Before starting adjustments
Adjusting items when replacing main parts and boards
List of service tools
CAMERA SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS
ADJUSTMENT PROGRAMS
CAMERA SYSTEM ADJUSTMENTS
LCD SYSTEM ADJUSTMENTS
SECTION 6
ADJUSTMENTS
SERVICE MODE
SERVICE MODE
Auto-ADJ
INITIALIZATION OF DATA
• Use this Service Manual together with the Automatic Adjustment Program (DSC-S600 Auto-Adj Ver1.[]r
Note:[] (numeric value) of the file name varies depending on the version of Automatic Adjustment Program.
• Precaution on Replacing the SY-145 board
[][]
.exe).
DSC-S600_ADJ
9-876-922-51
Sony EMCS Co.
2005L0500-1
© 2005.12
Published by DI Technical Support Department
Page 2

TABLE OF CONTENTS

Section Title Page
6. ADJUSTMENTS
Before Starting Adjustment ·······················································6-1 1-1. Adjusting Items When Replacing
Main Parts and Boards ····················································6-3 1-2. List of Service Tools ························································6-4 6-1. Camera Section Adjustments···········································6-5 1-1. Preparations Before Adjustments ····································6-5 1-2. Adjustment Programs ······················································6-9 1-3. Camera System Adjustments·········································6-10 1-4. LCD System Adjustments ·············································6-16 1-5. Error···············································································6-18 1-6. Initialization of Data······················································6-20 6-2. Service Mode·································································6-21
DSC-S600_ADJ
— 2 —
Page 3
SECTION 6

