CONTACT
If you have technical problems, first contact your installer. The following information is required in order to provide
you with the necessary assistance:
• Inverter device type
• Inverter serial number
• Type and number of the PV modules connected
• Event number and display message on the inverter
• Optional equipment, e.g. communication products
• Confirmation of whether or not a multi-function relay is used
SMA Solar Technology AG
Sonnenallee 1
34266 Niestetal, Germany
www.SMA.de
SMA Service Line
Inverters +49 561 9522 1499
Communication: +49 561 9522 2499
Fax: +49 561 9522 4699
E-Mail: ServiceLine@SMA.de
PV Inverter
SUNNYBOY2500TLSingleTracker
SUNNYBOY3000TLSingleTracker
User Manual
Installer contact
EXPLANATION OF SYMBOLS
Symbols on the Inverter
Inverter This symbol defines the function of the green LED. The green LED
indicates the operating state of the inverter.
Read the
documentation
Bluetooth
QR code
Danger There are special requirements for earthing.
®*
This symbol defines the function of the red LED. The red LED
indicates a fault. If it lights up, contact your installer.
This symbol defines the function of the blue LED. The blue LED
indicates that the communication via Bluetooth is activated.
By scanning this code, the solar power professional installing the
inverter can register the inverter and take part in the SMA bonus
programme.
SB25_30TLST_21-BA-BEN121110 l IMEN-SBTLST-21 l Version 1.0
Outdoor The inverter is suitable for outdoor installation.
RAL quality mark for
solar products
Certified safety The inverter is VDE-tested (Association for Electrical, Electronic
Australian mark of
conformity
The inverter complies with the requirements of the German
Institute for Quality Assurance and Labelling.
and Information Technologies) and complies with the
requirements of the German Equipment and Product Safety Act.
The inverter complies with the requirements of the applicable
Australian guidelines.
EN
* QR-Code® is a registered word mark of DENSO WAVE INCORPORATED.
Symbols on the Type Label
IP54
Danger to life due to
high voltages
Risk of burns from hot
surfaces
Read the
documentation
DC Direct current
Without transformer The inverter does not have a transformer.
AC Alternating current
Proper disposal Do not dispose of the inverter together with the household waste.
CE marking The inverter complies with the requirements of the applicable EC
Device class ID The inverter is equipped with a wireless component and complies
Degree of protection The inverter is protected against dust deposits in the interior and
The inverter operates at high voltages. All work on the inverter
must be carried out by skilled persons only.
The inverter can become hot during operation. Avoid contact
during operation.
Observe all documentation that is supplied with the inverter.
directives.
with device class 2.
against splashes of water from all angles.
GLOSSARY
Bluetooth*
®
Bluetooth
to communicate with each other. For Bluetooth communication, the Bluetooth devices do not need to be within
sight of each other.
Electronic Solar Switch (ESS)
The Electronic Solar Switch is an optional available DC disconnection unit. If the inverter is equipped with an
Electronic Solar Switch, the ESS must be securely inserted into the bottom of the inverter. The Electronic Solar
Switch may only be removed by electrically qualified persons.
Energy
Energy is the power which a system can supply or consume within a certain time unit. Energy is measured in Wh
(watt hours). If, for instance, your inverter feeds in for half an hour at 3 000W and half an hour at 2 000W, it
will have fed a total of 2 500Wh into the electricity grid.
Multi-function relay
The multi-function relay is an optional interface for managing a fault indicator or another external load.
Depending on the parameters and measured values, the inverter determines when the connected load is switched
on and off.
Power
Power is the product of voltage and electrical current strength. Power is measured in W (watts). The power shown
in the display is an instantaneous value. It indicates the power your inverter is currently feeding into the electricity
grid.
PV
Abbreviation for photovoltaics.
*The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of this mark by
SMA Solar Technology AG is under licence.
Wireless Technology is a radio technology that allows the inverter and other communication products
SAFETY PRECAUTIONS
Model
SB XXXXXXXXXXX
SUNNY BOY
Serial No.
