channel to the same monitor
output connector, a mixed audio signal is output.
You can also make this setting using the VTR SETUP
menu item 808 “AUDIO MONITOR-R select”.
In the audio playback level adjustment mode, this is
used to select the channel to be adjusted.
2-4Chapter 2 Locations and Functions of Parts
2 MONITOR L buttons
Select the audio signal output from the MONITOR
OUTPUT L connector. This assigns the desired
channel to the MONITOR OUTPUT L connector. If
you assign more than one channel to the same monitor
output connector, a mixed audio signal is output.
You can also make this setting using the VTR SETUP
menu item 807 “AUDIO MONITOR-L select”.
In the audio playback level adjustment mode, this is
used to select the channel to be adjusted.
3 MULTI CONTROL knob
Used to set the audio recording/playback level and
make settings in the SET UP menu (see page 4-67).
4 Menu selection buttons
These select the menu screen displayed on the display.
HOME button: Press this to go to the HOME menu
screen. The home menu provides settings for the
basic VTR operations and editing operations.
TC button: Press this to go to the TC (time code)
menu screen. In the time code menu, you can
switch LTC/VITC, switch DF/NDF, set the time
code to be displayed on an external monitor, and
so on.
VIDEO button: Press this to go to the VIDEO menu
screen. Use it to make video related settings.
AUDIO button: Press this to go to the AUDIO menu
screen. Use it to make audio related settings.
CUE button: Press this to go to the CUE menu
screen. The cue menu provides 10 pages to set cue
points. You can set up to 10 cue points per page.
You can also make settings for the Tele-File
memory label system.
PF1 button: Press this to go to the PF1 (personal
function 1) menu screen. You can register
frequently-used items in the PF1 menu. The
factory default setting is blank.
PF2 button: Press this to go to the PF2 (personal
function 2) menu screen. You can register
frequently-used items in the PF2 menu. The
factory default setting is blank.
SET UP button: Press this to go to the SET UP
menu screen. The setup menu provides functions
to save menu settings in VTR banks or save to a
memory stick, registration operations in the PF
buttons, VTR SETUP menu settings, and so on.
Menu display:
This displays the menu screen selected by the menu
selection buttons.
Each menu screen shows the functions assigned to the
function buttons ([F1] to [F10]), and shows
simultaneously information required for time code
display settings and so on.
6 Function buttons
Activates the functions in each menu.
7 ALT (alternative) button
Press to change the items displayed on the current
menu. Press again to return to the original items.
8 DIAG (diagnostic) button
Hold down the SFT button (see page 2-6) in the
editing control section and press this switch to switch
to the DIAG menu.
9 DISPLAY button
This displays the down-converted output signal in the
whole color display.
Notes
•Depending on the system settings, it may not be
possible to output some signals.
• This function is for a quick check of the output
signal, and cannot be used as a monitor.
Chapter 2 Locations and Functions of Parts
For details of menus, see “Chapter 4 Menu Settings” (page
4-1).
5 Color display
This comprises principally the audio level display and
menu display.
Audio Level display:
1)
In recording mode or E-E mode
, this displays the
audio recording levels.
In playback mode or CONFI mode, this displays the
playback levels.
The display mode can be changed with the FULL/
FINE button. The factory default display is a reference
level of –20 dB, and peak level 0 dB.
An abbreviation for Electric-to-Electric mode. In this
mode, video or audio input signals are passed and output
only through the VTR’s internal circuitry, and not
through the magnetic conversion system comprising tape
and heads.
Chapter 2 Locations and Functions of Parts2-5
2-1 Control Panel
0 FULL/FINE button
This selects the audio level meter display range.
Chapter 2 Locations and Functions of Parts
FULL: The audio level meter display is from –60 dB
to 0 dB, or –40 dB to +20 dB. Select which of
these ranges (peak level: 0 dB or +20 dB) is
displayed in the VTR SETUP menu item 814
“LEVEL METER SCALE”.