ADJUSTMENTS

Before starting adjustment

Precaution on Replacing the SY-145 board
•The Repair Board has already been adjusted. Re-initialization or EVR data copy from the set before repair is not required.
•Perform “Initial Language Data Check” mentioned below, and also the adjustment items necessary after SY Board replacement.
Initial Language Data Check
If the SY-145 board was replaced, initial language setting may be changed. Accordingly, change the following data so as to set same initial language as that of the set distributing in each region.
Initial language: Language displayed at the next starting if the setting of Setup menu was reset.
It is different from the language setting selectable with the menu.
Initial Language Data
Page Address Data Language GP2 GP3 GP4
00 English zzz 04 Spanish zz 06 Portugal z
4F 8C
Note: GP2 is fixed to English.
GP3 is either English, Spanish, or Russian. GP4 is either English, Spanish, Portugal, Simplified Chinese, or Korean.
08 Simplified Chinese z 0B Russian z 0D Korean z
Writing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Select page: 4F, address: 8C, and set the Initial Language Data.
3) Select page: 40, address: 38, and set data: 00.
4) Click [Save] on the SEUS screen.
5) Select page: 80, address: 34, and check that the data is “00”.
6) Select page: 80, address: 30, and check that the data is “00”.
7) Select page: 00, address: 01, and set data: 00.
8) Turn off the camera.
9) Turn on the camera. Execute “Initialize” of Setup screen.
10) Check the language displayed when the camera starts.
DSC-S600_ADJ
6-1
Page 4
Method for Copying or Erasing the Data in Internal Memory
The data can be copied/erased by the operations on the Setup screen. (When erasing the data, execute formatting the internal memory.)
Note 1: When replacing the SY-145 board, erase the data in internal memory of the board before replacement. Note 2: When replacing the SY-145 board or the IC203 on the SY-145 board, execute formatting and initialize the
internal memory after replacement.
Method for copying the data in internal memory
Copy
Copies all images in the internal memory to a “Memory Stick Duo”.
OK
Cancel
1 Insert a “Memory Stick Duo” having 32 MB or larger capacity. 2 Select [OK] with v on the control button, then press z.
The message “All data in internal memory will be copied Ready?” appears.
3 Select [OK] with v, then press z.
Copying starts.
See the following procedure . Cancels the copying.
•Use batteries with enough capacity or the AC Adaptor (not supplied). If you attempt to copy image files using batteries with little remaining capacity, the batteries may run out, causing copying to fail or possibly corrupting the data.
•You cannot copy individual images.
•The original images in the internal memory are retained even after copying. To delete the contents of the internal memory, remove the “Memory Stick Duo” after copying, then execute the [Format] command in
(Internal Memory Tool).
•You cannot select a folder copied on a “Memory Stick Duo”.
•Even if you copy data, a (Print order) mark is not copied.
Method for formatting the internal memory
This item does not appear when a “Memory Stick Duo” is inserted in the camera. The default settings are marked with .
Format
Formats the internal memory.
•Note that formatting irrevocably erases all data in the internal memory, including even protected images.
OK
Cancel
1 Select [OK] with v on the control button, th en press z.
The message “All data in internal memory will be erased Ready?” appears.
2 Select [OK] with v, then press z.
The format is complete.
See the following procedure . Cancels the formatting.
DSC-S600_ADJ
6-2
Page 5
1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table.
Note 1: The automatic Adjustment Program does not support the “Initialization of data”. Perform it manually. Note 2: When replacing the SY-145 board, erase the data in internal memory of the board before replacement. Note 3: When replacing the SY-145 board or the IC203 on the SY-145 board, execute formatting and initialize the internal memory
after replacement.
Note 4: When replacing the SY-145 board, perform “Initial Language Data Check” after replacement.
Replaced parts
Block Mounted parts Board
replacement replacement replacement
Adjusting item Adjustment
CAMERA adjustment 1 Flange back adj. CAMERA adjustment 2 Flange back check
F No. compensation Measure gain adj. Mechanical shutter adj. Light value adj.
CAMERA adjustment 3
CAMERA adjustment 4 Strobe adj. CAMERA adjustment 5 Auto focus illumination check
LCD adjustment
(Note 1) Initialization of data
AWB 3200K-5800K standard data input AWB 3200K-5800K check Color reproduction adj. & check CCD linearity check CCD white defect compensation check CCD black defect compensation check
V-COM adj. White Balance adj.
AF illumination LED
LCD unit
(Timing gen., CCD signal process)
LED901
LCD901
IC301
Lens block (Including CD-606 flexible board and CCD imager)
Flash unit
LED
LCD block
SY-145 board
(Internal memory) (Note 3)
IC203
SY-145 board
(COMPLETE) (Note 2, 3, 4)
SY-145 board
zz
zz
z
zz
zz z z
zz
z
z
DSC-S600_ADJ
Table 6-1-1
6-3
Page 6
1-2. List of service tools
J-1
J-4
J-7
J-10
Personal computer (Note 1)
Pattern box PTB-450 J-6082-200-A or Small pattern box PTB-1450 J-6082-557-A
Minipattern box J-6082-353-B
J-2
HASP key and application for adjustment (SEUS)
Contact our service headquater of each area how to get the application for adjustment (SEUS) and HASP key.
J-5
9 colors chart (Note 2)
For PTB-1450: J-6082-562-A
J-8
Flange back adjustment jig J-6082-563-A
J-11
J-3
USB cable 1-827-038-11
J-6
Clear chart
For PTB-450: J-6080-621-A
For PTB-1450: J-6082-560-A
J-9
Siemens star chart J-6080-875-A
J-12
Back ground paper J-2501-130-A
Connection cord DK-2AA 1-830-351-11
AC power adaptor AC-LS5 1-479-284-12
Fig. 6-1-1
Note1: Personal computer
OS: Windows98/98SE/Me/2000/XP Home/XP Pro RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Note2: In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it
matches to the pattern box PTB-450.
1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black.
2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
woody boad A
360 mm
155 mm
135 mm
280 mm
woody boad A
DSC-S600_ADJ
9 colors chart
Fig. 6-1-2
6-4
Page 7
6-1. CAMERA SECTION ADJUSTMENTS
Pattern box
Front of the lens
L = About 9 cm
L
Camera

