contained in this Instruction Manual,
your appliance will give you constant
high performance and will remain
efficient for many years to come.
CONTENTS
RECOMMENDATIONS AND SUGGESTIONS10
CHARACTERISTICS11
INSTALLA TION12
USE14
MAINTENANCE15
9GB
RECOMMENDATIONS AND SUGGESTIONS
650mm.min.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting
from incorrect or improper installation.
• The minimum safety distance between the cooker top and the
extractor hood is 650 mm.
• Check that the mains voltage corresponds to that indicated on the
rating plate fixed to the inside of the hood.
• For Class 1
guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of
minimum diameter 120 mm. The route of the flue must be as short
as possible.
• Do not connect the extractor hood to exhaust ducts carrying
combustion fumes (boilers, fireplaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances
(e.g. gas burning appliances), a sufficient de gree of aeration must
be guaranteed in the room in order to prevent the backflow of
exhaust gas. The kitchen must have an opening communicating
directly with the open air in order to guarantee the entry of clean
air.
USE
• The extractor hood has been designed exclusively for domestic
use to eliminate kitchen smells.
• Never use the hood for purposes other than for which it has ben
designed.
• Never leave high naked flames under the hood when it is in
operation.
• Adjust the flame intensity to direct it onto the bottom of the pan
only, making sure that it does not engulf the sides.
• Deep fat fryers must be continuously monitored during use:
overheated oil can burst into flames.
• The hood should not be used by children or persons not instructed
in its correct use.
a
appliances, check that the domestic power supply
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before
carrying out any maintenance work.
• Clean and/or replace the Filters after the specified time period.
• Clean the hood using a damp cloth and a neutral liquid detergent.
Make a rectangular opening on the base of the
hanging unit, leaving a minimum of 13 mm from
the outer edges.
Hood Type5270
L1497677
SNAP-ON FITTING
For hoods with snap-on side supports only, set up for a support panel thickness of between 15
mm and 30 mm.
• Insert the hood until the side supports snap into
place.
• Lock in position by tightening the screws Vf
from underneath the hood.
12GB
125
120
9
ø 120
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 120 mm.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 120 mm in the wall unit over the
hood.
• Connect the hood body outlet to the top part of
the wall unit using a rigid or flexible pipe ø 120
mm, to be selected by the installer.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
• When opening the sliding carriage for the first time after installing the hood, pull it out briskly
until it clicks.
13GB
USE
Control Panel
LLightSwitches the lighting system on and off.
MMotorSwitches the extractor motor on and off.
VSpeedSets the operating speed of the extractor.
14GB
A
A
MAINTENANCE
Grease filters
CLEANING METAL SELF-SUPPORTING GREASE FILTERS
• The filters must be cleaned every two months
of operation, or more frequently with heavy
usage.
• Remove the filters one at a time, after
disconnecting the relative fastening elements.
• Wash the filters, taking care not to bend them.
Allow them to dry before refitting.
• When refitting the filters, make sure that the
handle is visible on the outside.
Odour filters (Recirculation version)
REPLACING ACTIVATED CHARCOAL FILTERS
• These filters are not washable and cannot be
regenerated, and must be replaced
approximately every four months of operation,
or more frequently with heavy usage.
• Dismantle the ducting support pulling the two
pommels A simultaneously .
• Remove the saturated activated carbon filters
by releasing the fixing hooks.
• Fit the new filters by hooking them into their
seating.
• Close the ducting support by pushing and
connecting the two pommels A.
Lighting
LIGHT REPLACEMENT
• 20 W halogen light.
• Dismantle the ducting support pulling the two
pommels A simultaneously .
• Extract the Lamp from the Support.
• Replace with another of the same type, making
sure that the two pins are properly inserted in
the lamp holder socket holes.
• Close the ducting support by pushing and
connecting the two pommels A.
15GB
Quest’apparecchio è conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa alla sicurezza elettrica e alle norme
europee: C.E.E. 89/336 relativa alla compatibilità elettromagnetica e C.E.E. 93/68 relativ a alla marcatura CE.
This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety , European Directiv e 89/336/
CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking.
Dieses Gerät entspricht folgenden EG-Richtlinien: Niederspannungsrichtlinie EWG 73/23 hinsichtlich elektrischer Sicherheit,
Richtlinie Elektromagnetische Verträglichkeit EWG 89/336 und Richtlinie EWG 93/68 hinsichtlich der CE-Kennzeichnung.
Cet appareil est conforme à la norme européenne en matière de basse tension C.E.E. 73/23 de sécurité électrique ainsi qu’aux
normes européennes : C.E.E. 89/336 en matière de compatibilité électromagnétique et C.E.E. 93/68 en matière de label CE.
Dit apparaat voldoet aan de Europese laagspanningsnorm 73/23/EEG inzake de elektrische veiligheid en de Europese normen:
89/336/EEG inzake de elektromagnetische compatibiliteit en 93/68/EEG inzake de CE-markering.
Este aparato es conforme con la normativa europea sobre baja tensión C.E.E. 73/23 correspondiente a la seguridad eléctrica y a
las normativas europeas: C.E.E. 89/336 sobre la compatibilidad electromagnética e C.E.E. 93/68 respeitante à marcação CE.
436001633 01 - 021210
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.