FINE: The audio level meter display range is
expanded, and displayed with a scale in steps of
0.25 dB. The reference marker LED at the center
of the level meter display range lights. When the
audio level exceeds the maximum display range,
the top OVER display flashes. When under the
minimum display range, the bottom line flashes.
qa PB (playback) LEVEL button
Press this button to enter the playback audio level
adjustment mode. In this mode, you can use the
MONITOR R button to select the adjustment target
channels from channels 1 to 12. While watching the
audio level meter, turn the MULTI CONTROL knob
for a desired audio level.
Clicking the MULTI CONTROL knob resets the
playback audio level to the factory set level (a
reference level of 0 dB is displayed for a +4 dBm
input). Clicking the MULTI CONTROL knob again
restores the adjusted level.
Press this button again to exit from the playback audio
level adjustment mode, and the MONITOR L and R
buttons return to the normal status (this status is called
the “MONITOR SELECT mode”).
qs REC (recording) LEVEL button
Press this button to enter the recording audio level
adjustment mode. In this mode, you can use the
MONITOR L button to select the adjustment target
channels from channels 1 to 12. While watching the
audio level meter, turn the MULTI CONTROL knob
for a desired audio level.
Clicking the MULTI CONTROL knob resets the
recording audio level to the factory set level (a
reference level of 0 dB is displayed for a +4 dBm
input). Clicking the MULTI CONTROL knob again
restores the adjusted level.
Press this button again to exit from the recording audio
level adjustment mode, and the MONITOR L and R
buttons return to the normal status (this status is called
the “MONITOR SELECT mode”).
2 Editing Control Section
1 Numeric buttons and +/– buttons
2 SFT button
3 RCL button
4 CLR button
5 SET button
6 INPUT CHECK
button
8
7
F
E
5
4
C
B
2
1
A
+
0
AUDI O
IN OUT
VIDEO
IN OUT
ENTRY
0 ENTRY button
qa IN/OUT buttons
qs AUDIO IN/OUT buttons
SFT
9
RCL
6
D
CLR
3
SET
–
9 Cursor buttons
AUTO
8 AUTO button
1 Numeric buttons and +/– buttons
Press to input time data or edit points data at the cursor
position in menu display. Press buttons 0 to 5 while
holding down the SFT button to input hexadecimal A
to F for user bits. Use the +/– buttons to increase or
decrease settings.
2 SFT (shift) button
Press buttons 0 to 5 while holding down this button to
input hexadecimal A to F for user bits.
Use also in combination with other buttons to perform
other operations.
3 RCL (recall) button
Press to recall the previous setting, etc.
4 CLR (clear) button
Press to clear input data.
INPUT
CHECK
PLAYER RECORDER
7 PLAYER/
RECORDER
buttons
2-6Chapter 2 Locations and Functions of Parts
5 SET button
Press to finalize input data.
6 INPUT CHECK button
While you hold down this button, the input signal is
output from the monitor output connector, so that you
can monitor the input video and audio.
When the LTC/VITC time code is shown on the
display, you can check the time code generator.
7 PLAYER/RECORDER buttons
Select which VTR is to be controlled by this VTR’s
control panel during editing when this VTR is used as
a recorder and an external VTR is connected to the
REMOTE 1-IN(9P) or REMOTE 1-I/O(9P) connector
as a player.
PLAYER: The tape transport buttons and editing
operation buttons on the control panel control the
external player VTR.
RECORDER: The tape transport buttons and
editing operation buttons on the control panel
control the recorder VTR (this VTR).
The PLAYER/RECORDER buttons have no effect
when using this VTR alone.
8 AUTO button
When this button is pressed, it lights up and auto edit
mode is activated.
3 Tape Transport Control Section
1 STANDBY button
2 PREROLL button
3 PREVIEW/REVIEW button
PREVIEW/
REVIEW
PREROLLSTANDBY
STOP
6 STOP button
1 STANDBY button
Press this button in other than standby mode to make it
light up and place the VTR in standby mode. The
head drum rotates in standby mode, thereby shortening
the time required for the tape to start.