1-1. PREPARATIONS BEFORE ADJUSTMENTS

1-1-1. Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
Note: Before perform the adjustment, set the following data.
1) Select page: 40, address: 38 and set data: 00.
Insert the connection cord DK-2AA (1-830-351-11).
AC power adaptor AC-LS5 (1-479-284-12)
Fig. 6-1-3
AC IN
PC (The SEUS must be installed in the PC.)
OS: Windows 98/98SE/Me/2000/XP RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required.
To USB connector
To USB connector
Fig. 6-1-4
To USB connector
USB cable
(1-827-038-11)
HASP Key
DSC-S600_ADJ
6-5
Page 8
1-1-3. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and per­form adjustments.
1. Mode switch....................................... CAMERA
2. ZOOM switch .................................... WIDE end
3. Digital Zoom (SET UP setting)......... Off
4. Camera (Menu items) ........................ Auto
9 colors chart (Standard picture frame)
A
Green
Cyan
C14
Effective picture frame
LCD screen
Fig. a
B
Yellow
White
Blue
W14
Red
Magenta
A
A 2
2. Subjects
1) 9 colors chart (Standard picture frame). When performing adjustments using the 9 colors chart, adjust the picture frame as shown in Fig. 6-1-5. (Standard picture frame)
2) Clear chart (Standard picture frame) Remove the 9 colors chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations dur­ing this time)
C
B
C
A = B
C =
C14 : Filter for AWB 5800K adjustment
Transparent window
Fig. 6-1-5
B 3
Adjust the camera position and direction to obtain the LCD screen shown in Fig. a.
DSC-S600_ADJ
6-6
Page 9
3. Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2)
400 mm
513 mm 513 mm 700 mm
woody board B (2)
Fig. 6-1-6
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-7)
370 mm
700 mm730 mm
woody board A
woody board C (1)
700 mm
woody board B
woody board A
DSC-S600_ADJ
woody board B
woody board C
Fig. 6-1-7
6-7
Page 10
1-1-3. Using Method of SEUS
The application for adjustment (SEUS) is used to change the coef­ficient for calculating the signal processing or EVR data. The SEUS performs two-way communication between PC and set through the USB terminal. The two-way communication result data can be written to the nonvolatile memory.
1. Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and set with the USB cable.
3) Confirm that the set starts in the USB mode.
4) Start the SEUS on the PC.
5) Click [Connect] on the SEUS screen. If the connection is nor­mal, the SEUS screen will be as shown in Fig. 6-1-8, indicat­ing the “connected” state.
Note: The SEUS will go in
turned off (for instance, by resetting the set). In such a case, click the “connected” state.
[Connect] on the SEUS screen to restore
“disconnect" state, if the set is
2. Operation
Page change
To change the page, click the page to be changed. The page is displayed in hexadecimal notation.
Address change
To change the address, click [Address] on the SEUS screen and enter the address to be changed. The address is displayed in hexadecimal notation.
Data change
To change the data, click [Set] on the SEUS screen and enter the data. The data is displayed in hexadecimal notation. This operation does not write the data to the nonv olatile memory .
Data saving
To write the all changed data to the nonvolatile memory, click
[Page] on the SEUS screen and enter
[Save] on the SEUS screen and wait for more than 3 sec.
Data reading
The data displayed on the SEUS screen are the data values at the time when the pages and addresses were set, and they are not updated automatically. To check the data change, click
[Read] on the SEUS screen and update the displayed data.
1-1-5. Precaution on Use of SEUS
Wrong SEUS operation could clear correct adjustment data. To prevent the data clear by mistake, it is recommended to save all adjustment data by clicking [Page Edit] on the SEUS screen be­fore starting the adjustment.
Fig. 6-1-8
Saving Method:
1) Click
2) Click [Page], and enter the page number to be saved.
3) Click [Read] to read the data to be saved from the camera.
4) Click [File] and save the data to PC.
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Page Edit] on the SEUS screen to display the SEUS
3) Click [File] and load the data from PC.
4) Click [Write] on the SEUS PAGE EDIT screen.
5) Click [Close] to close the SEUS PAGE EDIT screen.
6) Select page: 40, address: 38 and set data: 00.
7) Click [Save] on the SEUS screen.
8) Select page: 80, address: 34, and check that the data is “00”.
9) Select page: 80, address: 30, and check that the data is “00”.
10) Select page: 00, address: 01 and set data: 00.
[Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
PAGE EDIT screen.
DSC-S600_ADJ
6-8
Page 11

