INSTRUCTIONS FOR THE INSTALLER: these are intended for the
qualified technician who must install the appliance, set it functioning
and carry out an inspection test.
INSTRUCTIONS FOR THE USER: these contain user advice,
description of the commands and the correct procedures for cleaning
and maintenance of the appliance.
12
Introduction
1. INSTRUCTIONS FOR SAFE AND PROPER USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND
THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE
PLACE FOR THE WHOLE WORKING LIFE OF THE STERILIZER. WE ADVISE
READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE
USING THE STERILIZER. INSTALLATION MUST BE CARRIED OUT BY
QUALIFIED ENGINEERS IN ACCORDANCE WITH THE REGULATIONS IN
FORCE. THIS STERILIZER IS INTENDED FOR COMMERCIAL USES AND
CONFORMS TO CURRENT REGULATIONS IN FORCE.
THIS APPLIANCE MUST ONLY BE USED BY SPECIFICALLY AUTHORISED
STAFF TRAINED IN ITS CORRECT USE. THE APPLIANCE MUST ONLY BE
USED FOR ITS INTENDED PURPOSE: THE STERILIZATION OF SURGICAL
INSTRUMENTS IN A MEDICAL AND PARA-MEDICAL CONTEXT. THE
APPLIANCE MUST NOT BE USED FOR TREATING CONTACT LENSES
UNDER RULE 15 - ANNEX 9 - SUBSECTION 1.
ALL OTHER USES ARE CONSIDERED IMPROPER.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER
USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE
THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST
SPECIAL GARBAGE COLLECTION CENTRE. THE STERILIZER IS SUPPLIED
IN SUITABLE PACKAGING WHICH REQUIRES THE NORMAL PRECAUTIONS
FOR TRANSPORTATION OF FRAGILE MATERIALS, AS INDICATED ON THE
PACKAGING ITSELF. IF THE APPLIANCE IS RETURNED, USE THE ORIGINAL
PACKAGING.
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED
ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT
BOTH ARE COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE
COMPLYING WITH APPLICABLE REGULATIONS.
NEVER UNPLUG BY PULLING ON THE CABLE.
DO NOT OBSTRUCT VENTILATION OPENINGS AND HEAT DISPERSAL
SLITS.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION
TEST OF THE STERILIZER, FOLLOWING THE INSTRUCTIONS BELOW.
SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE
SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
13
ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE 0 (OFF)
POSITION WHEN YOU FINISH USING THE STERILIZER.
NEVER PUT INFLAMMABLE OBJECTS IN THE STERILIZER: THEY COULD BE
ACCIDENTALLY LIGHTED AND CAUSE FIRES.
THE I.D. PLATE WITH TECHNICAL DATA, REGISTRATION NUMBER AND
BRAND NAME IS LOCATED IN AN EXPOSED POSITION AT THE REAR OF
THE STERILIZER.
THE PLATE MUST NOT BE REMOVED.
THE APPLIANCE IS INTENDED FOR COMMERCIAL USE BY
APPROPRIATELY TRAINED PERSONNEL. CHILDREN SHOULD ALWAYS BE
KEPT OUT OF ITS REACH AND NEVER BE ALLOWED TO PLAY WITH IT.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE
2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE).
THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF
RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND
PROTECTIVE FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
Introduction
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance or by the use of non-original
spares.
THE WARRANTY COVERS PRODUCTION DEFECTS AND IS
SUBJECT TO THE CONDITIONS OF THE CERTIFICATE WHICH
ACCOMPANIES THE APPLIANCE.
14
Instructions for the installer
2. INSTALLATION OF THE STERILIZER
The sterilizer must be set up on a perfectly flat surface and left standing
free. Make sure to allow enough room at the back for easy access to the
terminal strip for connection of the power cable to mains.
Installation must be carried out by a qualified technician in compliance
with applicable regulations in force.
2.1 Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located to the rear of the sterilizer. This rating plate must never be removed.
The sterilizer is supplied complete with a H07RN-F three-core supply
cable for operation from a 230V∼ power supply.
The standard cable is of the three-core
3 x 1.5 mm2 H07RN-F type.
If necessary the electrical supply cable
should be replaced with an oil-resistant
type (min. H05RN-F 3 x 1.5 mm2).
The (yellow/green) earth cable on the
end of the cable to be connected to the
sterilizer should be at least 20 mm
longer.
Make sure that plug and wall socket are of the same type and are in
conformity with regulations in force. Also check that the power supply
line is provided with adequate earthing. Avoid using adapters or
shunters.
In case of permanent connection, ensure that power cable is equipped
with an easily accessible omnipolar switch fitted in proximity to the
apparatus and with a gap between contacts equal to or greater than
3 mm.