Press this button while in standby mode to turn the
button off and exit from standby mode. The head
drum stops rotating and the tape tension is released. If
the VTR remains in standby mode for more than eight
minutes (factory setting), standby mode is
automatically canceled in order to safeguard the tape.
REC/EDIT
PLAY
4 REC/EDIT button
5 PLAY button
Chapter 2 Locations and Functions of Parts
9 Cursor buttons
Use to move the cursor (shown in reverse video) on
the display. Also use to change menu settings.
0 ENTRY button
Press to enter an edit or cue point.
While holding down this button, press either the
AUDIO IN or AUDIO OUT button, or the IN or OUT
button.
qa IN/OUT buttons
To set a IN or OUT point during editing, press either
of these buttons while holding down the ENTRY
button.
qs AUDIO IN/AUDIO OUT buttons
To set an AUDIO IN or AUDIO OUT point during
insert editing, press either of these buttons while
holding down the ENTRY button.
2 PREROLL button
Press to run the tape to the preroll point (a position
factory set to five seconds before the IN point).
Press this button while holding down the IN, OUT,
AUDIO IN or AUDIO OUT button to cue up the tape
at the corresponding edit point.
For details on changing the preroll time, see “4-2-6 Setting
the Preroll Time (PREROLL TIME)” on page 4-18.
3 PREVIEW/REVIEW button
After the edit points are set, press this button to
preview, on the monitor connected to the recorder, the
effect of the edit before it is performed. In this
operation, the tape runs, but no editing is carried out.
If you press this button after carrying out an edit, the
results of the edit are played back on the monitor
connected to the recorder.
Chapter 2 Locations and Functions of Parts2-7
2-1 Control Panel
4 REC/EDIT (recording/edit) button
Press this button while holding down the PLAY button
Chapter 2 Locations and Functions of Parts
to start recording.
If you press this button in play mode, manual editing
begins. After setting edit points, if you press this
button while the AUTO button is lit, automatic editing
is performed.
5 PLAY button
Press to start playback.
Press this button while holding down the REC/EDIT
button to start recording.
Pressing this button during recording or manual editing
changes the VTR to playback mode.
6 STOP button
Press this button to stop recording or playback.
When you insert the cassette, the VTR automatically
enters STBY OFF mode.
The STOP button flashes in the following cases.
• The [F2] (SERVO REF) button in the PF1 menu is set
to “input” but there is no video input signal.
• The [F2] (SERVO REF) button in the PF1 menu is set
to “ext” but there is no external reference video
signal.
• The input signal is out of synchronization with the
external reference video signal.
You can change the setting of the VTR SETUP menu
item 102 “REFERENCE SYSTEM ALARM” so that
the STOP button will not flash in these cases.
4 Display Section
SYS: 23.98PSF 1080 4:2:2 HDCAM-SR
: -------- ----- ----- --------PB
: 59.94i 1080 4:2:2 FC
5 REC INHIBIT indicator
1 Information display
The information display shows a number of different
pages. To change the page displayed, with no other
items selected in the menu display (HOME, TC,
1 Information display
T*R 02:01.01:28
REC
INHIBIT SERVO
PREREAD
3 PREREAD indicator
4 SERVO indicator
2 REF SYNC indicators
1
REF SYNC
EXTSDEXT
HD
INPUT
VIDEO
VIDEO, AUDIO, PF1, and PF2), turn the MULTI
CONTROL knob while holding it down.
The currently selected page number also appears at the
upper right of the information display.
Page 1: System status
SYS: Shows the recording system information (signal
standard and tape format).
PB: Shows the information recorded on the tape
(signal standard and tape format) while being
played back.
FC: Shows the converted signal standard when an
HKSR-5001 board is installed.
TC: Shows the LTC/VITC and DF/NDF settings, or
the time code sent to the external monitor.
Page 2: system status
ACTIVE LINE: Shows the status of 1080/1035
conversion active line.
1080t1080
1080t1035(CROP)
1080t1035(CONV)
1035t1035
1035t1080(PANEL)
1035t1080(CONV): Shows the current
conversion status.