1-2. ADJUSTMENT PROGRAMS

3
2
1
4
5
The DSC-S600 is adjusted with the Automatic Adjustment Program. The Automatic Adjustment Program automatically controls the ad­justment operations that were formerly entered manually on the op­eration screen of the SEUS (some adjustments may be manually op­erated on the SEUS operation screen).
1-2-1. Automatic Adjustment Program
1. Precautions When Using Automatic Adjustment Program
1) The Automatic Adjustment Program writes the adjustment re­sults such as EVR data to the set through two-way communi­cation with the camera via the SEUS. Accordingly, the Auto­matic Adjustment Program must be used in the environment where the SEUS operates.
2) The program run time may vary depending on the environ­ment of the personal computer used.
3) The SEUS must be already started on the PC when using the Automatic Adjustment Program. With the SEUS not started, some adjustment items will take time in adjustment.
2. Start of Automatic Adjustment Program
Double-click the application file (DSC-S600 Auto-Adj Ver_1.[]r
[][]
.exe), and the Automatic Adjustment Program will start.
3. Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu screen in Fig. 6-1-9 will appear. On this screen, select each adjust­ment section.
Fig. 6-1-9
1 [Connecting the Equipment] button
A connection diagram of the equipment is displayed.
2 [CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
Note:[] (numeric value) of the file name v aries depending on the
version of Automatic Adjustment Program.
3 [LCD SYSTEM ADJUSTMENT] button
The “LCD SYSTEM ADJUSTMENT” screen appears.
4 [END] button
The Automatic Adjustment Program finishes.
5 This part indicates the version of Automatic Adjustment Pro-
gram.
DSC-S600_ADJ
6-9
Page 12

