Introduction
This heater is primarily intended for installation onto a wall at high level. The maximum
recommended installation height is 2.1 metres to the underside of the heater. There is
no clearance required above or to the side of the heater.
Electrical installations for these heaters must only be carried out by a suitably qualified
person.
Model HL 1000-12V
This model is designed for use in bathrooms and other high humidity areas. For these
applications it is essential that the heater, transformer and fused spur are installed in line
with current regulations relative to fixed current equipment in high humidity areas, wet
rooms and/or bath and shower rooms.
The transformer has been designed to fit into a surface-mounted or recessed pattress
box (not supplied) similar to those used for shaver sockets (47mm deep). The
transformer can be mounted horizontally or vertically however it must not be directly
above the heater but should be accessible after completion of the installation.
Supply to the transformer must be via a 3 amp fused spur. The fused spur must not be
directly above the heater but should be accessible after completion of the installation.
Twin core cable is fitted to the product for connection to transformer. HL 1000-12V
should not be earthed
Models HL 1000, HL 2300, HL 2900 & HL 4000
These models must not be installed in bathrooms or other high humidity areas.
Ecovector® is classified as a fixed appliance and electrical connection should be via a
3A-fused spur. The fused spur must not be directly above the heater but should be
accessible after completion of the installation. If the pre-wired mains cable is damaged it
must be replaced by the manufacturer, its service agent or similarly qualified persons.
This appliance must be earthed.
For models HL 2900 and HL 4000 we recommended that when securing the product to
the wall two persons should lift the heater into position.
All models
These heaters are designed for use on standard two-pipe pumped central heating
systems. Pipes are 15mm for models HL 1000, HL 1000-12V, HL 2300, HL 2900 and
22mm for model HL 4000. Either pipe may be used as flow or return. These heaters are
not suitable for one-pipe systems.
We recommend the use of full flow isolating valves. The valves should be accessible after
completion of the installation. We also advise the fitting of an air vent at the highest
point on either the flow or return pipe to remove any air trapped within the system.
To avoid the possibility of vibration these heaters must be fitted on a flat even surface.
To conform to Building Regulations Part L (Part J in Scotland) these Ecovector® heaters
can be controlled by a remote wall mounted room thermostat (Smith’s Environmental
Products Part No. RT002). For further details please contact us on 01245 324560.
2
Versatile, energy efficient heating
ECOVECTOR
®
High Level
Fan Convector
Models
HL 1000, HL 1000-12V
HL2300, HL2900, HL4000
USER GUIDE
7
Dear Customer,
We are delighted you have chosen one of our products and trust you are
satisfied with the installation. We would ask you to take a few minutes to
read the User Guide to help you gain maximum benefit from your Ecovector®
fan convector. As with all our products your Ecovector® is covered by a
free five-year parts and labour guarantee and we would be grateful if you
complete and return the Guarantee Registration Card to us as soon as
possible. This will ensure that should you require assistance we can deal
with you quickly and efficiently.
Thank you for your co-operation.
Steve Russell
Technical Services Manager
01245 324900
P.s Your Ecovector® is designed to operate as part of your central
heating system in the same way as a panel radiator. Providing you
leave the heat output switch in either the normal I or boost position
II and the fan-only switch set to RED your Ecovector® will switch
on and off automatically with your central heating system.