- - - - -: Cannot be converted.
OFF: No conversion done.
DOWN CONV. OUTPUT: Shows the output status
of the down converter.
ACTIVE: Output.
MUTING: No output.
EOS: Appears at the location of the timecode for the
valid end of the previous recording.
Page 3: Phase (OUTPUT)
HD SDI OUTPUT ADV.: Shows the phase of the
main line HD SDI output.
OFF: In phase with reference.
–90H: 90H (HD) advanced with respect to
reference.
DOWN CONV. OUTPUT ADV.: Shows the phase
of the down converter output.
OFF: In phase with reference.
–2H: 2H (SD) advanced with respect to reference.
Page 4: Phase (AUDIO)
AUDIO PB OUTPUT ADV.: Shows the phase of
the audio output signal.
OFF: Output in phase with the video output signal.
–1Frame: Output one frame advanced with respect
to the video output signal.
2-8Chapter 2 Locations and Functions of Parts
AUDIO INPUT DELAY: Shows the recording
phase of the audio input signal.
OFF: Recorded in phase with the video output
signal.
+1Frame: Recorded one frame delayed with
respect to the video input signal.
AES/EBU & ANA OUTPUT: Shows the phase of
the AES/EBU and ANALOG AUDIO outputs.
REF: Output in phase with reference.
FC: In phase with the FC output.
–90H(HD): 90H (HD) advanced with respect to
reference.
–2H(SD): 2H (SD) advanced with respect to
reference.
Page 5: Phase (TC)
TC INPUT DELAY: Shows the recording phase of
the input timecode.
OFF: Recorded in phase with the input video
signal.
+1Frame: Recorded one frame delayed with
respect to the input video signal.
LTC OUTPUT: Shows the phase of the output LTC.
LINE: Output in phase with the main line HD SDI
output.
FC: Output in phase with the FC output.
Page 6: Meta Data
The display changes depending on the tape format in
use.
• HDCAM-SR
META DATA LINE(REC): Shows the three-line
setting for metadata recording on this unit.
META DATA LINE(OUT): Shows the three
lines in which the metadata is included.
• HDCAM
Displays L1/L2/DID/SDID. This combination is
counted as 1 packet. Up to 3 packets can be
recorded.
On the SRW-5500, the system settings related to
recording are shown on the left. If data is detected
in the input signal, the L1/L2 values in the first
line are highlighted. The right side shows
playback values detected on the tape.
Note
The ACTIVE LINE setting displayed on page 2 can be
made in the SYSTEM screen. The phase settings
displayed on pages 3 to 5 and the settings relating to
META DATA recording displayed on pege 6 can be
made in the PHASE SET/META DATA menu under
the ALT+OTHERS CHECK menu in the
MAINTENANCE menu.
For details, refer to the Installation Manual.
2 REF SYNC (reference signal) indicators
These indicate the signal selected as the reference
signal. If there is no reference signal input to the
selected connector, the STOP button flashes.
EXT SD: Lights when “extern SD” is selected by the
VTR SETUP menu item 006 “EXTERNAL
REFERENCE select”.
EXT HD: Lights when “extern HD” is selected by
the VTR SETUP menu item 006 “EXTERNAL
REFERENCE select”.
INPUT VIDEO: Lights when “INPUT” is selected
by the VTR SETUP menu item 005 “SERVO/AV
REFERENCE select”.
3 PREREAD indicator
Lights up during preread mode.
For more information about PREREAD, see “6-2-3 Preread
Editing” on page 6-15.
4 SERVO indicator
Lights up when the drum servo and capstan servo are
locked.
5 REC INHIBIT indicator
Only when this indicator is not lit, you can make
settings for assemble/insert editing mode, and carry
out recording and playback operations.
The status of this indicator depends on the setting of
the [F2] (REC INH) button in the HOME menu and the
state of the record-protect plug on the cassette.