1-3. CAMERA SYSTEM ADJUSTMENTS

1-3-1. Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main Menu screen, and the “CAMERA SYSTEM ADJUSTMENT” screen in Fig. 6-1-10 will appear.
1
2
3
4
5
Fig. 6-1-10
1 [To Menu] button
The Main Menu screen comes back.
[Preparation] button
2
Notes for adjustment or jigs used are displayed.
3 [Start] button
Each adjustment from “Camera Adjustment 1” to “Camera Adjustment 5” starts.
4 [Reset] button
This button functions same as the “Initialize” of the setup screen.
5 [Release Data Setting] button
The data setting at the adjustment is cancelled. During the data setting, the button color changes from “white” to “red”. When the data setting is cancelled, the button color returns to “white”. (Use this button when an error occurred in the camera adjust­ment 1-5. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to “white”.)
DSC-S600_ADJ
6-10
Page 13
1-3-2. Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in Table 6-1-2. The Automatic Adjustment Program divides the ad­justment items into five, camera adjustment 1-5. Clicking either CAMERA Adjustment Start button allows the adjustment item which corresponds to that button to be executed. The adjustment conditions of the subject and filter vary depend­ing on which item is adjusted. The Adjustment Program displays an instruction for the subject and filter as a message during the adjustment.
Button Name Adjustment Subject
Siemens star chart with ND filter
CAMERA Adjustment 1 Flange Back Adj. for minipattern box (Note) or
Flange back adjustment jig Siemens star
CAMERA Adjustment 2 Flange Back Check (1.0m from front the lens)
(Luminance: 200 to 400 lux)
F No. Compensation 6F 60, 6B to 6D Measure Gain Adj.
Mechanical Shutter Adj.
Light Value Adj. 6F 65 to 67 AWB 3200K-5800K
CAMERA Adjustment 3
CAMERA Adjustment 4
CAMERA Adjustment 5 Auto focus illumination Check
Standard Data Input AWB 3200K-5800K Check
Color Reproduction Adj. & Check
CCD Linearity Check – CCD White Defect
Compensation Check CCD Black Defect
Compensation Check
Strobe Adj.
Clear chart (Standard picture frame)
9 color chart (Standard picture frame)
Clear chart – (Standard picture frame)
Flash adjustment box (50 cm)
Flash adjustment box (50 cm)
Adjustment Adjustment
Page Address
6D 6F 18 to 53
6F 6B, 6F
6F
6E 00 to 21, 24 to 49
––
6E 60 to 67
––
6E 72 to 75 6F D8 to EF
6D B8 to BF 6F 10 to 15
B0 to B7, C0 to C7 D0 to DB, E1 to F2
6B to 6D, B8 to BB, C7, C8
Note: Dark Siemens star chart.
DSC-S600_ADJ
Table 6-1-2
6-11
Page 14
1-3-3. Adjusting Method
1. CAMERA Adjustment 1
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during Camera Adj.
2. Flange Bac k Adj.
3. Release of Da ta Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 1.
2) The Automatic Adjustment Program ex ecutes “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during Camera Adj. ”, the follo wing message is displayed. Set the sub­ject by referring to “Preparation of Flange Back Adj.”.
Preparation of Flange Back Adj. (Using the minipattern box)
1) The minipattern box is installed as shown in the following f ig­ure.
Note 1: The attachment lenses are not used. Note 2: Take care not to hit the mini-pattern box when ex-
tending the lens.
2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.
Specified voltage:The specified voltage varies according to the
minipattern box, so adjustment the power sup­ply output voltage to the specified voltage writ­ten on the sheet which is supplied with the mini­pattern box.
Below 3 cm
Fig. 6-1-11
4) If the [OK] button is clicked, “2. Flange Back Adj.” and “3. Release of Data Setting during Camera Adj. ” will be e xecuted.
5) Upon successful completion of all items of the CAMERA Adjustment 1, the following message is displayed. Click the
[OK] button.
Fig. 6-1-12
Minipattern box
Camera
Output voltage : Specified voltage ± 0.01 Vdc
Red (+)
Black (–) Yellow (SENS +) White (SENS –)
Black (GND)
Regulated power supply
Output current : more than 3.5 A
Need not connected
Fig. 6-1-13
Preparation of Flange Back Adj. (Using the flange back adjustment jig) (Luminance: about 300 lux)
1) Install the flange back adjustment jig so that the distance be­tween it and the front of lens of camera is less than 3 cm. Note 3: Take care not to hit the flange back adjustment jig
when extending the lens.
2) Make the height of flange back adjustment jig and the camera equal.
3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respec­tively.
Flange back adjustment jig
Below 3 cm
DSC-S600_ADJ
Camera
Fig. 6-1-14
6-12
Page 15
2. CAMERA Adjustment 2
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program e xecutes “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during Camera Adj.”, the following message is displayed. Set the sub­ject in accordance with the message.
Fig. 6-1-15
4) Click the [OK] button is clicked, “2. Flange Back Check” is executed. The following messages are displayed, and then op­erate the camera to make a check in accordance with the mes­sages.
3. CAMERA Adjustment 3
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain Adj.
5. Mechanical Shutter Adj.
6. Light Value Adj.
7. AWB 3200K-5800K Standard Data Input
8. AWB 3200K-5800K Check
9. Color Reproduction Adj. & Check
10. CCD Linearity Check
11. CCD White Defect Compensation Check
12. CCD Black Defect Compensation Check
13. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program ex ecutes the “1. Data Set­ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam­era Adj.”, “2. Picture Frame Setting” is executed. The follo w­ing message is displayed, and then referring to Fig. 6-1-19, set the subject and click the [OK] button.
Fig. 6-1-16
5) Upon completion of “2. Flange Back Check”, “3. Release of Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA Adjustment 2, the following message is displayed. Click the
[OK] button.
Fig. 6-1-18
Check on the LCD screen
C14: Filter for AWB 5800K adjustment
AAB
YellowGreen
Effective picture frame
Transparent window
Fig. 6-1-19
B
C =A = B
3
C
W14
WhiteCyan
BlueC14
Red
Magenta
B
C
A 2
DSC-S600_ADJ
Fig. 6-1-17
6-13
Page 16
After that, the next message is displayed. Then, change the chart in accordance with the message.
Fig. 6-1-20
4) Click the [OK] button, and the items from “3. F No. Compen­sation” to “6. Light Value Adj.” will be executed.
5) Upon successful completion of “6. Light Value Adj.”, the fol­lowing message is displayed. Change the chart in accordance with the message.
At this time, the following message is displayed, and click the [Yes] button if the check result display at the upper right of Color Reproduction Check screen is OK, or the [No] button if NG.
Fig. 6-1-23
8) Upon successful completion of “9. Color Reproduction Adj. & Check”, the following message is displayed. Change the chart in accordance with the message.
Fig. 6-1-21
6) Click the [OK] button, and the “7. AWB 3200K-5800K Stan­dard Data Input” and “8. AWB 3200K-5800K Check” will be executed.
7) After that, “9. Color Reproduction Adj. & Check” will be ex­ecuted. Upon completion of adjustment, the check result is displayed on the Color Reproduction Check screen.
Fig. 6-1-24
9) Click the [OK] button, and the items from “10. CCD Linearity Check” to “13. Release of Data Setting during Camera Adj.” will be executed.
10) Upon successful completion of all items of the CAMERA Adjustment 3, the following message is displayed. Click the
[OK] button.
Fig. 6-1-25
DSC-S600_ADJ
Fig. 6-1-22
6-14
Page 17
9. CAMERA Adjustment 4 Note: “CAMERA Adjustment 4” is available only once after the
power is turned on. If the adjustment is retried, turn off the power and turn on again.
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during Camera Adj.
2. Strobe Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes the “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during Camera Adj.”, the following message is displayed. Set the sub­ject in accordance with the message. (For the Flash adjustment box, refer to “3. Preparing the Flash Adjustment Box” (see page 6-7).)
Fig. 6-1-26
4) Press the [OK] button, and the “2. Strobe Adj.” will be ex­ecuted.
5) During execution of “2. Strobe Adj.”, the following message is displayed. After checking the flashing of strobe light, click
[OK] button. (This message is displayed 2 times during
the execution of adjustment.)
10. CAMERA Adjustment 5
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during Camera Adj.
2. Auto Focus Illumination Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes the “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during Camera Adj. ”, the follo wing message is displayed. Set the sub­ject in accordance with the message. (For the Flash adjustment box, refer to “3. Preparing the Flash Adjustment Box” (see page 6-7).)
Fig. 6-1-29
4) Press the [OK] button, and the “2. Auto Focus Illumination check” will be executed.
5) Upon successful completion of the “2. Auto Focus Illumina­tion Check”, the “3. Release of Data Setting during Camera Adj.” will be executed successively.
6) Upon successful completion of all items of the CAMERA Adjustment 5, the following message is displayed. Click the
[OK] button.
6) Upon successful completion of “2. Strobe Adj.”, “3.Release of Data Setting during CAMERA Adj.” is executed.
7) Upon successful completion of all items of the CAMERA Adjustment 4, the following message is displayed. Click the
[OK] button.
DSC-S600_ADJ
Fig. 6-1-30
Fig. 6-1-27
Fig. 6-1-28
6-15
Page 18