XXXXXXXXXX
Solar Inverter* made in Germany
by SMA Solar Technology AG
SMA Solar Technology AG
Sonnenallee 1
34626 Niestetal
Germany
www.SMA.de
Date
kVAr
kVArh
kW
h
MVArh
M
W
h
kW
kWh
D
V
E
SB 5000TL-21
**
X
X
X
SUNNY BOY
Ph
otov
oltai
c string
in
ve
rte
r * M
ade
in
G
e
rm
any
XXX
P
I
D
V
E
Danger to life due to high voltages in the inverter
Even when no external voltage is connected, there may still be high voltages present in the inverter.
• Do not open the inverter.
• Electrical installation, repair and retrofitting may only be carried out by a skilled person.
Risk of burns due to hot enclosure parts
• During operation, only touch the lower enclosure lid and the display.
Yield loss due to poor heat dissipation
• Do not place any objects on the enclosure.
CLEANING THE INVERTER
Damage to the display by use of cleaning agents
• If the inverter is dirty, clean the enclosure lid, the display and the LEDs using only clean water and a cloth.
PRODUCT OVERVIEW
Type label for identifying the inverter
Serial number
Upper enclosure lid
Lower enclosure lid
Display
ESS (optional)
LEDs
DISPLAY
The display updates the measured values of your PV plant every five seconds.
You can operate the display by tapping it:
Single tap: to activate the backlight, to scroll to the next text line, to switch
between the power graph of the past 16 feed-in hours and the energy
yields of the past 16 days.
Double tap: the display alternates automatically between the firmware
version, the serial number of the inverter, the Bluetooth NetID, the
configured country data set and display language.
Power and yield curve
An error has occurred:
Contact installer.
PLANT OVERVIEW
Input voltage/
input current
Current power
Daily energy
Total energy generated since the inverter was installed
Display of enabled functions
Text line to display event or error messages
Switch open: the inverter does not feed into the grid.
Switch closed: the inverter feeds into the grid.
Output voltage/
Output Current
POWER AND YIELD CURVE
The power and energy of the inverter are displayed as diagrams. The daily
power graph is displayed by default. The right-hand flashing bar of the diagram
represents the current hour. If the inverter does not feed any power to the electricity
grid over a longer period of time (e.g. during the hours of darkness or if the PV
modules are covered with snow), a gap is inserted into the chart. The bar for the
current hour is updated automatically every five seconds.
After four seconds, the bar disappears for one second and then displays the
current value.
By tapping on the enclosure lid, you can alternate between displays, and the
graph will switch to show the energy yields of the last 16 days.
DISPLAY OF ENABLED FUNCTIONS
Bluetooth
communication
Multi-function relay
Event number relating to the PV
array
Power limitation
Indicates which phase the
displayed values are assigned to
Event number relating to the
electricity grid
Event number relating to the
inverter
POWER DISPLAY
The power and energy of the inverter are displayed in the three fields: "Power", "Day" and "Total". The display is
updated every five seconds.
The power that the inverter is currently feeding into the electricity grid.
The energy fed into the electricity grid on this particular day. This
equals the energy generated from the inverter's start-up in the
morning to the current time.
The total energy that the inverter has fed into the electricity grid
during its entire operating time.
LED SIGNALS
Green LED is on The inverter is in operation.
Green LED is flashing Conditions for grid connection are not yet fulfilled.
Red LED is on An error has occurred.
• Contact installer.
Bluetooth
connection quality
Power reduction due to excessive temperatures
• Improve the ventilation of the inverter
• If the symbol is frequently displayed, contact your installer.
Blue LED is on Bluetooth communication is activated.
Blue LED is flashing The inverter has been identified via Sunny Explorer by activating the
"Find device" parameter.
MEASUREMENT ACCURACY
The display values may deviate from the actual values and must not be used as a basis for invoicing. The inverter's measured values are required for the operational control and to control the current to be fed into the electricity grid.