Setting of the [F2]
(REC INH) button in
the HOME menu
allRecording disabledLit/flashing
crash REC, video/
CTL, audio/CTL
offRecording disabledLit/flashing
a) Toggling between lit/flashing settings is possible using
the VTR SETUP menu item 104 “REC INHIBIT LAMP
FLASHING”.
Chapter 2 Locations and Functions of Parts2-9
State of the recordprotect plug on the
cassette
Recording allowedLit
Recording disabledLit/flashing
Recording allowedUnlit
REC INHIBIT
indicator
UnlitRecording allowed
a)
a)
a)
a)
Chapter 2 Locations and Functions of Parts
2-1 Control Panel
5 Search Control Section
Chapter 2 Locations and Functions of Parts
1 SHUTTLE button
Press to enter shuttle mode. In this mode, the button
lights and playback at the speed corresponding to the
angle of rotation of the search dial is possible. The
playback speed range depends on the frame frequency
of the unit. In this mode, the search dial clicks at the
positions for 0 (still picture) and ±10 times normal
playback speed (HDCAM/Digital Betacam) or ±8
times normal playback speed (HDCAM-SR).
Frame frequencyPlayback speed
23.98/24 HzRanging from ±50
25 HzRanging from ±48
29.97/30 HzRanging from ±40
2 JOG button
Press to select jog mode. In this mode, the button
lights up and playback is possible at –1 to +1 times
normal speed, ±2 times normal speed (HDCAM/
HDCAM-SR), or ±3 times normal speed (Digital
Betacam) (determined by the setting in the VTR
SETUP menu item 107 “JOG DIAL RESPONSE”). In
this mode, the search dial does not click.
1 SHUTTLE button
2 JOG button
3 VAR button
V
G
O
J
E
L
T
T
U
H
S
F
E
S
R
E
V
E
R
O
4 Search dial
3 VAR (variable) button
Press to select variable speed playback mode for
noiseless playback in the range from –1 to +2 times
normal speed (HDCAM/HDCAM-SR) or –1 to +3
times normal speed (Digital Betacam). Playback
exceeding this speed range is not possible. The search
A
R
R
W
A
R
D
dial clicks at the positions for still-picture and normal
playback speed.
4 Search dial
Rotate to search for edit points. Rotate the dial
clockwise for forward playback (the B indicator lights
up) or counterclockwise for reverse playback (the b
indicator lights up). The x indicator lights up while
the VTR is in stop mode.
Shuttle mode: The playback speed corresponds to
the angle of rotation of the search dial. The
playback speed range depends on the frame
frequency of the unit. (See item 1SHUTTLEbutton.) The dial clicks at the positions for 0 (still
picture) and ±10 times normal playback speed
(HDCAM/Digital Betacam) or ±8 times normal
playback speed (HDCAM-SR).
Jog mode: The playback speed corresponds to the
rotational speed of the dial (–1 to +1 times normal
speed, ±2 times normal speed (HDCAM/
HDCAM-SR), or ±3 times normal speed (Digital
Betacam)) depending on the setting of the VTR
SETUP menu item 107 “JOG DIAL
RESPONSE”). The dial does not click.
Variable speed playback mode: Noiseless playback
is possible in the range from –1 to +2 times
normal speed (HDCAM/HDCAM-SR) or –1 to +3
times normal speed (Digital Betacam). The speed
settings can be changed using the menu. The dial
clicks at the positions for still-picture and normal
playback speed.
Capstan override mode: Rotating the dial while
holding down the PLAY button changes the
playback speed by up to ±15%.
2-10Chapter 2 Locations and Functions of Parts
2-1-3 System Set-Up Panel
Lift the lower control panel up to its horizontal
position to access the system set-up panel.
For details of opening and closing the control panel, refer
to the Maintenance Manual.
CONTROL PANEL connector
CONTROL PANEL
Card slot eject button
Memory stick eject button
Memory stick receptacle
PCM CIA card slot
Harness restraint
Chapter 2 Locations and Functions of Parts
For details, see “3-4 Using a Memory Stick” on page 3-9.