1-4. LCD SYSTEM ADJUSTMENTS

1-4-1. Function of Each Button on LCD System
Adjustment Screen
Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu screen, and the “LCD SYSTEM ADJUSTMENT” screen in Fig. 6-1-31 will appear.
1
1-4-2. Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in Table 6-1-3. The Automatic Adjustment Program executes the ad­justment items if the LCD Adjustment Start button is clicked.
Button
Name
LCD Adjustment
Adjustment Signal Page Address
V-COM adj.
Arbitrary
8F 11
White Balance adj. 8F 42, 43
2
3
4
Fig. 6-1-31
1 [To Menu] button
The Main Menu screen comes back.
2 [Start] button
“LCD Adjustment” starts.
3 [Reset] button
This button functions same as the “Initialize” of the setup screen.
4 [Release Data Setting] button
The data setting at the adjustment is cancelled. During the data setting, the button color changes from “white” to “red”. When the data setting is cancelled, the button color returns to “white”. (Use this button when an error occurred in the LCD adjust­ment. If the adjustment completed successfully, the data set­ting is automatically cancelled and the button color returns to “white”.)
Table 6-1-3
DSC-S600_ADJ
6-16
Page 19
1-4-3. Adjusting Method
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during LCD Adj. & EVR Data Write
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program e xecutes “1. Data Setting during LCD Adj. & EVR Data Write”
3) Upon successful completion of the “1. Data setting during LCD Adj. & EVR Data Write”, the following message is displayed during execution in “2. V-COM Adj. ”. On the SEUS screen, operate the UP/DOWN key so that the brightness of portions A and B on the LCD panel is equal. After the adjustment, click the [OK] button.
SEUS operation screen
UP/DOWN key
Fig. 6-1-35
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-32
4) Upon completion of “2. V-COM Adj. ”, “3. White Balance Adj. ” is executed. The follo wing message is displayed, and then check that LCD screen is not colored. If colored, change the data of page: 8F, address: 42 and 43 on the SEUS Operation screen to adjust so that the LCD screen is not colored.
Fig. 6-1-33
5) If the [OK] button is clicked, “4. Release of Data Setting dur­ing LCD Adj.” will be executed.
6) Upon successful completion of all item the LCD Adjustment, the following message is displayed. Click the [OK] button.
A
Fig. 6-1-36
B
DSC-S600_ADJ
Fig. 6-1-34
6-17
Page 20