Chapter 2 Locations and Functions of Parts2-11
2-2 Connector Panel
2-2 Connector Panel
Chapter 2 Locations and Functions of Parts
1 ANALOG I/O section
(see page 2-13)
2 DIGITAL I/O section
3 Remote input/output section
(see page 2-16)
(see page 2-15)
4 Power supply
(see page 2-16)
2-12Chapter 2 Locations and Functions of Parts
1 ANALOG I/O (input/output) section
ANALOG I/O
REF INPUT
1
OFF ON
CH1
AUDIO OUTPUT
CH2CH3CH4
2 (OPTION)
OFF ON
75Ω75Ω
Chapter 2 Locations and Functions of Parts
1 MONITOR OUTPUT L/R connectors
2 AUDIO OUTPUT CH1 to CH4 connectors
3 REF. INPUT 1 connectors and 75 Ω termination switch
MONITOR OUTPUT
RLINOUT
CUE
600Ω
OFF ON
IN
OUT
TIME CODE
HD REF OUTSD OUT
SYNC
1
COMPOSITE
(MONITOR)
2
1 MONITOR OUTPUT L/R connectors (XLR-331, male)
These output the audio signals for monitoring L and R
channels. To select the signals to output, use the
MONITOR R and MONITOR L buttons on the lower
control panel.
For details, see “5-1-2 Selecting Audio Signals”on page
5-2.
2 AUDIO OUTPUT CH1 to CH4 connectors
(XLR-3-31, male)
These output up to four analog audio signal lines
(channels 1 to 4).
4 REF. INPUT 2 connectors and 75 Ω termination switch
5 SD OUT SYNC connector
6 SD OUT COMPOSITE connector
7 HD REF. OUT connectors
8 TIME CODE OUT connector
9 TIME CODE IN connector
0 CUE OUT connector
qa CUE IN connector (SRW-5500 only)
3 REF. INPUT 1 connectors (BNC) and 75 Ω
termination switch
Input a reference video signal of the selected field
frequency. Select HD or SD with the VTR SETUP
menu item 006 “EXTERNAL REFERENCE select”.
When HD is selected, input a tri-level SYNC signal.
When SD is selected, input a video signal with chroma
burst (VBS) or a monochrome video signal (VS).
A loop-through connection is possible. Set the 75 Ω
termination switch to OFF if you are using a loopthrough connection and set it to ON if you are not
using a loop-through connection.
Input a reference video signal of the field frequency
selected for the format converter output. Select HD or
SD with the VTR SETUP menu item A08 “FC
REFERENCE select”. When HD is selected, input a
tri-level SYNC signal for external synchronization.
When SD is selected, input a video signal with chroma
burst (VBS) or a monochrome video signal (VS). A
loop-through connection is possible. Set the 75 Ω
termination switch to OFF if you are using a loopthrough connection and set it to ON if you are not
using a loop-through connection.
5 SD OUT SYNC connector (BNC)
This outputs an NTSC or PAL signal for external
synchronization.
Note
The output phase is the same as that of the composite
signal output from the SD OUT COMPOSITE
connector.
Because the output phase changes with the operation
mode of the VTR, use this for synchronization with the
video monitor.
8 TIME CODE OUT connector (XLR 3-31, male)
Outputs the following time codes according to the
VTR operation mode.
In playback mode: Playback time code
In recording mode: Time code generated by the
internal time code generator, or time code input to
the TIME CODE IN connector.
To select the output signal, use the VTR SETUP menu
item 613 “TC OUTPUT SIGNAL IN REGENE
MODE.”
SettingDescription
off tapeIn playback mode, playback time code signal
regeneOnly when the servo is locked in playback
through
is output. In recording mode, TCG time code
signal is output.
mode, playback time code signal is
regenerated and output. In all other cases,
output is the same as for the "off tape"
setting.
The time code signal from the TIME CODE
IN connector is output as it is. (Used for
cascade connections.)
(For more information about cascade
connections, see “3-1-3 Cascade
Connection” on page 3-3.)
SD OUT COMPOSITE connector (BNC)
6
Outputs an analog composite signal for a video
monitor. When the ALT/[F6] (CHARA SUPER)
setting in the TC menu is on, character signals such as
time codes are superimposed on the output.
7 HD REF. OUT connectors (BNC)
Output an HD tri-level sync signal during tape
playback.
9 TIME CODE IN connector (XLR 3-32, female)
Accepts external time code for recording to tape.
Connect to the time code output connector of the
external equipment.
0 CUE OUT (cue output) connector (XLR-3-31,
male)
Outputs cue track audio during HDCAM or Digital
Betacam playback.
Note
There is no cue track on an HDCAM-SR tape, and
therefore no output.
1 HD SDI (SDI video/audio) INPUT A/B
connectors (BNC)
These accept SDI video/audio signals.
Note
The INPUT MONITOR connectors are for use with an
input monitor and does not follow the standards for
output.
2 FC OUT B (FORMAT CONV. OUTPUT B
(OPTION)) connectors (BNC)
These output two sets of format-converted video/audio
signals.
Note
These are only effective when the optional HKSR5001 format converter board is installed. When the
output format is selected as 4:4:4, LINK B is output,
and when the output format is selected as 4:2:2 it is not
output.
3 HD SDI (SDI video/audio) OUTPUT connectors
(BNC)
These output three sets of SDI video/audio signals.
2 FC OUT B connectors
3 HD SDI OUTPUT connectors
4 FORMAT CONV. OUT (OPTION) connectors
5 SD SDI OUT connectors
6 DIGITAL I/O (AES/EBU) OUTPUT connectors
7 DIGITAL I/O (AES/EBU) INPUT connectors
When the ALT/[F6] (CHARA SUPER) buttons are set
to ON in the TC menu, time data or other text data is
superimposed on the signal output from the
MONITOR A connector.
4 FORMAT CONV. OUT (OPTION) connectors
(BNC)
These output two sets of format-converted video/audio
signals.
When the ALT/[F5] (PD CHARA) buttons are set to
ON in the TC menu, the output has time data or other
text superimposed on the signal.
Note
This is only valid when the optional HKSR-5001
format converter board is installed. When the output
format is selected as 4:4:4, LINK A is output.
5 SD SDI (1/2/monitor) OUT connectors (BNC)
These output three sets of video/audio signals. When
the ALT/[F6] (CHARA SUPER) buttons are set to ON
in the TC menu, time data or other text data is
superimposed on the output from the MONITOR
OUTPUT L/R connector.
Chapter 2 Locations and Functions of Parts2-15
2-2 Connector Panel
6 DIGITAL I/O (AES/EBU) OUTPUT connectors
(BNC)
Chapter 2 Locations and Functions of Parts
These output digital signals in AES/EBU format for
channels 1 to 12.
7 DIGITAL I/O (AES/EBU) INPUT connectors
(BNC)
These accept digital signals in AES/EBU format for
channels 1 to 12.
3 Remote input/output section
1 RS232C connector
2 REMOTE1-IN connector
3 REMOTE 2 PARALLEL I/O connector
4 VIDEO CONTROL connector
5 REMOTE1-I/O connector
REMOTE 1-IN(9P)REMOTE 1-I/O(9P)
REMOTE 2 PARALLEL I/O(50P)
RS232C
VIDEO CONROL
Controller to enable remote control of the internal
digital video processor. Turn off the power before
connecting the remote controller.
Use this, with the supplied 9-pin remote control cable,
to connect the unit to another SRW-5000/5500 unit or
another HD VTR unit to carry out editing with a BVEseries editor BVE-900/910/2000/9000/9100.
6 USB connector
This is used for manufacturing and services.
7 ETHERNET connector
Used for monitoring the VTR by SNMP, or for setting
or changing VTR settings by HTTP.
Caution
For safety, do not connect the connector for peripheral
device wiring that might have excessive voltage to this
port.
Use this, with the supplied 9-pin remote control cable,
to connect the unit to another SRW-5000/5500 unit or
another HD VTR unit to carry out editing with a BVEseries editor BVE-900/910/2000/9000/9100.