1-5. ERROR

In case of an error during the execution of adjustment, the Auto­matic Adjustment Program interrupts the processing at that point, and displays an error message, and then terminates the program execution there.
1-5-1. Error Message
When an error message is displayed, perform the remedy given below , and then retry adjustment. If the error message is displayed though the remedy was performed, the circuits will be faulty.
3. Adjustment Time Out
This part indicates the adjustment item in which an error occurred.
Fig. 6-1-39
1. Connect Error
Fig. 6-1-37
Symptom USB communication with the set is abnormal. Cause USB cable is not inserted tightly.
Power supply is not installed correctly.
Communication with SEUS is abnormal.
Remedy • Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in “USB Mode”.
Install the power supply correctly.
Start the SEUS and click the [Connect] to
check that the connection state is established.
2. RESET the CAMERA and Try Again
Symptom Adjustment does not finish within the specified
time.
Cause Adjustment conditions are wrong.
Data error exists in the camera.
Remedy • Check that the conditions such as a subject
are correct.
Reset the camera.
4. Adjustment NG
This part indicates the adjustment item in which an error occurred.
Fig. 6-1-40
Symptom The adjusted data does not become the speci-
fied value.
Cause Adjustment conditions are wrong.
Data error exists in the camera.
Remedy • Check that the conditions such as a subject
are correct.
Reset the camera.
Fig. 6-1-38
Symptom The camera is not ready for adjustment. Cause Data error exists in the camera. Remedy Reset the camera.
DSC-S600_ADJ
6-18
Page 21
5. Data Save Error
1-5-2. Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment before the adjustment starts. Accordingly, if the adjustment termi­nates by an error, the data during the adjustment may be left in the camera. Note 1: With this data left in the camera, the camera will not
operate normally.
How to cancel the data setting during adjustment is display here.
Fig. 6-1-41
Symptom data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause Data writing to the flash memory failed.
Connection is faulty.
Power supply is not installed correctly.
Remedy • On the SEUS Operation screen, [Set] the data
to the pages and addresses displayed in the message, and [Save] them. (Cancel manu­ally the data setting during adjustment.)
Check the connection.
Install the power supply correctly.
In this case, the “red” on the screen as shown in Fig. 6-1-42 and 43. Click the
[Release Data Setting] button is displayed in
[Release Data Setting] button to cancel the data setting. When
the data setting is cancelled, the button color becomes “white”. Note 2: When “Data Save Error” occurred, the [Release Data
Setting] button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op­eration screen. How to cancel the data setting is displayed in the error message.
Camera System Adjustment screen
Fig. 6-1-42
LCD System Adjustment screen
Fig. 6-1-43
DSC-S600_ADJ
6-19
Page 22

1-6. INITIALIZATION OF DATA

1. Initializing All Page Data
By performing the following procedure, data of all pages will be initialized. Note: If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS SECTOR WRITE screen.
3) Check that the SET ID is “0A”.
4) Click [All] of the ALL SELECT buttons to select all pages. (Fig. 6-1-44 A)
5) Click [Write] to write the initializing data to the flash memory of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Click [Save] on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is “00”.
10) Select page: 80, address: 30, and check that the data is “00”.
11) Perform “Initial Language Data Check”.
Processing after Completing Initializing
Order Page
1402801
Note: At this time, the camera is reset and the power is turns of f
once and then on again. Accordingly, the SEUS goes in “disconnect” state, but this is not a trouble. Click [Con-
Address
Data Procedure
[Set] (Note)
nect] on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the power button.)
B
2. Initializing Single Page Data
By performing the following procedure, data of the page that you want to initialize will be initialized. Note 1: If the 6D or 6E or 6F page data have been initialized, the
following adjustment needs to be performed again.
1) Camera system adjustments
Note 2: If the 8F pa ge data have been initialized, the following
adjustment needs to be performed again.
1) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS SECTOR WRITE screen.
3) Check that the SET ID is “0A”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-44 B)
5) Click [Write] to write the initializing data to the flash memory of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Click [Save] on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is “00”.
10) Select page: 80, address: 30, and check that the data is “00”.
11) When 4F page is initialized, perform “Initial Language Data Check”.
Processing after Completing Initializing
Order Page
1402801
Note: At this time, the camera is reset and the power is turns of f
once and then on again. Accordingly, the SEUS goes in “disconnect” state, but this is not a trouble. Click [Con-
Address
Data Procedure
[Set] (Note)
nect] on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the power button.)
A
0A
Fig. 6-1-44
DSC-S600_ADJ
6-20
Page 23
6-2. SERVICE MODE
1. Setting the Test Mode
Page 40 Address A1, A3
Forced CAMERA mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
2. Bit V alue Discrimination
In the following items, the bit values must be discriminated from the data displayed on the SEUS. Whether bit values are “1” or “0” can be discriminated from the table shown below.
Data displayed on SEUS
0 0
Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
3) Select page: 40, address: A3, and set data: 07.
Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
bit 3 to bit 0 discriminated bit 7 to bit 4 discriminated
Bit values
Display on the bit3 bit2 bit1 bit0
SEUS or or or or
bit7 bit6 bit5 bit4
00000 10001 20010 30011 40100 50101 60110 70111
A
B
81000
91001 A1010 B1011 C1100 D1101 E1110
F1111
DSC-S600_ADJ
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val­ues from block (B).
6-21
Page 24
3. LED Check
Page 80 Address 12 Page 8E Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 8E, address: FE, and set data: 20.
3) Select page: 80, address: 12, and set data: 01.
4) Check that all LED are lit.
SELF TIMER/AF ILLUMINATOR
AE/AF LOCK
FLASH CHARGE
MS ACCESS
5) Select page: 80, address: 12, and set data: 00.
6) Select page: 8E, address: FE, and set data: 00.
7) Select page: 00, address: 01, and set data: 00.
8) Click [Disconnect] on the SEUS screen.
9) Disconnect the USB cable.
10) Turn off the power.
4. Switch Check (1)
Page 80 Address 13
Function When data = 00 When data = 01 When data = 02
Shutter button (XAE LOCK SW) OFF ON ON (RL-063 board S201)
Shutter button (XSHUTTER SW) OFF OFF ON (RL-063 board S201)
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can be discriminated.
DSC-S600_ADJ
6-22
Page 25
5. Switch Check (2)
Page 20 Addresses A0, A1, A3
Using method:
1) Select page: 20, addresses: A0 and A1.
2) By discriminating the read data, the pressed key can be dis­criminated.
Address
A0
(KEY AD0)
(IC101 K23) (S001) (S004) (S002) (S005) (S003)
A1
(KEY AD1)
(IC101 L23)
A3
(MODE DIAL0)
(IC101 L22) (S008) (S008) (S008)
6. Self Diagnosis Code
Display Code
C:32:ss
C:13:ss
00 to 10 2A to 32 48 to 53 5F to 6B 71 to 7E 7F to FF
CONTROL DOWN CONTROL RIGHT CONTROL UP CONTROL LEFT CONTROL SET
(SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD)
SCREEN IMAGE SIZE/
STATUS DELETE
(SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD)
(S007) (S009) (S008) (S010) (S006)
MOVIE PLAY STILL
(SW-461 BOARD) (SW-461 BOARD) (SW-461 BOARD)
Countermeasure
Turn the power off and on again. Format the “Memory Stick” or internal
memory. Insert a new “Memory Stick”.
MENU ZOOM W ZOOM T
Trouble with hardware. “Memory Stick” or internal memory is
unformatted. “Memory Stick” is broken.
Data
Cause
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
No key input
No key input
Trouble with internal mamory.Turn the power off and on again.
E:61:ss
E:91:ss
E:92:ss
Note: After r epair, be sure to execute the “Initialize” of the setup screen.
Checking of lens drive circuit. Checking of flash unit or replacement
of flash unit. (Note) Insert a batteries correctly.
When failed in the focus zoom initialization. Abnormality when flash is being charged.
Batteries are pack is not inserted correctly.
INTERNAL MEMORY ERROR
_
DSC-S600_ADJ
6-23
6-23E
Page 26
Reverse
987692251.pdf

Revision History

Ver.
1.0
Date
2005.12
History
Official Release